Loading...
HomeMy WebLinkAboutMISC EMAILCOOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE (772) 460-7751 FAX (772) 460-4244 EMAIL cookmenard@yahoo.com March 27,2015 SCAN Iv r ._ FILE. COPY St. Lucie County Building Department BY 'Term 1 2300 Virginia Avenue St. LUrip r Ft. Pierce, FL 34982 IS 0 2�— a 35 Re: Parcel: 1436-604-0003-000/7 Door specification prepared for the St. Lucie County Building Dept. for the structure located at 2319 Tamarind Dr. — Unit 103 St. Lucie County, Florida Manufacturer: Therma-Tru Corporation Profiles: Smooth Star Impact Opaque Fiberglass Door FL# 10537.1 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Code: Florida Building Code Residential 2010; Chapter 3 Exposure: C Required Design Pressure: - 61.72 Design Pressure: - 80 Fasteners: %" Itw @ 10.18" Max O.C. & 6" max from each corner: with 1-1/4" minimum embedment, edge clearance 2-1/2", adjacent anchor clearance 3" The above approved, as per Florida Building Code Compliance acceptances, 2010 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted, Peter B. Cook Cook & Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789