Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL'Florida Building Code Online Page 1 of 3 ,6 r es I ui ion FA0d8�Eja"Tel iC'� BCIS Nome j top In ;User Regis[ratlpn Hot Topics I Submit SurNarpe , Stats&Facts Publications I FBC Staff i BCIS SRe Map 1 un i ,earcn Business, Professi al �SEa vucro Approval ®Regulation �� COPY , Protlu I Aoomval Menu > Product ar Aooliration Seamh > Aoollrati,. Ui > Applimtlon petal _ FL # FL7347-R4 Application Type Revision Code Version 2010 Application Status Approved Comments Archived ❑ e A CANNED Product Manufacturer � Therma-Tru Corporation SCANNED Address/Phone/Emall 118 Industrial Drive BY Edgerton, OH 43517 St. Lucie (419) 298-1740 Count rickw@mbldgconsultants.com _ Authorized Signature Rick Wright rickw@rwbldgconsuitants.com Technical Representative - - Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By r Sections from the Code Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a licensed Florida Professional Engineer ® Evaluation Report - Hardcopy Received Lyndon F. Schmidt, P.E. PE-43409 National Accreditation and Management Institute 12/31/2018 Ryan J. King, P.E. 0 Validation Checklist - Hardcopy, Received FL7347 R4 COI CERTIFICATE of INDEPENDENCE.ndf Standard year ANSI/AAMA/NWWDA 301/I.S.2/A440 2005 ASTM E1886 2002 ASTM E1996 2002 TAS 201, 202, 203 1994 http://Www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtg02Sx4jpd6 W... 6/5/2015 Florida Building Code Online Page 2 of 3 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Method 1 Option D 06/18/2012 06/21/2012 06/27/2012 08/07/2012 01/31/2015 FL 7t Model, Number or Name Description 7347.1 a. °Fi6erClassc" "SmobthStar", 3'0 x 6-8 "Impact" Glazed Fiberglass Single Door (X) - '6lassidraft"o."@IassicCraft or Outswing Rustic" inswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL7347 R4 it INST 7347.1.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7347.1 for Design Pressure Ratings by FL7347 R4 AE EVAL 7347.1.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and Installation Instructions. 7347.2 b. "FiberClassic", "SmoothStar", 3'0 x 6'8 "Impact" Glazed Fiberglass Single Door with "ClassicCraft" or "ClassicCraft Sidelite (OX or XO) - Inswing or Outswing Rustic" Limits of Use Installation Instructions Approved for use in HVHZ: No FL7347 R4 II INST 7347.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7347.2 for Design Pressure Ratings by FL7347 R4 AE EVAL 7347.2.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and Installation Instructions. 7347.3 c. "FiberClassic", "SmoothStar", 3'0 x 6'8 "Impact" Glazed Fiberglass Single Door with "ClassicCraft" or "ClassicCraft Sidelites (OXO) - Inswing or Outswing Rustic' Limits of Use Installation Instructions Approved for use in HVHZ: No FL7347 R4 II INST 7347.3.ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7347.3 for Design Pressure Ratings by FL7347 R4 AE EVAL 7347.3.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation Instructions. 7347.4 d. "FiberClassle, "SmoothStar", 6'0 x V8 "Impact" Glazed Fiberglass Double Door (XX) - "ClassicCraft" or "ClassicCraft Inswing or Outswing Rustic" Limits of Use Installation Instructions Approved for use in HVHZ: No FL7347 R4 II INST 7347.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7347.4 for Design Pressure Ratings by FL7347 R4 AE EVAL 7347.4.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and Installation Instructions. 7347.5 e. "FiberClassic", "SmoothStar", 6'0 x 6'8 "Impact" Glazed Fiberglass Double Door with "ClassicCraft" or "ClassicCraft Sidelites (OXXO) - Inswing or Outswing Rustic" Limits of Use Installation Instructions Approved for use in HVHZ: No FL7347 R4 li INST 7347.5.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7347.5 for Design Pressure Ratings by FL7347 R4 AE EVAL 7347.5 odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and Installation instructions. ead Next http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwd)gtg02Sx4jpd6 W... 6/5/2015 14— 7-S`J R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico. FL 33595 Phone 913.659.9197 Florida Board of Professoriat Engineers Cemfinate of Authorization No. 9813 RFcovFo ✓UNl sA Product Category Sub Category — Manufacturer Product Name Swinging Theme Tru Corporation 'Smooth Star", "Fiber Classic" Exterior Exterior Door 118 Industrial Drive "Classic Croft" 8 "Classic Craft Rustle' Doom Assemblies Edgerton, OH 43517 Glazed Fiberglass Door Phone 419.298.1740 InswIng IOutswin "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on Rule Chapter No. 9N-3, Method 1 D of the State of Florida Product Approval, Department of Business 8 Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 2010 Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas outside of the "HVHZ" requiring wind home debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.4 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-7347.1 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-7347.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 06-0718.1 ANSVAAMA(NW WDA 101/I.S.2/A440-05 Architectural Testing, Inc. Michael D. Stremmel, P.E. ASTM E1996/1886-02 2. Miami Dade NOA Materials Testing 08-0206.01 Saflex HP Glass Interlayer 3. Drawing No. Prepared by Signed & Sealed by No. FL-7347.1 RW Building Consultants, Inc. (CA #9813) Lyndon F. Schmidt, P.E. 4. Calculations Prepared by Signed & Sealed by Anchoring RW Building Consultants, Inc. (CA #9813) Lyndon F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Thenna Tru Corporation is manufacturing products within a quality assurance program that complies with ISOAEC 17020 and Guide 53. Lyndon F. Schmidt, P.E. FL PE No. 43409 6121/2012 PF 986 Sheet 1 of 1 61 66 EXTERIOR 21,=MAX. 3 .I D.L.O. All 1 � Es ll la i INTERIOR , d 0 1QHORIZOMAL CROSS SECTON F"J 'd A S a:C .