Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning 6 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(7721462-2172 Fax:(7721462-6443 PROPERTY/NFORMATION Address: 8537-8545 S Us Hwy 1 City I State I Zip: Port St. Lucie, FI 34952 Parcel#: 3414-501-1904-325/6 Zoning: CG APPLICATION INFORMATION Permit Number: 1503-0462 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Michael P Schlitt Business Name: Michael Schlitt Construction Corp Business Addr: 170E Old Dixie Hwy # 101 City I State I Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS REVIEW COMMENTS 1 Owner(s): Killavaney Property Cdlor10o 810n7 Jurisdiction: SAINT LUCIE COUNTY V113s Lot#: 4 Block: 3 Stories: Automatic Sprinkler System? No Review Type Status Reviewed ev DOCUMENTS MISSING PENDING Dawn Milone 5/11/2015 Comment: ELECTRICAL SUB AGREEMENT. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Dawn Milone Fax Number: 772-567-1553 Email: Mschcon@Yahoo.Com Date Started Date Completed Date Released 3126/2015 312612015 312612015 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 511312015 ALL ELECTRICAL,ENTRY LIGHTING,OUTSIDE LIGHTING WALL PACKS Comment: ELECTRICAL PLAN NEEDS TO SHOW MAKER,MICRO,G.F.C.I.IN SNACK ROOM ON COUNTER 5/1212015 I� IF USED,WATER COOLER,COFFEE TOP,A.C.COND,DISCONECTS AND A.H.,OUTSIDE G.F.C.I.RECP.FOR A.C.MAINT.AND ALL ELECTRICAL JJ NEEDED FOR A COMPLETE JOB PER N.E.CODE.WALT PRIDE SR. PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 5/1212015 3 PLEASE SHOW COMPLIANCE WITH TABLE 403.3 FOR VENTILATION OF THE ASSEMBLY AREAS IN THE 2010 Comment: 5112I2015 FLORIDA MECHANICAL CODE VENTILATION FANS IN ACCORDANCE WITH 403.3 OF THE 2010 FLORIDA Comment: PLEASE SHOW RESTROOM 5113/2015 ✓ MECHANCIAL CODE PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 5/1312015 LOCATION OF HI LO DRINKING FOUNTAIN AND REMOVE FROM PLANS HI LO WATER 1 Comment: PLEASE SHOW WITH SNACK ROOM FOUNTAINS ARE REQUIRED PER TABLE 403.1 5/11/2W5 ---' COOLER NOT REQUIRED .DRINKING AND SECTION 211 FL ACCESSABLE CODE. Comment: PLEASE SHOW LOCATION OF MOP SINK PER SECTION 403 FL PLUMBING CODE 5/11/2015 ti t ! Planning & Development Services^ Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 REVIEW COMMENTS 2 Comment: PLEASE SHOW ADA COMPLIANT RESTROOMS WITH INSIDE DIMENSIONS PER THE 2010 FL 5/1112015 ACCESSABILITY CODE , Comment: DOORS CANNOT SWING INTO ANY CLEAR FLOOR SPACE FOR FIXTURES PER 2010 FL ACCESSABILITY 511112015 CODE 5/11/2015 Comment: PLEASE SHOW ADA COMPLIANT LAVATORIES PER FL ACCESSABILITY CODE. PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 518/2015 Comment: PLANS MUST BE DESIGNED TO EITHER 7,5 OR 15 S.F. PER PERSON "NET" [ FBC TABLE 1004.1.1 ] AND USE THE PROPER SO FOOTAGE FOR THE 2 MEETING HALLS AND THE COFFEE LOUNGE AND CALCULATE ON THE NET AREA' THESE SQUARE FOOTAGES SHOULD NOT CHANGE TO GROSS AREAS AND OCCUPANT LOADS MUST CALCULATE ON THE ACTUAL FLOOR S.F.' SEE DEFINITION OF " NET AREA" FBC CHAPTER 5/8/2015 10' THE ONLY DEDUCTION VIEWABLE, FROM THESE AREAS ARE THE REAR CORRIDOR, HALLWAY AND THE CLOSET BEHIND THE WATER COOLER • SHOW THE TABLE AND CHAIR LAYOUT FOR THE COFFEE LOUNGE OR CALCULATE AT [ 51 S.F. PER PERSON ON PLANS Comment: SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.11 GROUP 5/8/2015 I A / NON SPRINKLED Comment: SHOW AN INTERIOR FINISHES TABLE ON PLANS PER FBC CHAPTER 8' FBC 803 WALL AND CEILING' 804 5!8/2015 I INTERIOR FLOOR FINISHES' SEE TABLE 803.9 Comment: SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [ DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 . SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ] 5/8/2015 SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. 