HomeMy WebLinkAboutPLANS 2THIS IS A LETTER OF CERTIFICATION FOR STEEL BUILDING SYSTEMS, INC.'S PROJECT #14-12-272 FOR LIBERTY BAPTIST CHURCH, TO BE LOCATED IN FT. PIERCE, FL. THIS LETTER CERTIFIES THAT STEEL BUILDING SYSTEMS, INC.'S BUILDING(S) MEETS THE INFORMATION IN THE DESIGN CRITERIA. THIS LETTER OF CERTIFICATION IS WRITTEN SPECIFICALLY FOR THE BUILDING(S) PROVIDED BY STEEL BUILDING SYSTEMS, INC. THIS LETTER DOES NOT IMPLY NOR CONSTITUTE AN AGREEMENT THAT THE MANUFACTURER OR THE MANUFACTURER'S ENGINEER IS ACTING AS THE ENGINEER OF RECORD OR DESIGN PROFESSIONAL FOR THE CONSTRUCTION PROJECT. WIDTH (ft LENGTH ft) EAVE HEI HT (ft) ROOF SLOPE Rise/12) BUILDING CODE DEAD LOAD psf) COLLATERAL OAD (psf) ROOF LIVE LOAD psf) LIVE LOAD REDUCTION DESIGN CRITERIA = 90.0 = 24.8333 = 16.0/ 16.0 = 4.0 = FBC 10 = 2.0 = 0.0 = 20.0 = YES GROUND SNOW LOAD ( sf) = 0.0 ROOF SNOW LOAD (ps{ = 0.0 THERMAL COEFFICIENT Ct) = 1.0 IMPORTANCE - SNOW = 1.0 SNOW EXPOSURE (Ce) = 1.0 WIND SPEED (mph) = 161.0 RISK CATEGORY = II - NORMAL WIND EXPOSURE = B CLOSED/OPEN/PARTIAL = C INTERNAL GCpi = +0.18/-0.18 SEISMIC USE GROUP (SUG) SEISMIC SITE CLASS = D SEISMIC COEFFICIENT = 0.09 MAPPED RESPONSE (Ss = 0.0550 MAPPED RESPONSE S1 = 0.0290 DESIGN CATEGORY (SDC = A IMPORTANCE - SEISMIC = 1.00 SITE COEFFICIENT (Fa) = 1.6000 SITE COEFFICIENT (FV) = 2.4000 DESIGN RESPONSE 0.0880 DESIGN RESPONSE= 0.0696 JSms1= DESIGN RESPONSE Sds) = 0.0587 DESIGN RESPONSE Shc = 0.0464 RES MOD FACTOR (Mom R = 3.0 APP PERIOD (MOMENT) To = 0.2573 RES MOD FACTOR (Brc R = 3.0 APP PERIOD (Braced) a = 0.1600 TRANVERSE SYSTEM = MOMENT FRAMES LONGITUDINAL SYSTEM = BRACED FRAMES NOTE: THE SEISMIC ANALYSIS PROCEDURE USED ON THIS STRUCTURE IS THE EQUIVALENT LATERAL FORCE PRO- CEDURE. STRUCTURAL STEEL ASTM# (Plate) = A529; A570; A572 PLATE YIELD (Fy) = 50.0 ksi COMPONENTS AND CLADDING COMP/CLAD PRES SUCT ROOF SUCT ASTM# (Bar) = A-529; A-570; A-572 LOCATION (PSF) (PSF) (PSF) COLUMN 37.5 -41.1 PLATE YIELD (Fy) = 50.0 ksi LIGHT GUAGE STEEL GIRT/HEADER 37.5 -41.1 ASTM# (Cold -Form) = Al008; Al011 JAMB 37.5 -41.1 COLD -FORM YIELD (Fy) = 55.0 ksi WALL PANEL 46.6 -62.3 ASTM# (Panel) = A792 PANEL YIELD (Fy) = 80.0 ksi PURLIN 19.0 -38.7 ROOF PANEL 26.8 -42.6 NOTE: ALL CONNECTION BOLTS ARE DESIGNATED LONG. BRACING 15.8 -11.5 -27.2 IN THESE DRAWINGS AS EITHER A "M" FOR A307 BOLTS OR A "H" FOR A325 LONG. BRACING 24.1 -17.0 BOLTS. (EDGE ZONE) NOTES TO ERECTOR/OWNER: [1] "SBS" IS NOT'RESPONSIBLE FOR THE ERECTION OF THE BUILDING, THE SUPPLY OF ANY TOOLS OR EQUIPMENT, OR ANY OTHER FIELD WORK UNLESS "SRS" HAS BEEN CONTRACTED FOR THESE. "SBS" DOES NOT PROVIDE ANY FIELD SUPERVISION FOR THE ERECTION OF THE BUILDING, .NOR DOES "SBS" PERFORM ANY INSPECTIONS DURING OR AFTER ERECTION. [2] USE ONLY THE ERECTION DRAWINGS PROVIDED BY "SBS" AND IN- CLUDED IN THE ERECTOR'S PACKAGE DELIVERED BY THE TRUCK DRIVER WITH THE_ BUILDING. "SBS" IS NOT LIABLE FOR ANY CLAIM RESULTING FROM THE USE OF OTHER DRAWINGS. [3] CHECK SLAB AND ANCHOR BOLT PLACEMENTS BEFORE STANDING ANY FRAMING. IF THE SLAB IS NOT SIZED CORRECTLY OR IS OUT OF SQUARE, OR IF THE ANCHOR BOLTS ARE NOT CORRECTLY LOCATED, CALL "SBS". "SBS" IS NOT LIABLE FOR LABOR CHARGES RESULTING FROM STAND"n COALAI"In nAl Ahl IAIr`r%DDCr`T ci AD [4] BEGIN ERECT FIRST AND T ATTACHMENT A SNUG COt INSTALLING F THE CABLE I WITH REMAIN BAYS ARE El [5) THE CORREC DRAW THE C CHIPPING AN AGES OF MA SHOP DRAWING I SUBMITTAL REVIEW STATUS DESIGN PROFESSIONAL DETERMINATION RESPONSE REQUIRED No Exceptions Taken Ll` Rejected ❑ Confirm ❑ Noto Markings ❑ Comments Attached ❑ Revibmit ❑ Doiga Prolessimnars rovis:v is uny for checking con!ormnnce with the infom> Son given and with the design concept expressed In the Contract Documents. All markings an•7lor eommenls applied by the Design Pm!essional shall net rereue the Contractor from campbnce vvAli the Cunirci Documents not Vmv detwwdures mere from. The Conhaclot remains responsible for detaits and axuta y conrnming and correialky an puanf;!' s and dinrensions; selecting rahrication pfccesses: trchn4ues of assembly; perintming the work In a sale manner and coordinating the work with alt other trades. THE SPAFFER GROUP. INN. ENGINEERS/CONSULTANTS FdShaffer PE 05/27/15 By: Date: SUBJECT TO __ .,..� ,.,....... '"'. ..__. .., IFICAT16N TO THE.:6UI.LDING. "SBS" DOES NOT PAY CLAIMS FOR ER- ROR CORRECTION l)NLESS APPROVED IN WRITING BY "SBS" BEFOREHAND. STATUS OF THESE DRAWINGS FOR OWNER'S USE - NOT FOR CONSTRUCTION. FOR APPROVAL - NOT I FOR. CONSTRUCTION. FOR PERMITTING - NOT FOR CONSTRUCTION. FINAL DRAWINGS - FOR CONSTRUCTION. ERECTION DRAWINGS - FOR CONSTRUCTION. ❑ ANCHOR BOLT PLANS,FOR CONSTRUCTION. SCANNED BY St. Lucie Count% Gregory S. ,12149 Nell Purvis Road-i ,Adel, GA 31620 I. PIE 'sr 54419 STRUCTURAL STAMP REVISIONS 2/02/2015 2/11/2015 5/07/2015 5/21/2015 = J U LIL elf p Q co U C)R M W >- ILL a � w LL p U m W O jL coo Ir- W M LL U m O J J 0 0 Li E Z 0 m Co N m a v �Fnn' o mN YI o`Oco 1fl 1!� rL J ¢ co WAIN v��m ZZ J� ® UJ ,:N: Q N J xLL J Z Woe ® fA N o n m M m 0 M N �Qp x a a Ain 14-12-272 12 22 2014 MSS I 'NONE COVER PAGE ER: PAG E 0 REVISIONS THIS IS A LETTER OF CERTIFICATION FOR STEEL BUILDING SYSTEMS, INC.'S PROJECT #14-12-272 FOR LIBERTY BAPTIST CHURCH, TO BE LOCATED IN FT. PIERCE, FL. THIS LETTER CERTIFIES THAT STEEL BUILDING SYSTEMS, INC.'S BUILDING(S) MEETS THE INFORMATION IN THE DESIGN CRITERIA. THIS LETTER OF CERTIFICATION IS WRITTEN SPECIFICALLY FOR THE BUILDINGS) PROVIDED BY STEEL BUILDING SYSTEMS, INC. THIS LETTER DOES NOT IMPLY NOR CONSTITUTE AN AGREEMENT THAT THE MANUFACTURER OR THE MANUFACTURER'S ENGINEER IS ACTING AS THE ENGINEER OF RECORD OR DESIGN PROFESSIONAL FOR THE CONSTRUCTION PROJECT. DESIGN CRITERIA WIDTH (ft) = 90.0 LENGTH (ft) = 24.8333 EAVE HEIGHT (ft) = 16.0/16.0 ROOF SLOPE Rise/12) = 4.0 BUILDING CODE = FBC 10 DEAD LOAD psf) = 2.0 COLLATERAL CAD (psf) = 0.0 ROOF,.LIVE LOAD (psf) = 20.0 LIVE LOAD REDUCTION = YES GROUND SNOW LOAD ( sf) = 00 ROOF SNOW LOAD (psf = EO THERMAL COEFFICIENT Ct) = 1.0 IMPORTANCE - SNOW = 1.0 SNOW EXPOSURE (Ce) = 1.0 WIND SPEED (mph) = 161.0 RISK CATEGORY = II - NORMAL WIND EXPOSURE = B CLOSED/OPEN/PARTIAL = C INTERNAL GCpi = +0.18/-0.18 SEISMIC USE GROUP (SUG) SEISMIC SITE CLASS = D SEISMIC COEFFICIENT = 0.09 MAPPED RESPONSE (Ss) = 0.0550 MAPPED RESPONSE (S1)) = 0.0290 DESIGN CATEGORY (SDC = A IMPORTANCE - SEISMIC = 1.00 SITE COEFFICIENT (Fa) = 1.6000 SITE COEFFICIENT (FV) = 2.4000 DESIGN RESPONSE = 0.0880 DESIGN RESPONSE Sm1 = 0.0696 ISms) DESIGN RESPONSE Sds) = 0.0587 DESIGN RESPONSE Sd1] = 0.0464 RES MOD FACTOR (Mom) R = 3.0 APP PERIOD (MOMENT) To = 0.2573 RES MOD FACTOR (Brc) R = 3.0 APP PERIOD (Braced) To = 0.1600 TRANVERSE SYSTEM = MOMENT FRAMES LONGITUDINAL SYSTEM = BRACED FRAMES NOTE: THE SEISMIC ANALYSIS PROCEDURE USED ON THIS STRUCTURE IS THE EQUIVALENT LATERAL FORCE PRO- CEDURE. STRUCTURAL STEEL ASTM# (Plate) = A529; A570; A572 PLATE YIELD (Fy) = 50.0 ksi COMPONENTS AND CLADDING COMP/CLAD PRIES SUCT ROOF SUCT ASTM# (Bar) = A-529; A-570; A-572 LOCATION (PSF) (PSF) (PSF) COLUMN 37.5 -41.1 PLATE YIELD (Fy) = 50.0 ksi LIGHT GUAGE STEEL GIRT/HEADER 37.5 -41.1 ASTM# (Cold -Form) = A1008; A1011 JAMB 37.5 -41.1 COLD -FORM YIELD (Fy) = 55.0 ksi ASTM# (Panel) = A792 WALL PANEL 46.6 -62.3 PANEL YIELD (Fy) = 80.0 ksi PURLIN 19.0 -38.7 ROOF PANEL 26.8 -42.6 NOTE: ALL CONNECTION BOLTS ARE DESIGNATED LONG. BRACING 15.8 -11.5 -27.2 IN THESE DRAWINGS AS EITHER A "M' FOR A307 BOLTS OR A "H" FOR A325 LONG. BRACING 24.1 -17.0 BOLTS. (EDGE ZONE) NOTES TO ERECTOR/OWNER: [1] "SBS" IS NOT RESPONSIBLE FOR THE ERECTION OF THE BUILDING, THE SUPPLY OF ANY TOOLS OR EQUIPMENT, OR ANY OTHER FIELD WORK UNLESS "SBS" HAS BEEN CONTRACTED FOR THESE. "SBS" DOES NOT PROVIDE ANY FIELD SUPERVISION FOR THE ERECTION OF THE BUILDING, NOR DOES "SBS" PERFORM ANY INSPECTIONS DURING OR AFTER ERECTION. [2] USE ONLY THE ERECTION DRAWINGS PROVIDED BY "SBS" AND IN- CLUDED IN THE ERECTOR'S PACKAGE DELIVERED BY THE TRUCK DRIVER WITH THE BUILDING. "SBS" IS NOT LIABLE FOR ANY CLAIM RESULTING FROM THE USE OF OTHER DRAWINGS. [3] CHECK SLAB AND ANCHOR BOLT PLACEMENTS BEFORE STANDING ANY FRAMING. IF THE SLAB IS NOT SIZED CORRECTLY OR IS OUT OF SQUARE, OR IF THE ANCHOR BOLTS ARE NOT CORRECTLY LOCATED, CALL "SBS". "SBS" IS NOT LIABLE FOR LABOR CHARGES RESULTING FROM STANDING FRAMING ON AN INCORRECT SLAB. [4] BEGIN ERECTION WITH A BRACED BAY. INSTALL THE EAVE STRUTS FIRST AND THEN THE PURLINS WHICH FALL AT THE CABLE ATTACHMENT POINTS. NEXT, INSTALL ROOF AND WALL CABLES TO A SNUG CONDITION, SO THAT THE FRAMING IS BRACED. FINISH INSTALLING PURLINS AND GIRTS IN THE BRACED BAY. USING THE ' THE CABLE BRACING, SQUARE AND PLUMB THE FRAMING. CONTINUE WITH REMAINING BAYS, INSTALLING BRACING AS ADDITIONAL BRACED BAYS ARE ERECTED. [5] THE CORRECTION OF MINOR MISFITS BY THE USE OF DRIFT PINS TO DRAW THE COMPONENTS INTO LINE, MODERATE AMOUNTS OF REAMING, CHIPPING AND CUTTING, AND THE REPLACEMENT OF MINOR SHORT- AGES OF MATERIAL ARE A NORMAL PART OF ERECTION AND ARE NOT SUBJECT TO CLAIM. CONTACT "SBS" BEFORE MAKING ANY FIELD MOD- IFICATION TO THE BUILDING. "SBS" DOES NOT PAY CLAIMS FOR ER- ROR CORRECTION UNLESS APPROVED IN WRITING BY "SBS" BEFOREHAND STATUS OF THESE DRAWINGS FOR OWNER'S USE - NOT FOR CONSTRUCTION. FOR APPROVAL - NOT FOR CONSTRUCTION. FOR PERMITTING - NOT FOR CONSTRUCTION. FINAL DRAWINGS - FOR CONSTRUCTION. ERECTION DRAWINGS - FOR CONSTRUCTION. ElANCHOR BOLT PLANS - FOR CONSTRUCTION. L" 02/02/2015 [21 02/ 11 /2015 L31 05/07/2015 [41 05/21 /2015 = J U u_ co LU = 0 v U U w CO W U) >- LL n. a. w LL p U m w O H ( n 1- orf co W coLL U m 0 J w 0 LL LEEOr ; , 4lutil f= Day m Gregory S. Barfield, P.E. t 2149 Nell Purvis Road ,Adel, GA 31620 e ILP.E. # 54419: STRUCTURAL STAMP 0 0 LL Li Z o m crn C N 22N W X mo TN ,, nn 0 M M UI a "' N co Z g°LouN" a U X J wwu¢ ] w Q , mU) N o J M CD W00 W rn N 11"' N A 12 22 2014 MSS I' NONE COVER PAGE WMEM : PAGE 0 1 25,-0„ 2 — — — — — — — — — — — i 1 0 \ Z_ \ 0 J \ m \ m z \ \ X \ IJ I L------------- PROJECT LAYOUT PLAN NOTE: THE PURPOSE OF THE PROJECT LAYOUT PLAN IS TO SHOW THE RELATIONSHIP AND ORIENTATION OF THE VARIOUS BUILDINGS WHICH MAKE UP THE PROJECT. THE PROJECT LAYOUT PLAN IS NOT TO 6E USED TO LAYOUT, FORM UP, OR POUR, THE FOUNDATIONS AND/OR SLABS. e S STEEL Ira S�-JSTFMS INM IN REVISIONS I- 14-12-272 1 12/22/14 Gregory S. Barfield, P.E. f 2149 Neil Purvis Road Adel, GA 31620 L�I'.E. # 54419 STRUCTURAL STAMP UT PLAN MSS . OUT -TO -OUT OF CONCRETE 6" 24,-6" 4" 1�� 24'-4" A I I I I a I a CD z ( a z 1 U) X Lv I I I I I I I I I L--------- 0 ANCHOR BOLT PLAN NOTE: ALL BASE PLATES ® 100'-0" (UNLESS NOTED) iF NOTE SLOPE DOWN AREA IN FRONT OF ROLLUP DOOR 1' TO ALLOW WATER TO DRAIN FROM BASE OF DOOR. n BS STm. BLLMNG SLJSTEMS INC. DBIDHER: LIBERTY BAPTIST CHURCH REVISIONS _'-14-12-272 W 12 22 14 �7102/11/15DDFORT PIERCE, FL 121 DRAWNU NUIE: Sate 05/07/15 ANCHOR BOLT LAYOUT NONE Ls] DmmNG No: DRAWN BY: CHECKED Br. 05/21/15 PAGE 1.1 AASS NFF O DIA= 5/8' N DIA= 3/4' ® DIA= 1' X DIA= 1 1/4' Gregory S. Barfield, P.E. E2149 Nell Purvis Road -Adel, GA 31620 L P.E. # 54419 STRUCTURAL STAMP FRAME LINES: 1 Q Q Q OLUMN LINE H H H 'IV IV IV RIGID FRAME: MAXIMUM REACTIONS, ANCHOR BOLTS, & BASE PLATES COLUMN REACTIONS ) - FRM COL LOAD HMAX V Sk LOAD HM N V ANC BOLT BASE -PLATE (IN) ELEV. UNE UNE ID H VMAX ID H VMIN QTY DIA WIDTH LENGTH THICK (m) 1 G 6 1.9 20.9 7 -3.6 -4.8 4 1.000 8.00 8.375 1.000 0.0 2 -0.1 67.2 1 A 8 3.6 -6.3 5 -1.9 2.7 4 1.250 B.DDO 9.250 1.000 0.0 1 -1.5 4.7 8 3.3 -6.1 1 D 8 0.0 -6.2 8 0.0 -6.2 4 0.750 8.000 12.00 0.500 0.0 1 0.0 8.5 DTES FOR REACTIONS 1. ALL LOADING CONDITIONS ARE EXAMINED AND ONLY MAXIMUM/MINIMUM H OR V AND THE CORRESPONDING H OR V ARE REPORTED. 2. POSITIVE REACTIONS ARE AS SHOWN IN THE SKETCH. FOUNDATION LOADS ARE IN OPROSITE DIRECTIONS. 3. BRACING REACTIONS ARE IN THE PLANE OF THE BRACE WITH THE H POINTING AWAY FROM THE BRACED RAY. THE VERTICAL REACTION IS DOWNWARD. 4. BUILDING REACTIONS ARE BASED ON THE FOLLOWING BUILDING DATA: WIDTH (ft ) - 90.0 EAVEG HEI RT (ft1 - 160 016.0 D� LOADE(,sf) E/12) - 4.0/ COLLATERAL YOAO (Psf) 220.0 ROOF LIVE LOAD ps = 20.0 FRAME LIVE LOAD psi = 12.0 WIND SPEED (mph) = 161.0 EYPOS RE B C 10 (IBC 12) CLOSED/OPEN/PARTLLL = C IMPORTANCE WIND m 1.00 SETS C ZONRTANCE SEISMIC - 1A.00 SEISMIC COEFF (Fa -Ss) = 0.09 5. LOADING CONDITIONS ARE 1 2 3 4 5 6 7 B 90 11 12 13 14 1s 16 RIGID FRAME: BASIC COLUMN REACTIONS (k ) FRAME COLUMN ----- Dead -------- Live ---- ----Floor ------ Wind_Leftl- -Wind-Rights- --Wnd_Lefl2- LINE LINE HORIZ VE1Lr HORIZ VERT HORIZ VERT HORIZ VERT HORIZ VERT HORIZ VERT 1 G 0.4 3.9 1.4 3.7 0.4 21.1 -6.4 -11.9 -0.4 -8.8 -5.8 -6.5 1 A -0.4 1.3 -1.4 3.7 -0.4 0.3 0.4 -8.8 6.4 -11.9 -0.2 -3.4 1 D 0.0 2.2 0.0 6.3 0.0 -0.2 0.0 -12.6 0.0 -12.6 0.0 -7.3 FRAME COLUMN-Wind_Rigght2- UNE HORIZ VERr --Wmd_Longg1---Wind_Lang2- HORIZ -Seismic-Left Seismie_Rigght -Solsmie_Long LINE -3.4 HORR -0.2 VERT -126.1 -2.6 VERT -123.8 HORIZ -0.2 VERT 0.0 HORIZ 0.2 VERT 0.0 HORIZ 0.0 VERT -1.3 1 A 5.8 -6.5 2.6 -123.8 0.2 -126.1 -0.2 0.1 0.2 -0.1 0.0 -1.2 1 D 0.0 -7.3 0.0 -10.8 0.0 -10.8 0.0 -0.1 0.0 0.1 0.0 0.0 FRAME COLUMN F1PAT_1L1- FIPAT_LL-2- UNE UNE HORIZ VERT HORIZ VERT 1 G 0.7 3.5 0.7 0.2 1 A -0.7 0.2 -0.7 3.5 1 D 0.0 3.1 0.0 3.1 ENDWALL COLUMN: BASIC COLUMN REACTIONS (k ) Floor WIND WIND WIND WIND WIND WIND WIND WIND Seis FRM UNE COL UNE DEAD VERT LIVE VERT LIVE VERT Leftl VERY Rigghtl VLRT Left2 VERT Rigght2 VERT Press Sual Long1 Langg2 Left 2 A 0.2 1.5 0.0 -2.8 -2.5 -2.7 -2.4 HORZ -2.2 HORZ 2:4 VERT -2.4 VERY -2.0 VERT 0.0 2 B 0.7 4.2 0.0 -9.4 -6.7 -9.4 -6.7 -5.3 5.9 -9.3 -5.7 0.0 2 C 0.8 3.7 0.0 -8.2 -5.8 -8.2 -5.8 -6.9 7.5 -8.5 -4.8 0.0 2 D 1.0 3.8 0.0 -2.7 -2.7 -3.0 -3.0 -8.3 9.1 -3.9 -3.9 0.0 2 E 2.0 3.7 12.1 -5.8 -8.2 -5.8 -8.2 -6.9 7.5 -4.8 -8.5 -0.1 2 F 2.7 4.2 21.8 -6.7 -9.4 -6.7 -9.4 -5.3 5.9 -5.7 -9.3 -0.2 2 G 1.6 1.5 12.9 -2.5 -2.8 -2.4 -2.7 -2.2 2.4 -2.0 -2.4 -0.1 SeiisFRM UNE COL UNE RV g t E0.0 9 HORZ LLMa 2 A 0.0 0.0 2 B 0.0 0.0 0.0 2 C 0.0 0.0 0:0 2 D 0.0 0.0 0.0 2 E 0.1 -0.3 -0.2 2 F 0.2 0.0 0.0 2 G 0.1 -0.3 -0.2 ENDWALL COLUMN: MAXIMUM REACTIONS, ANCHOR BOLTS, &BASE PLATES REALOAD FRM COL LOAD HMACOLUMV HMSN) V ANC BOLT BASF -PLATE (IN) ELEV. UNE UNE ID H VMAX ID H VMIN QTY DIA WIDTH LENGTH THICK (in) 2 A 9 1.5 -1.5 10 -1.3 -1.3 4 0.750 8.000 8.000 0.250 0.0 1 0.0 1.8 9 1.5 -1.5 2 B 9 3.5 -5.2 10 -3.2 -5.2 4 0.750 8.000 8.000 0.250 0.0 1 0.0 4.9 9 3.5 -5.2 2 C 11 4.5 -4.7 10 -4.1 -4.7 4 0.750 8.000 8.000 0.250 0.0 1 0.0 4.4 11 4.5 -4.7 2 D 12 5.4 -1.8 13 -5.0 -1.8 4 0.750 8.000 8.000 0.250 0.0 1 0.0 4.8 12 5.4 -1.8 2 E 12 4.5 -3.9 13 -4.1 -3.9 4 0.750 8.000 8.000 0.250 0.0 2 0.0 14.2 12 4.5 -3.9 2 F 14 3.5 -4.0 13 -3.2 -4.0 4 0.750 8.000 8.000 0.375 0.0 2 0.0 24.5 14 3.5 -4.0 2 G 14 1.5 -0.8 13 -1.3 -0.5 4 0.750 8.000 8.000 0.250 0.0 2 0.0 14.4 14 1.5 -0.8 WIND COLUMN REACTIONS d: REACTIONS -WALL- COL HORZ VERT MOMEHT ANC -BOLT BASE3LATE(IN LOC UNE UNE R/L LOADJD (I (k) (f-k) QTY DIA WIDTH LENGTH THICK M F_SW A 1 R WIND 15.1 114.5 228.9 4 1.000 8.000 8.000 1.000 SEISMIC 0.1 1.0 2.1 i B_SW G 1 L WIND 15.1 114.5 228.9 4 1.ODO 8.000 8.000 1.000 SEISMIC 0.1 1.0 2.1 Vf H+V FLOOR COLUMN REACTIONS DEAD Call LIVE FRAME COL Max_Vert VERT VERT VERT ANC BASE Plate (IN) ELEV. UNE LINE Ld (k ) (k ) (k ) -BOLT (k ) 07Y DIA WIDTH LENGTH THICK (in) 1 F 2 25.1 2.1 0.0 23.0 4 0.750 6.000 8.000 0.500 0.0 1 E 2 13.0 1.1 0.0 11.9 4 0.750 6.ODO 8.000 0.500 0.0 d: REACTIONS k Panel. -WALL- COL-WND- -SEIMC - lb, LOC UNE UNE HORZ VERT HORZ VERY WIND F_SW A VENDID CO�MN IN WAT ALL L SSW 0 WIND COLUMN IN WALL 24 ANCHOR BOLT SUMMARY P(in) QTY LOCATE (i) TYPE O 4 JAMB 5/8' A307 1.50 928 ENDWALL /R' A307 1.50 6/ 4 FRAME 1' A307 3.00 X 4 FRAME 1 rA307 3.50 04 FRAME 3 4' A307 2.50 tB 8 WINDCOL 1' A307 3.00 ® 8 FLOOR 3/4- A307 2.50 STmL ES' (S Sl-lSTFjrU% INC. REVISIONS LIBERTY BAPTIST CHURCH 5 14-12-272 12 22 14 LOCATION: 5 FORT PIERCE, FL DRAWING NAME: SCALE; ANCHOR BOLT REACTIONS NONE DRAWING NO: DRAWN In: CHECKED Dr. PAGE 1 -4 1 'LAcc Gregory S. Barfield, P.L. ,`2149 Nell Purvis Road ,Adel, GA 31620 -P.E. # 54419 STRUCTURAL STAMP 2 -11 I r it I I 0 � z J ' m 0 � z 1 U) X I I LLJ II I I II 1 L----------- . OF STEEL of o E�I_ I►�,1_ 14, II II_ II la\IAI IA\IAI_ I\ �I oI P-2 10x25Z14 24'-9 1%2" P-3 10x25Z12 24'-9 1/2 P-4 10x25Z12 24'-9 1/2 E-1 10ES14®4 24'-9 1/2 E-2 10ES14@4 24'-9 1/2 CB-1 3/8 CBL 28'-3 116 CB-2 3/8 CBL 27'-9 3 16" CB-3 5/16 CBL 28'-3 1/4" CB-4 5/16 CBL 28'-4 3/16" CB-5 1/4 CBL 28'-4 1/16 C8-6 1/4 CBL 28'-5 116" PURLIN BRACE (TYP.) * ROOF FRAMING PLAN *SEE PAGE 2.2 FOR PURLIN BRACE DETAILS. NOTE: FIELD REAM EAVE STRUTS AT 5/8' BOLT LOCATIONS. mSTEEL ANC=— S'mSTElXNS wc. LIBERTY. BAPTIST REVISIONS 14-1 A [t LOGTION: Ff1RT Gregory S. Barfield, P.E: L.2149 Nell Purvis Roa1X� LAdel, GA 31620 - P.E. # 54419 STRUCTURAL STAMP MSS MARK 5P-2 14 2 0 A395 5/R: 9 11, I RF1-7 14 A325 5/8' 2 1/Y 1 IFB2 1 FB3 ,%4" 12 �r 9 RF1-2 RF1-3 12.0/12.0 0. % 12.0/12.0 0. RF1-4 12.O/12.0 0. 12.0/12.0 0. RF7-5 12.O/12.0 0. 12.0/1.0. " 12.0/14.3 0. ~' 14.3/21.0 0. RF1-6 21.0/21.0 0. O 21.0/ 9.9 0. 9.9 8.5 0. RF1-7 B12 5.6 5/16. ~� 12'� . ,f 2�Z 73L7p, 9 KW1U YKAML tLtVA11UN: I KAML LINE 1 3'tlb - 011/4' S x 1%4• x 1-1U7 16- 1'-5 1(8- 11'-11 5 x 1/4* x 20*-0• 11'-11' S x 1/4 x 11 -3' 7'-9 118' 11'-11 5 x 1/4" x 14'-10 3/8" 2'-11 3/8 2'-11 1/2" S x 1/4' x 14'-10 1/2' 11'-11" 3'-1, S x 1/4' x 10� 5 5/8. 11'-11• 5 x 1/4 x 20-0" 4'-1 3(4• 11'-11 2'-2 518" S x 1/4' x 1'-10 9/16' S x 1/2 x 15'-0 3/16 1�-511 O kcH, ,j• 4•�, 12 X 1/9, x 1U-11 1(16- 5 x 1/4 x 3'-0 1/4 5 x 1/4" x 20'-0" 5 x 1/4" x 11'-7 1/8' 5 x 1/4• x 14'-6 1/4" 5 x 1/4' x 14'-6 3/8' 5 x 1/4* x 15'-0' 5 x 1/4 x 16-0 15/16" 5 x 1/4" x 13'-5 3/16" Gregory S. Barfield, RE, .,2149 Nell Purvis Road . EAdel, GA 31620 LP.€. # 5441% STRUCTURAL STAMP B= STEEL AI ■ r IqG S'JSTE/XNS INC. CUSTOMER: LIBERTY BAPTIST CHURCH / REVISIONS XB NO: 14-12-272 17 2 22 14 TDCA110N: D2/11/15 FORT PIERCE, FL 35/07/15 BRAxNcNWE RGID FRAME CROSS SECTION s NONE ORAMN0 N0: um" W. CHECKED W. )5/21/15 PAGE 2.1 MSS EAVE 11 (2) ff12x1 1/4" SCREWS (GALVALUME) PURLIN BRACING DETAILS (SEE PAGE 2 FOR PURLIN BRACE LAYOUT) (4) #12x1 1/4" SCREWS (GALVALUME) 8" SPLICE LO O OJ 11 11 (4) #12x1 1/4" SCREWS (GALVALUME) NOTE: MINIMUM SPLICE LENGTH. SPLICE LENGTH = GAP + 8". .. I- -.. - ___.. - 111ifficM H/S EAVE @ SINGLE SLOPE 1 (2) #12x1 1/4" SCREWS (GALVALUME) Gregory S. Barfield, P.E. l 2149 Nell Purvis Road EAdel, GA 31620 1 P.E. # 54419 SBS SUPPLIES CABLES CUT TO THE NEAREST FOOT LONGER THAN THE REQUIRED LENGTH. FOLLOW THESE INSTRUCTIONS FOR CABLE INSTALLATION. [1] INSTALL ONE END OF THE CABLE FOLLOWING THE INSTRUCTIONS OF THE GRIP MANUFACTURER. [2] INSTALL THE EYEBOLT AND HILLSIDE AT THE OPPI CABLE END. [3] HOOK GRIP THROUGH EYEBOLT. [4] PULL CABLE TIGHT AND MARK LENGTH TO MATCH INSTALLATION MARK ON THE GRIP. [5] CUT CABLE TO LENGTH. CAB ABLE COLUMN 0 RAFTE HILLSIDE HILLSIDE :OLUMN OR AFTER [6] INSTALL CUT END OF THE CABLE FOLLOWING THE INSTRUCTIONS OF THE GRIP MANUFACTURER. [7] TENSION CABLE AS REQUIRED. COLUMN 0 RAFTE HILLSIDE [Ha1 m fm STEEL I A TsM S'dSTEMS tNm usrouQt LIBERTY BAPTIST CHURCH REVISIONS I __ "-.14-12-272 F12/22/14 I HILLSIDE :OLUMN OR :AFTER Gregory S. Barrald, P.E. k2149 Nell Purvis Road LAdel, GA 31620 LP.E. # 54419 STRUCTURAL STAMP PAGE 2.3 MSS 24'-10" OUT -TO -OUT OF STEEL J W W F- ) v r I---------J MEZZANINE LAYOUT FLOOR HEIGHT = 10'-0" MEZZANINE FLOOR LOADS DEAD LOAD = 10.0 PSF LIVE LOAD = 125.0 PSF P LAN �S STEEL BLJI-DIr S1:1STEMS wc. REVISIONS 1------14-12-272 _ .12/22/14 F Gregory S. Barfield, P.E. [`2149 Nell Purvis Road Adel, GA 31620 k o P.E. # 54419 STRUCTURAL STAMP 9?X 02/11/15 FORT PIERCE, FL [21 DMMO wwe senE: 05/07/15 MEZZANINE LAYOUT NONE [3] VR NG NO: OMWN W. CNECNED St.. 05/21/15 PAGE 2.4 MSS N N 1 24'-10" OUT -TO -OUT OF STEEL 2 RI A 2 A325 5/8" 2 1 SUPPORT COLUMN BOLT TABLE ❑ ID I QTY TYPE DIA LENGTH C1 1 4 A325 5 8 2 1 2 mt5 1 []ILh IJ.Cf IJ-I I IJ 10 MB-2 612X17.9 14-11 7 8" MB-3 B12X15.5 1 14-11 3/4" MB-4 B12X13.8 13'-11 3 4" MB-5 B12X13.8 23'-5 1 2' MC-1 B8X11.9 9'-0" MEZZANINE FRAMING LAYOUT FLOOR HEIGHT = 10'-0" MEZZANINE FLOOR LOADS DEAD LOAD = 10.0 PSF LIVE LOAD = 125.0 PSF e:7 SrEEM_ E JLDWr7 S�-JSTEMS INC. REVISIONS _ "-14-12-272 1 6 15 [1]02/11 15 EaGrD FORT PIERCE, FL [2] DRAWING WAIF SCAlE 05/07/15 MEZZANINE FRAMING NONE [0] DRAWING NO: DMWN W. CHECKED D(: 05/21/15 PAGE 2.5 MSS Oil CINIA Gregory S. Barfield, P.E. ,,2149 Nell Purvis Road ` Adel, GA 31620 ; P.E. # 54419 STRUCTURAL STAMP 7 RF1-6 3* 4" 9'-4" 10'-0" SIDEWALL FRAMING: FRAME LINE A 5'-6" EC-1 BOLT TABLE FRAME LINE A & G LOCATION QUAN TYPE DIA LENGTH WF-1 - RF1-6 8 A325 5 8 2 1 2 WF-1 - RF1-1 8 A325 5 8" 2 1/2" SPECIAL BOLTS O ID QUAN TYPEDIA LENGTH WASH 1 1 2 A325 5 8 2 1/2" 2 LO I 2 1 24'-10" OUT -TO -OUT OF STEEL 2 4" E-2 F II II °' II 1n II II G-8 Le II II `° u 0 H9 DH-1to M II K3 II in G-7 II ,n ^ o II i II 2x4x14AN RF1 -1 EC-7 3* 4" SIDEWALL FRAMING: FRAME LINE G *FIELD LOCATE (2) 3070 PERSONNEL DOORS WITH JAMBS PER OWNER'S ®� LOCATIONS.FILL , MEMBER TABLE FRAME LINE A & G MARK PART I LENGTH WF-1 B24X26 14 -0 DJ-1 8X35C16 10'-3" DJ-2 8X35C14 15'-4 1/8" DJ-3 8X35C14 15'-4 1/8" DH-1 8X25C16 3'-4' OH-2 8X25C16 10'-0" E-1 10ES14@4 24'-9 1/2 E-2 10ES14@4 24'-9 1/2, G-5 8x25Z16 6'-7 1/2 G-6 8x25Z16 5'-1 1/2„ G-7 8x25Z14 21'-9 1/2" G-8 8x25Z12 21'-9 1/2" 4mm STEEL BLJIL.I7WG SySTElX\S INC. CUSTOMER: LIBERTY BAPTIST CHURCH REVISIONS JOB NO: DATE: 14-12-272 12/22 14 L anow D2 11 15 FORT PIERCE, FL DRANNO NAME: SCRLE: SIDEWALL FRAMING LAYOUT NONE DRAMG NO: DRAWN W. CHECKED W. PAGE 3 1 MSS Gregory S. Barfield, P.E. 112149 Nell Purvis Road LAdel, GA 31620 LP.E. # 54418, STRUCTURAL STAMP [1] SECURE THE PERSONNEL DOOR JAMBS TO THE FLOOR USING (2) 1/2" WEDGE ANCHORS AT EACH JAMB. [1] TEMPORARILY BRACE THE PERSONNEL DOOR UNTIL THE FRAMED OPENING IS INSTALLED. ALL "SBS" PERSONNEL DOORS COME FACTORY PREPPED AS RIGHTHAND REVERSED SWING. (i.e. STANDING ON THE OUTSIDE OF THE BUILDING FACING THE DOOR, THE LOCK WILL BE ON THE LEFTHAND SIDE OF THE DOOR AND THE DOOR WILL SWING OUTWARD FROM THE BUILDING. ) ANY FIELD MODIFICATIONS ARE THE RE— SPONSIBILITY OF THE ERECTOR AND "SBS" IS NOT LIABLE FOR LABOR CHARGES NOR DAMAGES DUE TO ERROR. [3] DEPENDING UPON THE SIZE OF THE PERSONNEL DOOR, INSTALL THE RED .IRON JAMBS 3'-4", 4'-4" OR 6'-4" APART (MEASURING INSIDE TO INSIDE OF THE JAMBS). USE (2) M.5x1.5 BOLTS AND (2) 5/8" WEDGE ANCHORS PER JAMB. [4] INSTALL THE HEADER TO THE JAMBS USING (4) M.5x1.5 BOLTS. [5] INSTALL GIRTS TO THE JAMBS USING (2) M.5x1.5 BOLTS PER GIRT. NOTE: IF THE PERSONNEL DOOR IS FIELD LOCATED, THE GIRT MUST BE FIELD CUT TO FIT. [6] WHEN THE WALL SHEETING REACHES THE PERSONNEL DOOR, SECURE THE DOOR TO THE HEADER BY INSTALLING SCREWS THAT WILL FALL UNDER A PANEL HIGH —RIB. mSTEEL r7 S'JSTE/XXS INC. REVISIONS --- .--.14-12-272 -" 12 22 14 i �Danax: FORT PIERCE, FL [2] DRAMS NA11E: SCALE` PERSONNEL DOOR INSTALLATION NONE [31 DWONG ND: DRAWN BY: CHECKED BY: PAGE 3.1 MSS Gregory S. Barfield, P.E. t 2149 Nell Purvis Road Adel, GA 31620 L P.E. # 54419 STRUCTURAL STAMP 90'-0" OUT —TO —OUT OF STEEL MC-1 MC-1 ENDWALL FRAMING: FRAME LINE 1 4"t�!t, 12 mi 4'b!-,, 12 0= 0� I �o I � N � J = BOLT TABLE FRAME LINE 1 & 2 LOCATION I QUAN TYPE DIA LENGTH ER-1 ER-2 4 A325 b/d-- 2 1 2 ER-2/ER-3 3 A325 5/8" 2 1/2" ER-3/ER-4 4 A325 5/8" 2 1/2" COLM RAFT 2 A325 5 8 2 1 2 MEMBER TABLE FRAME LINE 1 & 2 MARK PART LENGTH EC-1 8X25C14 14 —6 EC-2 8X5DC12 19'-2" EC-3 B8X11.9 24'-2" EC-4 B8X16 29'-2" EC-5 B8X11.9 24'-2" EC-6 B8X11.9 19'-2" EC-7 B8X11.9 14'-3 3/8" ER-1 8X25C12 30'-9 7/8 ER-2 8X25C12 16'-9 3/4 ER-3 8X25C12 16'-9 3/4 ER-4 8X25C12 30'-9 7/8" DJ-4 8X35C16 9'-1' DH-3 8X25C16 3'-4" G-1 8x25Z16 13'-7 1/2" G-2 8x25Z16 14'-3 1/2 G-3 8x25Z14 14'-3 1/2, G-4 8x25Z16 13'-3 1/2" G-9 8x25Z16 7-11 2" G-10 8x25Z16 2'-3 1/2 " MB-1 B12X13.8 13-11 116" MB-2 B12X17.9 14'-11 7/8 " MB-3 B12X15.5 14'-11 3/4" MB-4 612X13.8 13'-11 3/4" MC-1 BBX11.9 9'-0" MAI ul j � asaa . 19 Gl.- I CV-L CV-J p Gl..-4 Gl.-O EC-6 EC-7 I I STEM— Eil A Mir' SySTEfr%S Plc. ENDWALL FRAMING: FRAME LINE 2 REVISIONS 14-12-272 —12 22 14 [i1 inanoN: 02/11/15 FORT PIERCE, FL [21 DMWNG x Z. OS 07/15 ENDWALL FRAMING LAYOUT NONE [s1 Gx MO No- GxnwN ae cxec�G a.OS/91 /15 PARF 4 AAQC Gregory S. Barfield, P.E. �2149 Nell Purvis Road Adel, GA 31620 e P.E. # 54419 STRUCTURAL STAMP DETAIL IS DETAIL A7 DETAIL B4 DETAIL B6 4" GIRT DEPTH PURLIN (IF BYPASS) 4" GIRT DEPTH PURLIN (IF BYPASS) RAFTER RAFTER Fo ® RAKE ANGLE Fo ®� �— RAKE ANGLE I I. 12x1 1/4" I 1 W/(2)#12x1 1/4" I I SCREWS I I SCREWS P(2)H.63x2.5* p(2)H.663x2.5* 10 (2) M.5x1.5 * 10 (2) M.5x1.5 RAFTER RAFTER COLUMN COLUMN (CEE OR DBL CEE) i (BUILT—UP) — J * UNLESS NOTED ON PAGE 2. * UNLESS NOTED ON PAGE 2. *UNLESS NOTED ON DRAWING 4. *UNLESS NOTED ON DRAWING 4. PURLIN TO ENDWALL RAFTER PURLIN TO ENDWALL RAFTER COLUMN / RAFTER CONNECTION COLUMN./ RAFTER CONNECTION DETAIL C5 DETAIL C6 DETAIL C14 DETAIL C15 COLUMN [DOUBLE CEE] COLUMN [BUILT—UP] COLUMN EW GIRT COLUMN EW GIRT [DOUBLE CEE] [DOUBLE CEE] EW GIRT EW GIRT EW GIRT EW GIRT r®I ®I I® ®I 1® ®1 I I I I I I I J J I I LI J (2) M.5x1.5L (2) M.5x1.5 (2) M.5x1.5 2.x. (2M.S.(.0.5 x1) ENDWALL GIRTS TO INTERIOR COLUMN ENDWALL GIRTS TO INTERIOR COLUMN ENDWALL GIRT STOPPING AT COLUMN ENDWALL GIRT STOPPING AT COLUMN un� =, ^00771)y ij Gregory S. Barfield, P.E. 2149 Nell Purvis Road; STRUCTURAL STAMP Adel, GA 31620 P.E. # 54419 STEEL LNG S"JSTE/XkS uvc. CUSTOMER: LIBERTY BAPTIST CHURCH. REVISIONS JOB NO: OATS 14-12-272 12 22 14 TIT__ LOCATION: FORT PIERCE, FL [21 DRAWING NAME SCALE FRAMING DETAILS NONE [}] DRAWING N0: DRAWN W.CHECKED BY: PAGE 5 MSS DETAIL D4 DETAIL D6 DETAIL @ DETAIL E4 I I EW GIRT ® ®� EW GIRT I I BASE PLATE I BASE PLATE 10 (2) M.5x1.5 I I (NP) COLUMI I I COLUMN [BUILT - I I [SINGLE CEE] (4) 3/4" DIA. O ®o (4) DIA. O ®O L® ®J ) M.5x1.5 COLUMN [BUILT-UP] ®O ®O i COLUMN OLUM [DOUBLE CEE] O® ®O _ (T'P) I I CORNER ANGLECORNER ANGLE (IF REQ'D)(IF REQ'D) GIRT DEPTH, GIRT DEPTH, EDGE OF SLAB (IF BYPASS), EDGE OF SLAB (IF BYPASS), SW GIRT (2)#12x1 1/4" SW GIRT )#2x 1 1 /4" I I SCREWS SCREWS GIRTS TO CORNER COLUMN GIRTS TO CORNER COLUMN ENDWALL COLUMN BASE DETAIL ENDWALL COLUMN BASE DETAIL DETAIL E5 DETAIL E8 DETAIL F7 DETAIL 0- RAFTER [ANY TYPE] OE I RAFTER I [SINGLE CEE] z BASE PLATE I z w o I (4) 3/4" DIA. I JAMB o o® COLUMN , [SINGLE CEE] (2) 5/8" DIA. , COLUMN [ANY TYPE] EDGE OF SLAB EDGE OF SLAB GIRT DEPTH, {IF BYPASS), k SEE PAGE 4 FOR SIZE AND QUANTITY OF BOLTS. I * SEE PAGE 4 FOR SIZE AND QUANTITY OF BOLTS. FRAMED OPENING JAMB BASE DETAIL ENDWALL COLUMN BASE DETAIL RAFTER DETAIL AT SPLICE RAFTER DETAIL AT RIDGE W/ CENTER COLUMN Gregory S. Barfield, P.E. 2149 Nell Purvis Road Adel, GA 31620 P.E. # 54419 - STE:EL B L9 PY1S SySTEfXXS INC. BAPTIST CHURCH REVISIONS ___'_ 14-12-272 1 12 22 14 [1] LDGIIGN: FORT PIERCE, FL [2] DRAWING NAME: SCALE: FRAMING DETAILS NONE 131 DRAWING M. DRAWN Bh CHECKED W. PAGE 5.1 MSS STRUCTURAL STAMP DETAIL H9 DETAIL I6 DETAIL J1 DETAIL K3 (2) M.5x1.5 SAVE STRUT (2)H.63x2.5 WIND COLUMN I I (NP) EAVE STRUT (2) M.5x1.5 GIRT JAMB IREQ'D] [IF I I m m — I ® — — — ® I COLUMN [MAINFRAME] RAFTER I� I -COLUMN [SINGLE CEE] I I I I [MAINFRAME] I I I I --_j A/BOLTS I (2) M.Sx1.5 (2) M.5x1.5 *UNLESS NOTED ON PAGE 2. * UNLESS NOTED ON PAGE 2. i WIND COLUMN DETAIL EAVE STRUT CONNECTION AT ENDWALL EAVE STRUT CONNECTION AT MAINFRAME GIRTS TO JAMB DETAIL @ DETAIL L8 DETAIL M2 DETAIL Q2 (2) H.5x1.25 EAVE STRUT (2) H.5x1.25 JAMB CABLE GIRT COLUMN OR RAFTER [ZEE/CEE] NGRIP®HEADER/SILLJAMBJAMB — _ (2) M.5x1.5 HILLSIDE FRAMED OPENING JAMB TO EAVE STRUT FRAMED OPENING JAMB TO GIRT FRAMED OPENING HEADER/SILL TO JAMB CABLE INSTALLATION DETAIL L C Glcyory S. Bafield, P.E. 2149 Nell Purvis Road; LAdel, GA 31620 L P.E. # 54419,, REVISIONS -14-12-272 12 22 14 �] LOWON: FORT PIERCE, FL [2] DRAWING NAME SCAM FRAMING DETAILS NONE 131 DRAWING ND: DRAWN W. CHECKED BY: PARF fig MSS STRUCTURAL STAMP DETAIL T1 NOTE: THE PROPER TIGHTENING AND INSPECTION OF ALL FASTENERS IS THE RESPONSIBILTY OF THE ERECTOR. ALL HEAVY STRUCTURAL (A325,A490) BOLTS AND NUTS MUST BE TIGHTENED BY THE "TURN —OF —NUT" METHOD SHOWN BELOW. A325 AND A490 BOLTS ARE DESIGNATED BY "SBS" WITH NAIL ANCHOR A "H". (ex: H.63x2.0 OR H.75x2.75) (24" ON CENTER) TURN —OF —NUT TIGHTENING: BOLTS SHALL BE INSTALLED IN ALL HOLES OF THE CONNECTION AND BROUGHT BASE ANGLE TO A SNUG —TIGHT CONDITION. SNUG TIGHT IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN THE PLIES OF THE JOINT ARE IN FIRM CONTACT. THIS MAY BE AT— TAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A EDGE of SLAB T MAN USING AN ORDINARY SPUD WRENCH. SNUG TIGHTENING SHALL PROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART OF THE CONNECTION TO THE FREE EDGES UNTIL ALL BOLTS ARE SIMULTANEOUSLY SNUG TIGHT AND THE CONNECTION IS FULLY COMPACTED. FOLLOWING THIS INITIAL OPERATION ALL BOLTS IN THE CON— NECTION SHALL BE TIGHTENED FURTHER BY THE APPLICABLE AMOUNT OF ROTATION SPECIFIED IN THE TABLE BELOW. DURING THE OPERATION THERE SHALL BE NO RO— TATION OF THE PART NOT TURNED BY THE WRENCH. TIGHTENING SHALL PROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART OF THE JOINT TO THE FREE EDGES. BASE ANGLE DETAIL NUT ROTATION FROM SNUG —TIGHT CONDITION BOLT LENGTH REQUIRED ROTATION UP TO AND 1/3 TURN INCLUDING 4 DIAMETERS OVER 4 DIA- 1/2 TURN METERS BUT NOT EXCEEDING 8 DIAMETERS OVER 8 DIA- 2/3 TURN METERS BUT NOT EXCEEDING 12 DIAMETERS NOTES:[1] NUT ROTATION IS RELATIVE TO BOLT REGARDLESS OF THE ELEMENT (NUT OR BOLT) BEING TURNED. [21 APPLICABLE ONLY TO CONNECTIONS IN WHICH ALL MATERIAL WITHIN THE GRIP OF THE BOLT IS STEEL. f f Gregory S. Barfield, P.E. �,2149 Nell Purvis Road LAdel GA 31620; LP.E. # 54419, STRUCTURAL STAMP _ CN N O I O I I I I I * I I m I N I I I I o M N I to I O I E I I I . 0 I N * I m I I I N I I i * I _ 4 N I I I NOTE TO THE ERECTOR PANEL MANUFACTURERS WILL NO LONGER BE PACKAGING PANELS WITH COVER SHEETS. PANELS WILL NOW BE PACKAGED WITH WASTE PAPER. 0 J w w !n 1 0 O I F 0 0 2 SkLT TRM 8'-5" 3 RAKECLOS 20'-3" 4 RAKECLOS 8'-0.1 5 RAKEFLSH 20'-3" 6 RAKEFLSH 8'-0" ROOF SHEETING PLAN PANELS: 26 GA. R - GALVALUME FL# 1 1868.1 * FL# 13793.1 SOS STEEL Br m nWG S�JSTE/X15 wc. LIBERTY BAPTIST CHUF REVISIONS 408 No: 14-12-272 LD T'Om: 02/11/15 FORT PIERCE, FL OMWND N E: ROOF PANELS & TRIM DMA G NO: PAGE 6 4 Gregory S. Barfield, P.E. ,12149 Nell Purvis Road Adel, GA 31620 P.E. # 54419 STRUCTURAL STAMP W, EXISTING ROOF EXISTING F Tn, r.r.n T.nr ore, ro ROOF FLASHING DETAILS SECTION X1 REVISIONS 02/11/15 NEW ROOF PANEL Y11flIW 1111M/ �✓ Gregory S. Barfield, P.E. ,,2149 Nell Purvis Road L Adel, GA 31620 - P.E. # 54419 STRUCTURAL STAMP SBS STEEL BUILDWS S"JSTEfnS INC. USTOMER: IIBFRTY BAPTIST CHURCH 14-12-272 12 22 14 e !/ FORT PIERCE, FL ROOF PANEL DETAILS NONE \J GIB/1^C NO: DRAWN BY: CNECXEO V: PAGE 6.2 HEF HEF EXISTING ROOF R . ,. .. _ I- ....... ...- .. r.__.. rn. n'.n i.nl II.. In ROOF FLASHING DETAILS SECTION X2 NEW ROOF PANEL ME w I11.410i 1 Sal STEEL Bu LDWG SL-JSTE/%15 INC. USTOMER: LIBERTY BAPTIST CHURCH REVISIONS 14-12_272 12 22/14 Loon D2/11/15 FORT PIERCE, FL DmmG ME: SCNE: ROOF PANEL DETAILS NOP OMMG NO: OR WN W. CHECKED 9 PAGE 6.3 HEF HEF Gregory S. Barfield, P.E. 1,2149 Nell Purvis Road LAdel, GA 31620 LP.E. # 54419 STRUCTURAL STAMP J —4 (e-ts (SEE DETAILS FC PANEL END 1 INSIDE CLOSU x A9�F! ry�c� �FSs NOTES: [1] ALL END LAPS MUST BE A MINIMUM OF 6". [2] METAL SHAVINGS MUST BE SWEPT FROM THE ROOF EACH DAY DURING ERECTION TO PREVENT SURFACE RUSTING. [3] TAPE SEAL MUST BE APPLIED WITH NO GAPS OR BREAKS. [4] #12 SCREWS ARE USED TO ATTACH THE PANEL TO THE PURLINS. #14 LAP SCREWS ARE USED AT THE PANEL —TO—. PANEL ATTACHMENTS. ALL FASTENERS ARE SELF —DRILLING. PAGE 6.1 2.r 2„ U Y 2rr 2rr O Y 2" 2" LAP SCREW /— CONTINUOUS TAPE SEAL 012 SCREW SIDE LAP DETAIL AT PANEL END 12" 1 12' #12 SCREW DETAIL AT INTERIOR OF PANEL MSS LAP SCREW - CONTINUOUS TAPE SEAL SIDE LAP Gregory S. Barfield, P.E. ,,2149 Nell Purvis Road L Adel, GA 31620 , P.E. # 54419 STRUCTURAL STAMP 4 a O (GUTTER W/ 2 DOWNSPOUTS) 5 6 19 0 ❑ 9❑ 1 I. I I _ I I I I O I o I I 1p - (p I I , 10 ip I I <0> 0 ' ** I ' I I I SIDEWALL SHEETING & TRIM: FRAME LINE A PANELS: 26 GA. R - WALL COLOR FL#11917.4 * FL#10294.1 * * FL# 12152.1 I I (GUTTER W/ 2. DOWNSPOUTS) _ 7 8 5 6 19 0 [1 1 I I I I I O O I I O I I O I O I O I O I O 1 O I io I io io io io io O I I Q I I I I I TRIM TABLE FRAME LINE A & G OID PART LENGTH 1 BASE TRM 9 -6 2 BASE TRM 5'-6" 3 R JAMB 16'-3" 4 O/S CORN 16'-0" 5 GUTTER 20'-3" 6 GUTTER 5'-0" 7 GUTEND L 8 CORBOX L 9 GUTEND R 10 CORBOX R 11 R JAMB 7'-5" 12 R HEAD 3'-7" 13 JB/HDCAP 10'-3" 14 R JAMB 10'-3" - 15 JB/HDCAP 10'-3" 16 R HEAD 10'-3" 17 BASE TRM 20'-3" 181 BASE TRM 5'-0" 19 PANL CAP 20'-3" 20 PANL CAP 5'-0" NOTE TO THE ERECTOR PANEL MANUFACTURERS WILL NO LONGER BE PACKAGING PANELS WITH COVER SHEETS. PANELS WILL NOW BE PACKAGED WITH WASTE PAPER. SIDEWALL SHEETING & TRIM: FRAME LINE G PANELS: 26 GA. R - WALL COLOR FL#11917.4 * FL#10294.1 SE35 STEEEI_ BUfLOING S�-SSTEfXNS INM BAPTIST CHURCH REVISIONS 14-12-272 1 12/22/14 1 15 1 FORT PIERCE. FL 11/15 1 SIDEWALL M Gregory S. Barfield, P.E. 2149 Nell Purvis Road Adel, GA 31620 P.E. # 54419 STRUCTURAL STAMP LAP S( (20" C 12 SC (SEE DET ILS FO BASE SUPPORT PANEL E INSIDE CL NOTES: [11 METAL SHAVINGS MUST BE SWEPT FROM THE WALL EACH DAY DURING ERECTION TO PREVENT SURFACE RUSTING. [21 #12 SCREWS ARE USED TO ATTACH THE PANEL TO THE GIRTS. #14 LAP SCREWS ARE USED AT THE PANEL —TO — PANEL ATTACHMENTS. ALL FASTENERS ARE SELF —DRILLING. . ,. TL T I . Y 2.. 2.. t It #12 SCREW DETAIL AT PANEL END DETAIL AT HEADER/SILL DETAIL AT PARTIAL WALL ,�— LAP SCREW SIDE LAP 12" 12" LAP SCREW #12 SCREW SIDE LAP DETAIL AT INTERIOR OF PANEL EJ L py �r1 Adel, GA .149 Nell 16 0 ad SLAB . P.E. # 54419 aELow She mSTEEL ®IJc1_DNC- 5L-JSTEfnS wr-. U=mm: LIBERTY BAPTIST CHURCH REVISIONS I---"-.14-12-272 72/22/14 1 STRUCTURAL STAMP S -Z� —( PAGE 7.1 r.. MSS NONE 2 RAKE TRM 20'-3" 3 RAKE TRM 7'-6" 4 PEAK BOX 5 BASE TRM 20'-3" / \ 6 BASE TRM 10'-0" 8 R O/SJAMB RN 17'_5� / / / I 9 R HEAD 3'-7" 124• /� \� ate, 12 I , I OPEN AND COMMON I I I , L----------------------------------------- J ENDWALL SHEETING & TRIM: FRAME LINE 1 I I I I I I I 12 o a12 .