PLANS REVIL ;HECK LIST— PUBLIC POOL —DOH / BOAF `: ion May 3 201
Date
Date Received LoQ#
Original N Revision_ Modification_
SP- File # i." .c+39G
Date Re-SVbmittal Received: Date of 2nd
- G:�IWsrL -
Items needing correction or clarification are marked by an "X" beside the appropriate section number of the Florida Administrative Code
citation (2009 64E-9, FAC, or 2010 FBC 424.1). We have left the 64E-9 requirements in this checklist because they are critical for public
health and therefore the pool will be checked for these items by the County Health Department at the first operating permit inspection after the
Building Official's approval of the construction.
Reviewer: Note that section 424.1.8.1 requires that "Spa pools shall meet the requirement of Sections 424.1.1 through 424.1.6.5, unless
specifically indicated otherwise." Use the additional "Spa pool" checklist for spa pools. This checklist can be used for Wading pools and there
is an additional Wading pool detail checklist.
From: www.myfloridaeh.com/water/swimAndex.htmi SCANNED
Florida Building Code or BY #sets plans _disk_
Florida Administrative Code
Section St. Lucie County
SwP Soa/WaP
64E-9.005(1)(a)3. _/— Plans review fees received as required by Section 64E-9.015
64E-9.005(1) (a)
64E-9.005(1) (a)
64E-9.005(1) (a)2.
64E-9.0050)(a)2.
424.1.2.1(a)
424.1.2.3.2
424.1.6.5.3.2.5
424.1.2.1 (b)
424.1.2.3.3 &.4
424.1.1
424.1.1
424.1.2.2.2
424.1.2.2.2
424.1.2.2.2
424.1.2.3.1 1.
424.1.2.3.1 1.
424.1.2.2.2
_/ Six one-piece applications for approval of swimming pool plans received.
Six sets of signed and sealed engineering plans received (proper size).
A 4" x 6" blank space exists on lower right h nd corner of plans sheets; site Ian is included.
An equipment list and specifications with manufacturer and/or distributor
names, model numbers, and catalog numbers included on plans.
Pool constructed of impervious structurally rigid material, light in color, with a smooth, non -toxic,
slip -resistant finish.
Pool shell free of designs which interfere with detection of human(s) in distress, algae, sediment,
or other objects in pool../
A min. 4" the line (6" for skimmer pools) is at the water line, max. 12" if dark tile. Gutter pools may
use 2" the line along pool wall edge of gutter lip. (tiles are min. 1" on all sides)
YA-
If 1" tiles are used in pool, adhesive is certified for shear strength (250 psi) & underwater use.
Lap lanes and targets on non -competition pools to meet code. (2-6" wide markings)
The filtration system is sized for at least 1 gpm per living unit for transient or 3/4 gpm per living unit
for non -transient. (For multiple pools: cumulative total GPM, excluding spas, wading pools and
interactive water features)
Conventional pool filtration system turnover period is not less than 3 hours unless otherwise
required. (For sizing purposes only.)
All pool walls (except steps and spa coves) have minimum 15' clearance perpendicular to a
tangent to the wall. (Interior step protrusion does not exceed 6')
_/ Corners shall be a minimum 90 degree angle.
Protruding corners to have at least 2" radius continued through top of gutter edge.
Coping does not overhang into the pool more than 1-112".
Pool water depth is at least 3' in shallow area.
Pool water depth is at least 4' in deep area.
The upper part of pool walls (areas of 5' or less depth) are within 50 of vertical for a minimum depth
of 21/2 and the radius joining this upper section to the floor does not exceed 2'/'.
424.1.2.2.2 _/ The upper part of pool walls in areas over 5' deep are within 5" of vertical for a minimum depth equal
to the pool depth minus 2'/2' and the radius joining this upper section to the floor does not
exceed 2Y2.
424.1.2.3.1 2. —/ Minimum 4" permanent contrasting depth markings, followed by the full or abbreviated words
"FEET' or "INCHES", properly located on both sides of the pool at shallow end, slope break,
deep end wall, and deep point. Horizontal surfaces are slip resistant.
424.1.2'3.1 2.
424.1.2.3.1 2.
424.1.2.3.1 3.
424.1.2.3.1 3.
424.1.2.3.1 4. N. /
424.1.2.3.14.
424.1.2.3.14.
424.1.2.3.1 5.
424.1.2.3.1 6.
424.1.2.3.1 6.
424.1.2.3.1 7.
424.1.2.3.1 7.
424.1.2.2.3.2
424.1.2.2.3.2
424.1.2.2.3.2
424.1.2.2.3.2
424.1.2.2.3
424.1.2.2.3.1
424.1.2.2.3.1
424.1.2.2.3.2
424.1.2.2.3.1
424.1.2.2.1
424.1.2.5
424.1.2.5.3
424.1.2.5.3
424.1.2.5.3
424.1.2.6.3
424.1.2.6.4
424.1.2.5.4
424.1.2.5.4
424.1.2.5.4
424.1.2.5.4
424.1.2.5.5
DdNSl markers shall indicate actual depth within 3 i s.
Symmetrical pool designs with deep point at center have dual markings indicating depth at wall
and at the deep point, followed by FEET or INCHES.
Maximum perimeter distance between depth markings is 25'.
Depth markings are visible from inside the pool and from the deck.
When curb is provided, depth markings are located on inside and outside riser. (Top of curb may be
substituted for outside riser location.)
When no curb is provided, depth markings are located at or above water level on inside vertical
wall and on the deck (within 2 of water edge).
When open type gutters are used, depth markers are located on the back of the gutter wall.
When deck level perimeter overflow systems are used, additional depth markers are on
adjacent fencing or walls, large enough to be recognizable from inside the pool. Depth markers on
deck are within 3' of water. Or, depth markers may be at top of pool wall just under water level.
In areas not part of an approved diving bowl, tile "NO DIVING" markings are on the curb top or deck
within 2' of water edge on each side of pool with a maximum distance between markings of 25'.
/ The "NO DIVING" markings are at least 4" high and contrasting; or a 6" the with min. 4" red
international "No Diving" symbol.
All markings installed on horizontal surfaces have a slip -resistant finish.
/ All markings are tile (unless pool is fiberglass, thermoplastic or stainless steel).
_/ Slope break (where applicable) has 5' depth or greater.
Slope break (if applicable) has 2-6" wide dark contrasting tile marking across bottom and up sides
at the transition point.
Slope break (if applicable) has safety line mounted with recessed cup anchors 2' before contrasting
marking, toward shallow end.
Safety line (if applicable) has visible floats at maximum 7' intervals.
Pool does not have double level floor.
The pool floor slope in areas of 5' depth or less does not exceed 1' in 10'.
The pool floor slope in areas of greater than 5' depth does not exceed 1' in 3'.
_/ The transition from a pool floor slope of 1' irr 10' to a greater floor slope has a slope break and
safety line.
The pool floor slope is at least V in 40'.
Diving areas meet minimum requirements of the FINA Handbook 2005-2009.
/ _!_
Adequate number of steps, swimouts, recessed treads and/or ladders provided (Every 75' of
perimeter, minimum of 2) including both ends (plus deep point, if not at one end).
Ppool
f deep end >30' wide, both sides have means of access.
Pool steps have not less than 24" tread length(s), 10" tread width(s) nor more than 10" tread riser(s).
Max. tread width is 48".
Intermediate step treads and risers are uniform in width and height (within 1/").
Dark, contrasting slip resistant tiles are provided for intersection of tread and riser for entire length
2"
of each step. (3/4" -2' on tread, on riser, or slip resistant bullnose)
Step and bench seat edge markings on vinyl liner and fiberglass pools are permanent,
permanently secured, dark, non -fading and slip resistant.
Swimouts extend 18" to 24" back from the pool wall and are 4' to 5' wide.
Unless stairs are provided the swimout is a maximum of 12" below the deck.
Swimout is located in an area of the pool with a depth exceeding 5'.
If pool is on skimmers, a wall inlet is provided within the swimout.
A dark, contrasting colored, slip resistant
tile band is located along the intersection of the pool wall
and the swimout, extending 2" on horizontal
and vertical surfaces. Bullnose tile may be
used with 3/4" on horizontal surface.
Handrail(s) for the stairs are correct length to mount in deck and bottom step (figure.four mounted in
424.1.2.5.5
424.1.2.5.6
424.1.2.5.1
424.1.2.5.1
424.1.2.5.2
424.1.2.5.2
424.1.2.6
424.1.2.6
424.1.2.6
424.1.3.1.3 &.2
424.1.3.1.1
424.1.3.1.2
424.1.3.1.2
424.1.3.1.4
424.1.3.1.5
424.1.3.1.5
424.1.2.6
424.1.2.6
424.1.3.1.8
424.1.3.1.6
424.1.3.1.6
424.1.3.2
424.1.3.2
424.1.3.2
424.1.6.5.3.1
424.1.6.5.3.1
424.1.6.6.3.1
424.1.6.5.3.1
424.1.6.5.3.1.3
424.1.6.5.3.1.1
/!rA
AV
YA
/c)
Y
A
KA
di:and extended over bottom step).
Handrails shall extend between 28" and 40" above me step or deck.
If provided, lifts to accommodate handicapped persons have a four foot wide deck behind the
lift mount.
Ladder(s) are cross -braced, corrosion resistant, are the correct length to mount in pool deck,
extend 28" to 40" above deck, and extend over into pool.
Ladder treads are slip -resistant and the clearance between the ladder and pool wall is 3 to 6".
Ladder bottom braces have end caps. Top rung is at or below water level on open gutter pools and
max. 12" below deck/curb top on all others.
Step treads installed into pool wall shall be flush with pool wall and have minimum 5" tread width,
minimum 10" length, & a maximum vertical distance of 12" between steps.
Step treads installed into pool wall have a grabrail at each side of the steps and each grabrail is
mounted in the deck and extends 28" to 40' above the deck.
Underwater bench seats are 14" to 18" wide and have a 2" wide dark contrasting slip resistant
tile marking along the horizontal and vertical surface. Slip resistant bullnose tile may be used
with W on horizontal surface.
Underwater bench seats are in areas less than five feet deep.
Benches do not protrude into the 15' clearance requirement.
Pool deck has unobstructed area with minimum 4' width around Perimeter of pool, handrail
& ladder anchors, diving boards/towers, and slides. Pits and crevices more than 3/16" deep not
allowed.
_/ Pool deck constructed of impervious material with slip -resistant finish.
_/ Pool deck is not below maximum 10" from the curb top when curb is provided.
Indoor and outdoor pool deck has a minimum 2% and maximum 4% uniform slope away from pool
or to deck drains.
Traffic barriers provided to prevent obstruction of deck by vehicles (where applicable).
Hose bibb with vacuum breaker is provided to wash deck with potable water.
/_ Walkways between the pool and sanitary facilities are constructed of concrete or other
non -absorbent materials for the first 15' of walkway and have a slip -resistant finish.
Pool water area has no obstruction.
Structures located inside pool perimeter are additional part of the recirculation system and are not
located less than 15' from any pool wall and are not located within the diving bowl area.
The vertical clearance above the pool deck is at least 7'.
Obstructions of the perimeter of the pool do not exceed 10% of total pool perimeter, and are
protected by a barrier or designed to discourage patron access.
Obstructions of the perimeter of the pool have a wet deck area behind or through the obstruction
and within 15'of the water edge. Approved slides have the near edge of walk within 35' of water.
Bridge or obstruction over pool is at least 8' above pool bottom and at least 4' above water surface.
Minimum 42" high handrails are provided along each side of the bridge.
Bridge or walkway footing surface is constructed of concrete or other non -absorbent material
having a smooth slip -resistant finish.
Pool has perimeter overflow gutter or recessed automatic surface skimmers (where
allowed).
Overflow gutter lip is Ievel(max.%" between high & low) and bottom of gutter is level or
slopes to gutter drains.
The gutter drain spacing does not exceed 10' for 2" drains or 15' for 2'/" drains.
Gutters may be eliminated for no more than 15' of pool perimeter (or max.10% of perimeter). In such
areas, handholds shall be installed within 9 inches of water surface.
_/ Gutter lip has min. 2" of tile on pool wall (except if stainless steel). (tiles are min. 1" on all sides)
_/ Recessed gutter is at least 4" deep and 4" wide with no part of the gutter trough visible from a
point directly above.
3
424.1.6.5.3.1.1 _/ Open Type gutter is at least 6" deep and 12" wide with (f %;') slope from the lip to the gutter
NX drain level (may be 1" at steps if gutter used as treao) and back wall is smooth glazed tile.
424.1.6.5.3.1.1 �D /_ Back of gutter drain is within 3/4" of back vertical wall of gutter wall where gutter is deepest,
,��� and flush or recessed no more than 3/8".
424.1.6.5.3 A _/_Gutter drain system is capable of handling 100% of the recirculation flow and shall discharge
/ into the collector tank.
424.1.6.5.3.2 _V/
424.1.6.5.1
424.1.6.5.3.2.1
424.1.6.5.3.2.1 G _/
_/ Skimmer pool water surface area does not exceed 1000 ft' (excluding offset stairs & swimout) and
does not exceed maximum width of 20' (when measured perpendicular to a tangent to the wall).
_/ Skimmers have NSF approval.
_/ Skimmer system designed to carry 60% of pool total design flow rate with each skimmer carrying
at least 30 gpm.
!_ Number of skimmers is based upon 1 for every 400 ft.' or fraction thereof of pool water surface area.
424.1.6.5.3.2.2
Skimmers are located to take advantage of prevailing wind direction and to minimize interference
from adjacent inlets or skimmers.
424.1.6.5.3.2.2
/ Skimmers do not protrude into pool area.
424.1.6.5.3.2.2
H /_ Pools with skimmers have handhold in deck or curb construction which is not more than 9" above
midpoint of skimmer.
424.1.6.5.3.2.3
Skimmer installation may be installed with spring loaded vertical check equalizer valve and 2" min.
_/
diameter equalizer line, installed at least 12 " below normal water level protected by an ASME/ANSI
At 12.19.8-2007 compliant grate, when skimmer system is connected to pump suction. No float
0 k valves allowed.
424.1.6.5.3.2.4
_/ A wall inlet fitting is directly across from each skimmer.
424.1.6.5.11
_/ Pool makeup water supply is from an approved potable water system or meets those requirements
with bacteriological/chemical reports to county health department.
424.1.6.5.11
�/ Pool makeup water supply has air break or approved backflow prevention device.
424.1.6.1.48
✓ / Hose bibbs have vacuum breakers.
424.1.3.1.5
--
424.1.6.5.2
_/_ The recirculation/filtration equipment is designed to provide at least(4 urnovers of the pool volume
per day. Health or fitness centers shall provide 8 turnovers per day un ess pool is 1000 ft' or larger.
424.1.6.5.3
y4 !_ The design pattern of recirculation flow of pool with overflow gutters is
100% through main drain piping and 100% through gutter system piping.
424.1.6.5.3
V_/_ The design pattern of recirculation flow for pool with skimmers is 100% through
main drain and 60% through skimmer system piping.
424.1.6.10.5
_/ A collector tank with an effective capacity of at least 1 minute of the design flow is provided.
424.1.6.5.11
✓ An automatic water makeup control and a manual pool fillspout are provided to
_/_
discharge into the collector tank with an air gap.
/
424A.6.5.4
V _/_ The recirculation pump is sized at the proper T.D.H. according to the type of filter system.
424.1.6.5.4
_/_ The recirculation pump (when mounted above the water level of the pool) is specified as self -priming.
64E-9.007(17)
~ _/_ Waterfalls or features: Return piping is capable of handling additional feature flow when feature
turned off. Feature requiring more than 20% of flow rate has additional pump that drafts from
a suitable collector tank. Feature water is not counted toward designed turnover rate.
Water from the features returns to the pool.
64E-9.007(17)
' / Spray features mounted in deck are flush with pool deck.
424.1.6.5.9.6
/ /_ The number of inlets handle the recirculation flow with a maximum flow of 20 gpm per inlet.
424.1.6.5.9
(_ Wall return inlets are directionally adjustable and do not protrude into the pool.
Wall inlets are a min. of 12" below normal water level unless otherwise justified.
424.1.6.5.9.1
_/ Pools 30' or less wide, with wall inlets only, have maximum spacing of 20' between inlets
based on pool perimeter.
424.1.6.5.9.2
_/ Pools 30' or less wide, with floor inlets only, have inlets located such that they are not over 20' apart
nor over 10' from adjacent walls.
424.1.6.5.9.3
P. ,j.. 30' or less wide with combination floor and w ets meet requirements of
_/
either 424.1.6.5.9.1 or .2.
Al,
424.1.6.5.9.4
Pools greater that 30' wide have floor inlets only or a combination of floor and wall inlets.
424.1.6.5.9.4
Pools greater than 30' wide, with floor inlets only, have inlets located such that they are not over
_/
20' apart or 10' from adjacent walls.
424.1.6.5.9.5
7dl Pools greaterthan 30' wide with combination floor and wall inlets have wall inlets not over 20' apart
_/
(based on pool perimeter) and floor inlets are provided for the water area beyond 15' perpendicular
distance from all walls. (Floor inlets are located not over 20' apart and 25' from adjacent walls.)
424.1.6.5.9
N
_/ Floor return inlets have a means of flow adjustment.
424.1.6.5.9
/ Floor inlets do not protrude above pool floor and do not have sharp edges or protrusions. For
vinyl liner & fiberglass pools, floor inlets are not more than 3/8" above floor.
424.1.6.5.10
The main drain grate(s) are located at the deepest point in the pool and are flat, flush, and
_/
not readily breakable or removable by bathers.
424.1.6.5.10.1
_/ The depth at the deepest pointimain drain grate does not deviate more than 3" from side wall depth
indicated by depth markers at the location. (unless dual marking used)
424.1.6.5.10.2
_/_ The open area of the main drain grate(s) is such that the flow velocity at the grate(s) does not
exceed 1'/2' per second at the design flow rate of the recirculation pump.
424.1.6.5.10.3
14JA _/ Pool over 30' wide in deep end has multiple main drain grates, equally spaced from the pool
side walls and each other.
424.1.6.5.10.4
�A _/ Hydrostatic relief devices have been provided if high ground water exists at site.
424.1.6.5.4
If the recirculation pump takes suction prior to filtration, the pump is specified with hair and
_/_
lint strainer.
/
424.1.6.5.12
✓ _/ A portable or plumbed vacuuming system is provided which allows vacuuming the pool with a hose
not more than 50' in length. Recirculation pump over 3 hp is not used for vacuuming.
424.1.6.5.12
_/ Vacuum cleaning system pump is provided with hair and lint strainer.
424.1.6.5.12
/ A vacuum fitting with spring -loaded safety cover, is flush mounted no more than 15" below water
level. (12" acceptable in FBC, 15" max. per 64E-9.007(12).
424.1.6.5.12
Bag type cleaners that operate as ejectors on potable water supply pressure
_/_
are protected by a vacuum breaker.
/
424.1.6.5.13
V /_ A flowmeter capable of reading at least 1112 times the design flow rate is properly located with
proper clearances upstream and downstream. (Located in the pump discharge line
for sand filter systems and in the pool return line for other filter systems.)
424.1.6.5.14�
/_ If heater is provided, a fixed thermometer is mounted in the pool recirculation line
downstream of the heater outlet line connection.
�
424.1.6.5.14
/_ Sufficient valves and piping are provided to allow isolation or removal of the pool heater.
424.1.6.5.14NS}n
/_ Heater bypass valve is designed for proportioning flow (gate valve is unacceptable).
424.1.6.5.14
/_ Material used in solar and other heaters are non -toxic and acceptable for potable water use.
424.1.6.5.6
V _/_' Plastic pipe has NSF- pw seal of approvtal and is completely specified.. .
424.1.6.5.6
_/_ Plastic pipe exposed to sunlight is coated for UV protection.
424.1.6.5.7
V _/_ Return line, main drain line, and surface overflow system lines each have proportioning valves.
424.1.6.5.8
_/ All pressure piping is sized such that the flow velocity does not exceed 10' per second at the
design flow rate. (Exception for precoat lines when higher velocity is needed for agitation purposes.)
424.1.6.5.8
_/ All suction piping is sized such that the flow velocity does not exceed 6' per second at the design
flow rate. (Exception is vacuum filter header assembly where velocity may be up to 10' per second.)
424.1.6.6.8
_/_ Main drain systems and surface overflow systems which discharge to collector tanks are sized
such that the flow velocity does not exceed 3' per second at the design pattern of recirculation flow.
424.1.6.5.15�
_/ Each waste line has a unique air gap and is not connected to other lines. Method of water
& DE powder disposal is acceptable.
A
424.1.6.5.5.1
_/_ 5� a"'nrd4ilters: The filter is sized such that the filtratir to does not exceed 3 gpm/ft2 for rapid
and filter or 15 gpm/ft2 for high rate sand filters (or 20 if so rated by NSF).
424.1.6.5.1/diameter(s)
and filters meet the requirements of NSF/ANSI Standard 50 - 2007.
64E-9.007(8)and
filters: The recirculation pump(s) and piping is designed to be capable of backwashing.
424.1.6.5.4and
filters: The recirculation pump provides a min. T.D.H. of 60'for filtration unless hydraulically
ustified by the design engineer.
424.1.6.5.5.2.1and
filters: Pressure filters have influent and effluent pressure gauges with minimum 2" face
and scale(s) of 0-60 psi and a sight glass in the backwash line.
424.1.6.5.5.2.1and
filters: The pressure filter tanks have air relief valves.
424.1.6.5.6.2.2and
filters: Vacuum filter has 2", or larger, diameter vacuum gauge in suction line with 0-30"
mercury) scale.
64E-9.007(8)
_/ Sand filters: Piping system permits filtering to pool, vacuuming to filter, vacuuming to waste,
backwashing individual filters, complete drainage of the system, and space to allow maintenance.
424.1.6.5.6.1
_/_ jD E.-Type filters: The filter is sized such that the filtration rate does not exceed 2 gpm/ft'.
424.1.6.5.5.2.3
_/_ If diatomaceous earth type filters are used, separation devices are provided and properly sized
424.1.6.5.1
for the waste water system.
/✓EED
_/ D. peTilter3` Components and materials have been tested and approved using
NSF/ANSI Standard 50-2007.
424.1.6.5.5.2.3
_/_ D.E. type filters: Pressure filter(s) have precoat pot or collector tank for precoating purposes.
64E-9.007(8)
!_ D.E. type filters: Pressure filter(s) have piping to backwash to waste by reverse flow procedure
and filter can be completely drained.
64E-9.007(5)(c)
_/_ Custom design filter meets the requirements of 64E-9.007(5)(c).
424.1.6.5.5.3
_/ D.E. type filters: The filter area is determined on the basis of effective filtering surfaces with no
allowance given for areas of impaired filtration.
424.1.6.6.5.3
! D.E. type filters: Filter septa have a minimum 1" clear spacing between elements (up to 4 it' effective
area per septum) and the minimum spacing between elements is 1/8" larger for each additional
square foot or fraction thereof of septum area over 4 ft'.
424.1.6.5.4
_/ D.E. type filters: The recirculation pump provides 60' T.D.H. for pressure systems and 50' T.D.H.
for vacuum systems.
424.1.6.5.5.2.1
_/ D.E. type filters: Pressure filter(s) are equipped with air relief valves, influentleffluent pressure
gauges (2" minimum face diameter), and a sight glass in the waste line.
424.1.6.5.5.2.2
/_ D.E. type filters: Vacuum filter has vacuum gauge with minimum face diameter of 2", reading 0-30"
of mercury located on suction line.
424.1.6.5.5.3
_/ D.E. type filters: Vacuum filter tank has coved intersections between the wall and the floor and the
tank floor slopes to the filter tank drain.
64E-9.007(8)
/_ D.E. type filters: The system allows filtering to pool, precoat recirculation to filter, vacuuming to
waste, vacuuming to filter, backwashing (pressure filter) to waste, and complete drainage of filter
tank.
424.1.6.5.5.1
_/ �C rtra idg'e fifer s: The filter complies with the maximum filtration rate of 0.375 gpm/ft' for pleated
ridges.
424.1.6.5.1
filters: The filter model has met the requirements of NSF/ANSI Standard 50-2007.
424.1.6.5.4
filters: The recirculation pump is selected to give 60'T.D.H.
/influentleffluent
424.1.6.5.5.2.1
filters: Pressure type filter(s) are self -purging or have air relief valves and have
pressure gauges with minimum 2" face diameters and reading 0-60 psi.
424.1.6.5.5.2.2
filters: Vacuum filter has vacuum gauge with 2" minimum face
di, Lr (0-30" mercury reading) located on the su I line
64E-9.007(81 /— Cartridge filters: Filter system is capable of filtering to pool, vacuuming to waste, vacuuming to
filter, and complete drainage of the filter tank with space for maintenance.
64E-9.007(5)(c) —1— Cartridge filters: The filter cartridges are permanently marked with the
manufacturers name, pore size, and filter area on one end cap.
424.1.6.5.16.2 —/ Hypohalogenation: The feeder has adjustable feed rate from zero to full range
and meets the requirements of NSF/ANSI Standard 50-2007.
424.1.6.5.16.2 —/— Hypohalogenation: The feeder is capable of feeding a dosage of 6 ppm to the minimum required
turnover flow rate (if solution type feeders, a 5% calcium hypochlorite or 10% sodium hypochlorite
solution).
424.1.6.5.16.2 —/ Hypohalogenation: An electrical feeder, when used, has electrical interlock
with the recirculation pump. A flow sensor controller may be used.
424.1.6.5.16.2 —/— Hypohalogenation: Solution crock has a volume equal to at least 50% of the
maximum daily feed capacity of the chlorine solution feeder.
424.1.6.5.16.2 T% —/— Hypohalogenation: Solution crock is marked to indicate contents.
424.1.6.5.16.2 —/— Erosion type feeder shall have a flowmeter and flow adjustment valve.
424.1.6.5.16.3 /— pH adjustment feeder: A positive displacement type feeder adjustable from
zero to full range & meets NSF/ANSI Standard 50-2007 is provided.
424.1.6.5.16.3 ✓
/— pH adjustment feeder: An electrical feeder has electrical interlock with the recirculation pump.
424.1.6.5.16.3
/— pH adjustment feeder: The solution crock volume is at least 50% of the maximum
daily capacity of the feeder and is marked to indicate the contents.
64E-9.004(11)
/— A test kit is provided and is capable of testing for free active halogens,
_161/
total or combined available chlorine, total alkalinity, calcium hardness & pH.