1404.2.4.11 ALL DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.21 ��!! J Comment: SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING 5/8/2015 RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS 5/312015 Commem: THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED / MODIFY PG 1 OF PLANS 5/8/2015 / Comment: DETAIL THE"NEW PARTITION" ON PANS / Comment: ALL PLAN PAGES MUST CO-INCIDE WITH EACH OTHER `CHECK INTERIOR DOOR LOCATIONS AND SHOW 5/8/2015 ALL DOOR SIZES [ FBC 1008.1.1 ] 5/8/2015 I Comment: SHOW ALL REQUIRED LOCATIONS Comment: SHOW DETAILS ON PLANS FOR ALL EXTERIOR HARDWARE TO BE PANIC HARDWARE [ FBC 1008.1.10 ] 5/7112015 WITH ONE EXCEPTION BEING COMPLIANT WITH EXCEPTION 1 FOR THE MAIN EXIT ZONING REVIEW INCOMPLETE Lydia Galbraith 5/11/2015 5/1112015 Comment: WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING? Comment: PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL NEED TO BE 5/11/2015 ; SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO. Tf J[n f�uOtO (/Orz�w.Z Planning 8 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772[462-6443 Address: 8537-8545 S Us Hwy 1 City / State / Zip: Port St. Lucie, FI 34952 Parcel#: 3414-501-1904-32516 Zoning: CG APPLICATION INFORMATION Permit Number: 1503-0462 Permit Type: COMMERCIAL RENOVATION Contractor Name: Michael P Schlitt Business Name: Michael Schlitt Construction Corp Business Addr: 1708 Old Dixie Hwy # 101 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS Review Type DOCUMENTS MISSING 5/11/2015 Comment: FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: 5/8/2015 Comment 5/8/2015 Comment: 5/8/2015 Comment: 7/8/2015 REVIEW COMMENTS SCANNED BY St. Lucia Count Owner(s): Killavaney Property Co Jurisdiction: SAINT LUCIE COUNTY Lot#: 4 Block: 3 Stories: Automatic Sprinkler System? No Fax Number: 772-567-1553 Email: Mschcon@Yahoo.Com Status Reviewed By Date Started Date Completed Date Released PENDING Dawn Milone 312612015 ELECTRICAL SUB AGREEMENT. PENDING Tony Jerger COMPLETE Dawn Milone 312612015 3/2612015 INCOMPLETE Joe Cicio 6/22/2015 SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.11 GROUP A / NON SPRINKLED •••. SECOND REVIEW "" YOU HAVE A NOTE ON PG-1 THAT STATES ADD A" 1 HOUR RATED CEILING PER UL ????"SHOW THE LOCATION ON PLANS FOR THIS RATED CEILING AND IDENTIFY THE UL NUMBER AND DETAILS ON PLANS SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [ DIAGONAL LINES ARE NOT PERMITTED [ LS 7.6.1 - SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ) SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [404.2.4.11 ALL DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.21 ••.. SWING DOOR FROM THE RECEPTION AREA CANNOT SWING INTO THE CORRIDOR [ SEE FBC 1005.21 FOR DOOR ENCROACHMENT INTO A CORRIDOR' THAT PARTICULAR DOOR MAY SWING INTO THE RECEPTION AREA AS LONG AS IT IS SERVING AN OCCUPANT LOAD OF LESS THAN 10 [ SEE FBC 1008.1.2 EXCEPTION 11 SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING RADIUS'S ( SEE FBC ACCESS. 604.3, 605.1 1 DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS [ ENGINEER DID NOT ADDRESS THIS COMMENT) RE -REVIEW THE NEW PLANS DATED 06/08/2015 SHOWS A BOTTLENECK WHERE THE CORRIDOR BREAKS AT THE 2 FRONT ROOMS' CORRIDOR DIMENSION MUST MAINTAIN 44" IN WIDTH PER FBC 1018.2' NOW THERE IS A 30" OPENING FROM CORRIDOR TO FRONT LEFT ASSEMBLY ROOM ??? 7/8/2015 Comment: UPON RE -SUBMITTAL WE WILL NEED [ 31 ORIGINAL S.S.D. PLANS W/ [ 21 PDF DISCS Planning S. Development Services REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:f772)462.2172 Fax:j772)462S443 Page 2 7/8/2015 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 5/1312015 7/612015 71612015 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 5/1212015 71712015 7/7/2015 Comment: PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 6/1312015 71612015 7/6/2015 Comment: PLANS EXAMINER REVIEW COMPLETE Joe Clcio 51812015 6/2212015 612212015 Comment: ZONING REVIEW INCOMPLETE Lydia Galbraith 511112015 511112015 Comment: WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING? 5/11/2015 Comment: PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL NEED TO BE SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO. RE'CE11'ti 40 JUL 141015' Planning& Development Services Building & Code Regulation Division 2300 Virginia Avenue :Fort Pierce, FL. 34982 Phone:(772]462.2172 Fax:(772)462.6443 PROPERTY INFORMA TION Address: 8537-8545 S Us Hwy 1 City / State I Zip: Port St. Lucie, FI 34952 Parcel 3414-501-1904-325/6 Zoning: CG APPLICATION INFORMATION REVIEW COMMENTS By SCANNLL, St. LUC @ Crh inh, Owner(s): Killavaney Property Co Jurisdiction: SAINT LUCIE COUNTY Lot#: 4 Block: 3 1 Permit Number: 1503-0462 Stories: Automatic Sprinkler System? No Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Michael P Schlitt Fax Number: 772-567-1553 Business Name: Michael Schlitt Construction Corp Email: Mschcon@Yahoo.Com Business Addr: 1708 Old Dixie Hwy # 101 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS Review Tvpe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Dawn Milone 3126/2015 5/11/2015 Comment: ELECTRICAL SUB AGREEMENT. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Dawn Milone 3126/2015 3126/2015 Comment: PE REVIEW COMMENTS (2) INCOMPLETE Joe Cicio 6122/2015 Comment: SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.1 ] GROUP /5/8/2015 A / NON SPRINKLED "—SECOND REVIEW —YOU HAVE A NOTE ON PGA THAT STATES ADD A" 1 HOUR RATED CEILING PER UL???? " SHOW THE LOCATION ON PLANS FOR THIS RATED CEILING AND IDENTIFY THE UL NUMBER AND DETAILS ON PLANS Comment: SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [ DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 - SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ] SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [ 404.2.4.1 ] ALL DOORS SHALL SWING IN THE 5182015 DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.2 ] "" SWING DOOR FROM THE RECEPTION AREA CANNOT SWING INTO THE CORRIDOR [ SEE FBC 1005.2 ] FOR DOOR ENCROACHMENT INTO A CORRIDOR' THAT PARTICULAR DOOR MAY SWING INTO THE RECEPTION AREA AS LONG AS IT IS SERVING AN OCCUPANT LOAD OF LESS THAN 10 [ SEE FBC 1008.1.2 EXCEPTION 1 ] Comment: SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING 5/812015 RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS [ ENGINEER DID NOT ADDRESS THIS COMMENT ] RE -REVIEW Comment: THE NEW PLANS DATED 06/08/2015 SHOWS A BOTTLENECK WHERE THE CORRIDOR BREAKS AT THE 2 