HomeMy WebLinkAboutWIND DESIGN DATAFloor and Roof Live Loads Uninhabitable Attics: 20 psf Habitable Attics, Bedrooms: 30 psf Public Rooms & Corridors: 100 psf Other Areas, Garages: 40 psf Roofs: 20 psf Wind Design Data Ultimate Wind Speed: 176 mph Nominal Wind Speed: 136 mph Risk Category: II Wind Exposure: C Enclosure Classification: Enclosed Internal Pressure Coefficient: 0.18 +/- Components and Cladding Design Pressures: Roofing Zone 1: +30.6 psf max., -75.3 psf min. Roofing Zone 2: +30.6 psf max., -126.3 psf min. Roofing Zone 3: -190.1 psf min. Roofing at Zone 2 Overhangs: -108.5 psf min. Roofing at Zone 3 Overhangs: -178.7 psf min. Stucco, Cladding, Doors & Windows: Zone 4: +75.3 psf max., -81.6 psf min. Zone 5: +75.3 psf max., -100.8 psf min. End Zone Width: 5.50 ft. The Ultimate Wind Speed was used to determine the above Component and Cladding Design Pressures. All exterior glazed openings shall be protected from wind-borne debris as per Section 1609.1.2 of the 2010 Florida Building Code. Geotechnical Information Design Soil Load -Bearing Capacity: Flood Design Data Flood Zone: This table was created using R"mdoad Calculator Plus software (2010 Florida Building Code Edition) . - ardlable from TheMoridaEngineer corn SCANINED BY St. Lucie Countv No. Description Opening ii rdth rm ) Opening Aei ht (in ) Distancefrom Corner (in ft Desi n Pressure Re uirernents 1 2 3.0 ft. 7.0 ft. 53.0 ft. +71.8 psf, -78.1 psf 3.0 ft. 7.0 ft. 53.0 ft. +71.8 psf, -78.1 psf The Ultimate Wind Speed of 176 mph was used to determine the above design pressure requirements.