Loading...
HomeMy WebLinkAboutWIND LOAD CERTIFICATIONENGINEERING SUBMITTALS fi Fe `1�2015: FILE WIND LOAD CERTIFICATION: CODE: FBC2010/ASCE7-10/NEC2008 WIND SPEED.160 mph, 3 SEC. GUST EXPOSURE: "B" CATEGORYH INTERNAL PRESSURE COEFF.: 0.00 HEIGHT: 60' max SIDATe-� JOB: ARCADE SIGN 4848 N. KINGS HWY FORT PIERCE, FLORIDA I YWn.�. DATE: —� IDASLE:,�—�—J— CPAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Bildnore St Suite #114 Port Saint Lucie, FL 34984 (772) 785-9888 pwelchinc@aoLcom Paul Welch, P.E. Fla Reg No. 29945 °1-11 y ED ! or;e Count, I:fiIN, SEY��tCK FEC�, FRONT SIDES CNR SIDG REAR ZNG. j TECH. ARCADE SIGN PAUL WELCHINC. ' I SACLE 1/4" = V MIKE MIRANDO ME'oNAmCAL aRcrwaAL CIVIL.6NQIMEMNG I984S.W. BiL7moAEST. sulwj i'1I4 4848 N. KINGS HWY PORrS.aNrLUa/E, FL 34984 FORT PIERCE, FL 34951 PAU WazCH PE F`FZAR&WNo 29945 i FEB 2 7 2015 4M.µ'Lit 05 19" 1 R" 97" R" 21" 27" 27" NOTE: Wall is plywood with stucco on 6" steel framing members — Sign to be supported with 2"x 6" PT run continuous In back of wall with (8) - %" thru bolts at locations shown 26" ARCADE SIGN PAUL WELCH INC. 1/2" = 1' MECHANICAL ELECTRICAL CIVIL ENGINEERING �� MIKE MIRANDO 1984S.W.BILTMOREST.SUr'E#114 i 4848 N. KINGS HWY PORT SAINT LUCIE,FL34984 FEB 2 1015 (772) 785-9888 PWELCHINCQAOL.COM FORT PIERCE, FL 34951 PAULWELCH,P.E. FLALICNo. 29945 "TYPICAL" RACEWAY -MOUNTED CHANNEL LETTER NOTE: CHANNEL LETTER SIGN TO DE U.L. LISTED ses 51rnr1 OV44 wK AACU0, 1MA. ' # 6 X 1/2" SELF TAPPING SCREWS TO SECURE TRIM CAP RACEWAY LID t^*-n PAS ■ U.L. LISTED WEATHER -TIGHT CAPS OR U.L. L15TEP SHORTCAPS BY ELECTROBITS U EXTERIOR SERVICE SWITCH 1/6" U.V. COATED PLEXIGLA55 4 6" WIDE x 6" T012" TALL METAL RACEWAY. (HEIGHT OF RACEWAY DEPENDS UPON FEDERAL BUSHING SIZE OF LETTER) COLOR OF RACEWAY TO MATCH EXISTING WALL NEON TUBING GLASS NEON TUBE SUPPORT RIVETED TO 5/16" BOLT THRU 1/4" ALUMINUM FLAT STOCK & RACEWAY RETURN CAN (COPPER WIRE USED TO U.L. LISTED FASTEN NEON TO SUPPORT) t L.E.D. TYPE TRANSFORMER (30 MILLIAMPS EXTERIOR TYPE WIRED U.L. LISTED GTO WIRE I BY LICENSED ELECTRICAN) 3/10" TAPCRR 5" DEEP ALUMINUM CHANNEL LETTER 1/4" HAMMER RETURN CAN WITH 201/4" DRAIN HOLES AT BOTTOM DRIVE ANCHOR SIDE VIEW �n PLEXIGLA55 FEB 2 7 2015 TRIMCAP PAUL WELCH INC. RETURN CAN MECH984 -ELECT -LIILTIMORE ST. E 14 NEON TUBING STROKE PORT SAINT LUCIE. FL 34984 Model &Tildmg Code Regulations Page I of I Plexiglas® Expert Drdire gnowlsdge Vase Close This DocuFrRnt PLEXIGLAS®: MODEL BUILDING CODE COMPLIANCE Modd Bmtding Code Ritgubbons for Ligbt Trammit1mg Plastic Ad gmdes of PlnlfgbsAcryde Plate wootthe requwencenb Smoke Dense tr Ong of [COO for a Clans CC-Z b9ldtraramati,g galas. Pliodglas ASTM 0-2843: Platte mstemile which campy WM the Model Is avaft(e to G. C. SO. T and MC shoet, V Grade. W. HFl Building Codes must have a smote dmuiyl rating no greeter and DR Impact Grade molding pe6e6. Some Plmdgles than 75 When tsd®d in accordance with ASTM D-284& applications include: Skyfigha. Light D'dfusem. Sign Piudgtas Am* Plastic has a amoko deri ty rating of 4 to 12. Applicaboins and Glaarg. Pimd9las meela the specilkadons of In Model Building Codes for smoke density rating. pbxigtasA FyicRamiematatebarelidoInthefeilaeing Modal Boldng Code Compiahoe Reports: I= ER-10C4. UL: m tame Class PYxg4s Y Grades and DR Impact Grades have a UL 94 HB rating with a minimwh #do= s of mtldcW 0018as a UL 94 NO m'Peirtedior op&muing h Cite of limos Angeles, Depar mart of a with a nibilmum O hmhes (1.67 mm). Budding and Safety. Stele of Michigan, Fire Marshal; City of Plesigbs IW Grades have a 1R94H8 rating W M a muftum New Yorks MEA 107-OW MFA44-60SM land varias o0ro tlddma s of .12400:f inches (3.17 mm). Wandgps Shod has a City and Slate Budding Code authors. UL 94 HO rating with a minimum thldmess of 0.0516 inches (1.57 mm). . Horlmnlal Bran Lahpib ASTM 06635: Pbodc materials Which have a burning extent of Limitations 1 Men or lass are classified as CC-1. Plastic materials which The Model Budding Codes omit the use of approved plastic have a bum tahgth of ZS Inches per minute or less are material by 1epas1 on mrsdmmergs and area fimib. A Claw daard' teed as CC-2 PheagLs Aaydc Plastic has a horizontal CC-2 material (Piadglas) Is permitted up to 257E of the Win rate between 1.1 and 1.9 hNmin. and is doweled as a aaerior Wad area. Limitations Include the size of each panel. CC-2 wittransmhting plastic the distance beb pan parcels, bmTdng height building type and location. SNWgNtihn Temparalnn ASTM D-10M Plastic materials slag have a selRIgniion 80-2 (Revised 11=0115) - I CD temperature ofgreaterthan6SWIF Pbndgbshas aseH- Igrdtion temperature of740 to SWF. The atatem@nM technical information and nmmmandhtisns obb6nd herein are believed to be accurate as of the data henaf. Since the conditions end mamods of ass of the product and of the information reMred to herein lire sayond our control, Adorns ecpnasly distlssns any and 10 Babtsty. NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OR MERCHANTABILITY, OR ANY OTHER WARRANTY DWRESS OR BWL.rW, 15 MADE CONCERNING THE GOODS DESCRIBED OR THE INFORMATION PROVIDED HEREIN. The Infon allen provided herein relates only to the specific product designated and may not be applicable when such product B used in combination with other materials or In eny Process. The user should Uwrowhly tall any application before commercialization. Nothing contained herein should be construed man badueemant to bdkh a nnirpsteM, and the user Is advised to taka appropriate steps to be sure sat any proposed use of the product ■ win not result In patent Infringement See MSDS for Hashb and SaFRYp?i ddaraik�a. a f! I -Bola= ® 2005 Arkema Group hi(p://W Ww.plexiglas.com/WbWas/expeNdata.cEm?wid -7 3/1/2006 r.v .. C� f'Q S N ggp®� a d 26„ 154" r o C 22.5' Lj I E 42' ARCADE SIGN SACLE 1/411= 1' MIKE MIRANDO 4848 N. KINGS HWY FORT PIERCE, FL 34951 26" I V-e ARCADE SIGN SACLE 1/2" = 1' MIKE MIRANDO Wall is drywall with stucco over it supported by 6in steel beams. 4848 N. KINGS HWY will support sign with 2by 6 behind beams through bolted with FORT PIERCE, FL 34951 8 half inch bolts.