7/8/2015 FRONT ROOMS' CORRIDOR DIMENSION MUST MAINTAIN 44" IN WIDTH PER FBC 1018.2 • NOW THERE IS A 30" OPENING FROM CORRIDOR TO FRONT LEFT ASSEMBLY ROOM ??? ice" ,f.atritri G�crar� - Planning & Development Services REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue FortPlerce,FL 34902 Piton:(772)462.2172 'Fax:(172)462.6"3 Page 2 7/8/2015 Comment: UPON RE -SUBMITTAL WE WILL NEED [31 ORIGINAL S.S.D. PLANS W/ [ 21 PDF DISCS 7I812015 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 5/1312015 7/6/2015 716/2015 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 5/17/2015 71712015 717/2015 Comment: PLANS EXAMINER PLUMBING COMPLETE - Greg Smyth 511312015 7/6/2016 7/612015 Comment: PLANS EXAMINER REVIEW COMPLETE Joe Cicio 518/2015 6/2212015 6122/2015 Comment: ZONING REVIEW INCOMPLETE Lydia Galbraith 5/11/2015 5/1112015 Comment: WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING? 5/11/2015 Comment: PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL NEED TO BE SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34992 Phone:(772)462a172 fax:(772)462-6443 PROPERTY INFORMATION Address: 8537-8545 S Us Hwy 1 City I State I Zip: Port St. Lucie, FI 34952 Parcel#: 3414-501-1904-325/6 Zoning: CG APPLICATION INFORMATION Permit Number: 1503-0462 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Michael P Schlitt Business Name: Michael Schlitt Construction Corp Business Addr: 1708 Old Dixie Hwy # 101 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS SCANNED REVIEW COMMENTS By Si. Lucie County Page 1 Owner(s): Killavaney Property Cc Jurisdiction: SAINT LUCIE COUNTY Lot#: 4 Block: 3 Stories: Automatic Sprinkler System? No Fax Number: 772-567-1553 Email: Mschcon@Yahoo.Com Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Dawn Milone 312612015 5/11/2015 Comment: ELECTRICAL SUB AGREEMENT. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Dawn Milone 3/26/2015 312612015 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 5/1312015 Comment: ELECTRICAL PLAN NEEDS TO SHOW ALL ELECTRICAL,ENTRY LIGHTING,OUTSIDE LIGHTING WALL PACKS 5/12/2015 IF USED,WATER COOLER,COFFEE MAKER,MICRO,G.F.C.I.IN SNACK ROOM ON COUNTER TOP,A.C.COND,DISCONECTS AND A.H.,OUTSIDE G.F.C.LRECRFOR A.C.MAINT.AND ALL ELECTRICAL NEEDED FOR A COMPLETE JOB PER N.E.CODE.WALT PRIDE SR. PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 5/1212015 5/12/2015 Comment: PLEASE SHOW COMPLIANCE WITH TABLE 403.3 FOR VENTILATION OF THE ASSEMBLY AREAS IN THE 2010 FLORIDA MECHANICAL CODE 5/13/2015 Comment: PLEASE SHOW RESTROOM VENTILATION FANS IN ACCORDANCE WITH 403.3 OF THE 2010 FLORIDA MECHANCIAL CODE PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 5/1312015 Comment: PLEASE SHOW LOCATION OF HI LO DRINKING FOUNTAIN AND REMOVE FROM PLANS HI LO WATER 5/11/2015 COOLER NOT REQUIRED WITH SNACK ROOM .DRINKING FOUNTAINS ARE REQUIRED PER TABLE 403.1 AND SECTION 211 FL ACCESSABLE CODE. 5/11/2015 Comment: PLEASE SHOW LOCATION OF MOP SINK PER SECTION 403 FL PLUMBING CODE Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 rax:(772)462.6443 REVIEW COMMENTS 5/1112015 Comment: PLEASE SHOW ADA COMPLIANT RESTROOMS WITH INSIDE DIMENSIONS PER THE 2010 FL ACCESSABILITY CODE 5/11/2015 Comment: DOORS CANNOT SWING INTO ANY CLEAR FLOOR SPACE FOR FIXTURES PER 2010 FL ACCESSABILITY CODE 5/11/2015 Comment: PLEASE SHOW ADA COMPLIANT LAVATORIES PER FL ACCESSABILITY