Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS Page 1 PROPERTY INFORMATION SCANNED BY Address: 3660 W Midway RdSt LUCie COun O): `y Liberty Baptist Church Inc City / State / Zip: Fort Pierce, FI 34961 Parcel #: 3403-502-0156-100/6 Jurisdiction: SAINT LUCIE COUNTY Zoning: I Lot#: 92 Block: APPLICATION INFORMATION Permit Number: 1502-0307 stories: Automatic Sprinkler System? No Permit Type: COMMERCIAL ADDITION CONTRACTOR INFORMATION Contractor Name: Paul Kuhn Jr Fax Number: Business Name: Heritage Contracting Services Inc Email: Paul.K.Hcs@Gmail.Com Business Addr: 3690 N Us 1 City / State / Zip: Ft Pierce, FI 34946 REVIEWS AND COMMENTS Review Tyne Status Reviewed By Date Started Date Completed pate Released DOCUMENTS MISSING PENDING Audrey Humphrey 2120/2015 2/20/2015 Comment: RECORDED NOTICE OF COMMENCEMENT 2/20/2015 Comment: FILLED LANDS AFFIDAVIT 3/6/2015 Comment: VEG PERMIT FILED UNDER (L) FOR LIBERTY BAPTIST CHURCH - $50.00 FEE ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 3/512015 31512015 Comment: FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 212012015 212012015 V2012015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 3118/2015 3/18/2015 3/18/2015 Comment: PLANS EXAMINER MECHANICAL VOIDED Carl Peterson Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 3/18/2015 3/18/2015 Comment: PLEASE LIST OCCUPANT COUNT FOR EXISTING BLD AND NEW ADDITION ON PLANS 3/18/2015 Comment: PLEASE LIST HOW MANY EXISTING PLUMBING FIXTURES THERE ARE IN THE EXISITING BLD ON PLANS. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Fierce, FL. 34982. Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 2 PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 3/18/2015 Comment: ALL DRAWINGS AND FINAL DOCUMENTS BEING FILED FOR PUBLIC RECORD AND PROVIDED TO THE 3/1812015 OWNER MUST BE SIGNED, SEALED AND DATED IN ORIGINAL FORMAT [ SEE F.S. 471.025 ] THE PLANS FROM FREDERICK SHAEFFER AND GREGORY BARFIELD ARE NOT ORIGINALS' WE DO NOT ACCEPT ELECTRONIC SEALS AT THIS TIME OR PLAN COPIES Comment: WHEN COMPLETE THE BUIDING PLANS FROM SBS MUST BE MARKED REVIEWED AND APPROVED BY 3/18/2015 DESIGN PROFESSIONAL OF RECORD BEING FREDERICK SHAFFER - WE WILL NEED [ 3 ] SETS OF ORIGINAL S.S.D.FINAL DRAWINGS MARKED" FOR CONSTRUCTION"AT RE -SUBMITTAL 3/18/2015 Comment: CERTIFICATION FOR DESIGN LOAD SHEETS ON SHEET 3 ARE INCOMPLETE . DESIGN PROFESSIONAL TO COMPLETE 2012 SUPPLEMENTS, ASD OR LRFD, END ZONE WIDTH, PSF DECK, STAIRS AND RAILINGS Comment: ENGINEER TO STATE THE CONSTRUCTION TYPE ON PLANS PER FBC 602.1 AND IF STRUCTURAL 3/1812015 ELEMENTS ARE PROTECTED OR UN -PROTECTED [ A OR B ] " IS THE BUILDING SPRINKLED OR NON - SPRINKLED' SHOW THE OCUPANT LOAD FOR THE S-2 AREA AND THE MEZZANINE PER FBC 1004.1.1 Comment: ENGINEER TO DESIGN A LIFE SAFETY PLAN ON PLANS PER F.F.P.C. / DO NOT USE DIAGONAL LINES' SEE 3/18/2015 7.6.1 ' USE THE ACCEPTABLE PATH METHOD FOR DESIGN • COMMON PATH OF TRAVEL CANNOT EXCEED 75' IN UN -SPRINKLED BUILDINGS Comment: SHOW THE DETAILS ON PLANS FOR THE SECOND MEANS OF EGRESS FROM THE MEZZANINE' THERE IS 3/18/2015 AN EXIT SHOWN ON PLANS W/ NO STAIRWAY' AT THIS TIME THERE IS A SECOND EXIT REQUIRED FROM THE MEZZANINE DUE TO THE TRAVEL DISTANCES Comment: ENGINEER TO SEE FBC 505 FOR MEZZANINE REQUIREMENTS •` MEZZANINES WITHIN A ROOM OR SPACE CANNOT EXCEED ONE-THIRD OF THAT SPACE [ F.B.C. 505.2 ] UNLESS BUILDING IS SPRINKLED AND IS OF 3/18/2015 TYPE I OR II CONSTRUCTION / SHEET 2 STATES 25' X 45' AND SCALES TO 33'6" ??? ALL PLANS MUST SCALE •** THE CLEAR CEILING HEIGHT CANNOT BE LESS THAN 7.0' A.F.F. Comment: FRED SHAEFFER TO DESIGN THE STRUCTURAL COLUMN BOLT EMBEDMENT DISTANCES INTO THE SLAB 3/19/2015 AND FOOTINGS FOR ALL REQUIRED LOADS OF THE BUILDING • THIS IS NOT CALCULATED ON SBS PLANS OR FRED SHAEFFER PLANS Comment: SHOW DIMENSIONS ABOVE FLOOR AND STAIRWAY FOR THE EXHAUST FAN AND SUBMIT PRODUCT 3/19/2015 APPROVAL FOR SAME' SEE F.B.C. 1609.1.2.1 REQUIRING THE EXTERIOR LOUVERS TO BE IMPACT RATED 3/19/2015 Comment: SUBMIT A SIGNED,SEALED AND DATED SOIL TEST IDENTIFYING THE SOIL PRESSURE TO BE 2500 P.S.F. Comment: ENGINEER TO SHOW THE ADDITIONAL FLOOR AND MEZZANINE LOADS REQUIRED PER FBC 1607.8.2 FOR 311912015 MOVING MACHINERY AND MOVING LOADS ON PLANS' DESIGN FLOOR SYSTEMS ACCORDINGLY Comment: THERE IS A COLUMN PAD MISSING ON THE FOUNDATION PLAN FOR COLUMN I AND OTHER PAD ON LEFT 3/19/2015 SIDE IS INCORRECT LOCATION Comment: DESIGN THE VEHICLE BARRIER LOADS ON PLANS FOR THE IMPACT LOADS PER FBC 1607.8 AND FBC 3/19/2015 TABLE 1607.1 Comment: SUBMIT IN TRIPLICATE THE PRODUCT APPROVAL WITH 1 HOUR FIRE TESTING FOR THE INTERNAL DCBI 3/19/2015 ROLL -UP DOOR AND 3068 SWING DOOR Comment: ENGINEER TO DESIGN THE WALL CUT AND INFILL DETAILS ON PLANS FOR THE EXISTING CBS / FRAME 312012015 WALL TO THE NEW ADDITION Comment: INCLUDE THE UL DETAIL ON PLANS [ 703 OR 804 ] FOR THE FIRE SPRAY ON THE WALL SECTION ABOVE 3/20/2015 THE C.B. WALL SECTION 3/20/2015 Comment: RE -SUBMIT ALL ORIGINAL PLANS IN TRIPLICATE WITH [ 2 ] PDF DISCS 3/20/2015 Comment: COMMENTS MAILED AND &MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 212512015 312/2015 31212015 Comment: Planning& Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(7721462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 3660 W Midway Rd City / State / Zip: Fort Pierce, FI 34981 Parcel #: 3403-502-0156-100/6 Zoning: APPLICATION INFORMATION Permit Number: 1502-0307 Permit Type: COMMERCIAL ADDITION REVIEW COMMENTS SCANNED BY St. Lucia County 1 Owner(s): Liberty Baptist Church Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: 92 Stories: CONTRACTOR INFORMATION Contractor Name: Paul Kuhn Jr Business Name: Heritage Contracting Services Inca RECEIVr,:. Business Addr: 3690 N Us 1 A City / State / Zip: Ft Pierce, FI 34946 APR REVIEWS AND COMMENTS Block: Automatic Sprinkler System? No Fax Number: Email: Paul.K.Hcs@Gmail.Com Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Audrey Humphrey 2120/2016 212012015 Comment: RECORDED NOTICE OF COMMENCEMENT 212012015 Comment: FILLED LANDS AFFIDAVIT 3/612015 Comment: VEG PERMIT FILED UNDER (L) FOR LIBERTY BAPTIST CHURCH - $50.00 FEE ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 3/5/2016 31512015 Comment: FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 2120/2015 212012015 2120/2015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 3/1812015 3/1812015 3/1812015 Comment: PLANS EXAMINER MECHANICAL VOIDED Carl Peterson Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 3118/2015 3/18/2015 Comment: PLEASE LIST OCCUPANT COUNT FOR EXISTING BUD AND NEW ADDITION ON PLANS 3/18/2015 Comment: PLEASE LIST HOW MANY EXISTING PLUMBING FIXTURES THERE ARE IN THE EXISITING BLD ON PLANS. Planning.