Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning 8 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34992 Phone:(772)462-2172-Fax:V72)46Z6443 PROPERTY INFORMATION Address: 951 Tarpon Flats Dr. City / State / Zip: Fort Pierce, FI 34949 Parcel#: 1423-566-0001-000/8 Zoning: HIRD APPLICATION INFORMATION Permit Number: 1502-0396 Permit Type: POOL/SPA - COMMERCIAL CONTRACTOR INFORMATION Contractor Name: James T Leonard Business Name: A & G Concrete Pools Inc Business Addr: 410 Saeger Ave City / State / Zip: Ft Pierce, FI 34982 REVIEWS AND COMMENTS REVIEW COMMENTS oGANNE® BY I irle County 1 Owner(s): Tarpon Flats Llc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: 1 Stories: Automatic Sprinkler System? No Fax Number: 772-467-1624 Email: Tmcghee@Angpools.Com Review Tyne Status Reviewed By Date Started Dale Completed Date Released DOCUMENTS MISSING PENDING Deanna Givens 212712015 2/27/2015 Comment: NOTICE OF COMMENCEMENT 2/27/2015 Comment: CUSTOMER WILL BRING VEG PERMIT TO ERD 3/5115 VEG.PERMIT WAS IN FILE. DROPPED IT OF AT ERD. L.GALBRAITH. 3130/2015 Comment: VEGETATION REMOVAL IN DRAWER UNDER (T) FEE IS LOADED ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 312612015 3/2612015 Comment: FRONT COUNTER REVIEW COMPLETE Deanna Givens 2/27/2015 2127/2015 2/27/2015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 3/2712015 3/2712015 312712015 Comment: PLANS EXAMINER PLUMBING PENDING Greg Smyth Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 3/2612015 Comment: SITE PLAN MUST INCLUDE THE 4" X 6" BLANK SPACE ON THE LOWER RIGHT HAND CORNER ( SAME AS 3/26/2015 PLANS ] 64E-9.005 (1) (A)2 Comment: SHOW THE TIE DOWNS ON PLANS FOR THE POOL EQUIPMENT SHELTER AND HEATER' SHOW THE 3/2612015 ON/OFF SWITCH FOR THE POOL HEATER FBCE 504.7.1 3/26/2015 Comment: SUBMIT A SEPARATE PERMIT FOR THE GAS POOL HEATING SYSTEM �'�aurio �oc:sx��s Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone;(772)462-2172 Fax:(772)462.6443 REVIEW COMMENTS 2 3/2612015 Comment: SUBMIT THE MANUFACTURERS PERFORMANCE CRITERIA FOR THE POOL HEATER' FBCE 504.7.1 3/2612015 Comment: SUBMIT THE MANUFACTURERS SPECIFICATIONS FOR THE POOL COVER' FBCE 504.7.3 3/26/2015 Comment: CHANGE THE PERMIT APPLICATION TO STATE THE CORRECT ENGINEER OF RECORD 3/27/2015 Comment: POOL DECK MUST BE CONSTRUCTED OF IMPERVIOUS MATERIAL WITH SLIP RESISTANT FINISH . FBC 424.1.3.1 ' SUBMIT THE MANUFACTURERS SPECIFICATIONS FOR THE STATED IMPERVIOUS PAVERS 3/27/2015 Comment: WALKWAYS SHALL BE PROVIDED BETWEEN THE POOL AND SANITARY FACILITIES ARE OF CONCRETE OR OTHER NON ABSORBENT MATERIALS [ 15' MEASURED FROM THE WATERS EDGE ] SEE FBC 424.1.3.1.5 3/27/2015 Comment: SHOW THE MIN VERTICAL CLEARANCE ABOVE THE POOL DECK' FBC 424.1.3.1.8 3/27/2015 Comment: IDENTIFY THE REQUIRED DIAPER CHANGING TABLES IN EACH RESTROOM ON PLAN SHEET 1 OF 5' FBC 424.1.6.1.1 3/27/2015 Comment: SHOW THE LOCATION OF THE VENTILATED AREA ON PLANS AS TO WHERE THE POOL CHEMICALS WILL BE STORED' FBC 424.1.5.8 3/31/2015 Comment: PLEASE SUBMIT THE MANUFACTURERS SPECIFICATIONS FOR THE AQUAWORKS D.E. FILTER FOR REVIEW' CANNOT LOCATE MODEL NUMBER ON LINE 3/31/2015 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 3/512015 3/512015 3/512015 Comment: