REVIEWS AND COMMENTS
REVIEW COMMENTS
oGANNE®
BY
I irle County
1
Owner(s):
Tarpon Flats Llc
Jurisdiction: SAINT LUCIE COUNTY
Lot#: Block: 1
Stories: Automatic Sprinkler System? No
Fax Number: 772-467-1624
Email: Tmcghee@Angpools.Com
Review Tyne
Status Reviewed By Date Started Dale Completed Date Released
DOCUMENTS MISSING
PENDING Deanna Givens 212712015
2/27/2015 Comment:
NOTICE OF COMMENCEMENT
2/27/2015 Comment:
CUSTOMER WILL BRING VEG PERMIT TO ERD
3/5115 VEG.PERMIT WAS IN FILE. DROPPED IT OF AT ERD. L.GALBRAITH.
3130/2015 Comment:
VEGETATION REMOVAL IN DRAWER UNDER (T) FEE IS LOADED
ENVIRONMENTAL REVIEW
COMPLETE Ben Balcer 312612015 3/2612015
Comment:
FRONT COUNTER REVIEW
COMPLETE Deanna Givens 2/27/2015 2127/2015 2/27/2015
Comment:
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride 3/2712015 3/2712015 312712015
Comment:
PLANS EXAMINER PLUMBING
PENDING Greg Smyth
Comment:
PLANS EXAMINER REVIEW
INCOMPLETE Joe Cicio 3/2612015
Comment:
SITE PLAN MUST INCLUDE THE 4" X 6" BLANK SPACE ON THE LOWER RIGHT HAND CORNER ( SAME AS
3/26/2015
PLANS ] 64E-9.005 (1) (A)2
Comment:
SHOW THE TIE DOWNS ON PLANS FOR THE POOL EQUIPMENT SHELTER AND HEATER' SHOW THE
3/2612015
ON/OFF SWITCH FOR THE POOL HEATER FBCE 504.7.1
3/26/2015 Comment:
SUBMIT A SEPARATE PERMIT FOR THE GAS POOL HEATING SYSTEM
�'�aurio �oc:sx��s
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone;(772)462-2172 Fax:(772)462.6443
REVIEW COMMENTS
2
3/2612015
Comment:
SUBMIT THE MANUFACTURERS PERFORMANCE CRITERIA FOR THE POOL HEATER' FBCE 504.7.1
3/2612015
Comment:
SUBMIT THE MANUFACTURERS SPECIFICATIONS FOR THE POOL COVER' FBCE 504.7.3
3/26/2015
Comment:
CHANGE THE PERMIT APPLICATION TO STATE THE CORRECT ENGINEER OF RECORD
3/27/2015
Comment:
POOL DECK MUST BE CONSTRUCTED OF IMPERVIOUS MATERIAL WITH SLIP RESISTANT FINISH . FBC
424.1.3.1 ' SUBMIT THE MANUFACTURERS SPECIFICATIONS FOR THE STATED IMPERVIOUS PAVERS
3/27/2015
Comment:
WALKWAYS SHALL BE PROVIDED BETWEEN THE POOL AND SANITARY FACILITIES ARE OF CONCRETE OR
OTHER NON ABSORBENT MATERIALS [ 15' MEASURED FROM THE WATERS EDGE ] SEE FBC 424.1.3.1.5
3/27/2015
Comment:
SHOW THE MIN VERTICAL CLEARANCE ABOVE THE POOL DECK' FBC 424.1.3.1.8
3/27/2015
Comment:
IDENTIFY THE REQUIRED DIAPER CHANGING TABLES IN EACH RESTROOM ON PLAN SHEET 1 OF 5' FBC
424.1.6.1.1
3/27/2015
Comment:
SHOW THE LOCATION OF THE VENTILATED AREA ON PLANS AS TO WHERE THE POOL CHEMICALS WILL
BE STORED' FBC 424.1.5.8
3/31/2015
Comment:
PLEASE SUBMIT THE MANUFACTURERS SPECIFICATIONS FOR THE AQUAWORKS D.E. FILTER FOR
REVIEW' CANNOT LOCATE MODEL NUMBER ON LINE
3/31/2015
Comment:
COMMENTS MAILED AND E-MAILED AS OF THIS DATE
ZONING REVIEW
COMPLETE Lydia Galbraith 3/512015 3/512015 3/512015
Comment: