Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEF1ori&i,Energy Efficiency Code For Building Construction EnergyGauge Summit@) Fla/Com-2010, Effective Date: March,l5 2012 '=- Form 506-2010 • Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: SLC FAIR SCANNED Description: SMALL ANIMAL CTR Owner: ST. LUCIE COUNTY FAIR BY Addressl: OKEECHOBEE/MIDWAYRD LUCIe CQUf11]/ City: ST. LUCIE CO. Addmss2: State: FL Zip: 0 Type: Workshop Class: New Finished building Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Conditioned Area: 850 SF Conditioned & UnConditioned Area: 850 SF No of Stories: 1 Area entered from Plans 850 SF Permit No: 0 Max Tonnage 3 If different, write in: RECEPF-D APR 2 9 2015 Public Works St. Lucie County, FL L"' CO F 1: ry EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/27/2015 Page I of Component Gross Energy Cost (in $) LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design Criteria Result 1,324.0 1,444.0 PASSED PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/27/2015 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: PAUL WELCH, P.E. Building Official: Date: APR 312W5 Date: I certify that this building is in compliance with the FLorida EnergyEfficiencyCode Owner Agent: ST. LUCIE CO. FAIR kA4 Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: PAUL WELCK P.E. Reg No: 29945 Lighting Designer: PAUL WELCH, P.E. Reg No: 29945 Mechanical Designer: PAUL WELCH, P.E. Reg No: 29945 Plumbing Designer: PAUL WELCH, P.E. Reg No: 29945 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit0 FlalCom-2010. Section 506.4 CompliantSoftware. Effective Date: March 15, 2012 4/27/2015 Page 3 of 7 Project: SLC FArR Title: SMALLANIMAL CTR Type: Workshop (WEA File: FL_ST_LUCIE_CO_D T ,.tm3) Building End Uses 1) Proposed 2) Baseline Total 82.30 112.30 $1,324 $1,805 ELECMCrrY(MBtulkWh($) 82.30 112.30 24125 32880 $1,324 $1,805 AREA LIGHTS 13.40 16.90 3920 4946 $215 S272 MISC EQUIPMT 4.30 4.30 1245 1245 $68 $68 PUMPS & MISC 0.10 0.10 26 21 $1 $1 SPACE COOL 37.30 53.10 10941 15559 S601 $854 SPACE HEAT 5.30 5.70 1562 1682 $86 S92 VENT FANS 21.90 32.20 6431 9427 $353 $518 Credits Applied: None PASSES Passing Criteria =1444 Design (including any credits) =1324 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 73.4% EnergyGauge Summit) Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/27/2015 Page 4 of 7 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: SLC FAIR Title: SMALLANIMALCTR Type: Workshop (WEA File: FL_ST_LUCIE_CO_INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ED (sq.ft) CP CP once SLC FAIR 31,001 Workshop 850 4 1 PASSES PASSES Project: SLC FAIR Title: SMALLANIMALCTR Type: Workshop (WEA File: FL_ST_LUCIE_CO INTL.tm3) System Report Compliance SLC FAIR System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 12.23 1.00 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling System Air Handler (Supply) - 0.80 0.82 PASSES -Supply Constant Volume PASSES EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/27/2015 Page 5 of 7 Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV Hance None Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance None Piping System Compliance Category Pipe Din Is Operating Ins Cond Ins Req Ins [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.Fj None EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/27/2015 Page 6 of 7 a: SLC FAIR SMALLANIMALCTR Workshop File: FL ST_LUC1E_CO_INTL.tm3) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 506.4.2 Input Report Print -Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows & Doors 502.3.2 Glazed swinging entrance & revolving doors: max. 1.0 cfln/ft2; all other products: 0.3 cfin/ft' Joints/Cracks 502.3.3 To be caulked, gasketed, weather-stripped or otherwise sealed ❑ Dropped Ceiling Cavity 502.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & ❑ side walls HVAC Efficiency 503.2.3 Minimum efficiencies: Tables 503.2.3(1)-(8) ❑ HVAC Controls 503.2.4 Zone controls prevent reheat (exceptions); separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply & exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts, fittings, mechanical equipment & plenum chambers shall El be mechanically attached, sealed, insulated & installed per Table 503.2.7.2. Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s) tested & balanced. Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water. In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2. Heat trap required. Swimming Pools 504.7 Vapor -retardant or liquid cover or other means proven to reduce heat loss on heated pools; Time switch (exceptions); readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2, 502.3 Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluorescent lamps>30W 4/27/2015 EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 Page 7 of EnergyGauge Summit® v4.10 INPUT DATA REPOR Proiect Information Project Name: SLC FAIR Project Title: SMALL ANIMAL CTR Address: OKEECHOBEE / MIDWAY RD State: FL Zip: 0 Owner: ST. LUCIE COUNTY FAIR Orientation: North Building Type: Workshop Building Classification: New Finished building No.of Stories: 1 GrossArea: 850 SF Zones No Acronym Description Type Area [s11 Multiplier Tbtal Area Isf] I SLC FAIR Zone I CONDITIONED 850.0 1 850.0 ❑ Spaces No Acronym Description Type Depth [ft] Width Height Multi [ft] [It] plier Total Area [st1 Total Volume [cq 4/27/2015 EnergyGauge Summit® v4.10 1 bi Zone: SLC FAIR 1 SLC FAIR Zo0Sp1 Workshop 50.00 17.00 10.00 1 850.0 8500.0 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: SLC FAIR In Space: SLC FAIR 1 Recessed Fluorescent - General Lighting 10 128 1280 Manual On/Off 4 ❑ No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity Vb/cf] [h.sEF/Btu] [Btu/sEF] In Zone: SLC FAHt 1 CBS 5/8" stucco 34.00 10.00 1 340.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 CBS 5/8" stucco 34.00 10.00 1 340.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" 3 CBS 5 8' stucco 50.00 10.00 1 500.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 CBS in. stucco, 50.00 10.00 1 500.0 North 0.0838 11.224 50.24 11.9 ❑ 2"styro,8"CMU,lx2 x24"oc, airspace, 0.5" gyp 4/27/2015 EnergyGauge Summit® v4.10 Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F1 [ft] [ft] plier [sf1 In Zone: SLC FAIR In Wall: E WALL I SHW User Defined No 1.2500 0.82 0.76 8.00 4.00 1 32.0 ❑ In Wall: S WALL 1 SHW User Defined No 1.2500 0.82 0.76 8.00 4.00 1 32.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf1 [Btu/hr. sE F1 [Ib/cf1 [Btu/sL F1 [h.sEFBtu] In Zone: In Wall: Roofs No Description Type Width H(Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [it] [it] plier [sf1 [deg] [Btu/hr. Sf. F] [Btu/sE 11 [Ib/cf1 [h.sLF/Btu] in Zone: SLC FAIR 1 MYL Mtl Bldg Roof/R-19 34.00 50.00 1 1700.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Bta/hr sf F] Ift] [ft] [S11 ]SA 4/27/2015 EnergyGauge Summit® v4.10 In Zone: In Roof: Floors No Description Type Width [ft] H (Effec) Multi [ft] plier Area Cond. Heat Cap. Is!] [Btu/hr. sE F] [Btu/sE F] Dens. R-Value [lb/cf] [h.sf.F/Btu] In Zone: SLC FAIR 1 CONC I ft. soil, concrete floor, carpet and rubber pad 34.00 50.00 1 1700.0 0.2681 34.00 113.33 3.73 ❑ Systems SLC FAIR System 1 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 36000.00 44000.00 1200.00 13.00 1.00 1.00 0.80 ❑ ❑ ❑ Plant Equipment Category Size Inst.No Ef. . IPLV Water Heaters W-Heater Description CapacitlCap.Ifnit I/P Rt. Efficiency Loss 4/27/2015 EnergyGauge Summit® v4.10 Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sVft/No] Control Type Wattage [W] El Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-iu/h.sf.Fl Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] El Fenestration Used Name Glass Type No. of Glass SHGC VET Panes Conductance [Btu/b.sf.F] ASHULSgICIrAII User Defined 1 1.2500 0.8200 0.7600 ❑ Frm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu4b.F] Mat1187 No BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Matl265 Soil, I ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 4/27/2015 EnergyGauge Summit@ v4.10 5 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 A.0200 1.80 0.2900 ❑ 2IN, 105 Matll05 CONC BLK HW, 81N, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Matl269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sCF] [Btu/sCF] Density [lb/cf] RValue [h.st:FBtu] 1010 0.75 in. stucco, No No 0.08 11.22 50.24 11.9 ❑ 2"styro,8"CMU,lx2x24"oc airspace,0.5"gyp Layer Material Material Thickness Framing No. IN Factor 1 267 0.75" stucco 0.0625 0.000 ❑ 2 187 GYP ORPLASBOARD,1/2IN 0.0417 0.000 ❑ 3 215 POLYSTYRENE, EXP., 2IN, 0.1667 0.000 ❑ 4 105 CONC BLK HW, SIN, HOLLOW 0.6667 0.000 ❑ 5 256 WOOD, SOFT, 1-1/21N 0.1250 0.000 ❑ 4/27/2015 EnergyGauge Summit® A.10 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sEF] [lb/cf] [h.sEFBtu] 1011 518" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sal [lb/cf] [h.sl1F/Btu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sf.F] [Ib/cf] [h.sEFBtu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 4/27/2015 EnergyGauge Summit® v4.10