HomeMy WebLinkAboutREVIEW COMMENTSPlanning 6 Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(7721462-2172 Fax:(7721462-6443
PROPERTY/NFORMATION
Address: 8537-8545 S Us Hwy 1
City I State I Zip: Port St. Lucie, FI 34952
Parcel#: 3414-501-1904-325/6
Zoning: CG
APPLICATION INFORMATION
Permit Number: 1503-0462
Permit Type: COMMERCIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name:
Michael P Schlitt
Business Name:
Michael Schlitt Construction Corp
Business Addr:
170E Old Dixie Hwy # 101
City I State I Zip:
Vero Beach, FI 32960
REVIEWS AND COMMENTS
REVIEW COMMENTS
1
Owner(s):
Killavaney Property Cdlor10o 810n7
Jurisdiction: SAINT LUCIE COUNTY V113s
Lot#: 4 Block: 3
Stories: Automatic Sprinkler System? No
Review Type
Status Reviewed ev
DOCUMENTS MISSING
PENDING Dawn Milone
5/11/2015 Comment:
ELECTRICAL SUB AGREEMENT.
FIRE DEPARTMENT REVIEW
PENDING Tony Jerger
Comment:
FRONT COUNTER REVIEW COMPLETE Dawn Milone
Fax Number: 772-567-1553
Email: Mschcon@Yahoo.Com
Date Started Date Completed Date Released
3126/2015
312612015 312612015
Comment:
PLANS EXAMINER ELECTRIC
INCOMPLETE Walter Pride 511312015
ALL ELECTRICAL,ENTRY LIGHTING,OUTSIDE LIGHTING WALL PACKS
Comment:
ELECTRICAL PLAN NEEDS TO SHOW
MAKER,MICRO,G.F.C.I.IN SNACK ROOM ON COUNTER
5/1212015 I�
IF USED,WATER COOLER,COFFEE
TOP,A.C.COND,DISCONECTS AND A.H.,OUTSIDE G.F.C.I.RECP.FOR A.C.MAINT.AND ALL ELECTRICAL
JJ
NEEDED FOR A COMPLETE JOB PER N.E.CODE.WALT PRIDE SR.
PLANS EXAMINER MECHANICAL
INCOMPLETE Carl Peterson 5/1212015
3
PLEASE SHOW COMPLIANCE WITH TABLE 403.3 FOR VENTILATION OF THE ASSEMBLY AREAS IN THE 2010
Comment:
5112I2015
FLORIDA MECHANICAL CODE
VENTILATION FANS IN ACCORDANCE WITH 403.3 OF THE 2010 FLORIDA
Comment:
PLEASE SHOW RESTROOM
5113/2015 ✓
MECHANCIAL CODE
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 5/1312015
LOCATION OF HI LO DRINKING FOUNTAIN AND REMOVE FROM PLANS HI LO WATER
1 Comment:
PLEASE SHOW
WITH SNACK ROOM FOUNTAINS ARE REQUIRED PER TABLE 403.1
5/11/2W5 ---'
COOLER NOT REQUIRED .DRINKING
AND SECTION 211 FL ACCESSABLE CODE.
Comment:
PLEASE SHOW LOCATION OF MOP SINK PER SECTION 403 FL PLUMBING CODE
5/11/2015 ti
t !
Planning & Development Services^
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462-2172 Fax:(772)462.6443
REVIEW COMMENTS
2
Comment:
PLEASE SHOW ADA COMPLIANT RESTROOMS WITH INSIDE DIMENSIONS PER THE 2010 FL
5/1112015
ACCESSABILITY CODE ,
Comment:
DOORS CANNOT SWING INTO ANY CLEAR FLOOR SPACE FOR FIXTURES PER 2010 FL ACCESSABILITY
511112015
CODE
5/11/2015 Comment:
PLEASE SHOW ADA COMPLIANT LAVATORIES PER FL ACCESSABILITY CODE.
PLANS EXAMINER REVIEW
INCOMPLETE Joe Cicio 518/2015
Comment:
PLANS MUST BE DESIGNED TO EITHER 7,5 OR 15 S.F. PER PERSON "NET" [ FBC TABLE 1004.1.1 ] AND USE
THE PROPER SO FOOTAGE FOR THE 2 MEETING HALLS AND THE COFFEE LOUNGE AND CALCULATE ON
THE NET AREA' THESE SQUARE FOOTAGES SHOULD NOT CHANGE TO GROSS AREAS AND OCCUPANT
LOADS MUST CALCULATE ON THE ACTUAL FLOOR S.F.' SEE DEFINITION OF " NET AREA" FBC CHAPTER
5/8/2015
10' THE ONLY DEDUCTION VIEWABLE, FROM THESE AREAS ARE THE REAR CORRIDOR, HALLWAY AND
THE CLOSET BEHIND THE WATER COOLER • SHOW THE TABLE AND CHAIR LAYOUT FOR THE COFFEE
LOUNGE OR CALCULATE AT [ 51 S.F. PER PERSON
ON PLANS
Comment:
SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.11 GROUP
5/8/2015 I
A / NON SPRINKLED
Comment:
SHOW AN INTERIOR FINISHES TABLE ON PLANS PER FBC CHAPTER 8' FBC 803 WALL AND CEILING' 804
5!8/2015 I
INTERIOR FLOOR FINISHES' SEE TABLE 803.9
Comment:
SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [
DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 . SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ]
5/8/2015
SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. 1404.2.4.11 ALL DOORS SHALL SWING IN THE
DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.21
��!!
J Comment:
SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING
5/8/2015
RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS
5/312015 Commem:
THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED / MODIFY PG 1 OF PLANS
5/8/2015 / Comment:
DETAIL THE"NEW PARTITION" ON PANS
/ Comment:
ALL PLAN PAGES MUST CO-INCIDE WITH EACH OTHER `CHECK INTERIOR DOOR LOCATIONS AND SHOW
5/8/2015
ALL DOOR SIZES [ FBC 1008.1.1 ]
5/8/2015 I Comment:
SHOW ALL REQUIRED LOCATIONS
Comment:
SHOW DETAILS ON PLANS FOR ALL EXTERIOR HARDWARE TO BE PANIC HARDWARE [ FBC 1008.1.10 ]
5/7112015
WITH ONE EXCEPTION BEING COMPLIANT WITH EXCEPTION 1 FOR THE MAIN EXIT
ZONING REVIEW
INCOMPLETE Lydia Galbraith 5/11/2015
5/1112015 Comment:
WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING?
Comment:
PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL NEED TO BE
5/11/2015 ;
SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO.
Tf
J[n f�uOtO (/Orz�w.Z
Planning 8 Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 Fax:(772[462-6443
Address:
8537-8545 S Us Hwy 1
City / State / Zip:
Port St. Lucie, FI 34952
Parcel#:
3414-501-1904-32516
Zoning:
CG
APPLICATION INFORMATION
Permit Number: 1503-0462
Permit Type: COMMERCIAL RENOVATION
Contractor Name:
Michael P Schlitt
Business Name:
Michael Schlitt Construction Corp
Business Addr:
1708 Old Dixie Hwy # 101
City / State / Zip:
Vero Beach, FI 32960
REVIEWS AND COMMENTS
Review Type
DOCUMENTS MISSING
5/11/2015 Comment:
FIRE DEPARTMENT REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PE REVIEW COMMENTS (2)
Comment:
5/8/2015
Comment
5/8/2015
Comment:
5/8/2015
Comment:
7/8/2015
REVIEW COMMENTS SCANNED
BY
St. Lucia Count
Owner(s):
Killavaney Property Co
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 4 Block: 3
Stories: Automatic Sprinkler System? No
Fax Number: 772-567-1553
Email: Mschcon@Yahoo.Com
Status Reviewed By Date Started Date Completed Date Released
PENDING Dawn Milone 312612015
ELECTRICAL SUB AGREEMENT.
PENDING Tony Jerger
COMPLETE Dawn Milone 312612015 3/2612015
INCOMPLETE Joe Cicio 6/22/2015
SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.11 GROUP
A / NON SPRINKLED •••. SECOND REVIEW "" YOU HAVE A NOTE ON PG-1 THAT STATES ADD A" 1 HOUR
RATED CEILING PER UL ????"SHOW THE LOCATION ON PLANS FOR THIS RATED CEILING AND IDENTIFY
THE UL NUMBER AND DETAILS ON PLANS
SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [
DIAGONAL LINES ARE NOT PERMITTED [ LS 7.6.1 - SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 )
SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [404.2.4.11 ALL DOORS SHALL SWING IN THE
DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.21 ••.. SWING DOOR FROM THE RECEPTION AREA CANNOT
SWING INTO THE CORRIDOR [ SEE FBC 1005.21 FOR DOOR ENCROACHMENT INTO A CORRIDOR' THAT
PARTICULAR DOOR MAY SWING INTO THE RECEPTION AREA AS LONG AS IT IS SERVING AN OCCUPANT
LOAD OF LESS THAN 10 [ SEE FBC 1008.1.2 EXCEPTION 11
SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING
RADIUS'S ( SEE FBC ACCESS. 604.3, 605.1 1 DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS [
ENGINEER DID NOT ADDRESS THIS COMMENT) RE -REVIEW
THE NEW PLANS DATED 06/08/2015 SHOWS A BOTTLENECK WHERE THE CORRIDOR BREAKS AT THE 2
FRONT ROOMS' CORRIDOR DIMENSION MUST MAINTAIN 44" IN WIDTH PER FBC 1018.2' NOW THERE IS A
30" OPENING FROM CORRIDOR TO FRONT LEFT ASSEMBLY ROOM ???
7/8/2015 Comment: UPON RE -SUBMITTAL WE WILL NEED [ 31 ORIGINAL S.S.D. PLANS W/ [ 21 PDF DISCS
Planning S. Development Services REVIEW COMMENTS
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:f772)462.2172 Fax:j772)462S443
Page 2
7/8/2015 Comment:
COMMENTS MAILED AND E-MAILED AS OF THIS DATE
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride 5/1312015
7/612015
71612015
Comment:
PLANS EXAMINER MECHANICAL
COMPLETE Carl Peterson 5/1212015
71712015
7/7/2015
Comment:
PLANS EXAMINER PLUMBING
COMPLETE Greg Smyth 6/1312015
71612015
7/6/2015
Comment:
PLANS EXAMINER REVIEW
COMPLETE Joe Clcio 51812015
6/2212015
612212015
Comment:
ZONING REVIEW
INCOMPLETE Lydia Galbraith 511112015
511112015 Comment:
WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING?
5/11/2015 Comment:
PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL
NEED TO BE
SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO.
RE'CE11'ti 40 JUL 141015'
Planning& Development Services
Building & Code Regulation Division
2300 Virginia Avenue
:Fort Pierce, FL. 34982
Phone:(772]462.2172 Fax:(772)462.6443
PROPERTY INFORMA TION
Address: 8537-8545 S Us Hwy 1
City / State I Zip: Port St. Lucie, FI 34952
Parcel 3414-501-1904-325/6
Zoning: CG
APPLICATION INFORMATION
REVIEW COMMENTS
By
SCANNLL,
St. LUC @ Crh inh,
Owner(s):
Killavaney Property Co
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 4
Block: 3
1
Permit Number:
1503-0462 Stories: Automatic Sprinkler System? No
Permit Type:
COMMERCIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name:
Michael P Schlitt Fax Number: 772-567-1553
Business Name:
Michael Schlitt Construction Corp
Email: Mschcon@Yahoo.Com
Business Addr:
1708 Old Dixie Hwy # 101
City / State / Zip:
Vero Beach, FI 32960
REVIEWS AND COMMENTS
Review Tvpe
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Dawn Milone 3126/2015
5/11/2015
Comment: ELECTRICAL SUB AGREEMENT.
FIRE DEPARTMENT REVIEW PENDING Tony Jerger
Comment:
FRONT COUNTER REVIEW COMPLETE Dawn Milone 3126/2015 3126/2015
Comment:
PE REVIEW COMMENTS (2) INCOMPLETE Joe Cicio 6122/2015
Comment: SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.1 ] GROUP
/5/8/2015
A / NON SPRINKLED "—SECOND REVIEW —YOU HAVE A NOTE ON PGA THAT STATES ADD A" 1 HOUR
RATED CEILING PER UL???? " SHOW THE LOCATION ON PLANS FOR THIS RATED CEILING AND IDENTIFY
THE UL NUMBER AND DETAILS ON PLANS
Comment: SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [
DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 - SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ]
SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [ 404.2.4.1 ] ALL DOORS SHALL SWING IN THE
5182015
DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.2 ] "" SWING DOOR FROM THE RECEPTION AREA CANNOT
SWING INTO THE CORRIDOR [ SEE FBC 1005.2 ] FOR DOOR ENCROACHMENT INTO A CORRIDOR' THAT
PARTICULAR DOOR MAY SWING INTO THE RECEPTION AREA AS LONG AS IT IS SERVING AN OCCUPANT
LOAD OF LESS THAN 10 [ SEE FBC 1008.1.2 EXCEPTION 1 ]
Comment: SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING
5/812015
RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS [
ENGINEER DID NOT ADDRESS THIS COMMENT ] RE -REVIEW
Comment: THE NEW PLANS DATED 06/08/2015 SHOWS A BOTTLENECK WHERE THE CORRIDOR BREAKS AT THE 2
7/8/2015
FRONT ROOMS' CORRIDOR DIMENSION MUST MAINTAIN 44" IN WIDTH PER FBC 1018.2 • NOW THERE IS A
30" OPENING FROM CORRIDOR TO FRONT LEFT ASSEMBLY ROOM ???
ice" ,f.atritri G�crar� -
Planning & Development Services REVIEW COMMENTS
Building & Code Regulation Division
2300 Virginia Avenue
FortPlerce,FL 34902
Piton:(772)462.2172 'Fax:(172)462.6"3
Page 2
7/8/2015 Comment:
UPON RE -SUBMITTAL WE WILL NEED [31 ORIGINAL S.S.D. PLANS W/ [ 21 PDF DISCS
7I812015 Comment:
COMMENTS MAILED AND E-MAILED AS OF THIS DATE
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride 5/1312015 7/6/2015
716/2015
Comment:
PLANS EXAMINER MECHANICAL
COMPLETE Carl Peterson 5/17/2015 71712015
717/2015
Comment:
PLANS EXAMINER PLUMBING
COMPLETE - Greg Smyth 511312015 7/6/2016
7/612015
Comment:
PLANS EXAMINER REVIEW
COMPLETE Joe Cicio 518/2015 6/2212015
6122/2015
Comment:
ZONING REVIEW
INCOMPLETE Lydia Galbraith 5/11/2015
5/1112015 Comment:
WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING?
5/11/2015 Comment:
PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL NEED TO BE
SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34992
Phone:(772)462a172 fax:(772)462-6443
PROPERTY INFORMATION
Address: 8537-8545 S Us Hwy 1
City I State I Zip: Port St. Lucie, FI 34952
Parcel#: 3414-501-1904-325/6
Zoning: CG
APPLICATION INFORMATION
Permit Number: 1503-0462
Permit Type: COMMERCIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name:
Michael P Schlitt
Business Name:
Michael Schlitt Construction Corp
Business Addr:
1708 Old Dixie Hwy # 101
City / State / Zip:
Vero Beach, FI 32960
REVIEWS AND COMMENTS
SCANNED
REVIEW COMMENTS By
Si. Lucie County
Page 1
Owner(s):
Killavaney Property Cc
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 4 Block: 3
Stories: Automatic Sprinkler System? No
Fax Number: 772-567-1553
Email: Mschcon@Yahoo.Com
Review Type
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Dawn Milone 312612015
5/11/2015 Comment:
ELECTRICAL SUB AGREEMENT.
FIRE DEPARTMENT REVIEW
PENDING Tony Jerger
Comment:
FRONT COUNTER REVIEW
COMPLETE Dawn Milone 3/26/2015 312612015
Comment:
PLANS EXAMINER ELECTRIC
INCOMPLETE Walter Pride 5/1312015
Comment:
ELECTRICAL PLAN NEEDS TO SHOW ALL ELECTRICAL,ENTRY LIGHTING,OUTSIDE LIGHTING WALL PACKS
5/12/2015
IF USED,WATER COOLER,COFFEE MAKER,MICRO,G.F.C.I.IN SNACK ROOM ON COUNTER
TOP,A.C.COND,DISCONECTS AND A.H.,OUTSIDE G.F.C.LRECRFOR A.C.MAINT.AND ALL ELECTRICAL
NEEDED FOR A COMPLETE JOB PER N.E.CODE.WALT PRIDE SR.
PLANS EXAMINER MECHANICAL
INCOMPLETE Carl Peterson 5/1212015
5/12/2015 Comment:
PLEASE SHOW COMPLIANCE WITH TABLE 403.3 FOR VENTILATION OF THE ASSEMBLY AREAS IN THE 2010
FLORIDA MECHANICAL CODE
5/13/2015 Comment:
PLEASE SHOW RESTROOM VENTILATION FANS IN ACCORDANCE WITH 403.3 OF THE 2010 FLORIDA
MECHANCIAL CODE
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 5/1312015
Comment:
PLEASE SHOW LOCATION OF HI LO DRINKING FOUNTAIN AND REMOVE FROM PLANS HI LO WATER
5/11/2015
COOLER NOT REQUIRED WITH SNACK ROOM .DRINKING FOUNTAINS ARE REQUIRED PER TABLE 403.1
AND SECTION 211 FL ACCESSABLE CODE.
5/11/2015 Comment:
PLEASE SHOW LOCATION OF MOP SINK PER SECTION 403 FL PLUMBING CODE
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 rax:(772)462.6443
REVIEW COMMENTS
5/1112015 Comment: PLEASE SHOW ADA COMPLIANT RESTROOMS WITH INSIDE DIMENSIONS PER THE 2010 FL
ACCESSABILITY CODE
5/11/2015 Comment: DOORS CANNOT SWING INTO ANY CLEAR FLOOR SPACE FOR FIXTURES PER 2010 FL ACCESSABILITY
CODE
5/11/2015 Comment: PLEASE SHOW ADA COMPLIANT LAVATORIES PER FL ACCESSABILITY CODE.
PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 5/812015
Comment: PLANS MUST BE DESIGNED TO EITHER 7,5 OR 15 S.F. PER PERSON "NET" [ FBC TABLE 1004.1.1 ] AND USE
THE PROPER SQ FOOTAGE FOR THE 2 MEETING HALLS AND THE COFFEE LOUNGE AND CALCULATE ON
THE NET AREA' THESE SQUARE FOOTAGES SHOULD NOT CHANGE TO GROSS AREAS AND OCCUPANT
5/8/2015
LOADS MUST CALCULATE ON THE ACTUAL FLOOR S.F. • SEE DEFINITION OF" NET AREA" FBC CHAPTER
10' THE ONLY DEDUCTION VIEWABLE, FROM THESE AREAS ARE THE REAR CORRIDOR, HALLWAY AND
THE CLOSET BEHIND THE WATER COOLER `SHOW THE TABLE AND CHAIR LAYOUT FOR THE COFFEE
LOUNGE OR CALCULATE AT [ 51 S.F. PER PERSON
ON PLANS
5/8/2015
Comment: SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.1 ] GROUP
A / NON SPRINKLED
5/8/2015
Comment: SHOW AN INTERIOR FINISHES TABLE ON PLANS PER FBC CHAPTER 8' FBC 803 WALL AND CEILING • 804
INTERIOR FLOOR FINISHES' SEE TABLE 803.9
Comment: SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS [
5/8/2015
DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 • SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ]
SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [ 404.2.4.11 ALL DOORS SHALL SWING IN THE
DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.2 ]
5/8/2015
Comment: SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING
RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS
5/8/2015
Comment: THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED / MODIFY PG 1 OF PLANS
5/8/2015
Comment: DETAIL THE"NEW PARTITION" ON PANS
5/8/2015
Comment: ALL PLAN PAGES MUST CO-INCIDE WITH EACH OTHER' CHECK INTERIOR DOOR LOCATIONS AND SHOW
ALL DOOR SIZES [ FBC 1008.1.1 ]
5/8/2015
Comment: SHOW ALL REQUIRED LOCATIONS
5/1112015
Comment: SHOW DETAILS ON PLANS FOR ALL EXTERIOR HARDWARE TO BE PANIC HARDWARE [ FBC 1008.1.10 ]
WITH ONE EXCEPTION BEING COMPLIANT WITH EXCEPTION 1 FOR THE MAIN EXIT
ZONING REVIEW
INCOMPLETE Lydia Galbraith 5/1112015
5/11/2015
Comment: WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING?
511112015
Comment: PLEASE INFORM YOUR CUSTOMER THAT A ZONING COMPLIANCE APPLICATION WILL NEED TO BE
SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO.
Planning S, Development Services
Building & Code Regulation Division
2300 Virginia Avenue
"Fort Pierce, FL. 34962
Phone:(772)462.2172 Fax:(7/2)462-6443
PROPERTY INFORMATION
Address: 8537-8545 S Us Hwy 1
City / State I Zip: Port St. Lucie, FI 34952
Parcel #: 3414-501-1904-325/6
Zoning: CG
APPLICATION INFORMATION
Permit Number: 1503-0462
Permit Type: COMMERCIAL RENOVATION
Contractor Name: Michael P Schlitt
REVIEW CO�(jM
kL ,-��111��ENTS
RECEI 1J:: 11 _dl5
Business Name: Michael Schlitt Construction Corp
Business Addr: 1708 Old Dixie Hwy # 101
City / State I Zip: Vero Beach, FI 32960
SCANNEu
BY
St. Lucie Cni
1
Owner(s):
Killavaney Property Cc
Jurisdiction: SAINT LUCIE COUNTY
REVIEWS AND COMMENTS
Review Type Status Reviewed By
.k DOCUMENTS MISSING PENDING Dawn Milone
5/11/2015 Comment: ELECTRICAL SUB AGREEMENT.
FIRE DEPARTMENT REVIEW PENDING Tony Jerger
Lot#: 4 Block: 3
Stories: Automatic Sprinkler System? No
Fax Number: 772-567-1553
Email: Mschcon@Yahoo.Com
Date Started Date Completed Date Released
312612015
Comment:
FRONT COUNTER REVIEW
COMPLETE Dawn Milone 3/2612015 3126/2016
Comment:
PLANS EXAMINER ELECTRIC
INCOMPLETE Walter Pride 6/13/2015
Comment:
ELECTRICAL PLAN NEEDS TO SHOW ALL ELECTRICAL,ENTRY LIGHTING,OUTSIDE LIGHTING WALL PACKS
IF USED,WATER COOLER,COFFEE MAKER,MICRO,G.F.C.I.IN SNACK ROOM ON COUNTER
5/12/2015
TOP,A.C.COND,DISCONECTS AND A.H.,OUTSIDE G.F.C.I.RECP.FOR A.C.MAINT.AND ALL ELECTRICAL
NEEDED FOR A COMPLETE JOB PER N.E.CODE.WALT PRIDE SR.
PLANS EXAMINER MECHANICAL
INCOMPLETE Carl Peterson 5/1212015
Comment:
PLEASE SHOW COMPLIANCE WITH TABLE 403.3 FOR VENTILATION OF THE ASSEMBLY AREAS IN THE 2010
5/12/2015
FLORIDA MECHANICAL CODE
Comment:
PLEASE SHOW RESTROOM VENTILATION FANS IN ACCORDANCE WITH 403.3 OF THE 2010 FLORIDA
5/13/2015
MECHANCIAL CODE
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 5/1312015
Comment:
PLEASE SHOW LOCATION OF HI LO DRINKING FOUNTAIN AND REMOVE FROM PLANS HI LO WATER
5/11/2015
COOLER NOT REQUIRED WITH SNACK ROOM .DRINKING FOUNTAINS ARE REQUIRED PER TABLE 403.1
-
AND SECTION 211 FL ACCESSABLE CODE.
5/11/2015 Comment:
PLEASE SHOW LOCATION OF MOP SINK PER SECTION 403 FL PLUMBING CODE
Planning &Development Services
Building & Code Regulation Division
2300 Virginia Avenue
FortPierce, FL. 34992
Phone:(772]462.2172 Fax:V72)462-6443
REVIEW COMMENTS
5/11/2015
Comment:
PLEASE SHOW ADA COMPLIANT RESTROOMS WITH INSIDE DIMENSIONS PER THE 2010 FL ACCESSABILITY
CODE
5/11/2015
Comment:
DOORS CANNOT SWING INTO ANY CLEAR FLOOR SPACE FOR FIXTURES PER 2010 FL ACCESSABILITY
CODE
5/11/2015
Comment:
PLEASE SHOW ADA COMPLIANT LAVATORIES PER FL ACCESSABILITY CODE.
PLANS EXAMINER REVIEW
INCOMPLETE Joe Cicto 518/2015
Comment
PLANS MUST BE DESIGNED TO EITHER 7,5 OR 15 S.F. PER PERSON "NET" [ FBC TABLE 1004.1.1 ] AND,USE
THE PROPER SO FOOTAGE FOR THE 2 MEETING HALLS AND THE COFFEE LOUNGE AND CALCULATE ON
THE NET AREA • THESE SQUARE FOOTAGES SHOULD NOT CHANGE TO GROSS AREAS AND OCCUPANT
5/8/2015
LOADS MUST CALCULATE ON THE ACTUAL FLOOR S.F. • SEE DEFINITION OF" NET AREA " FBC CHAPTER
10' THE ONLY DEDUCTION VIEWABLE, FROM THESE AREAS ARE THE REAR CORRIDOR, HALLWAY AND
THE CLOSET BEHIND THE WATER COOLER' SHOW THE TABLE AND CHAIR LAYOUT FOR THE COFFEE
LOUNGE OR CALCULATE AT [ 5 ] S.F. PER PERSON
ON PLANS
5/8/2015 Comment:
SHOW THE DETAILS ON PLANS FOR THE REQUIRED RATED CORRIDORS [ SEE FBC TABLE 1016.11 GROUP
A/ NON SPRINKLED
5/8/2015 Comment:
SHOW AN INTERIOR FINISHES TABLE ON PLANS PER FBC CHAPTER 8' FBC 803 WALL AND CEILING' 804
INTERIOR FLOOR FINISHES • SEE TABLE 803.9
Comment:
SHOW LIFE SAFETY TRAVEL DISTANCES FROM ALL AREAS OF THE FACILITY TO ALL APPROVED EXITS[
5/8/2015
DIAGONAL LINES ARE NOT PERMITTED ] LS 7.6.1 - SHOW ALL SWING DOOR SIZES ON PLANS [ 1008.1.1 ]
SHOW ALL ACCESSIBLE CLEARANCES FBC ACCESS. [ 404.2.4.1 ] ALL DOORS SHALL SWING IN THE
DIRECTION OF EGRESS TRAVEL [ FBC 1008.1.2 ]
5l8/2015 Comment:
SHOW THE CLEAR FLOOR SPACES IN THE RESTROOMS FOR THE FIXTURES WITH THE TURNING
RADIUS'S [ SEE FBC ACCESS. 604.3, 605.1 ] DESIGN RESTROOMS TO FBC ACCESS 603 ON PLANS
5/8/2015 Comment:
THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED / MODIFY PG 1 OF PLANS
5/8/2015 Comment:
DETAIL THE" NEW PARTITION" ON PANS
5/8/2015 Comment:
ALL PLAN PAGES MUST CO-INCIDE WITH EACH OTHER • CHECK INTERIOR DOOR LOCATIONS AND SHOW
ALL DOOR SIZES [ FBC 1008.1.1 ]
5/11/2015 Comment:
SHOW DETAILS ON PLANS FOR ALL EXTERIOR HARDWARE TO BE PANIC HARDWARE [ FBC 1008.1.10 ]
WITH ONE EXCEPTION BEING COMPLIANT WITH EXCEPTION 1 FOR THE MAIN EXIT
ZONING REVIEW
INCOMPLETE Lydia Galbraith 5/1112015
5/11/2015 Comment:
WHAT TYPE OF BUSINESS IS GOING TO OCCUPY THIS BUILDING?
5/11/2015 Comment:
PLEASE INFORM YOUR CUSTOMER THAT AZONING COMPLIANCE APPLICATION WILL NEED TO BE
SUBMITTED BEFORE WE CAN APPROVE FINAL INSPECTION AND CO.