� 1 3 / Y J N N M N I *PFILE 0. _ 1 O O O I OO O p O ^ wl q N N N N N N N m I O m r l O ° ° Gregory S. Barfield, P.E. ,2149 Nell Purvis Road'. LAdel, GA81620 P.E. # 54419 ENDWALL SHEETING & TRIM: FRAME LINE 2 PANELS: 26 GA. R - WALL COLOR FL#11917.4 NOTE TO THE ERECTOR PANEL MANUFACTURERS WILL NO LONGER BE PACKAGING PANELS WITH COVER SHEETS. PANELS WILL NOW BE PACKAGED WITH WASTE PAPER. O'Eft-11 STEEL SuL r4s— SL.JSTEMS ... LIBERTY BAPTIST CHURCH aoH No- wiE 14-12-272 12 22 14 011 WMON: 05/21/15 FORT PIERCE, FL [21 ORAWWC NAME SfAI.E ENDWALL PANELS & TRIM NONE 31 DRAWING NO: DftAWN HY: CNECM BY: PAGF 8 MSS STRUCTURAL STAMP .5 " Gtp I,) EEI-OVY 1 1 /2. RAKE SUPPORT SCREW )" O.C.) SCREW \ILS FOR LAYOUT) BASE SUPPORT :ND WITH ;LOSURES NOTES: [11 METAL SHAVINGS MUST BE SWEPT FROM THE WALL EACH DAY DURING ERECTION TO PREVENT SURFACE RUSTING. [21 #12 SCREWS ARE USED TO ATTACH THE PANEL TO THE GIRTS. #14 LAP SCREWS ARE USED AT THE PANEL —TO — PANEL ATTACHMENTS. ALL FASTENERS ARE SELF —DRILLING. 2" 2„ ,-LAP SCREW #12 SCREW SIDE LAP DETAIL AT PANEL END DETAIL AT HEADER/SILL DETAIL AT PARTIAL WALL 12" 12" LAP SCREW #12 SCREW SIDE LAP DETAIL AT INTERIOR OF PANEL U Gregory S. Barfield, P.E. Copy �,2149 Nell Purvis °APE.#54419oad STRUCTURAL STAMP dm STEEL. BLEMNS SLdSTEMS wc. CUSTOMER: LIBERTY BAPTIST CHURCH REVISIONS JOB NO: CATI 14-12-272 12 22 14 LOCATION: FORT PIERCE, FL OMWMO NAME: SCA1F: ENDWALL PANEL DETAILS NONE OMWMO NO: OMWN BY: CHECKED BY: PAGE 8.1 MSS s -z4 —�5� TRIM NOTES: ROOF PANEL ROLL CAULK I/S CLOSURE [1] SEAL TRIM SPLICES WITH TUBE CAULK. ROOF PANEL #14 SCREWSCREW (12 D.C.) RAKE TRIM (12" ON CENTER) [2] SECURE GUTTER SPLICES AND END PLUGS WITH RNETS. [3] SECURE ALL OTHER ROOF TRIM RAKE TRIM PANEL CAP SPLICES WITH TRIM SCREWS UNLESS �\ GUTTER NOTED OTHERWISE. #14 SCREW [4] TRIM SCREWS ARE LOCATED 12" ON (12' D.C.) CENTER UNLESS NOTED OTHERWISE. WALL PANEL WALL PANEL PEAK BOX NOTE: INSTALL GUTTER STRAPS 3'0" ON CENTER. RAKE TRIM DETAIL PEAK BOX DETAIL GUTTER DETAIL. RIM 13ASE TRIM WALL PANEL WALL PANEL 0/S CORNER TRIM SER I/S CLOSURE BASE TRIM CORNER $14 SCREW (12° ON CENTER) Lj 1 1/2" BASE TRIMWALL EDGE OF SLABENDERORNER PANEL BOX GUTTER END DETAIL BASE TRIM DETAIL BASE TRIM CORNER DETAIL O/S CORNER DETAIL WALL PANEL HEAD TRIM JB/HD CAP (I REOD) #12 SCREW (24° ON CENTER) - F L (24 I/S CLOSURE 13 F r#12 JB HD CAP #12 SCREW (I REQ'D) (12" ON CENTER) SCREW WALL PANEL (24' O.C.) HEAD TRIM AP JAMB TRIM (IF REQ'D) WALL PANEL HEAD TRIM DETAIL AT HEADER HEAD TRIM DETAIL AT SILL JAMB TRIM DETAIL AT JAMB REVISIONS r1_'_*pY ,_S STEEL r\Ir7 S'-JSTFJrm wa. Gregory S. Barfield, P.E. `2149 Nell Purvis ROadj L Adel, GA 31620 P.E. # 54419. STRUCTURAL STAMP PAGE 9 DO NOT INSTALL GUTTER WITH OUTSIDE FACE PERPENDICULAR TO THE GROUND. GUTTER INSTALL GUTTER WITH OUTSIDE FACE PERPENDICULAR TO THE ROOF. 0 FILES INSTALLATION D ETA I L Gregory S. Barfield, P.E. 12149 Nell Purvis Road . Adel, GA 31620 ... P.E. # 54419 GUTTER 'Y' THE BOTTOM OF THE GUTTER AND FOLD THE TABS INTO THE DOWNSPOUT. DOWNSPOUT INSTALL DOWNSPOUT STRAPS 5'-0" ON CENTER. DOWNSPOUT INSTALLATION D ETA I L iP OF THE )OF PITCH. DOWNSPOUT bregory S. Barfield, P.E. 112149 Nell Purvis Road Adel, GA 31620 - t P.E. # 54419 _ STRUCTURAL STAMP 1 2 24'-10" TABLE a v . v v v I I I I I I I I I I I I' I I I I I I I v 0 0 0 0 t o I rn rn rn rn I rn I I I I I I I I I I I I I I I I I ROOF INSULATION INSULATION: 4.00" THICK RE ftaan n COPY LE Gregory S. Barfield, P.E. 2149 Nell Purvis Road - EAdel, GA31620 P.E. # 54419 STRUCTURAL STAMP INSULATION TABLE FRAME LINE A 2 G ROU-1 QUANI MARK I WIDTH LENGTH I I I I I I I 44' t2 � n v o I O m I n iV I n O m .�. o 1 0 O Y N N N O p 1 i7 N N in _I O I I I I ENDWALL INSULATION: FRAME LINE 2 INSULATION: 4.00' THICK RE T y I I I I -1 II II I I I I I I SIDEWALL INSULATION: FRAME LINE A INSULATION: 4.00' THICK RE 1 10 WI-1 6'-0" 17'-0" 2 2 WI-2 6'-0" 19'-0" 3 2 WI-3 6'-0" 21'-0" 4 2 WI-4 6'-0" 23'-0" 5 2 WI-5 6'-0" 25'-0" 6 2 WI-6 6'-0" 27'-0" 7 2 WI-7 6'-0" 29'-0" 8 2 WI-8 6'-0" 31'-0' 9 1 WI-9 6'-0" 1 32'-0" LEGEND: ((ROLL LENGTH #) v 0 .. 0 .. 0 v 0 I I I o I -I^ I I I SIDEWALL INSULATION: FRAME LINE G INSULATION: 4.00' THICK RE �S STEEL. BULDIIVG SysTF-rAs INC. CI Omm: LIBERTY BAPTIST CHURCH REVISIONS JOB NO:14-12-272 oA 12 22 14 [I] IACAIIDN: 02/11/15 FORT PIERCE, FL DRAWING NAME 5r' F. [Z]05/21/15 INSULATION LAYOUT NONE [3] DRAWING NO. DRAWN Bh CHECKED BY: PAGE 10.1 1. MSS Gregory S. Barfield, P.E. 2149 Nelrvi5 Road Adel, GA P.E. # 54419 STRUCTURAL STAMP S 6(e-p ROOF PA�'�' GUTTER INSUI WALE EAVE DETAIL NOTE: FOLD ROOF INSULATION BACK 3" TO 6". L. ^""' WALL PANEL BASE TRIM BASE DETAIL NOTE: FOLD INSULATION BACK 3" TO 6". CAUTION: FAILURE TO FOLD FACING OF INSULATION BACK FROM THE PANEL EDGE AT THE BASE AND EAVE COULD RESULT IN PANEL DAMAGE AND WILL VOID THE PANEL WARRANTY. RAKE DETAIL CORNER DETAIL ROOF PANEL ROOF PANEL SKYLIGHT PANEL RAKE TRIM SKYLIGHT TRIM SKYLIGHT TRIM INSULATION INSULATION J , [1] INSTALL SKYLIGHT TRIM ONTO PURLINS. PURLIN PANEL [2] INSTALL INSULATION OVER SKYLIGHT TRIM. [3] INSTALL ROOF PANEL AND SKYLIGHT PANEL OVER INSULATION. [4] CUT OUT INSULATION FLUSH TO SKYLIGHT TRIM WITH A RAZOR KNIFE. SKYLIGHT TRIM DETAIL O/S CORNER TRIM WALL PANEL REVISIONS STEEL C VG r=L-JSTE/Xi6 wc. :USTOMEN: LIBERTY BAPTIST CHURCH IOB N0: ��' 14-12-272 12/22/14 =n0m: FORT PIERCE, FL 7D, Gregory S. Barfield, P.E 2149 Nell Purvis Road Adel, GA 31620 P.E. # 54419 STRUCTURAL STAMP