HomeMy WebLinkAboutWIND DESIGN DATAFloor and Roof Live Loads Uninhabitable Attics: 20 psf Habitable Attics, Bedrooms: 30 psf Public Rooms & Corridors: 100 psf Other Areas, Garages: 40 psf Roofs: 20 psf Wind Design Data Ultimate Wind Speed: 176 mph Nominal Wind Speed: 136 mph Risk Category: II Wind Exposure: C Enclosure Classification: Enclosed Internal Pressure Coefficient: 0.18 +/- Components and Cladding Design Pressures: Roofing Zone 1: +30.6 psf max., -75.3 psf min. Roofing Zone 2: +30.6 psf max., -126.3 psf min. Roofing Zone 3: -190.1 psf min. Roofing at Zone 2 Overhangs: -108.5 psf min. Roofing at Zone 3 Overhangs: -178.7 psf min. Stucco, Cladding, Doors & Windows: Zone 4: +75.3 psf max., -81.6 psf min. Zone 5: +75.3 psf max., -100.8 psf min. End Zone Width: 5.50 ft. The Ultimate Wind Speed was used to determine the above Component and Cladding Design Pressures. All exterior glazed openings shall be protected from wind-borne debris as per Section 1609.1.2 of the 2010 Florida Building Code. Geotechnical Information Design Soil Load -Bearing Capacity: Flood Design Data Flood Zone: This table was created using 91ndload Calculator Plus software (1010 Florida Building Code Edition) available from TheFlorldaEngineencom SCANNED BY St. Lucie Countv No. Description Opening Width rn ft) Opening Height (in ) Distancefrom Corner (in ) Design Pressure Requirements 1 3.0 ft. 7.0 ft. 53.0 ft. +71.8 psf, -78.1 psf 2 3.0 ft. 7.0 ft. 53.0 ft. +71.8 psf, -78.1 psf The Ultimate Wind Speed of 176 mph was used to determine the above design pressure requirements.