& Development Services Building S, Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772]462-2172 Fax:(772)462.6443 REVIEW COMMENTS 2 PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 3118/2015 Comment: ALL DRAWINGS AND FINAL DOCUMENTS BEING FILED FOR PUBLIC RECORD AND PROVIDED TO THE 3/18/2015 OWNER MUST BE SIGNED, SEALED AND DATED IN ORIGINAL FORMAT [ SEE F.S. 471.025 ] THE PLANS FROM FREDERICK SHAEFFER AND GREGORY BARFIELD ARE NOT ORIGINALS' WE DO NOT ACCEPT ELECTRONIC SEALS AT THIS TIME OR PLAN COPIES Comment: WHEN COMPLETE THE BUIDING PLANS FROM SBS MUST BE MARKED REVIEWED AND APPROVED BY 3/18/2015 DESIGN PROFESSIONAL OF RECORD BEING FREDERICK SHAFFER • WE WILL NEED [ 3 ] SETS OF ORIGINAL S.S.D.FINAL DRAWINGS MARKED " FOR CONSTRUCTION " AT RE -SUBMITTAL 3/1812015 Comment: CERTIFICATION FOR DESIGN LOAD SHEETS ON SHEET 3 ARE INCOMPLETE' DESIGN PROFESSIONAL TO COMPLETE 2012 SUPPLEMENTS, ASO OR LRFD, END ZONE WIDTH, PSF DECK, STAIRS AND RAILINGS Comment: ENGINEER TO STATE THE CONSTRUCTION TYPE ON PLANS PER FBC 602.1 AND IF STRUCTURAL 3/1812015 ELEMENTS ARE PROTECTED OR UN -PROTECTED [A OR B ] — IS THE BUILDING SPRINKLED OR NON - SPRINKLED • SHOW THE OCUPANT LOAD FOR THE S-2 AREA AND THE MEZZANINE PER FBC 1004.1.1 • Comment: ENGINEER TO DESIGN A LIFE SAFETY PLAN ON PLANS PER F.F.P.C. / DO NOT USE DIAGONAL LINES' SEE 3/18/2016 a 7.6.1 ' USE THE ACCEPTABLE PATH METHOD FOR DESIGN • COMMON PATH OF TRAVEL CANNOT EXCEED 75' IN UN -SPRINKLED BUILDINGS (Comment: SHOW THE DETAILS ON PLANS FOR THE SECOND MEANS OF EGRESS FROM THE MEZZANINE' THERE IS 3/18/2015 AN EXIT SHOWN ON PLANS W/ NO STAIRWAY' AT THIS TIME THERE IS A SECOND EXIT REQUIRED FROM THE MEZZANINE DUE TO THE TRAVEL DISTANCES 'Comment: ENGINEER TO SEE FBC 505 FOR MEZZANINE REQUIREMENTS "MEZZANINES WITHIN A ROOM OR SPACE 3/18/2015� / CANNOT EXCEED ONE-THIRD OF THAT SPACE [ F.B.C. 505.2 ] UNLESS BUILDING IS SPRINKLED AND IS OF TYPE I OR It CONSTRUCTION / SHEET 2 STATES 25' X 45' AND SCALES TO 33'6" ?,?? ALL PLANS MUST SCALE •" THE CLEAR CEILING HEIGHT CANNOT BE LESS THAN TU A.F.F. Comment: FRED SHAEFFER TO DESIGN THE STRUCTURAL COLUMN BOLT EMBEDMENT DISTANCES INTO THE SLAB 3/1912015 AND FOOTINGS FOR ALL -REQUIRED LOADS OF THE BUILDING • THIS IS NOT CALCULATED ON SBS PLANS OR FRED SHAEFFER PLANS 3/19/2015 Comment: SHOW DIMENSIONS ABOVE FLOOR AND STAIRWAY FOR THE EXHAUST FAN AND SUBMIT PRODUCT APPROVAL FOR SAME' SEE F.B.C. 1609.1.2.1 REQUIRING THE EXTERIOR LOUVERS TO BE IMPACT RATED 3/19/2015 Comment: SUBMIT A SIGNED,SEALED AND DATED SOIL TEST IDENTIFYING THE SOIL PRESSURE TO BE 2500 P.S.F. 3/1912015 Comment: ENGINEER TO SHOW THE ADDITIONAL FLOOR AND MEZZANINE LOADS REQUIRED PER FBC 1607.8.2 FOR MOVING MACHINERY AND MOVING LOADS ON PLANS • DESIGN FLOOR SYSTEMS ACCORDINGLY 3/19/2016 Comment: THERE IS A COLUMN PAD MISSING ON THE FOUNDATION PLAN FOR COLUMN I AND OTHER PAD ON LEFT SIDE IS INCORRECT LOCATION 3/19/2015 Comment: DESIGN THE VEHICLE BARRIER LOADS ON PLANS FOR THE IMPACT LOADS PER FBC 1607.8 AND FBC TABLE 1607.1 3/19/2015 Comment: SUBMIT IN TRIPLICATE THE PRODUCT APPROVAL WITH 1 HOUR FIRE TESTING FOR THE INTERNAL DCBI ROLL -UP DOOR AND 3068 SWING DOOR 312012015 Comment: ENGINEER TO DESIGN THE WALL CUT AND INFILL DETAILS ON PLANS FOR THE EXISTING CBS / FRAME WALL TO THE NEW ADDITION 3/20/2015 Comment: INCLUDE THE UL DETAIL ON PLANS [ 703 OR 804 ] FOR THE FIRE SPRAY ON THE WALL SECTION ABOVE THE C.B. WALL SECTION 312012015 Comment: RE -SUBMIT ALL ORIGINAL PLANS IN TRIPLICATE WITH [ 21 PDF DISCS 3120/2015 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 2125/2015 3/212015 31212015 Comment: