.NOTICE OF ACCEPTANCE (NOA) wwrv.mlamtdedc.eoy/economy
GAF
1361 Alps Road
Wayne, NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes, if this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building coda.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:: GAF RuberoideModitied Bitumen Roof System for Wood Decks
)LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMLNATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
JFSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0424.14 and consists of pages t through 29.
'lice submitted documentation was reviewed by Jorge L. Acebo.
rVJ
< • APPaDYED
NOA No.:14-0611.01
Expiration Date: 11/06/15
Approval Date: IIJ06114
Page I of 29
£'d £bb929h2LLT:01 :WONA U9£:OT ST02-9T-Nnf
Fastening Any of above anchor sheets attached to deck approved annular ring shank nails
Options: and 3" inverted Drill-Tec' insulation plates at a fastener spacing of 9" o.c. at the
(Continued) 4" lap staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psj. See General Limitation #7)
GAFGLASe #75 Base Sheet or any of above anchor sheets attached to deck with
Drill -Teo " #12 Fastener, Drill-Tec' # 14 Fastener or Drill-Tec7 XHD Fastener
and Drill -Teo'" 3" Steel Plate, Drill-Tec'" AccuTrace Flat Plate or Drill-Tcr
AccuTraco Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure —75 psj See General Limitation #7)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
EnergyGunrd'" Polyiso Insulation, EnergyGuard7 Polyiso RA Insulation,
EuergyGuar(r Polyiso RN Insulation, EnergyGuard" RA Composite Polyiso Insulation
Minimum 1" thick N/A N/A
Structodek® High Density Fiber Board, EnergyGuardm Perlite Recover Board
Minimum'/," thick N/A N/A
EnergyGuard'" Perlite Roof Insulation
Minimum'/a" thick
N/A
NIA
Note: All insulation shall be adhered to the anchor sheet in full, mopping of approved hot asphalt
within the EVT range and at a rate of 20-40 lbsJ100 fe. Please refer to Roofing Application
Standard RAS 117 for insulation attachment, Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocynnurate side facing down. GAF requires either a ply of GAFGLAS® Stratavene
Eliminator'" Perforated Venting Base Sheet laid dry or a layer of EnergyGuard Perlite Roof
Insulation or wood fiber overlay board on 211 polyisocynnurate applications.
Base Sheet: (Optional) Install one ply of GAFGLAS'® 475 Base Sheet, GAFGLAS® #80
Ultima' Base Sheet, GAFGLAS' Ply 4, GAFGLAS FlexPly' 6, GAFGLAS®
Stratavente Eliminator Perforated Venting Base Sheet (laid dry), Ruberoide Mop
Smooth, Ruberoide 20, Ruberoid® SBS Heat-Weldd' Smooth or Ruberoid® SBS
Heat -Weld'" 25 directly over the top layer of insulation. Adhere with any
approved mopping asphalt applied within the EVT range and at a rate of 2040
lbs./sq. (See General Limitation 44).
Ply Sheet: (Optional) One or more plies GAFGLASe Ply 4, GAFGLAS® FlexPly— 6,
GAFGLASe #80 Ultima Base Sheet, Ruberoid® Mop Smooth, Ruberoid® 20
adhered in a full mopping of approved asphalt applied within the EVT range and
at a rate of 2040 lbs./sq.
Membrane: One or more plies of Ruberoid® 20, Ruberoide 30, RuberoideEnergyCap 30 FR
SBS Membrane, Ruberoide 30 FR, Ruberoide Mop Smooth, Ruberoid®Mop 170
FR, RuberoideMop Granule, RoofMatch'" SBS Modified Granular, Ruberoid®
Mop Plus, Ruberoid® Mop FR or Ruberoide Dual FR fully adhered in an approved
asphalt at an application rate of 25 IbJsq. t 15%.
NOA No.: 14-0611.01
MIW* WEeourrry Expiration Date: 11/06/15
♦U Approval Date: 11/06/14
Page 8 of29
b'd £b6929b2LLT:01 :WMIA UL£:0T ST02-9T-Nnr
DESIGN LOAD CRITERIA
0 516N LOADS PER THE FLORIDA EXISTING EWIlDINS CODE, 2010 EDITION
DESIGN CRITERIA PER ASCE T
ULTIMATE WIND SPEED REGION, V(Ult)—._._._.ITO MPH
N MIIN✓ L K SPEEDBOPM DEBRIS REGION
V((a5d) .. •_-•_..132 MPH
BUILD SEHD5T � < 40 Fi
ROOF
6
0RY II
INTERNAL PRESURE COEFF. t 0.15
EXPOSURE B
HEIGHT 4 EXPOSURE COEFF. LOCI
Elm ZONE 15 WITHIN A DISTANCE OF
kd = 4 FT FROM BUILDING CORNERS. II��
FASTENER SCHEDULE PER 10 LINEAR FT
ZONE
DE516N
PRE55URB
NO. OF
FASTENERS
ALLOWABLE
PRESSURES
FA57M SPA([W
4' LAP
FIELD
1
34
3q
-60
W OL.
(2) STA66ERED ROWS 9 q' Of,.
2
5T
5q
-60
q' OL.
(2) STAGGERED ROWS 0 q' Of,.
g
8b
60
q2
b' OL.
(?) STAGGERED ROWS a b' OL.
CALCULATIONS FOR OAF RUBEROID M)DIFIED BITUIJIEN ROOF SYSTEM FOR WOOD DECKS
GAFGLA9 960 BASE SHEET ATTACHMENTS UNDER TILE ROOF (RDA NIL M-001L01 EXPIRES U/e/151
CALCULATIONS BASED OR THE ROOFING APPLICATION STANDARD (RAG 1117) GENERAL LIMITATION 47
A) ICM A OF FASTENERS = LHO OM 8 OF FASTENERS
MAX. DESIGN PRESWRE ELEVATED DESIGN PRE55LRE
B) FASTEN BASE SHEET WITH APPROVED AMAR RING SHANK NAILS AND TIN GAPS
C) KNOWN q OF FASTENERS PER 10 LRL FT= 34 Mm OL. 0 THE 4' LAP 4 (2) STA66MW ROWS 0 q' OL. IN FIELD)
MAX DE516N PRESSURE _ —60 PSF A5 PER NOA
ZONE 1 A 2
USE 3q FASTENERS PER 10 LINEAR FEET
ZONE 3
USE 60 FASTERS PER 10 LINEAR FEET
33 = X
86
X . 55.4 FASTENERS ALLOWABLE UPLIFT -42 PSF > REAIO -66 P5F ,,,j0e �eeeee
ANCHOR SHEET SHALL BE FASTENED • 6' O.C. IN THE LAP 4 TWO STAf 6ERED ROWS • 6.OL. ��`P�` A N NO°0�eo'
ENTEGRA ROOF TILE BELLA 'HIGH S' TILE INOA %0414.06 EXPIRES 7/13/18) E pI J-
Re011MIED RESISTANCE UPUFT MOMENT BASED ON FRSA/TRI TABLE 4A aru
FASTENED W/ SIR 2-CORIPONEHT FOAM ROOF TILE ADHESIVE AH-180
mAximsisTANZED
REmiREO RESISTANCE
ATTAasmw
665 FTAEF
1 2112 FT-LBF
LARGE PATTY 4 N RINSSHANK W41L
C
•I
:.G
a'�
(�ST.LUCIE
16rir ENGINEEPING. INC..%
CATHOLIC CHURCH
PARRISH HALL -425SWIRVINGST.
PORT ST. LUCIE, FLORIDA
-
3.27-15
«rdlfddw�o..�«n,
wowm of Ml. Enelm°rIr10, lm.
v��la�•m,aa,�a.,l,a°.+a
a mry cvrETlO�aroT, •YMW aNrOL
.roexu
15-134
`ConsuNng5rcuc1uta1E�lgltUor.
xwo atmno.nuo
Vw OweR Fk ��VEO
""ajib lml f�i19659.°GI
OGWN OY. CIQC®AI:
TR -
cOn.°N orpmnuuionWllN apinpo�ry
oc.�uaa.mw cswim. anm�w
my marnwte nerourorumeclw,
1 :CALCS FOR ROOF ATTACH; TILE ROOF
fND� SK-2 a 2 air
by ^^L enel�oo.lnv. tr+o.
S'cl £b7929b2LLT:01 :WOa9 HL£:0T ST02-9T-NIIf
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACC
Entegra Roof Tile, Inc.
1299 NE 90 Ave.
Okeechobee, FL. 34972
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11905 SW 26 Street, Room 208
Miami, Florida 33175.2474
T (786) 315.2590 F (786) 315-2599
wmr.minmldade,env/bulldbta/
SCANNED
BY
St Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County HNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ)_
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expanse of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to
revoke this acceptance, if it is determined by Miami-Dado County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
IDESCAlkno : Bella 11I11gh 5" File
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "MiQml-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product,
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews NOA # 09-0512.15 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
ask_: iA¢PAQY•ED._=
NOA No.:11-0414.08
Expiration Date: 07/13/16
Approval Date: 06/02/11
Page 1 of
9'd 2b6929b2LLT:01 :W02id H8£:0T ST02-9T-Nnr
ROOFING ASSEMBLY APPROVAL
Ca e o
Roofing
Cub-Catettory
Roofing Tiles
Material:
Concrete
et
Wood
1. SCOPE
This approves a roofing system using Entegra Bella "High S" concrete roofille as manufactured in
Okeechobee, FL and described in Section 2 of this Notice of Acceptance. For locations where the
pressure requirements, as determined by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in
section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
manufactured by Teat Product
Aopliepot Dimensions SoWAReatlons DescriRtlon
Bella "High S" L= 16'G"
TAS 112 High profile, interlocking, extruded concrete
W = 13-'/4"
roof tile equipped with two nail holes. For
Thickness = K"
mechanical, mortar or adhesive set
applications.
Trim Pieces 1= varies
TAS 112 Accessory trim, concrete roof pieces for use at
w = varies
hips, rakes, ridges and valley terminations.
varying thickness
2.1 1L4NUFACTURING LOCATION
2.1.1. Okeechobee, FL.
2.2 EVIDENCE SUBMITTED
Test Aacv_
Teet Identifier
Test Nume/Report
Date
IBA Consultants, Inc.
2421-94
ASTM C 1167
June 2006
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix Ill
TAS 102 Bc 102(A)
Redland Technologies
Letter Dated Aug. 1,
Wind Tunnel Testing
Aug. 1994
1994
TAS 108 (Nail -On)
Redland Technologies
P09647-01
Wind Tunnel Testing
Aug. 1994
TAS 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance
Sept. 1993
Testing of screw vs, smooth
shank nails
NOA No.: 11-0414.08
Lrxpiratton Date: 07/13/16
Approval Date: 06/02/11
Page 2of7
L'd £b6929b2L1LT:01 :WOad H8£:01 SL02-9L-Nnr
The Center for Applied
94-083
Static Uplift Testing
April 1994
Engineering, Inc.
TAS 101 (Adhesive Set)
The Center for Applied
94-084
Static Uplift Testing
May 1994
Engineering, Inc.
TAS 101 (Mortar Set)
The Center for Applied
25-7094-(3, 6 & 9)
Static Uplift Testing
Oct. 1994
Engineering, Inc.
TAS IO2
The Center for Applied
25-7120.(1 & 2)
Static Uplift Testing
Nov. 1994
Engineering, Inc.
TAS 102
The Center for Applied
25-7183-(3 & 4)
Static Uplift Testing
Feb. 1995
Engineering, Inc.
TAS 102
The Center for Applied
25-7214-(3, 4, &7)
Static Uplift Testing
March,1995
Engineering, Inc.
TAS 102
The Center for Applied
25-78044
Static Uplift Testing
Sep. 1996
Engineering, Inc.
TAS 102
Colotex Corporation
520111-3
Static Uplift Testing
Dec.1998
Testing Services
TAS 101
CelotexCorporation
520191-2-1
Static Uplift Testing
March 1999
Testing Services
TAS 101
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
Walker Engineering, Inc.
Calculations
Restoring Moment
June 2007
3. LiMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS
106 may required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix 'A', Such testing shall be submitted to
the Building and Neighborhood Compliance Department — Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 heroin.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with applicable building code.
NOA No.: 11.0414.08
Expiration Date: 07/13/16
Approval Date: 06/02/11
Page 3 of
e'd £b6929b21LT:01 :WOad ti6£:OT ST02-9T-Nnf
4. INSTALLATI®Pi
4.1 Entogra Sales, Inc.'s Bella "High S" concrete roof the and its components shall be installed
in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profllo
Weight-W (Ibf)
Longth-1(R)
Wldth-w (ft)
Bella "High S" Tile
10.5
1 1.376
1.08
Table
2: Aerodynamic Multi Ilere -A ft
Tile
Profile
A ( )
Batten Application
A (ft )
Direct Deck Application
Bella "High S" Tile
0.349
0.378
Table 3: Rauturing
Moments due
to Gravity - Ma 4ft-lb
Tile
Profile
2":12"
3":12"
4":12"
611:12"
811:12"
Greater than
T':12"
Bella "High
S" Tile
Battens
Direct
I Deck
Battens
I
Direct
I Deck
Battens
I
Direct
I Deck
Battens
I
Direct
I Deck
Battens
Direct
Deck
Battensl
Direct
I Deck
6.18
1 6.89
1 6.11
I 8.e0
I 6.99
1 6.67
1 5.85
6.51
5.68
1 8:33
6.60
1 .13
Table 4: Attachment Realatanco Expressed As a Moment - Mr (ftdbf)
for Nail -On Systems
Fastener Type
Direct Deck
(min 15132" plywood)
Direct Deck
(min.19/32" plywood)
Battens
F"aHlegh
2-10d Rin Shank Nails
28.6
41.2
19.4
1-10d Smooth or Screw
Shank Nail
6.1
16;8
2.8
2-10d Smooth or Screw
Shenk Nails
6.9
9.2
7.3
1 #8 Screw
20.7
20.7
18.1
2 08 Screw
43.2
43.2
29.8
1-10d Smooth or Screw
Shank Nail Field Clip)
23.1
23.1
19.0
1-10d Smooth or Screw
Shank Nail Eave Clip)
29.3
29.3
24.0
2-10d Smooth or Screw
hank Nslls Field Cli
27.6
27.6
38.6
2-10d Smooth or Screw
Shank Nails Eave Clip)
38.1
38.1
41.8
2-10d Rin Shank Nails 33.1 48.1 50.9
1. Installation
with a 4" the headlaP and fasteners are located a min. of 2W from head of file:
�I'NRUVEU
NOA No.: 11-0414.09
Expiration Date: 07/13/16
Approval Date: 06/02/11
Page 4 of 7
6'd £6692962L1T:01 :WMJd ti6£:0T ST02-9T-Nilf
Table 5: Attachment Resistance Expressed as a Moment Mr (ft-lbf)
forTvio Patty Adhesive Set >3 stems
Tile
Tito Application
minimum Attachment
I
Profile
Resistance
Bella "High S" Tile
Adhesive
29.3
1 See me urecturea component: approval for Installation r uiremente.
2 Flexible Products company Tllasond Average weight per patty 10.7 grams.
Polyfoarn Product Ino. Average weight Ear patty 0 atoms.
Table 6: Attachment Resistance Expressed as a Moment - flit (ft-lbf)
for Sin le_Eg_q Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Bella "High S" The
lyfoam Pol ProTm
68.6
Polyfoam Pol ProTm
38.74
3 Le e e lecementof83 rams of Pal ProT^`.
4 Medium a Iacement of 24 tame of Pol Prow.
Table 7: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
for Mortar Set Systems
Tile
Profile
Tile
A Ilcetlon
Attachment
Resistance
Belle "High $" The
Morten Set
24.5
6 Tlle•Tite Roof Toe Mortar.
uraaoeEo =t-�r ;*
NOA No.:11-0414.08
Expiration Dale: 07/13/16
Approval Dale: 06/02/11
Page 5 of 7
0T'd £b69Z962LLT:01 :WOad b6E:OT ST02-9T-Nnf
S. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
seen in detail below, or following statement: "Miami -Dade County Product Control
Approved".
OR
ENTE(BRA SALES BELLA "HIGH S" CONCRETE TILE LABEL
(LOCATED UNDERNEATH TILE)
6. BUILDING PEIBMff REQUMEMEN'I'S
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.E Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
4.P�A'OVE4. _
NOA No.: 11-0414.08
Espiratlon Date: 07113/16
Approval Date: 06/O2/11
Page 6 of 7
TT'd £b6929t7222T:01 :WOad Wt0 :OT ST02-91-Nnf
PROFILE DRAWING
M M
END OF THIS ACCEPTANCE
nreeeYm -
NOA No.: 11-0414.08
Expiration Data: 07/13/16
Approval Date: 06/02/11
Page 7 of 7
2T'd £0t,929b2LLT:01
:WONJ H0t,:OT ST02-9T-Nnr
APPROVED ASSEMBLIES
Membrane Type:
SBS
Deck Type 11:
Wood, Insulated
Deck Description:
19132" or greater plywood or wood plank
System Type A(1):
Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt
All general and System Limitations shall apply.