� O e �°yypgi / IIT CELLULAR GLASS g� /// GLAZING 1 GLASS 3C1 TAPED d 1 /B"TEMPERED EXTERIOR GLASS fi S,a '�"? AIRSPACE419 , ° 'R¢R WTANNEALED EXTERIOR INTERIOR &s � 12 Dana "' Llafllc LYNt Rutik 090'(BY LU INIERIAYER INTERIOR ler SOLUTIA) GI Dow 995 Y I/WANNEALED OR 4 GLASS IAA SIKA 554 SPACER GLAZING L a SPACER 4 z 0 /.11' NI E0 I r-1.16'+� L I N ij�K{tC n r.r.._IJ ti' O z T u 'NINGESIDESRE COREMALERIAL•LVLORISI ALTERNATE CORE MATERIAL: PONDEROSA, Bk AL 'm RADWA. PUTAL EILOTIR, TAEOA OR SUGAR M O DDGR l 0 tAlt /� may. PINE, LFS EADAR OR REDEDWOOD.OR ��•CEDAR, INCBaSE � , VERTICAL CROSS SECZION OAA9O 1q' a FL-7J47.1 c s .4 o 9 o 6 d INTERIOR 17 • 41 50 60 G < 27 �� { 60 r•2yCq 21 a ��e�4$ X I • G4 LS g plF G 5 S at 11 d 7 17 S DMIOR R .•.n o: 20 C A L d d E t-tit•Mw. R Erne. Qrp.J ' 0 NORQOMAL CROSS SECTION INTERIOR 17 • d Slwvm wIIXM bllk 27 • INTERIOR 4D f2O i TERIOR 7 EMERIOR! 0 v 0 L i � u L 20 MM 1 17 0H Q N.rN.T.S.E 1-UfnvN. C oc en A< m Eine.ln'p.l E auc ar. lF5 # 10 NORROMAL CROSS SECTON d k /\ t-t/1'Inw. \NORIZOMAL CROSS SEC71ON u�n.ow � d kuMrg confgwtian MB-Iryp,l FL_7347.1 0 n 0 BILL OF MATERIALS ITEM DESCRIPTION MATERIAL ITEMI DESCRIPITON MATERIAL A 1%BUCKSG>-0.55 WOOD 40 FIBERGLASS DOOR PANEL -SMOOTH STAR - i�! ,J! B 2X BUCK SG>=0.55 WOOD 41 FIBERGLASS SMC SKIN MIN D.065"THICKNESS SMC z& -�s A. gR n C MAX. I/4'SHIM SPACE WOOD 42 TOP RAIL COMPOSITE LT D 1/4'X23/4' PFH ELCO OR ITW CONCRETE SCREW STEEL 43 LATCH STILE LVL WOOD E MASONRY - 3,192 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE M HINGE STILE SG x 0.42 WOOD 53^pp 1 45 BOTTOM RAIL WOOD F 1/4' X T3/4' PFH RW CONCRETE SCREW STEEL 46 POLYURETHANE FOAM CORE- BASF 1.9 LOS. DENSITY FOAM G 3/16'X 3-1/4'PFH TIW CONCRETE SCREW STEEL 47 LOCK BLOCK REINFORCEMENT WOODH 1/4'x 3-1/4'PFH IIW CONCRETE SCREW STEEL 50 FIBERGLASS DOOR PANEL -FIBER CLASSIC 5'8n I i 1/4'X2-1/4'PFHIIWCONCRETESCREW STEEL 51 FIBERGLASS SMC SKIN MIN 0.06.7 THICKNESS SMC e 3 J 1/4'X3-3/4'PFHTIWCONCRETESCREW STEEL 52 TOP RAIL COMPOSITE d K 88 X 2-1/2' PFH WOOD SCREW STEEL 53 LATCH STILE LVL WOOD L 010 X2-I rr PFH WOOD SCREW STEEL 54 HINGE STILESG> 0.42 WOOD I EXTERIOR LIFE FRAME (6063461 ALUMINUM 55 BOTTOM RAIL COMPOSITE 2 INTERIOR LJIE FRAME 16063-T61 ALUMINUM 56 POLYURETHANE FOAM CORE- BASF 1.91BS. DENSITY FOAM rc 3 LITEFRAMETRIM PVC 57 LOCK BLOCK REINFORCEMENT WOOD § +f 4 #10 X WIT PFH SCREW STEEL 60 FIBERGLASS DOOR PANEL- CLASSIC CRAFT 6 CLASSIC CRAFT RUSTIC �Ki 7 MEDIUM RFACH COMPRESSION WEATHER-STRIP ERMA-TRU FOAM 61 FIBERGLASS SMC SKIN MIN 0A90' THICKNESS - SMC 15 8 LONG REACH COMPRESSION WEATHERSTRIP ERMA-TRU FOAM 62 TOP RAIL COMPOSITE"o 9 4'%4'HINGE.097'1HK. ERMA-TRU STEEL 63 LATCH STILE LVL WOODm a �� 10 RTOX3/4'PFH WOOD SCREW HINGE TO FRAME STEEL 6/ MNGESTIIESG r-0.42 WOOD 17 PASSAGE LOCK- KWIKSET SIGNATURE SERIES STEEL 65 BOTTOM RAIL COMPOSITE 18 THRESHOLD OUTSWING ERMA-TRU ALUMJWOOD 66 POLYUREHANE FOAM CO RE- BASF I.9 LBS. DENSITY FOAM =I o 19 HEADER JAMB 4.656"%1.25'THERMA-TRU, PINE SG>=0.42 20 SIDE JAMB 4.656'X 125-THERMA-TRU SG>=0.42 21 DEADBOLT- KWIXSET SIGNATURE SERIES (7801 27 LATCH STRIKE TPLATE 28 DSWING T THRESHOLD 32 DOOR BOTTOM SWEEP 33 INSWING THRESHOLD SAT `:.T;-:vr.: ,;�.f\.s5:r.\'',,"a•:- 3S ihxMla WOOD WOOD STEEL STEEL STEEM.0 PVC ALUM.COMP. �4563'--{ I6 iM1evaM ` --{ lA7 F-- �-I 1T31�8' r'-0.554' 7� r— 4.563' �I I ._��L o 2.35571 23 19 20 JmM & m 0 nre 4117108 N.T.S. AL oa m: LFS ow�o in: FL-7347.1 am 9 n 9