Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance ..., . . Project Name: SAINT LUCIE COUNTY FAIR ASSOC. SMALL ANIMAL EXIBIT , Project Address: SS601' W. MIDWAY RD. FORT PIERCE, Fl. -- "+`- Permit#: OccupancyTY*— ' '" A-3 ,. Const_ructionTyp& V iN-5TRUCTIONS FOR USE: ` " SCANNED BY St LL Cje County ' • This certification must be completed, signed, and sealed bylhe'design professional of record: " • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or. multhfamily)- - - - o Residential Addition o Any accessory structure requiring a building permit o Any non, residential structure-, ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED•`(Complete all that apply) 1. DESIGN CODE: Florida Bulldine- _Code 2010 Edition with 2012 - '---'S- upplements using ASCE 7 10 ` 2. Structure Designed as`(check one):', X Enclosed _ partially Enclosed Open 1 • 3. Risk Category; _1 II X III IV Exposure Category. B X C D 4. Design Wind, Velocity,,, ,. 165';, mph:: 128 --ASD-N/ALRFD End Zone Width: 5 ft S. Mean Roof Height: `IS ft " Roof Pitch; _i :12 Parapet: 1 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 1�kgft @ 15'MRH, clearly label on all plan openings): 16.0 16.0 16.0. ; 358, . Zone1:= Zone2:--• Zone 3: ti, Zone4: k Zonei: '358 'Garage: " N/A t' -35.8 -60.0 90.3 -38.8 -47.9 N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: , S^ ~'pSF Roof/Live: 20 "Balcon'y: • N/A PSF Dock: N/A PSFDeck:-N/A-PSFStalrs:- N/A.;PSFFence•-•-N/A--PSF Railings: N/A PLF/CONCENTRATED 8. Were Shear Walls Considered Foy Structure? X Yes _NotAppliwble ExplainWhy Not 9. Is A Continuous_Load Path P.r'ovide8?- X Yes_NotApph66 Explain Why Not:, 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION'STATEMENT I certify that, to the best of my knowledge and belief,'the attached plans & speafications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. 2994S / 5115 '► 1 ` - a, print Name` " ' Cert # & Co. Cert Auth. Paul Welch Inc. 6%B/zols 'Signature, Date, and Seal _1984 5.W.:Biltmore St. Suite #114 Port St. Lucie, FL sLctiUv roan # WU-22 xewseo i/is/iz lis a Address LE