HomeMy WebLinkAboutMISC EMAIL_._COOK & ME-. ,UM ARCEIITECTI. ZE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE (772) 460-7751 FAX (772) 460-4244
EMAIL cookmenard@yahoo.com
March 27, 2015 FILE, COP I
St. Lucie County Building Department /O r
2300 Virginia Avenue '7
Ft. Pierce, FL 34982 h5 O 3- O 53 (o•
Re: Parcel: 1436-604-0001-000/3 Door specification prepared for the St. Lucie County Building Dept.
for the structure located at 2319 Tamarind Dr. — Unit 101 St. Lucie County, Florida
Manufacturer: Therma-Tru Corporation
Profiles: Smooth Star Impact Opaque Fiberglass Door FL# 10537.1
Wind Speed: 165 MPH; Ultimate Design Wind Speeds
Code: Florida Building Code Residential 2010; Chapter 3
Exposure: C
Required Design Pressure: - 61.72
Design Pressure: -80
Fasteners: Y" Itw @ 10.18" Max O.C. & 6" max from each corner: with 1-1/4" minimum
embedment, edge clearance 2-1/2", adjacent anchor clearance 3"
The above approved, as per Florida Building Code Compliance acceptances, 2010 Florida Building Code, and the
Manufacturer's recommendations.
Respectfully Submitted, SCANNED
BY
/ St. Luce County
Peter B. Cook
Cook & Menard Architecture, Inc.
Florida Registration No. AA0003494, NCARB Certification No. 31789