Fire Barrier:
FireOut Fire Barrier Coating,VersaShieieFire-Resistant Roof Deck Protection
(optional)
or Securoce Gypsum -Fiber Roof Board.
Anchor sheet:
GAFGLAS® 480 Ultimo Base Sheet, GAFGLAS® Stratavene Eliminator
Nailable Venting Base Sheet, Ruberoid® 20, RuberoiO SBS Heat -Weld Smooth
or Ruberoid® SBS Hcat-Weld„ 25 base sheet mechanical ly fastened to deck as
described below.
Fastening
GAFGLAS® Ply 4, GAFGLAS® FlexPlyw 6, GAFGLAS® 075 Base Sheet or any
Options:
of above anchor sheets attached to deck with approved annular ring shank nails
and tirmaps at a fastener spacing of 9" o.c. at the lap staggered and in two rows
12" o.c. in the field.
(Maximum Design Pressure -45 psf. See General Limitation #7)
GAFGLAS® Ply 4, GAFGLAS® FlexPly 6, GAFGLAS®#75 Base Sheet or any
of above anchor sheets attached to deck with Drill -Terry 412 Fastener, Drill -Terry
414 Fastener or Drill -Terry XHD Fastener and Drill -Terry 3" Steel Plate, Drill -
Tee ry AccuTrae Flat Plate or Drill -Tee AccuTrac Recessed Plate installed 12"
o.c. in 3 rows. One row is in the 2" side lap, The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure-45 psf. See General Limitation #7)
GAFGLAS® FlexPlyry 6, GAFGLAS® #75 Base Sheet or any of above anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure-S2.5 psf. See General Limitation #7)
GAFGLAS®#80 Ultimary Base Sheet, Ruberoid®20, Ruberoiemop Smooth base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure -60 psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with
Drill-Tec' 412 Fastener, Drill-Tee414 Fastener or Drill-Tec" � XHD Fastener
and Drill -Terry 3" Steel Plate, Drill -Terry AccuTrado Flat Plate or Drill-Tec'
AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side
lap. The other rows ate equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure-60 psf. See General Limitation 97)
NOA No..,14-0611.01
Expiradon Date: 11/06/15
Approval Dote: MOM
Page 7 of 29
£T'd £bb9296221 1:01 :140NA H0t7:0T ST02-91-Nnr
i
WOOD BECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAe Ply 4 and GAFGLAe Fle%Ply Tm 6 when used as a
mechanically fastened base or anchor sheet. X gypsum board is acceptable to be installed
2. Minimum 1/4"DensDeck® Roof Board or'/," Type
directly over the wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shal I be 4' x 4' maximum. applications over closed cell
4. An overlay and/or recovery board insulation panel is required on all
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every IZ .in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to a maximum
design pressure of 45 psf. value of
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F)
2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 Ibf insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by ELFlorida Registered
Engineer, Architect, or Registered Roof Consultant maybe submitted. Said revised fastener spacing
shal I utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
Compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(Wlten'this limitation is spedncany referred within this NOA, General Limitation 99 will not
be applicable.)
8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS l 11 and applicable wind load requirements.
9. The maximum designed pressure. limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers).
(When this limitation is speeffically referred within this NOA, General Limitation #7 win not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-0611.0 t
Ezpirstian Date: 111061IN
tsartwanec Approval Date: 11/06/14
Page 29 of 29
bt'd £bb929b2LLL:0i :WONJ tl0t7:0S S102-9T-Nflf
"0
MIMIAMI, EME I
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
OF
Entegra Roof Tile, Inc.
1289 NE 9t° Ave.
Okeechobee, FL. 34972
SCOPE:
BUILDING DIVISION
REVIEWED
FOR COMPLIANCE.
REVII
DATE
MUST BE KEPT ON JOB
NO I SPE TIQN WILL BE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
�--� www.miamidade.eov1lmildhrel
BCANNEI
BY
St. Lucie &
This NOA is being issued under the applicable of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction .
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
(DESGRIPrTION: Bella" iih S:tTHe FILE
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application. has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
CONCEALED FASTENERS OR ATTACHIdM
TM.* NOA # 09 0512 15 d f 1 thr 7
s renews - . an consrsts o pages ough
The submitted documentation was reviewed by Alex Tigera.
ARE THE RESPONS�9�LI1Y OF THE
THESE Pj2d �L ORP PoSf10 WORK
CONiRACTOROFRECORD
NOA Na.: 11-0414.08
MIAMAQADECOUNTr AFE SUBJECT 0 ANY COF3SgECTIONS
Expiration Date: 07/13/16
REQUIRED BY MELD 1NSPSCIORS THAT
Approval Date:Page
MAY BE NECi:Smy im ()no '9 TO
1 o/f7
COMPLY WITH ALL APPLICABLE CODES.
so
DESIGN LOAD CRITERIA
DESIGN LOADS PER THE FLORIDA EXISTING BUILDING CODE, 2010 EDITION
DESIGN CRITERIA PER ASGE'I
ULTIMATE WIND SPEED REGION, V(ult)_.-.__--ITO MPH
NOMINAL WIND SPEED REGION, V(ascU__.- .._..132 MPH
WIND BORNE DEBRIS REGION
ENGL05W STRUCTURE
BUILDING HEIGHT < 40 FT
RR15K GA PITCTE60RY b II
INTERNAL PRE55URE GOEFF. t OJ8
EXPOSURE B
HEIGHT 4 EXPOSURE GOEFF. I.Oq
END ZONE 15 WITHIN A DISTANCE OF
(o) = q FT FROM BUILDING CORNERS.
FASTENER SCHEDULE PER 10 Ll�
CALCULATIONS FOR GAF RUBEROUY MODIFIED BITUMEN ROOF SYSTEM FOR WOOD DECKS
GAFGLAS 180 BASE SHEET ATTACHMENTS UNDER TILE ROOF INOA No. 14-08ri01 EXPIRES 11/6/15)
CALCULATIONS BASED ON THE ROOFING APPLICATION STANDARD (RAS 1fl) GENERAL LIMITATION /7
YL.. ►/Y .1 d.Wr. i� : :r � r � ��rr.:�
B) FASTEN BASE SHEET WITH APPROVED ANNULAR RING SHANK NAILS AND TIN GAPS
C) KNOMAI I OF FASTENERS PER 10 LIN FT: 34 (q' O.C. 0 THE 4' LAP 4 (2) 5TAJW ROWS ® q' OL. IN FIELD)
MAX DESIGN PRE55URE = -60 P5F AS PER NOA
ZONE 1 & 2
USE 3q FASTENERS PER 10 LINEAR FEET M
ZONE 3
USE 60 FASTENERS PER 10 LINEAR FEET
.'r m1n;:-
r
AR 31701g
S1• ` < N
A11)
?/
e CG4nrY, F(
ALLOWABLE UPLIFT -q2 P5F > REGD -86 PSF
ANCHOR SHEET SHALL BE FASTENED o 6' OL. IN THE LAP 4 TWO 5TA66ERED ROMS ® b' OL.
ENTEGRA ROOF TILE BELLA 'HIGH S' TILE (NOA 114414.08 EXPIRES 7/13/10)
REQUIRED RESISTANCE UPLIFT MOMENT BASED ON FRSA/TRI TABLE 4A
FASTENED W/ 3M 2-COMPONENT FOAM ROOF TILE ADHESIVE AH-160
CALCULATIONS FOR GAF RUBEROUY MODIFIED BITUMEN ROOF SYSTEM FOR WOOD DECKS
GAFGLAS 180 BASE SHEET ATTACHMENTS UNDER TILE ROOF INOA No. 14-08ri01 EXPIRES 11/6/15)
CALCULATIONS BASED ON THE ROOFING APPLICATION STANDARD (RAS 1fl) GENERAL LIMITATION /7
YL.. ►/Y .1 d.Wr. i� : :r � r � ��rr.:�
B) FASTEN BASE SHEET WITH APPROVED ANNULAR RING SHANK NAILS AND TIN GAPS
C) KNOMAI I OF FASTENERS PER 10 LIN FT: 34 (q' O.C. 0 THE 4' LAP 4 (2) 5TAJW ROWS ® q' OL. IN FIELD)
MAX DESIGN PRE55URE = -60 P5F AS PER NOA
ZONE 1 & 2
USE 3q FASTENERS PER 10 LINEAR FEET M
ZONE 3
USE 60 FASTENERS PER 10 LINEAR FEET
.'r m1n;:-
r
AR 31701g
S1• ` < N
A11)
?/
e CG4nrY, F(
ALLOWABLE UPLIFT -q2 P5F > REGD -86 PSF
ANCHOR SHEET SHALL BE FASTENED o 6' OL. IN THE LAP 4 TWO 5TA66ERED ROMS ® b' OL.
ENTEGRA ROOF TILE BELLA 'HIGH S' TILE (NOA 114414.08 EXPIRES 7/13/10)
REQUIRED RESISTANCE UPLIFT MOMENT BASED ON FRSA/TRI TABLE 4A
FASTENED W/ 3M 2-COMPONENT FOAM ROOF TILE ADHESIVE AH-160
MAX RESISTANCE
REGNIIRED RESISTANCE
ATTACHMENT
665 FT-LBF
2q2 FT-LBF
LARGE PATTY 4 (U RINS%M NAIL
��.nu>►�ryr
PEG AN rly
No 0
A
-
M.ENGINEERING; INe.
ST. LUCIE CATHOLIC CHURCH
pARRISH HALL - 425 SW IRVING ST.
PORT ST. LUCIE, FLORIDA
- - _
mnotue - -
32715
,nl,�,l!da,I�a�wanwro�
Rep "Ildr
w mry camml vceroln, wunoNem,®
n��.d•��
meN. mE mw Ea umlxllo legm acorn
15-134
[ Consulting Slruclurd Engineer
2030 371h AmiiIx ' °
Vem Baucn. FbAtla 329E0,
Fl�mio )i26dV.1]6) {mc1R669A0I1
°° m M. TR CNC w.
➢IIE
CALCS FOR ROOF ATTACH: TILE ROOF
flREi lA:
SK-2 ., 2 mm
bV ML En9lnaarin0. Ina.'
N M
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Roofing Tiles
Material:
Concrete
Deck Tyne:
Wood
1. SCOPE
This approves a roofing system using Entegra Bella "High S" concrete roof tile as manufactured in
Okeechobee, FL and described in Section 2 of this Notice of Acceptance. For locations where the
pressure requirements, as determined by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in
section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
Bella "High S"
L = 16 %"
TAS 112
High profile, interlocking, extruded concrete
W = 13 'I'
roof tile equipped with two nail holes. For
Thickness = %z"
mechanical, mortar or adhesive set
applications.
Trim Pieces
1= varies
TAS 112
Accessory trim, concrete roof pieces for use at
w = varies
hips, rakes, ridges and valley terminations.
varying thickness
2.1 MANUFACTURING LOCATION
2.1.1. Okeechobee, FL.
2.2 EVIDENCE SUBMITTED
Test Agency
IBA Consultants, Inc.
Redland Technologies
Redland Technologies
Redland Technologies .
Redland Technologies
Test Identifier
2421-94
7161-03
Appendix III
Letter Dated Aug. 1,
1994
Test Name/Reyort
ASTM C 1167
Static Uplift Testing
TAS 102 & 102(A)
Wind Tunnel Testing
TAS 108 (Nail -On)
P09647-01 Wind Tunnel Testing
TAS 108 (Mortar Set)
P0402 Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Date
June 2006
Dec. 1991
Aug. 1994
Aug. 1994
Sept. 1993
NOA No.: 11-0414.08
MuuNb ECOU TY Expiration Date: 07/13/16
• • • e i Approval Date: 06/02/11
Page 2 of 7
N
M
The Center for Applied
94-083
Static Uplift Testing
April 1994
Engineering, Inc.
TAS 101 (Adhesive Set)
The Center for Applied
94-084
Static Uplift Testing
May 1994
Engineering, Inc.
TAS 101 (Mortar Set)
The Center for Applied
25-7094-(3, 6 & 9)
Static Uplift Testing
Oct. 1994
Engineering, Inc.
TAS 102
The Center for Applied
25-7120-(1 & 2)
Static Uplift Testing
Nov. 1994
Engineering, Inc.
TAS 102
l The Center for Applied
25-7183-(3 & 4)
Static Uplift Testing
Feb. 1995
Engineering, Inc.
TAS 102
The Center for Applied
25-7214-(3, 4, &7)
Static Uplift Testing
March, 1995
Engineering, Inc.
TAS 102
The Center for Applied
25-7804-4
Static Uplift Testing
Sep. 1996
Engineering, Inc.
TAS 102
Celotex Corporation
520111 3
Static Uplift Testing
Dec. 1998
Testing Services
TAS 101
Celotex Corporation
520191-2-1
Static Uplift Testing
March 1999
Testing Services
TAS 101
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
Walker Engineering, Inc.
Calculations
Restoring Moment
June 2007
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS
106 may required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A', Such testing shall be submitted to
the Building and Neighborhood Compliance Department — Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
O unless stated otherwise by the underlayment material manufacturers published literature.
3.6 DThis acceptance is for wood deck applications. Minimum deck requirements shall be in
® compliance with applicable building code.
y
NOA No.:11-0414.08
Expiration Date: 07/13/16
Approval Date: 06/02/11
Page 3 of 7
M
4. INSTALLATION
4.1 Entegra Sales, Inc.'s Bella "High S" concrete roof tile and its components shall be installed
in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Welght-W (lbf)
Length-1(ft)
Width-w (ft)
Bella "Hi h S" Tile
10.5
1 1.375
1.08
Table
2: Aerod namic Multipliers -A ft
Tile
Profile
A ( )
Batten Application
A (ft )
Direct Deck Application
Bella "High S" Tile
0.349
0.378
Table 3: Restoring
Momenta due
to Gravity - M
ft-Ib
Tile
Profile
2":12"
VAX'
I
V%12"
6":12"
6":12"
I
Greater than
T"" :12
Bella "High
S" Tile
Battens
I Direct
I Deck
I Battens
I
Direct
I Deck
Battens
I
Direct
Deck
Battens
Direct
Deck
Battens
i_rect
Battens
Direct
Deck
ec
6.19
6.89
6.11
6.80
5.99
6.67
5.85
1 6.61
1 5.66
!0
5.50
1 6.13
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
for Nall -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15132" plywood)
Direct Deck
(min.19/321' plywood)
Battens
Bella "Hi-
2-10d Rin Shank Nails
28.8
41.2
19.4
S° Tile
1'1Od month or Screw
Shank Nail
5.1
618
2.8
2-1 Od Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 #8 Screw
20.7
20.7
18.1
2 #8 Screw
43.2
43.2
29.8
1-1 Od Smooth or Screw
Shank Nail jFleld Clip)
23.1
23.1
19.0
1-1 Od Smooth or Screw
Shank Nail Eave Clip)
29.3
29.3
24.0
2-10d Smooth or Screw
Shank Nails Field Clip)
27.6
27.6
38.6
2-1 Od Smooth or Screw
Shank Nails Eave Clip)
38.1
38.1
41.8
2-10d Ring Shank Nails 33.1 48.1 50.9
1. Installation
with a 4"tile headlap and fastemers are located a min. of 2'W from head of tile:
APPROVED
NOA No.: 11-0414.08
Expiration Date: 07/13/16
Approval Date: 06/02111
Page 4 of 7
so
Table 5: Attachment Resistance Expressed as a Moment Mr (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
I Resistance
Bella "High S" Tile
Adhesive
29.3
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TIIeBond Average weight per patty 10.7 grams,
Polyfoam Product Inc. Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a.Moment - Mt (ft-lbf)
for Single Patty, Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
I Resistance
ells "Hr h S°` ile1121bi`.
a4mIP-0 `e FOM
(66f5
Pol oam Pol ProTM
38.7
3 Large patty placement of 03 rams of Pol ProTM.
4 Medium patty placement of 24 rams of Pol Prow.
Table 7: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
for Mortar Set Systems
Tile
Profile
Tile
A Iication
Attachment
Resistance
Bella "High S" Tile
Mortar Set
24.5
5 Tile -rite Roof Tile Mortar.
NOA No.: 11-0414.09
Expiration Date: 07/13/16
Approval Date: 06/02/11
Page 5 of 7
M
so
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
seen in detail below, or following statement: "Miami -Dade County Product Control
Approved".
OR
g ENTEURR,`
ENTEGRA SALES BELLA "HIGH S" CONCRETE TILE LABEL
(LOCATED UNDERNEATH TILE)
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
NOA No.: 11-0414.08
MIAMI•DADE COUNTY Expiration Date: 07/13/16
Approval Date: 06/02/11
Page 6 of 7
00 00
PROFILE DRAWING
END OF THIS ACCEPTANCE
NOA No.: 11-0414.08
Expiration Date: 07/13/16
Approval Date: 06/02/11
Pagel of
DESIGN LOAD CRITERIA
DB16N L.OAD5 PER THE FLORIDA EXI5TIN16 BUILDIN6 CODE, 2010 EDITION
DE516H CRITERIA PER A5CE'I
ULTIMATE WIND SPEED REGION, V(VIL)._.—._..110
MPH
NOMINAL WIND SPEED REGION, V(asci). _ ._.._.132
MPH
WIND BORNE DEBRIS RE61ON
ENCLOSED STRUCTURE
BUILDING HEI6HT < 40 FTROOF
SCAIVNtL
PITCH FLAT
R15K CATE60RY II
BY
INTERNAL PRE55M GOEFF. t 0.1&
St. Lucie On,
EXP05URE B
HE16HT I EXP05VRE GOEFF. 1.09
END ZONE 15 WITHIN A DISTANCE OF
W = 9 FT FROM BUILDING CORNERS.
FASTENER SCHEDULE PER 10 LINEAR FT
ZONE
DESIGN
PRESSURES
NO. OF
FASTENERS
AL10WA5LE
FASTENER 5P
LAP
WA
WA
WA
WA
MITTING
2
WA
WA
WA
WA
WA °unt-A FL
3
-8b
613
-93
b° O.G.
(2) STAGGERED ROWS 05' O.G.
al
*`�
CALCULATIONS FOR GAF RUBEROID MODIFIED BITUMEN ROOF SYSTEM FOR WOOD DECKS 9
GAFGLAS 075 BASE SHEET ATTACHMENTS AT FLAT ROOF AREAS (NOA No. 14-0811.01 EXPRIES 11/8
CALCULATIONS BASED ON THE ROOFING APPLICATION STANDARD (RAS 117) GENERAL LORTATION /7�
A) MWN # OF FASTENlER5 = UNKN0WN # OF FA5TENER5
MAX. DE516N PRE55M ELEVATED DE516N PRESSURE
B) FASTEN BASE SHEET WITH APPROVED ANNULAR RING SHAM% NAILS AND TIN CAPS
G) KNOWN # OF FA5TENER5 PER 10 LIL FT: 33 (9' OL. 0 THE LAP 8 (2) 5TA66ERED ROWS ® 12' O.G. IN FIELD
MAX DE516H PRE55URE = -45 P5F A5 PER NOA
ZONE 3
USE b8 FASTENERS PER 10 LINEAR FEET
33 = X
45 86
X = 0.1 FASTENERS ALLOWABLE UPLIFT -013 PSF ) REGV -86 P5F
ANCHOR SHEET SHA
LL ALL BE FA5TENED ® b' OL. IN THE LAP A TWO 5TA66ERED ROWS 0 5' O.G.
THES: MIS AND ALL PROPOSa"D WORK
ARE SUBJECT TO ANY COEDS ECTIONS
REQUIRED BY PinD INSPECMRS THAT
MAY BE NECE�tRY IN OfID" TO
COMPLY WITH ALL APPLICABLE CODES.
'ST. LUCIE CATHOLIC CHURCH 1---
imw.
PARRISH HALL - 425 SW IRVING ST.
PORT ST. LUCIE, FLORIDA
"" E`CALCS FOR ROOF ATTACH: FIAT ROOF
.��•�P�� ANTyO'•..
.ti
e.
m
No
O T\
o '1
w
3-27-15
m°
15-134 m
a.
TR cxccrmer: wp
SK-1 « 2
►MIAMI•�
MIAMI-DADS COUNTY
►71 M
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONODIIC RESOURCES (RER)
Miami, Florida 33175-2474.
BOARD AND CODE ADMINISTRATION DIVISION
T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA)
mvw.miamidade.eov/economv
GAF
1361 Alps Road
Wayne, NJ 07470
FILE COPY
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense. of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
%DESCRIPTION GAF Rbe uroid®,Modtfied Brtumert Roof stem for Wood Decks- '
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and.there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has peen a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed„ then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0424.14 and consists of pages 1 through 29.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page I of 29
APPROVED ASSEMBLIES
�Membraae_Type:_____SBS'
Deck_TypeaI: _^.�„Wootl,ansulated�
Deck Description:
19132" or greater plywood or wood plank
,4iitem_Type A(i);_
Anchor sheef mechanically fastened; all-layersof insulation adhered With
?approved asphalt=
All General and System Limitations shall apply.
Fire Barrier:
F1reOnt Fire Barrier Coating, VersaShield" Fire -Resistant Roof Deck Protection
(optional)
or Securoce Gypsum -Fiber Roof Board.
Anchor sheet:
GAFGLAS® 980 Ultima7 Base Sheet, GAFGLAS® Stratavent®Eliminator—
Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Heat -Weld Smooth
or Ruberoid® SBS Heat -Weld"' 25 base sheet mechanically' fastened to deck as
described below.
Fastening
�TjAdiGLAS® Ply=4, GAFGLAS" F1exPly� 6',.GAFGLAS®#75:Base:Sheet oi_any
Options:
of above anchor sheets attached to deck with approved annular ring shank nails
and tin caps at a fastener spacing.of Ti' o c.,atfhe lap staggered and in two "rows
—j12°.o.c.imthefield. --
,*(Maximum Design Pressure,-zO psf See General Limitations#7)
GAFGLAS" Ply 4, GAFGLASs`F1exPly"' 6, GAFGLAS® #75 Base Sheet or any
of above anchor sheets attached to deck with Drill-Tec" #12 Fastener, DHWTec'"
# 14 Fastener or Drill-Tec' XHD Fastener and Drill-Tec'" 3" Steel Plate, Drill -
Tee " AccuTrac Flat Plate or Drill-Tec7 AccuTraco Recessed Plate installed 12"
o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure —45psf. See General Limitation #7)
GAFGLAS® FlexPly" 6, GAFGLAS® #75 Base Sheet or any of above anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —52.5 psf. See General Limitation #7)
GAFGLAS® 480 Ultima" Base Sheet, Rubcroid020, RuberoieMop Smooth base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of V o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressu re —60psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with
Drill-Tec" 912 Fastener, Drill-Tec" #14 Fastener or Drill-Tec' XHD Fastener
and Drill -Tee" 3" Steel Plate, Drill-Tec AccuTraco Flat Plate or Drill-Tec"
AccuTrae Recessed Plate installed IT' o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet
(Maximum Design Pressure —60 psf. See General Limitation #7)
NOA No.: 14-0611.01
FIV
Expiration Date: 11/06/15
�yApproval Dale: e 7 of
Itl� Page 7 6 29
Fastening Any of above anchor sheets attached to deck approved annular ring shank nails
Options: and 3" inverted Drill-Tec"' insulation plates at a fastener spacing of 9" o.c. at the
(Continued) 4" lap staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with
Drill-Tec 412 Fastener, Drill-Tec'" #14 Fastener or Drill-Tecw XHD Fastener
and Drill-Tec" 3" Steel Plate, Drill-Tec AccuTrac Flat Plate or Drill-TecTM
AccuTraco Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure-75 psf. See General Limitation #7)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fts
EnergyGuarC Polyiso Insulation, EnergyGuard m Polyiso RA Insulation,
EnergyGuard7 Polyiso RN Insulation, EnergyGuard IRA Composite Polyiso Insulation
Minimum 1" thick N/A N/A
StructodeV High Density Fiber Board, EnergyGuard'" Perlite Recover Board
Minimum''/2" thick N/A N/A
EnergyGuard"" Perlite Roof Insulation
Minimum '/Vthick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20-401bs./100 ft. Please refer to Roofing Application
Standard RAS 117for insulation attachment: Insulation listed as base layer only shall be used
only:as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavene
Eliminator Perforated Venting Base Sheet laid dry or a layer of EnergyGuard Perlite Roof
Insulation or wood fiber overlay board on all polyisocyanurate applications.
Base Sheets (Optional) Install one ply of GAFGLASe #75 Base Sheet, GAFGLAS #86
Ultima Base Sheet, GAFGLAS® Ply 4, GAFGLAS F1exPly 6, GAFGLAS®
Stratavent® Eliminator Perforated Venting Base Sheet (laid dry), Ruberoida Mop
Smooth, Ruberoid® 20, Ruberoid® SBS Heat -Weld' Smooth or Ruberoid® SBS
Heat -Weir 25 directly over the top layer of insulation. Adhere with any
approved mopping asphalt applied within the EVT range and at a rate of 20-40
IbsJsq. (See General Limitation 04).
( Ply -Sheet:. W (Optional) One or more plies GAFGLAS® Ply 4, GAFGLAS® FlexPly'" 6
`� r;AFGT.AS® #80 I Tltima Base Sheet Ruberoid® Moo Smooth; Ruberoid®20-
arwa:rare ortu--4u.iosjsq._ __- +
Membrane: I, One or more plies of Ruberoid® 20, Ruberoie 30, RuberoieEnergyCap- 30 FR
SBS Membrane, Ruberoid' 30 FR, Ruberoid® Mop Smooth, Ruberoid Mop 170
FR Ruberoid® Mop Granule', RoofMatchT SBS Modified Granular, Ruberoid
Mop Plus, Ruberoid® Mop FR or Ruberoid® Dual FR fully adhered in an approved
asphalt at an application rate of 25 lb./sq. t 15%.
NOA No.: 14-0611.01
1 Expiration Date: 11/06/15
1 FILE
COPY
Approval Date: 11/06/14
WOOD DECK SYSTEM UmTATIONS:
1 A slip sheet is required with GAFGLASO Ply 4 and GAFGLAS® FlexPly ' 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum '/," DensDeck® Roof Board or '/n" Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIlYIITATIONS:
l . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval;guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every IT in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 lbf insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida. Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
r— _ -
! 7INefibfeter -din d comer areas shall comply vcnth the enhanced uplift presswe regmrements.of these
S. areas. Fastener densities shalYbe increased for both'insulationandbase sheet as cm as -calculated 1- --�
=compliance withRoofing'Application Standard RAS 117. Calculations.prepared, signed and -sealed ,
by a Florida registered Professional' Engineer, Registered Architect, or Registered'Roof Consultant,
(When this limitation is specifically referred.within thts _NQA, General Lunitation #9wilinot
_-__be.applicable.)- -- ---u
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers).
(When this limitation is specifically referred within this NOA, General Limitation #7will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule61 G20-3'of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-0611.01
MIAMFOADECOUWrY ^0 Expiration Date: 11/06/15
FILE PY Approval Date: 2911/06114
of29 Page 29 of 29