HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2
Flo da De-rtmenitl MS Hame I Log 1 User ReglStrd.. i Hot Toacs I Submlt Surcharge I Suits &Facts 1 Publlradons I FSC Stan 1 acts Sit. Map i Links I sea" I
Businesij(h
Professi 1 a,
n Product Approval
0- USER: Public User
Regulation
PratluR Avomval Menu >Proaud or Aool canon
Search >Apvlicaaon Lkt>Application Historv>Application Detali
-�
FL #
FL5259-R39
Application Type
Revision
Code Version
2010
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
[in
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
James Akins
jakins@polyglass.com
Steve Wadding
150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polyglass.com
James Akins
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
Roofing
Underlayments
SCANNED
BY
St. Lucie County
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
R Evaluation Report- Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
07/01/2017
John W. Knezevich, PE
W Validation Checklist - Hardcopy Received
ctandard
ASTM D1970
ASTM D226
2006
ASTM D6164
2005
ASTM D6222
2002
ASTM G154
2005
ASTM G155
2005
FM 4474
2004
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDgvbSgAaZp3Crk... 3/6/2015
Florida Building Code Online
Page 2 of 2
FRSA/TR107320
TAS 103
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
07/0112014
Date
Validated
07/02/2014
Date
Pending FBC Approval
07/04/2014
Date
Approved
06/25/2014
Date
Revised
08/25/2014
Summary of Products
2005
1995
FL 7f
Model, Number or
Description
Name
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL5259 R19 11 2014 07 FINAL ER POLYGLASS VNDERLAYMENT5 FLr259-
R19,D(1f
Verified By: Robert Nleminen PE-59166
Created by Independent Third Party: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure in this
application relates to one particular
underlayment system for use under foam-
on tile systems. Refer to ER Section 5.5.2
Evaluation Reports
,EL5Z5%_R39 AE 2014 07 FINAL ER POLYGLASS UNDERLAYMENTS FL5259—
RR1 ,0dF
Created by Independent Third Party: Yes
for other systems and maximum deslgn
pressures. 2.) Refer to ER Section 5 for
other limits of use.
Haut Neil
Conrad Us:: 19,10 NoahM SemetTallahassee F332399 Phone, 850-487-1824
The State of Florida is an AA/EEO employer. Cooydaht 2007-2013 State of Florida.:: Privmv Statement:: p .Ab'resy N Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mall to his entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Ronda Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may he used for oi0tlal communication with the licensee. However email addresses are public recoM. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to me public. To determine If you are a Ilcensee under
chapter 455, F.S., please dI& hiI
Product Approval Accepts:
mg 9 eCt4;. 0
mcuritvAuIurn'
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param--wGEVXQwtDgvbSgAaZln3 Crk... 3/6/2015
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
ERD
353 CHRISTIAN STREET, UNIT#13
.j' TRINITY;
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Polyglass USA, Inc.
Evaluation Report P12060.02.09-R14
150 Lyon Drive
FL5259-R19
Fernley, NV 98408
Date of Issuance: 02/24/2009
Revision 14: 07/01/2014
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been designed to comply with the Florida Building Code, 2010 sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance.documentation changes. Trinity] ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4 ANE1983
The facsimile seal appearing was.0 usrited
by Robert Nieminen. P.E. on 07/01/2014
This does not serve as an electronically signed document.
Signed, sealed hardcoples have been transmitted to the
Product Approval Administator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
�t I KINITY 1 ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject
to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.3,1507.3.3, 1507.5.3,1507.7.3,
Physical Properties
ASTM D226
2006
1507.8.3,1507.9.3
1507.2.4, 1507.2.9.2,1507.3.3, ]5075.3
Physical Properties
ASTM D1970
2001
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6272
2002
1504.6
Aceelemted Weathering
ASTM G154
2005
1504.6
Accelerated Weathering
ASTM G155
2005
15043.1
Wind Uplift
FM 4474
2004
1507.3.3
Installation Practice
FRSA/TRI07320
2005
1523.6.5.2.1
Physical Properties
TA5103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST5878)
Physical Properties
PR101111
04/08/2002
PRI (TST5878)
Physical Properties
PUSA-WS-02-01
O1/31/2002
PRI (TST5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
• PRI (TST5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST5878)
Physical Properties
PUSA-083-02-01
D4/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14EBA
O1/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD(TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD(TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P31030.11.09-2
11/30/2009
ERD (TSr 6G49)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.30
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
ERD (TST 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD UST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TV 6049)
Physical Properties
C41420.09.12-3
09/11/2012
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R14
Cero'fimte olAuNoriiatlon 11950 FL521
� iY07101�2014
2of
FILE U
Page 2 of 11
! 1 K\iINrry ERD
Entity Examination Reference Date
ERD 0ST 6049) Wind Uplift P39680.03.13. 03/04/2013
ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD (TST 6049) Wind Uplift P3738.02.07-112 04/29/2013
ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD PST 6O49) Wind Uplift P41630.08.13 08/06/2013
ERD (TST 6049) Wind Uplift P11751.05.03-R7 11/26/2013
ERD (TST 6049) Wind Uplift P11781.11.03-RS 11/26/2013
ERD (TST 6049) Physical Properties P45270,05.14 05/12/2014
ERD UST 6049) Physical Properties P443605C 05/15/2014
]CC -ES (EVIL 2396) IBCCompliance ESR-1697 09/O1/2012
Miami-Dade(CER 1592) HVHZCompliance NOA 12-0713.02 02/14/2013
Polyglass USA Manufacturing Affidavit Produce Current 02/18/2009
Polyglass USA P/LAffidavit Mule -Hide Cross Ug 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL, U.C. (QUA9625) Quality Control Service Confirmation, 1114571, 2OA Exp.08/08/2015
UL, LLC. (QUA9625) Quality Control Service Confirmation, MTS Plus Exp. 07/O1/2017
4. PRODUCr DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P, is a polyester -reinforced, SBS modified bitumen base sheet.
4.2 Self -Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 Polystick MTS Plus is a nominal 6O-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly -film surface; meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D197O and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced,
With a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/mz polyester
fabric surface; meets TAS 103-
4.2.7 Polyfiex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets.
4.2.8 Dual Pro"' is a nominal 60-mil thick dual-layer.rubberized asphalt waterproofing membrane, fiberglass reinforced, with
a polyester fabric surface.
4.2.9 Tile Pro"' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface.
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets.
4.3.2 Poly flex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation
combined with supporting data forthe prepared roof covering.
Exterior Research and Design, U.C.
cerdJicote ofAurhorlmdon #95e3
PTRINITYIERD
5.4 Allowable roof covers applied atop the underlayments areas follows:
- -. ..
TABLE I:.R00F,COVER OPTIONS „ - ': ' •.. •.. •. -
Underlayment
Asphalt Shingles
Nail -On Tile
Foamdn Tile
Metal
wood Shakes&
Shingles
Slate
Elastubase
yes
Yes
No
Yes
Yes
Yes
ElastobaseP
Yes
Yes
No
Yes
yes
yes
Polystick NITS
Yes
yes
No
yes
Yes
yes
Polyslick NITS Plus
Yes
Yes
No
Yes
Yes
yes
Polystick lR-Xe
Yes
No
No
No
Yes
Yes
PoWck TUP
yes
yes
No
yes
Yes
seeyes
5.Polysdck
TU Plus
yes
Yes
Yes
Yes
Yes
yes
See 5.4.1
Polystick TU Max
No
yes
See yes
No
No
No
Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Tile Pro
yes
yes
yes
yes
Yes
Seeyes5.
-
Elastoflex S6 G
yes
yes
No
Yes
Yes
See 5eS
Elastogex SG FR
Yes
Yes
No
No
yes
Yes
PolyflexG
yes
yes
No
Yes
Yes
Seeyes
Polyflex G FR
yes
yes
No
No
Yes
yes
Polyflex SAP or SAP FR
yes
yes
Seeyes
5.Mule-Hide
No
yes
yes
SA-APP Cap Sheet or SA-
Yes
Yes
yes
No
Yes
Yes
APP Cap Sheet (FR)
see 5.4.1
5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging
data from an accredited testing laboratory is provided.
- ➢ Polyfoam PolyPro AH16D: Polystick TU P, Polystick TU Plus, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA
Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) or Tile Pro.
• 3M"' 2-Component Roof Tile Adhesive AH460: Polystick TU Max
➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
➢ Convenience Products' Touch 'n Seal Stormeond Roof Tile Adhesive: Polystick TU Plus, Polystick TU Max
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern
Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed
to meet wind loads for project).
Note: Polygloss does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB
sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
Exterior Research and Design, I.I.C.
Certlfrcote OfAuthori+odon N9503
Evaluation Report P12060.02.09-R14
FL5259-R39
Revision 14: 07/01/2014
Page 4 of 11
A \)
Qf_�f,RINITY 1 ERD
5.5.2 Bond -to -Insulation:
Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;
Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by aqualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix 1.
5.5.3 Bond to Mechanically Attached Base Laver:
Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -
adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex 56 G or S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Polyflex G or G FR torch -applied to:
➢ Elastobase; Elastobase P or Mule -Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, refer to Section 5.5.4 herein and FRSA/TRI
07320/8-05 or RAS 120.
5.5.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind
uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the
load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI
07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load
resistance based on allowablewind loads. Refer to FBC 1609.1.5 for determination of design wind pressures.
5.5.4.1 Maximum Design Pressure=-90 osf.
Deck: Min. 15/32-inch plywood to meetproject requirements to satisfaction of AHJ.
Primer. (Optional) ASTM D41
Underlayment: Polysdck TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheetand Mule -Hide SA-APP
Cap Sheet (FR), self -adhered.
5.5.4.2 Maximum Design Pressure =-135 osf. `--
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet (FR), self -adhered.
5.5.43 Maximum Design Pressure=-315 osf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer. ASTM D41
Underlayment Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap
Sheet and MuleHide SA-APP Cap Sheet (FR), self -adhered.
5.5.4A Maximum Design Pressure=-622.S psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer. ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
FILE
Exterior Research and Design, LLG Evaluation Report P12060.02.09-R14
Cemiftcate ofAuthoriration #95123 FL5259-R39
Revision 14:07/01/2014
Page 5 of 11
TRINITY i ERD
5.5.4.5 Maximum Design Pressure=-30.0 psf.
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase or Mule -Hide Nail Base (poly -film top surface) mechanically attached with 11 ga. x 1.25-inch long x 1-
inch head diameter round metal cap nails spaced 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2)
equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, PolyFlex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet (FR), self -adhered.
5.5.4.6 Maximum Design Pressure=-37.5 osf.
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase or Mule -Hide Nail Base (poly -film tap surface) mechanically attached with 11 ga. x 1.25-Inch long x 1-
inch head diameter round metal cap nails spaced 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2)
equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, PolyFlex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet (FR), self -adhered.
5.5.4.7 Maximum Design Pressure=-37.5 osf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. One (1) or two (2) layers ASTM D226, Type 11 felt mechanically attached with 11 ga. x 1.25-inch long x 1-inch head
diameter round metal cap nails spaced 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally
spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
5.5.4.8 Maximum Design Pressure=-45 osf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. One (1) layer ASTM D226, Type 11 felt mechanically attached with 11 ga. x 1.25-inch x 3/8-inch head diameter
annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the 2-inch wide side laps and
4-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Polystick TU P, Polystick TU Plus, PolyFlex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet (FR), self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.5.4.9 Maximum Design Pressure=-45
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Two (2) layers ASTM D226, Type II felt mechanically attached with 11 ga. x 1.25-inch long x 3/8-inch head diameter
annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 97inch o.c. at the 2-inch wide side laps and
9-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Polystick TU P, Polystick TU Plus, PolyFlex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet (FR), self -adhered or Elastoflex 56 G, applied in full mopping of hot asphalt.
5.5.4.10 Maximum Design Pressure =-45 osf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced 9-inch o.c. at the 2-Inch wide side laps and 18-inch
o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or PolyFlex G, torch -applied.
5.5.4.11, Maximum Design Pressure=-52.5 psF.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced SlAnch o.c. atthe 2-inch wide side laps and 12-inch
o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or PolyFlex G, torch -applied.
55.4.12 Maximum Design Pressure=-52.5 nsf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase or Mule -Hide Nall Base (poly -film top surface) mechanically attached with Simplex Original Cap Nails
spaced 6-inch o.c. atthe 3-inch wide side laps and 64nch o.c atfour (4) equally spaced staggered center rows.
Undedayment Polystick TU P, Polystick TU Plus, PolyFlex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet (FR), self -adhered.
5.5.4.13 Maximum Design Pressure =-52.5 osf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
mechanically attached with Simplex Original Cap Nails spaced 64nch o.c. at the 3-inch wide side laps and 6-inch o.c.
at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or PolyFlex G, torch-avolied.
Ev
Exterior Research and Design, LLC. Evaluation Report P 6 POLO -R14
Certificate ofAuthadwdon #9503 F1.5759-1119
Revision 14: 07/O1/2014
Page 6 of 11
� I KINFTY ERD
5.5.4.14 Maximum Design Pressure=-60 osf.
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
mechanically attached with 11 ga. x 1.254nch long x 3/8-inch head diameter annular ring shank roofing nails at 1-
5/8-Inch diametertin caps spaced 8-inch o.c. at the 4inrh wide side laps and B-inch o.c. at three (3) equally spaced
staggered center rows.
Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.5.4.15 Maximum Design Pressure=-60 osf.
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch-applled cap)
mechanically attached with OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates spaced 12-Inch o.c. at
the flinch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Undedayment Elasroflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.5.4.16 Maximum Design Pressure=-90 osf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced 6-Inch o.c. at the 2-inch wide side laps and 6-inch
o.c. at two (2) equally spaced staggered center rows.
Undedayment Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
5.5.4.17 Maxim um Design Pressure=-90 osf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
mechanically attached with OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates
or OMG Flat Bottom Metal Plates spaced 6-inch o.c. at the 4-Inch wide side laps and 6-inch o.c. at three (3) equally
spaced staggered center rows.
Undedayment Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
5.5.4.18 Maximum Design Pressure=-90 osf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase (sanded top surface) mechanically attached with Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal
Insulation Plates spaced 6-Inch o.c. at the flinch wide side laps and 6-inch o.c. at three (3) equally spaced staggered
center lows.
Undedayment Elastoflex S6 G, applied in full mopping of hot asphalt.
5.5.4.19 Maximum Design P ressure = -97.5 osf.
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase or Mule,Hide Nail Base (poly -film top surface) mechanically attached with 11 Be. x 1.25-Inch x 3/84nch
head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 4-Inch o.c. at the flinch wide
side laps and flinch o.c. at four (4) equally spaced staggered center rows.
Underlayment Polystick TU P, PolystickTU Plus, Polyflex SAP, PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet (FR), self -adhered.
5.5.4.20 Maximum Design Pressure=-105 osf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced 6-Inch o.c. at the 24nch wide side laps and 64nch
o.c. at three (3) equally spaced staggered center rows.
Undedayment Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.5.4.21 Maximum Design Pressure =-1125 osf.
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase or Mule -Hide Nail Base (poly -film tap surface) mechanically attached with 11 ga. x 1.25-Inch x 3/8-Inch
head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 62inch o.c. at the flinch wide
side laps and 6-inch o.c. atfour (4) equally spaced staggered center rows.
Primer. PG100 or ASTM D41 primer at all tin -caps
Undedayment: Polystick TU P, PolystickTU PI us, Polyflex SAP, PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule -Hide SA-APP
Cap Sheet.(FR), self -adhered.
5.5.4.22 Maxim um Design P ressure = -120 osf.
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torchapplied cap)
mechanically attached with OMG 412 Standard Roofgrip a OMG#14 Heavy Duty with OMG 3" Round Metal Plates
or OMG Flat Bottom Metal Plates spaced 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally
spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, LLC.
Certficote of Authorization #95(13
Evaluation Report P12060.02.09-1114
F15259-R19
FILE'
/
P 7
I
` r TRINITY i ERD
5.5.4.23 Maximum Desien Pressure=-120 Dsf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction ofAHJ.
Base Layer. Elastobase (sanded top surface) mechanically attached with Trufast#12 DP orTrufast#14 HD with Trufast 3"Metal
Insulation Plates spared 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered
center rows.
Undedayment: Elastoflex S6 G, applied in full mopping of hot asphalt
5.5.4.24 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design
Pressure of-45 psf.
5.6 Exposure Limitations:
5.6.1 Elastobase, Elastobase P or Polystick MTS Plus shall not be left exposed for longer than 30-days after installation.
5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after
installation.
5.6.3 Polystick MTS, TU P orTU Plus shall not be left exposed for longer than 180-days after installation.
5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
5.6.5 Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G), in which case the maximum exposure is 180 days.
5.7 For file roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to
the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered
Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof
systems.
:.. r - ...
Ta6tE2:TtE5Y5TEi-n Or'r'ioNS FRSA'jTR107320/g-05
`;_',_ "
PER
_
system
Underlay
Section
Reference
Product(s)
Option
1
2A
Modified Cap Sheet
DastaflexSSG or Elastoflex 56 G Fit; Polyflex G or G FR
Bolt
System One:
2
3.02B
No.30/Modified Cap Sheet
Base layer: Elastobase; EbstobaseP
Top layer. Sastoflex S6 G or Elastonex S6 G FR; PalyflexG or FR
Mechanically Fastened
Tile, Unsealed or
4
3.02D
No. 30
Dastobase; ElartobaseP
Sealed Underiayment
5
3.02E
Self -Adhered Undedaymern
Polystick MTs; Mrs Plus;TUP; TU Plus)TUMax; PolyflexSAPorsAPFR; Mule-
Syrtem
Hide SA-APP Cep sheet or SA-APP Cap sheet (FR); Dual Pro;Tile Pro
N. 30/Self-Adhered
Base Layer. ASTM DUB, Type 11; Mastobase; Mastobase P; Mule -Hide Nail Base
6
3.02E
Underbymem
Top layer. Polystick Mrs; MTS PIus;TUP; TU Plus; TU Max;POlynexSAP or SAP
FR, Mule -Hide SA-APP Cep Sheet or SA-APP Up Sheet (FR); Dual Pro; rile Pro
1
3,02A
Modified Cap Sheet
Elastofiex S6 G or Elastoflex 56 G FR; Polyflex G or G FR
Batten only
5yrtem Two:
2
3.025
No. 3D/ Modified Cap Sheet
Base layer: ElasNbaze; ElaA baseP
Top layer- nastoflex 56 G or Elastoflex S6 G FR; PolyflexG or FR
Mechanically Faztened
Tile,
4
3.02D
Self -Adhered Undeflayment
PolystickTU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Mule -Hide SA-APP Lap
UMeriayment System
Sheet ar SA-APP Cap Sheet (FR); Dual Pro; Tile Pro
No. 30/Self-Adhered
Base layer. ASTM D226, Type 11; Elastabase; Elastobase P; Mule -Hide Nail Base
5
3.02E
Underlaymern
Top layer. Polysd℘ TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide
SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro
1
3.02A
Modified Cap Sheet
DatoflexS6 G or PalynexG
2
3.028
No. 30/ Modified Cap Sheet
Base Layer- Dastabase; El.xtobaseP
System Four 'A':
Top layer. Elactoflax S6 G or Polyflex G
Adhesive-SetTde,
4
3.02D
Self -Adhered Undedayment
Polystick TU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA.
Unsealed orSeated
APP Lap Sheet or SA-APP Cap Sheet (FR)
Underlayment System
Baselayer. ASTM D226, Type 11; Elartaz obe; naxt base P; Mule -Hide Nail Base
6
3.02E
Na.=
TU
TOP Layer: PolystickTU P; TU Plus; Max; Polyflex SAP or SAP FR; Tile Pro;
Underlaymr-Adhered rlaymerd
MuIe-HIde SA-APP Cap Sheet or SA-APP Cap Sheet(m)
1
3.D2A
N.30/ Modified rap Sheet
Base layer. A5TM D226, Type 11; Elestobase; ElastobaseP
Top Layer. Elastaflex S6 G or Polyflex G
System Four 'B':
PolyUpShlP;Tll Plus; TU SAP or SAP FR; Tile Pro; Mule -Hide SA,
Adhesive-SetTile,
3
3.02C
Self -Adhered Undedaymern
Up
APP Cep SheeYar SA-APP Gp Sheet(FR)
Underlaymern
System
No.30/Self-Adhered
No.W/ymarn
Base layer: ASTM D224 Type 11; Elastsbase; Elastobase P; Mule -Hide Nail Base
4
3.02D
Top layer. PolystickTU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pm;
Mule -Hide SA-APP Up Sheet or SA-APP Cap Sheet (FR)
Exterior Research and Design, U.C. . Evalu��akpp6���D��sssrrrrnrll gryp0E:6CRY
Certificpte aJAuthoNzotion #9503
:
Q
TRINITY ERD
6. INSrALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris priorto application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed. .
6.3.2 For use in non -tile applications:
6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be coveted with a layer of Polystick, Poly0ex SAP or SAP FR,
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, ElastoflexS6 G or S6 G FR
in hot asphalt or Polyflex G or G FR, torch applied.
6.3.3 For use in file applications, reference is made to Polyglass published installation instructions in conjunction with
FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, Table 2 herein and Section 5.5.4 herein.
6.4 Polystick MTS, NITS Plus, IR-Xe, TU P, TU Plus, TU Max Polyflex SAP or SAP FR. Mule -Hide SA-APP Cap Sheet or SA-
APP Cap Sheet (FRI, Dual Pro or Tile Pro:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
6.4.2 For non -tile applications:
6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide
Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
- _ The head lap membrane is to cover the area being back -nailed
6.4.2.2 All seal -lap seams (selvage laps) must be firmly
rolled with a minimum 28 lb. hand roller to
ensure full contact and adhesion. For Dual Pro
and Tile Pro, align the edge of the top sheet to
the end of the glue pattern (the sheet will overlap
the fabric).
Yew of Dvelap Seam of Dual Pro and Tile Pro
6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium
Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement,
Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive
Trowel Grade mastic, applied in between the application of the lap.
6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Exterior Research and Design, LLG
Certificate ofAuthorhadon #9503
EvaFhpjrl e EF
�nj Ilfliiii ����Rellllvis��ion 14: 07/01/2�0(14
Page 9 of 11
`.r TRINITY i ERD
i
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing
Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus
Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium
Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area
in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in
place over the repair area. Patch laps, if needed, shall be Installed in a water shedding manner.
6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of
the roof that are not accessible to,a large roller or broom.
6.4.3 For tile applications (not ollowedfor Polystick IRXe):
6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, Table 2 herein and Section 5.5.4 herein, using the instructions noted above as a guideline..
6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.4.3.3 For nail -on tile systems over Polystick MTS Plus:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading%staging of flat tile at slopes in excess of 5:12.
6.4.4 Two (2) Ply Underlayment Systems:
6.4.4.1 Polystick MTS or MTS Plus followed by Polystick MTS, TU P, TU Plus, TU Max, TilePro or Polyflex SAP is allowable for
use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer
material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
6.4.4.2 Polystick MTS Plus followed by Polystick TU P, TU Plus, TU Max, TilePro or Polyflex SAP is allowable for use under
foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6 G or S6 G FR:
6.5.1 Elastoflex S6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table
2 herein.
6.5.2 Elastoflex S6 G or S5 G FR shall be fully asphalt -applied to the substrates noted in Section S.S. Side laps shall be
minimum 3-i6ch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feetfrom course to course.
Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
- 3/8-inch beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein.
6.6.2 Polyflex G or G FR shall be fully torch -applied to the substrates noted in Section S.S. Side laps shall be minimum 3-
inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the
lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8-05 must be used on all
roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to
prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading /staging of the tile.
6.7.4 For nail -on tile systems over Polystick MTS Plus:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12. R
Exterior Research and Design, LLG Evaluation Report P32060.02 09-R14
Certfitate o)AuthodroVon 49503 FL5259-1119
Revision 14:07/01/2014
Page 10 of 11
7.
8.
9.
TRINITY I ERD
6.7.5 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-
eight (48) hours.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 OA requirements.
QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-1134
firoficate ofAathorftaNan 09503 FL5259-R19
Revision 14:07/01/2014
Page 11 of 11
Florida Building Code Online `' }
Page 1 of 3
Flcdda Departfrait4
Busines/l�l
Professi al
Regulation
W
&,..... r
ECIS Home I We In I User RegistaUan Hot Topla I Submit Surcharge I Stats&Facts I Publications I Flic staff i SCIS site Map I Unk I Search
{t(R Gal$) Product Approval
VU USER: Public User
Produd Anpmyal Menu > Product or Aopliation Search > Application List > Appiketion oaten
FL #
FL10490-R3
Application Type
Revision
Code Version
2010
Application Status
Approved
Comments
Archived 171
Product Manufacturer Sunlast Metal
Address/Phone/Email 2120 SW Poma Drive
Palm City, FL 34990
(772) 223-4055
tkapron@suniastmetal.com
Authorized Signature James Buckner
Jimmy@cbuckinc.net
Technical Representative
Address/Phone/Small
Quality Assurance Representative
Address/Phone/Email
�" gY 1ED
,t 1„ BN( unty
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
9 Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the James L. Buckner, P.E. @ C-Buck, Inc.
Evaluation Report
Florida License PE-31242
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2016
Validated By Steven M. Urich, PE
Rl Validation Checklist - Hardcopy Received
Certificate of Independence F1 10490 R3 COI Cer[Oflndeo.odf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL 1897-98 2004
UL 580 with 1998 Revisions 2006
Equivalence of Product Standards
Certified By Florida Licensed Professional Enginee r or Architect
FL10490 R3 Enuiv Test Standard EUUIV oQ qNN
Sections from the Code 'p
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I48z... 3/6/2015
Florida Building Code Online
Page 2 of 3
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
04/19/2012
04/21/2012
05/01/2012
06/11/2012
Mumma or rrocu
ccs
FL#
Model, Number or Name
Description
10490.1
1 - "PBR"
Roof Panel - 26 Gauge Steel, 36" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Installation Instructions
FL10490 R3 II 1 PBR WoodDeck EVALREPORT odf
Verified By: James L. Buckner, P.E P.E. *31242
Created by Independent Third Party: Yes
Design Pressure: +N/A/-76.75
Other: Refer to Evaluation Report for Limitations
and Conditions of Use. Refer to manufacturer's
Evaluation Reports
FI 10490 R3 AE 1 PBR WoodDeck EVALREPORT odf
Created by Independent Third Party: Yes
installation instructions as a supplemental guide
for attachment.