64E-9.0040 1) (a) ~4
/— If a cyanurate type feeder is used, a cyanuric acid test kit is provided.
64E-9.004(11)(a) 'V
—/— If a salt solution in the pool water is necessary for a chlorine generator, a sodium chloride test kit
is provided.
424.1.5.1
/— An equipment room or enclosure is provided which is protected from unauthorized entrance
and from the weather on 3 sides and overhead. Equipment designated by manufacturer for
outdoor use may be located in a 4' min. fenced equipment area with self -closing, self -latching
gate with locking device.
424.1.3.1.9
A gate through the pool fence from the pool area to the equipment area is provided within 10 feet of
/
the equipment area is provided
424.1.5.3 V
—/— The equipment room floor is constructed of concrete or other nonabsorbent material having a
smooth slip -resistant finish and uniformly sloped to prevent standing water.
424.1.5.4
424.1.5.4
424.1.5.5
424.1.5.9
424.1.5.6
424.1.5.6
424.1.5.7
64E-9.006(2)(e)
424.1.4.2
424.1.4.2.1
-! The equipment room has forced draft, or adequate cross ventilation, and positive floor drainage
with sump pump if needed.
Below grade equipment rooms have a stairway with forced draft ventilation or fully louvered door
and powered intake within 6" of floor. Ship's ladder may be specified by design engineer.
i-yr`0
The equipment room access is at least Tx 6'.
The equipment room is provided with a hose bibb with vacuum breaker.
The equipment room size and layout provides clearances for all equipment as
prescribed by the manufacturer to allow normal maintenance and removal.
The equipment room with a fixed ceiling has a minimum height of 7'.
The equipment room is lighted to provide a minimum 30 fc of illumination at floor level.
Collector tank or filter tank (vacuum system) is not accessible to unauthorized individuals.
Lighting: Artificial lighting is provided when natural lighting is not adequate or when night
swimming will be allowed.
Outdoor pool lighting: if night swimming is to be allowed, lighting will provide at least 3 fc
7
of iination at the water and wet deck level.
424.1.4.2.1 d _/_ Outdoor pool lighting: If night swimming is to be allowed, underwater lighting will provide
at least 1/2 watt per square foot of pool water surface area.
(Except where above water lighting is at least 15 fc of illumination.)
424.1.4.2.2 �} /_ Indoor pool lighting: If natural illumination is inadequate, or night swimming is to be allowed,
lighting shall provide at least 10 fc of illumination at the water and wet deck level.
424.1.4.2.2 NIA / Indoor pool lighting: If natural illumination is inadequate or night swimming is to be allowed,
underwater lighting will provide 0.8 watt per square foot of water surface area. (Except where
above water level lighting is at least 15 fc of illumination.)
424.1.4.2.3 _/_ Lighting: The underwater lighting utilizes transformers and low voltage circuits (15 volts maximum)
with each underwater light grounded. (When dependent upon submersion for safe operation,
lights have protection from overheating when not submerged.)
424.1.4.2.3 _/_ Lighting: The underwater incandescent lamp size does not exceed 300 watts and is located
/ at least 18" below normal water level. (center line of skimmer, or top lip of gutter)
424.1.4.2.4 V _/_ Lighting: The plans do not show overhead service wiring within 10' horizontally of the pool walls or
deck appurtenances; or clearances meet NEC standards:
424.1.4.1 _/_ The electrical equipment wiring and installation will conform to the Chapter 27, of the Florida Building
/ Code, Building.
424.1.1 ✓ / Bathing load: If the pool is not a spa pool, the bathing load is computed on the basis of 1 person
per each 5 gpm of water recirculated.
424.1.1 NA _/_ If the pool is a spa, the bathing load is computed on the basis of 1 person per each 10 ft2 of
water surface area.
64E-9.008(7)� _/ The bathing load will be posted at the pool as required in the bathing rules.
424.1.6.1 _/ If bathing load is less than 40, Separate sanitary facilities for each sex are provided, entrances
Are labeled for men or women, and entry doors are within 200' walking distance of the nearest
/ water's edge for each pool.
424.1.6.1.1 V _/_ Fixtures are provided as indicated on the following chart: (suitable for deck area up to 3x pool
surface)
Men's Restroom Women's Restroom
Size Urinals WC Lavatory Size WC Lavatory
0-2500 ft' 1 9 170-2500 ft2 1 1
2501-5000 ft2 2 1 1 2501-5000 ft2 5 1
5001-7500ft' 2 2 2 5001-7500ft2 6 2
f7500,000 ft' 3 2 3 7501-10,000 ft2 8 3
424.1.6.1.1 _/ Supplemental family -style restrooms may be used to meet requirements.
424.1.6.1 / Unisex restrooms: may be used if bathing load is 20 or less (1), or 40 or less (2).
Each has a water closet, a urinal, a lavatory and a diaper changing table.
424.1.6.1 _/ Pools greater than 10,000 ft2 have one additional fixture set for each 7,500 ft2 or major fraction
424.1.6.2 / Sanitary facilities for outdoor pool have outside access door. If in adjacent building,
doors are within 50' of the exterior door.
424.1.6.1 _/_ Sanitary facilities are not required if all units served by the pool are within a 200' horizontal radius
exception from the nearest pool water edge, are not over 3 stories high, unless served by elevator, and have
/ private sanitary facilities.
424.1.6.1.3 V _/ Sanitary facilities' floors are to be constructed of concrete or other impervious material and have a
/ smooth, slip -resistant finish.
424.1.6.1.3 ✓ /_ Sanitary facilities' floors are sloped for positive drainage to drains.
424.1.6.1.3 / Intersections between floors and walls are coved if either floor or wall isn't waterproof material.
424.1.6.1.3 ✓ Sanitary facilities: There are no foot baths, carpet or duck boards on the floor.
424.1.6.1.4 ✓/ / A hose bibb with vacuum breaker is in or within 25' each restroom for ease of cleaning.
424.1.6.1.2 _! Sanitary facilities: Where separate non -private sanitary facilities are provided and are not visible
from any portion of the pool deck, signs are posted showing directions to the facilities.
Signs are legible from the pool deck, with letters at least 1" high.
y
424.1.6.1.1 ® _/
0 ,.aper changing table is provided at each resh, unless all pools restricted to adult use.
424.1.6.2 /
If the pool is outdoors, a rinse shower is provided on the pool deck and is located within 20' of
the pool water edge.
64E-9.008(2) ¢ _/
If the pool length is 50' or less, at least 1 shepherd's hook with one-piece pole (minimum 16' long)
and 1 lifesaving ring (minimum 18" in diameter) with sufficient rope attached to reach all parts
of the pool from the deck are provided, mounted in a conspicuous place.
64E-9.008(2) _/
If the pool length is greater than 50' there are multiple shepherd's hooks with one-piece poles
(min. 16' long) and multiple lifesaving rings (min. 18" diameter) with sufficient ropes attached to
reach all parts of the pool from the deck, mounted along each of the longer sides of the pool.
64E-9.006(1)(e) _/_
There are no protrusions, extensions, means of entanglement, or other obstructions on the pool
floor or pool walls.
If solar blanket or pool cover is specified, it is either secured around entire pool perimeter and
/% �E
4
can support a live load of an adult person, or the pool area can be made inaccessible to
unauthorized persons when cover is in use.
424.1.3.1.9
Pool is surrounded by min. 48" high fence with self -closing, self -latching, lockable gates opening
_✓ _/_
away from pool. Latch is 54" above bottom of gate or min. 3" below the top of the gate on the pool
side. Fence does not allow passage of 4" diameter sphere. Locks, if self-locking, may be 34 - 48"
above floor or ground.
424.1.3.1.9/_
Access through the fence from dwelling units is via minimum 48" self -closing, self -latching, lockable
gate. Doored access from public rooms need not be through gates.
424.1.3.1.9 /_
Other substantial barriers may be considered by the department.
424.1.3.1.9 _/_
Screened pool enclosures are hardened on the bottom 3 feet.
424.1.5.8 /_
Provision is made for storage of chemicals in well -ventilated area: 64E-9.008(5) adds: under roof
and protected from access by unauthorized. persons.
64E-9.008(6) _/_
Swimming pool slide is installed in accordance with the manufacturer's specification.
424.1.6.5.11 /_
Over the rim fill spout prohibited.
64E-9.008(7)/_
The following rules will be posted at or near poolside and will be legible from pool deck:
1. No food or beverages in pool or on wet deck.
2. No glass or animals within fenced pool area (or 50' from unfenced pool ).
3. Bathing Load:_persons.
4. Pool Hours: A.M. to P.M.
5. Shower before entering pool.
6. Do not swallow the pool water.
64E-9.008(7) _/_
The lettering for the pool rules sign is at least 1" high.
64E-9.008(7) _/
Pool over 200 ft' without an approved diving bowl configuration has "NO DIVING"
/
included on the pool rules in lettering at least 4" high.
424.1.3.1.7 ✓ _/
There is no provision for drink or food serving facilities within 12' of the waters edge.