HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: The Island Club Project Address: 10410 S Ocean Drive; Jensen Beach, Florida 34957 SCANNED BY St. Lucie County Permit #: Occupancy Type: R2 Construction Type: Existing INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 2010 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 170 mph _ASD _LRFD End Zone Width: 7.5 ft S. Mean Roof Height 120 ft Roof Pitch: 0 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +1-57 Zone 5: Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: Existing Structure 9. Is A Continuous Load Path Provided? _Yes X Not Applicable Explain Why Not: Existing Structure 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces sped itea?ttll illlll/// `�v�S A..l)AI�Q�%.Charles A Darden Jr, PE 76910 & 29057 �Q ,• y,10ENSF '•• N; Print Name Cert # & Co. Cent Auth. No. 7691V, CSM Engineering, LLC >ignihA *bate, and Seal ��•• STATE OF G(�� �i��C�`O•' • . F<O RID P; . •' •`�,\?� Revised 2081 SE Ocean Boulevard - Suite 1A; Stuart, Florida 34996 Company Name & Address ///// IV[ llltW, Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 aC NNED Certification for Design Load Compliance S' ! ucB COUr1ty Project Name: The Island Club Project Address: 10410 S Ocean Drive; Jensen Beach, Florida 34957 Permit #: Occupancy Type: R2 Construction Typ Existing INSTRUCTIONS FOR USE: *41, ' • This certification must be completed, signed, and sealed by the design professional of record,.., • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the folloai g: o New Residences (single or multi -family) I o Residential Addition o Any accessory structure requiring a building permit t� o Any non-residential structure. ti * Note: Form not required for interior renovations provided that no exterior structural elements are affected and ~ certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 20 10 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 170 mph _ASD _LRFD End Zone Width: 7•5 ft 5. Mean Roof Height 120 ft Roof Pitch: 0 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +/-57 Zone 5: Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: Existing Structure 9. Is A Continuous Load Path Provided? _Yes X Not Applicable Explain Why Not: Existing Structure 5 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Luc' County. I also certify that structural elements depicted on these plans provide adequate resistance to the desiEk forces specifkad1 t t I I IJ I I///// �, .A. DA�doskkl i1 Charles A Darden Jr, PE 76910 & 29057 Print Name Cert # & Co. Cert Auth. y.. , No. 78910 = CSM Engineering, LLC Signi f R Date, and Seal 'Z 2081 SE Ocean Boulevard - Suite 1A, Stuart, Florida 34996 �Q� •, STATE OF V\ Company Name & Address �•.FCORIOP.•' X_ Revised o-0 V%%" ILL