10490.2
2 - "1 in. Nailstnp"
Roof Panel - 24 Gauge Steel, 16" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-306.25
Other: Refer to Evaluation Report for Limitations
and Conditions of Use. Refer to manufacturer's
Installation Instructions
FL10490 R3 11 2 Na'Istrip WoodDeck EVALREPORT ndF
Verified By: James L. Buckner, P.E P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FLLIQ490 R3 AE 2 Na'Ist iv WoodDeck EVALREPORT odf
Created by Independent Third Parry: Yes
Installation instructions as a supplemental guide
for attachment.
10490.3
3 - "1-3/4 In.
Snap Lock" (Steel)
Roof Panel - 24 Gauge Steel, 18" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Installation Instructions
FL10490 R3 II 3 1 75SnapLock WoodDeck EVALREPORT odf
Verified By: James L. Buckner, P.E P.E. #31242
Created by Independent Third Party: Yes
Design Pressure: +N/A/-156.75
Other: Refer to Evaluation Report for Limitations
and Conditions of Use. Refer to manufacturer's
Evaluation Reports
R 10490 R3 AE 3 i 75SnaoLock WoodDeck EVALREPORT.odf
Created by Independent Third Party: Yes
installation instructions as a supplemental guide
for attachment.
10490.4
4 - "1-3/4 in.
SnapLock" (Aluminum)
Roof Panel - 0.032 Aluminum, 14" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-114.25
Other: Refer to Evaluation Report for Limitations
and Conditions of Use. Refer to manufacturer's
Installation Instructions
FL70490 R3 II4 1 75Snaolock Alum WoodDeck EVALREPORT ndf
Verified By: James L. Buckner, P.E P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL10490 R3 AE 4 1.75SnapLock Alum WoodDeck EVALREPORT.gdf
Created by Independent Third Party: Yes
installation instructions as a supplemental guide
for attachment.
10490.5
5 - "copper clad stainless"
Roof Panel - 0.016" Copper -Clad Stainless Steel, 16" Width, Attached
to Plywood Deck w/Optional Rigid Insulation
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-76.75
Other: Refer to Evaluation Report for Limitations
and Conditions of Use. Refer to manufacturer's
Installation Instructions
FL10490 R3 II 5 C000erClaciSta'nless WoodDeck EVALREPORT odf
Verified By: James L. Buckner, P.E P.E. #31242
Created by. Independent Third Party: Yes
Evaluation Reports
FL10490 R3 AE 5 C000e CladSta'nless WoodDeck EVALREPORT pdf
Created by Independent Third Party: Yes
installation Instructions as a supplemental guide
for attachment.
10490.6
6 - "5-V Crimp"
Roof Panel - 26 Gauge Steel, 24" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Installation Instructions
FL10490 R3 11 WoodDeck - OR f
Verified By: lames L. Buckner, P.E 24
Created by Independent Third Party' _
https://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I48z... 3/6/2015
Florida Building Code Online
'11, Page 3 of 3
Design Pressure: +N/A/- Re ' I Evaluation Reports
Other: Refer to Evaluation Report for Limitations FL10490 R3 AE 6 SV WoodDeck EVAI.REPORT.Ddf
and Conditions of Use. Refer to manufacturer's Created by Independent Third Party: Yes
installation instructions as a supplemental guide
for attachment.
10490.7 7 - "Solar V" I Roof I Deck Panel - 26 Gauge Steel, 17-1/2" Width, Attached to Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10490 R3 II 7 SolarV Wo dDeck EVALREPORT. df
Approved for use outside HVHZ: Yes
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/-106.50
Evaluation Reports
Other: Refer to Evaluation Report for Limitations
FL10490 R3 AE 7 SolarV Wood Deck EVALREPORT.Ddf
and Conditions of Use. Refer to manufacturer's
Created by Independent Third Party: Yes
Installation Instructions as a supplem ental guide
for attachment.
-cal Next
Coma .95:: 1940 North Mamma strain. Tallahassee R32399 Phors- 850-487-1824
The State of Flodda Is an AA/� employer. Covvriaht 2007-2013 State of Marcia, :: Pdvscv Statement :: Accessibility Sutan:= :: Refund Statement
Under Borida law, email addresses are public mounds. If you do not want your e-mail address released in response re a public -records request, do not send
electronic mail to this entity. Instead, mntect the office by phone or by traditional mail. If you have any questans, please contact 850.487.1395. `Pursuant to
Section 455.275(3), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public remn1. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click bPte..
Product Approval Accepts:
05 No £ -- CE
SYCYTitti.NfiYNILC
https://www.floridabuilding.orglprlpr_app_dtl.aspx?paratn=wGEVXQwtDqudsDrIH6I48z... 3/6/2015
CBUCK Engln�Prinq
52pe=c1alty Structural EnginPerinq CBUCK, Inc. Certificate of Authorization ti8064
Evaluation Report
"1-31/4" Snap -Lock"
Metal Roof Assembly
Manufacturer:
Sunlast Metal, Inc.
2120 SW Poma Drive
Palm City, FL 34990
(772)223-4055
for
Florida Product Approval
# FL 10490.3 R3
Florida Building Code 2010
Per Rule 9N-3
Method: 1- D
Category: Roofing
Sub - Category: Metal Roofing
Product:
"1-3/4" Snap -Lock" Roof Panel
Material:
Steel
Panel Thickness:
24 gauge
Panel Width:
18"
Support:
Wood Deck
Prepared by:
James L. Buckner, P.E., S.E.C.B.
Florida Professional Engineer#31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 11-190-1.75SL-S4W-ER
Date:2/6/12
Contents:
Evaluation Report Pages 1-8
CBUCK, Inc.
1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403
Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net
FL #: FL 10490.3-R3
\ p q Date: 2 / 6 / 12
RepoCLUCK EngineerinPage rt No.: 2tof 3 vsst-saw-ea
Speelalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Manufacturer: I Sunlast Metal, Inc.
Product Name: "1-3/4" Snap -Lock"
Product Category: Roofing
Product Sub -Category Metal Roofing
Compliance Method: State Product Approval Rule 9N-3.005 (1) (d)
Product/System "1-3/4" Snap -Lock'
Description: 24 gauge Steel roof panel mechanically attached to Plywood Deck with panel Clips
and screws.
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1. Roof Panel
2. Panel Clips
3. Fasteners
4. Underlayment
5. Insulation (Optional)
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of
this evaluation.)
Description:
• 15/32 (min.) or greater plywood,
• or Wood plank (min. specific gravity of 0.42)
Slope: Minimum slope shall be in accordance with manufacturer's recommendations, FBC
Section 1507.4.2 and applicable code sections.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure: METHOD 1:-114.25 PSF
(Referto "Table A" attachment details herein) METHOD 2:-156.75 PSF
FL #: FL 10490.3-113
\/ Date: 2 / 6 / 12
CBVCK EngineeringRepoPagertNo.:3tof31755L-saw-ea
Speelalty Structural Engllm =ring CBUCK, Ina Certificate of Authorization #8064
Performance Standards: The product described herein has demonstrated compliance with:
• UL580-06 — Test for Uplift Resistance of Roof Assemblies
• UL 1897-04 -Uplift test for roof covering systems
• TAS 125-03 —Standard Requirements for Metal Roofing Systems
Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product
assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04
adopted by the Florida Building Code 2010.
Code Compliance: The product described herein has demonstrated compliance with Florida Building
Code 2010, Section 1504.3.2.
Evaluation Report This product evaluation is limited to compliance with the structural requirements
Scope: of the Florida Building Code, as related to the scope section to Florida Product
Approval Rule 9N-3.001.
Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance
with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use"
Rule 9N-3.005(1)(e) allows engineering analysis for "project specific approval
by the local authorities having jurisdiction in accordance with the alternate
methods and materials authorized in the Code". Any modification of the
product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 9N-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA
1824).
I�
FL #: FL 10490.3-R3
Date: 2/6/12
CBUCK Engineering Pagert No.: 4 of 3 vsst-saw-ea
Specialty Structural Enginserinq CBUCK, Inc. Certificate of Authorization #8064
Components/Materials
(by Manufacturer):
Components/Materials
(by Others):
Roof Panel: "1-3/4" Snap -Lock"
Material: Steel
Thickness: 24 gauge (min.)
Panel Width: 18" (max.) Coverage
Rib Height: 1-3/4"
Yield Strength: 40 ksi min.
Corrosion Resistance: In compliance with FBC Section 1507.4.3:
• ASTM A792 coated, or
• ASTM A653 G90 galvanized steel
Roof Panel Clips:
Type: One-piece, fixed clip
Material: Galvanized Steel
Thickness: 24 gauge
Yield Strength: 40 ksi min.
Dimensions: 2.080" (wide) x 3.500" (long) x 1.875" (high)
Corrosion Resistance: Per FBC Section 1506.7
Fastener:
Type: Pancake -Head Wood Screw
Size : #10 x 1-1/2"
Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4
Standard: Per ANSI/ASM E B18.6.4
Underlayment:
Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5
Insulation (Optional):
Type:
Thickness:
Properties:
Density:
Or Compressive Strength:
Rigid Insulation Board
3" (max.)
2.25 pcf (Ibs/ft3) min.
20 psi min.
Insulation shall comply with FBC Section 1508. When insulation is incorporated,
fastener length shall conform to penetrate thru bottom of support a minimum of
3/16".
i � • , k i:'�t c
FL #: FL 10490.3-113
Date: 2/6/12
C®UCK Engineering Page v Report No.: 5 of 3 6st-s4w-ea
SpeclaltLj Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Installation: Installation Method:
(Refer to drawings on Pages 6-8 of this report.)
■ Clip spacing: Refer to Table "A" Below
(along the row, across the panel profile)
• Rib Interlock: Snaplock
(Panel ribs shall be fully engaged to form an integral snap -lock)
• Minimum fastener penetration thru bottom of support, 3/16".
• For panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE "A"
METHOD 1:
METHOD 2:
Design Pressure:
-114.25 PSF
-156.75 PSF
Clip Spacing:
16"
8"
# Fasteners per Clip:
2
2
Install the "1-3/4" Snap -Lock" roof panel assembly in compliance with the
installation method listed in this report and applicable code sections of FBC 2010.
The installation method described herein is in accordance with the scope of this
evaluation report.. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Referenced Data: 1. TAS 125-03 Uplift Test
By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527)
Report #: 0412-0305-07; Test Date: 8 / 7 / 07
2, Quality Assurance
CONCEALED FASTENERS OR ATTACHMEN'
By Keystone Certifications, Inc. (QUA ID:1824)
Sunlast Metal & Solar, Inc. Licensee # 385
ARE THE RESPONSIBILITY OF THE
3. Equivalency of Test Standard Certification
OONTRACTOR Of RECORD
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization #ANE 1916)
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
FL #: FL 10490.3-R3
\Date: 2/6/12
CBUCK EngInPPrinq Page No.: 61of 3 175sL-s4w-ea
Spc=clalFLj Structural Enginoorinq CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Sunlast Metal, Inc.
"1-31/4" Snap -Lock" (24 Gauge) Roof Panel Attached to Wood Deck
Profile Drawings
18A" Coverage
"1-3/4" Snap -Lock' Panel
Typical Panel Profile View
WAD FASTENERS OR AllamEm
mm9�6TOA 9F R�69RD E
CD 7
t�
Typical Panel Clip Profile
I
FL #: FL 10490.3-R3
\ Date: 2/6/12
Report No.: f-vssL-saw-eRC®UCK Enginserinq o3
SpeetaltLj Structural Engtneerinq CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Sunlast Metal, Inc.
"1-3J4" Snap -Lock" (24 Gauge) Roof Panel Attached to Wood Deck
lf:
=11 ►11M
aip:
2 Fasteners per dip
W - �.i
EO.skew I!Ctii
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
Typical Assembly Profile View
Typical Fastening Pattern Across Row
FL #: FL 10490.3-R3
Date: 2 / 6 / 12
CBUCK Engineering Report No.: 81-190-1755L-s4w-ER
Page 8 of 3
Speclalty Structural Engineerinq CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Sunlast Metal, Inc.
"1-31/4" Snap -Lock" (24 Gauge) Roof Panel Attached to Wood Deck
Fasteners:
aNn a,��
-Vibod plank
CONCEALED FASTENERS OR ATTACHMENTS
Typical Assembly Isometric View ARE THE RE8RONSI ivey OF THE
CONTRACTOR OF RECORD
TABLE "A"
METHOD 1:
METHOD 2:
Design Pressure:
-114.25 PSF
-156.75 PSF
Clip Spacing:
16"
8"
# Fasteners per Clip:
2
2
Forensic Engineering Consultants, Inc.
METAL PANEL ATTACHMENT CALCULATIONS
Project Name Keller Williams PGA Sales Center Report No.: ACI-MP-15.001
Project Address 9700 Reserve Boulevard
Port St. Lucie, FL - 34986
Deck Substrate Wood Non -Insulated Mean Roof Height 24.0 Feet
Configuration Steep Slope Roof Area (Approx.) 11648 Sq.Ft.
Category II Roof Width 65.0 Feet
Exposure Condition C Perimeter Width 6.5 Feet
Building Type Enclosed Parapet Height 0.0 Feet
Base Wind Speed 170 mph Sloped Roof Type
Slope V 6.0 Slope H 12.0 Slope Angle° 26.57
Slope V 10.0 Slope H 12.0 Slope Angle° 39.81
Uplift Pressures qz = 0.00256 K� Ka Kd V2 P = q. (GCP - GCP)
q: K. Kt Kd V GCP GCPI
59.230 0.937 1.005 0.85 170 -1.00 0.18 Field
-1.70 0.18 Perimeter
-2.60 0.18 Corner
Field P1 Uh. -69.89 psf P1 asd -41.94 psf
Perimeter P2 Uh. -111.35 psf P2asd -66.81 psf
Corner P3 uIL -164.66 psf P3asd -98.80 psf
Proposed System Sunlast Metal, Inc. 1-3/4" Snap -Lock Metal Panel
Product Approval No. FL 10490.3-R3
Panel Width 18 inches
System Design Pressure-114.25 psf (Field)-156.75 psf (Perimeter/Corner)
Fasteners #10 x 1-1/2" Pancake Head Screws
2 Fasteners per Clip
Max. Clip Spacing per NOA 16 inch (Field) 8 inches (Perimeter) # Rows 1
Clip Withdrawal Resistance-228.50 Ibf (Field)-156.75 Ibf (Perimeter/Corner)
Min. Characteristic Resistance Force-228.50 Ibf (Field)-156.75 Ibf (Perimeter/Corner)
Fastener Spacing f(MCRF/P;) x 144)/(Panel Width/No. of Rows of Fasteners)
Field Fastener Spacing 43.59 inches
Perimeter Fastener Spacing 27.36 inches
Corner Fastener Spacing 18.50 inches
RECOMMENDED FASTENER SPACING
Field 16" o.c.
Perimeter 16" o.c.
Corner 16" o.c.
These calculations have been done in accordance with ASCE 7-10, based on the information provided by the
contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations.
Sincerely
Folic Engineering Consultants, Inc.
R. N. SaiIappan, P.E.
Principal Engineer
Florida Registration No. 46696'
Forensic Engineering Consultants, Inc. (CA #8265). P.O. Box 970034, Boca Raton, FL - 33497 Ph (561) 901 8490 Fax (561) 218 3830