HomeMy WebLinkAboutINSULATION DETAILS04130/2015 09:10 TEAM PARKS
A.
0
611 SE Palm Beach Road
Stuart, FL 34994
(772) 781-1616 ph
(772) 761-0620 fax
Comments.
ffAR}7727810620 P.0011003
f
SCANNED
BY
" . wcie
To: St Lucie Building Department
Fax number: 772-462-6443
From: Team Parks Inc.
Fax number: 772-781-0620
Date: 4-30-15
Regarding: Permit # 1412-0365
Phone number for follow-up:
Please see attached "Insulation Certificate" for Permit # 1412-0365. Majic Oyster.
Thank you,
04/3012015 09:10 TEAM PARKS O:AIn7727810620 P.0021003
Professional Insulators of South Florida
FTC Insulation Installation Certificate
To: ISt Lucie County Date: JAprII21, 2015
Re: I Lot(Block:
Address: 110M S Ocean Blvd Project: JMsjic0ystcr
The nndemlaned herphv eeranea that insalatinn has been installedin the above described urouerty as follows:
1. Exterior CBS wails have been insulated with:
Spray -on Cellulose
Thickness in inches:
Fiberglass Blankets
Manufacturer:
N Foil
Rock Wool Blankets
Density:
X
Aluminum Foil
R-Value:
R 4.1
Rigid Board
Polystyrene
Other
2. Pitched area of roof deck have been Insulated with:
Spray -on Cellulose
Thickness in inches:
5.5"
Fiberglass Blankets
Manufacturer:
Bayer
Rock Wool Blankets
Density:
Aluminum Foil
R-Value:
R-20
Polyurethane
X
Open Cell SPF
Applied Directly to Open Cell SPF Insulated with:
Spray -on Cellulose
Thickness in inches:
4 mil
Fiberglass Blankets
Manufacturer:
Bayer - Bayseal IC
X
Ignition Barrier
Density:
Fiberglass Blown
R-Value:
Cellulose Loose Fill
Open Cell SPF
3. Perimeter kneewalls have been insulated with:
Fiberglass Blankets
Thickness in Inches:
5.5"
Fiberglass Loose Fill
Manufacturer:
Bayer
Rock Wool
Density:
Fiberglass Blown
R-Value:
R-20
Cellulose Loose Fill
X
Open Cell SPF .
4. Interior flamed walls have been Insulated with:
X
Fiberglass Blankets
been Insulnted with:
I
Rock Wool
Thickness in Inches:
3.4"
Polyurethane
Manufacturer:
lowens Corning
Spray -on Cellulose
Density:
Open Cell SPF
R-Value:
R-11
5. The followine have been insulated:
++.• ,q,•,:
:�;••�owob ®�•:
•r�i�. �t]f18®•` q?+`+,
�•to'. for ',°,+�+
lipf,
Team Parks
General Contract/Builder
CBC1254041
Professional Insulators of South Florida,Inc.
Insulation Contractor
r r/
0413012015 09:10 TEAM PARKS (FA1)772 7810620 P.0031003
Professional Insulators of South Florida
FTC Insulation Installation Certificate
To: ISt Lucie Count Date: A ri121 2015
Re; I Lot/BIOek:
Address: 110999 S Ocean Blvd Project: IMallcoyster
The underxinned herehv . rtinec that Insulation has been Installed in the above described uronerty as follows:
1. Biterlor CBS walls have been insulated with:
Spray -on Cellulose
Thickness In Inches:
Fiberglass Blankets
Manufacturer:
Fi Fall
Rock Wool Blankets
Density:
X
Aluminum Foil
R-Value:
R 4.1
Rigid Board
Polystyrene
Other
2. Pitched area of roof deck have been Insulated with:
Spray -on Cellulose
Thickness in inches:
5.51,
Fiberglass Blankets
Manufacturer:
Bayer
Rock Wool Blankets
Density:
Aluminum Foil
R-Value:
R-20
Polyurethane
X
Open Cell SPF
Directly to Open Cell SPF Insulated with:
Spray -on Cellulose
—Applied
Thickness in inches.
4 mil
Fiberglass Blankets
Manufacturer:
Bayer- Bayseal IC
X
Ignition Barrier
Density:
Fiberglass Blown
R-Value:
Cellulose Loose Fill
!Open Cell SPF
3. Perimeter kneewalls have been Insulated with:
Fiberglass Blankets
Thickness In Inches:
5.5"
Fiberglass Loose Fill
Manufacturer:
Bayer
Rock Wool
Density:
Fiberglass Blown
R-Value:
R-20
Cellulose Loose Fill
X
Open Cell SPF
4. Interior framed walls have been insulated with:
X
Fiberglass Blankets
been Insulated with:
I
Rock Wool
Thickness In inches:
13.511
Polyurethane
Manufacturer:
10wens Corning
Spray -on Cellulose
Density:
Open Cell SPF
R-Value:
R-11
S. The following have been Insulated:
�c.sw4tp
°v�,a004%'t••4
gym• .git,
•.�',•® f��p �y.,
••®@e I"�`'vs+,
Team Parks
General Contract(Builder
CBC1254041Competency
4
Professional Insulators of South Florida, Inc.
Insulation Contractor
i