CODE. PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 5/812015 Comment: PLANS MUST BE DESIGNED TO EITHER 7,5 OR 15 S.F. PER PERSON "NET" [ FBC TABLE 1004.1.1 ] AND USE THE PROPER SQ FOOTAGE FOR THE 2 MEETING HALLS AND THE COFFEE LOUNGE AND CALCULATE ON THE NET AREA' THESE SQUARE FOOTAGES SHOULD NOT CHANGE TO GROSS AREAS AND OCCUPANT 5/8/2015 LOADS MUST CALCULATE ON THE ACTUAL FLOOR S.F. • SEE DEFINITION OF" NET AREA" FBC CHAPTER 10' THE ONLY DEDUCTION VIEWABLE, FROM THESE AREAS ARE THE REAR CORRIDOR, HALLWAY AND THE CLOSET BEHIND THE WATER COOLER `SHOW THE TABLE AND CHAIR LAYOUT FOR THE COFFEE LOUNGE OR CALCULATE AT [ 51 S.F. PER PERSON ON PLANS 5/8/2015 Comment: SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.1 ] GROUP A / NON SPRINKLED 5/8/2015 Comment: SHOW AN INTERIOR FINISHES TABLE ON PLANS PER FBC CHAPTER 8' FBC 803 WALL AND CEILING • 804 INTERIOR FLOOR FINISHES' SEE TABLE 803.9 Comment: SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [ 5/8/2015 DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 • SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ] SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [ 404.2.4.11 ALL DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.2 ] 5/8/2015 Comment: SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS 5/8/2015 Comment: THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED / MODIFY PG 1 OF PLANS 5/8/2015 Comment: DETAIL THE"NEW PARTITION" ON PANS 5/8/2015 Comment: ALL PLAN PAGES MUST CO-INCIDE WITH EACH OTHER' CHECK INTERIOR DOOR LOCATIONS AND SHOW ALL DOOR SIZES [ FBC 1008.1.1 ] 5/8/2015 Comment: SHOW ALL REQUIRED LOCATIONS 5/1112015 Comment: SHOW DETAILS ON PLANS FOR ALL EXTERIOR HARDWARE TO BE PANIC HARDWARE [ FBC 1008.1.10 ] WITH ONE EXCEPTION BEING COMPLIANT WITH EXCEPTION 1 FOR THE MAIN EXIT ZONING REVIEW INCOMPLETE Lydia Galbraith 5/1112015 5/11/2015 Comment: WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING? 511112015 Comment: PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL NEED TO BE SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO. Planning S, Development Services Building & Code Regulation Division 2300 Virginia Avenue "Fort Pierce, FL. 34962 Phone:(772)462.2172 Fax:(7/2)462-6443 PROPERTY INFORMATION Address: 8537-8545 S Us Hwy 1 City / State I Zip: Port St. Lucie, FI 34952 Parcel #: 3414-501-1904-325/6 Zoning: CG APPLICATION INFORMATION Permit Number: 1503-0462 Permit Type: COMMERCIAL RENOVATION Contractor Name: Michael P Schlitt REVIEW CO�(jM kL ,-��111��ENTS RECEI 1J:: 11 _dl5 Business Name: Michael Schlitt Construction Corp Business Addr: 1708 Old Dixie Hwy # 101 City / State I Zip: Vero Beach, FI 32960 SCANNEu BY St. Lucie Cni 1 Owner(s): Killavaney Property Cc Jurisdiction: SAINT LUCIE COUNTY REVIEWS AND COMMENTS Review Type Status Reviewed By .k DOCUMENTS MISSING PENDING Dawn Milone 5/11/2015 Comment: ELECTRICAL SUB AGREEMENT. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Lot#: 4 Block: 3 Stories: Automatic Sprinkler System? No Fax Number: 772-567-1553 Email: Mschcon@Yahoo.Com Date Started Date Completed Date Released 312612015 Comment: FRONT COUNTER REVIEW COMPLETE Dawn Milone 3/2612015 3126/2016 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 6/13/2015 Comment: ELECTRICAL PLAN NEEDS TO SHOW ALL ELECTRICAL,ENTRY LIGHTING,OUTSIDE LIGHTING WALL PACKS IF USED,WATER COOLER,COFFEE MAKER,MICRO,G.F.C.I.IN SNACK ROOM ON COUNTER 5/12/2015 TOP,A.C.COND,DISCONECTS AND A.H.,OUTSIDE G.F.C.I.RECP.FOR A.C.MAINT.AND ALL ELECTRICAL NEEDED FOR A COMPLETE JOB PER N.E.CODE.WALT PRIDE SR. PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 5/1212015 Comment: PLEASE SHOW COMPLIANCE WITH TABLE 403.3 FOR VENTILATION OF THE ASSEMBLY AREAS IN THE 2010 5/12/2015 FLORIDA MECHANICAL CODE Comment: PLEASE SHOW RESTROOM VENTILATION FANS IN ACCORDANCE WITH 403.3 OF THE 2010 FLORIDA 5/13/2015 MECHANCIAL CODE PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 5/1312015 Comment: PLEASE SHOW LOCATION OF HI LO DRINKING FOUNTAIN AND REMOVE FROM PLANS HI LO WATER 5/11/2015 COOLER NOT REQUIRED WITH SNACK ROOM .DRINKING FOUNTAINS ARE REQUIRED PER TABLE 403.1 - AND SECTION 211 FL ACCESSABLE CODE. 5/11/2015 Comment: PLEASE SHOW LOCATION OF MOP SINK PER SECTION 403 FL PLUMBING CODE Planning &Development Services Building & Code Regulation Division 2300 Virginia Avenue FortPierce, FL. 34992 Phone:(772]462.2172 Fax:V72)462-6443 REVIEW COMMENTS 5/11/2015 Comment: PLEASE SHOW ADA COMPLIANT RESTROOMS WITH INSIDE DIMENSIONS PER THE 2010 FL ACCESSABILITY CODE 5/11/2015 Comment: DOORS CANNOT SWING INTO ANY CLEAR FLOOR SPACE FOR FIXTURES PER 2010 FL ACCESSABILITY CODE 5/11/2015 Comment: PLEASE SHOW ADA COMPLIANT LAVATORIES PER FL ACCESSABILITY CODE. PLANS EXAMINER REVIEW INCOMPLETE Joe Cicto 518/2015 Comment PLANS MUST BE DESIGNED TO EITHER 7,5 OR 15 S.F. PER PERSON "NET" [ FBC TABLE 1004.1.1 ] AND,USE THE PROPER SO FOOTAGE FOR THE 2 MEETING HALLS AND THE COFFEE LOUNGE AND CALCULATE ON THE NET AREA • THESE SQUARE FOOTAGES SHOULD NOT CHANGE TO GROSS AREAS AND OCCUPANT 5/8/2015 LOADS MUST CALCULATE ON THE ACTUAL FLOOR S.F. • SEE DEFINITION OF" NET AREA " FBC CHAPTER 10' THE ONLY DEDUCTION VIEWABLE, FROM THESE AREAS ARE THE REAR CORRIDOR, HALLWAY AND THE CLOSET BEHIND THE WATER COOLER' SHOW THE TABLE AND CHAIR LAYOUT FOR THE COFFEE LOUNGE OR CALCULATE AT [ 5 ] S.F. PER PERSON ON PLANS 5/8/2015 Comment: SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.11 GROUP A/ NON SPRINKLED 5/8/2015 Comment: SHOW AN INTERIOR FINISHES TABLE ON PLANS PER FBC CHAPTER 8' FBC 803 WALL AND CEILING' 804 INTERIOR FLOOR FINISHES • SEE TABLE 803.9 Comment: SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS[ 5/8/2015 DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 - SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ] SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [ 404.2.4.1 ] ALL DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.2 ] 5l8/2015 Comment: SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS 5/8/2015 Comment: THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED / MODIFY PG 1 OF PLANS 5/8/2015 Comment: DETAIL THE" NEW PARTITION" ON PANS 5/8/2015 Comment: ALL PLAN PAGES MUST CO-INCIDE WITH EACH OTHER • CHECK INTERIOR DOOR LOCATIONS AND SHOW ALL DOOR SIZES [ FBC 1008.1.1 ] 5/11/2015 Comment: SHOW DETAILS ON PLANS FOR ALL EXTERIOR HARDWARE TO BE PANIC HARDWARE [ FBC 1008.1.10 ] WITH ONE EXCEPTION BEING COMPLIANT WITH EXCEPTION 1 FOR THE MAIN EXIT ZONING REVIEW INCOMPLETE Lydia Galbraith 5/1112015 5/11/2015 Comment: WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING? 5/11/2015 Comment: PLEASE INFORM YOUR CUSTOMER THAT AZONING COMPLIANCE APPLICATION WILL NEED TO BE SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO.