Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning S Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34962 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 15601 Midway Rd Sic Fair City / State / Zip: Fort Pierce, A 34945 Parcel #: 3201-133-0005-000/0 Zoning: I APPLICATION INFORMATION Permit Number: 1504-0389 Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Davis F Douglas Business Name: Richard K Davis Construction Corp Business Addr: P O Box 186 City / State / Zip: Fort Pierce, FI 34954-0186 REVIEW COMMENTS u sc Ownegv: 8N&I st Lucl •dpy�rty� coUnttr Jurisdiction: SAINT LUCIE COUNTY Lot#: Stories: REVIEWS AND COMMENTS Review Type Status Reviewed By DOCUMENTS MISSING PENDING Audrey Humphrey Block: Automatic Sprinkler System? No Fax Number: 772-465-7665 Email: Lnell@Rkdavis.Com Date Started Date Completed Date Released 4/21/2015 5/15/2015 Comment: VEG IN DRAWER (S) NO FEE ENVIRONMENTAL REVIEW COMPLETE Ben Salcer 5/15/2015 5/1512015 Comment: FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 4/21/2015 412112015 4/21/2015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 6/412015 6/4/2015 614/2015 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson Comment: PLEASE SHOW THAT AIR HANDLER UNITS ARE NOT IN WHAT IS CONSIDERED ATTIC SPACE IN 6/3/2015 ACCORDANCE WITH 503.2.7.6 OF THE 2010 FLORIDA ENERGY CODE PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 61312015 Comment: THIS BLDING WILL REQUIRE 4 WOMENS WATERCLOSETS,2 MENS WATERCLOSETSAND 2 MENS 6/3/2015 LAVITORIES AND 2 WOMENS LAVITORIES PER TABLE 403.1 FLORIDA BUD CODE PLUMBING 2010. Comment: PLEASE INDICATE THE LOCATION OF THE REQUIRED SERVICE SINK PER TABLE 403.1 FL BUD CODE 6/3/2015 PLUMBING 2010. 6/3/2015 Comment: IF OCCUPANT LOAD CHANGES FIXTURE REQUIREMENT WILL ALSO CHANGE ��irctP r�ocm � 'Q, Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fox:(772)462.6443 REVIEW COMMENTS PLANS EXAMINER REVIEW INCOMPLETE Joe Clclo 61312015 Comment: THE [3 ] SETS OF MANUFACTURERS PLANS [ VULCAN STEEL STRUCTURES ] MUST BE REVIEWED AND APPROVED BY PAUL WELCH P.E.[ METAL BUILDING ENGINEER HAS CLAIMED HIMSELF AS A SPECIALTY 6/3/2015 P.E. AND NOT THE PROJECT DESIGNER ] - ENGINEER OF RECORD [ PAUL WELCH ] TO MATCH THE VULCAN PLANS TO WELCH PLANS • NEED A NORTH ELEVATION • ROOF LINE OF EAST ELEVATION SHOULD MATCH UP WITH PARTITION ELEVATION AND WEST ELEVATION Comment: ST LUCIE COUNTY" DESIGN LOAD FOR COMPLIANCE SHEETS" MUST BE FILLED OUT CORRECTLY "THIS 6/3/2015 IS NOT A GROUP R OCCUPANCY' LINE 1 MUST STATE 2010 BUILDING CODE W/ 2012 SUPPLEMENTS' METAL BUILDING PLANS ARE DESIGNED AS A RISK CAT III WHICH IS CORRECT PER FBC TABLE 1604.5 / WIND LOAD SHEETS ARE RISK II' 613/2015 Comment: SUBMIT A SIGNED, DATED AND SEALED SOIL BORING TEST' MUST ACHIEVE 2500 P.S.F. Comment: PLAN SHEET S-1 ' MODIFY THE OCCUPANT LOAD CALCS IN TABLE OR SHOW ALL TABLES AND CHAIRS 6/3/2015 ON PLANS PER FBC TABLE 1004.1.1 • THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED' SQUARE FOOTAGE 6833 IS INCORRECT / SHOULD BE 7275 S.F. PLUS 850 S.F. GROUP B == 8125 S.F. TOTAL' Comment: ENGINEER OF RECORD [ PAUL WELCH ] TO SUBMIT AS.S.D. CALCULATION SHEET THAT THIS BUILDING 6/3/2015 CONFORMS TO BEING" ENCLOSED' PER ASCE7 CRITERIA [ NOT COMPLIANT WITH PARTIALLY ENCLOSED OR OPEN ] -THIS IS STATED ON WIND LOADS AND MANUFACTURERS BUILDING PLANS 6/3/2015 Comment: SUBMIT FIRE SPRINKLER PLANS W/ CRITERIA IN TRIPLICATE [ REQUIRED BY FBC 903.2.1.3 ] 6/4/2015 Comment: NOA # 14-0430.08 AS INDICATED ON THE PRODUCT AFFIDAVIT IS FOR S.M.I. WINDOWS" NEED LARGE MISSILE RATING WITHIN 30 FEET OF GRADE' FBC 1609.1.2' PLEASE MODIFY ALL DOCS AS NECESSARY 6/4/2015 Comment: PLEASE RETURN ORIGINAL PLANS IN TRIPLICATE W/ [ 2 ] PDF DISCS 6/4/2015 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE ZONING REVIEW INCOMPLETE Lydia Galbraith 4/23/2015 Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO THE ADJUSTMENT TO THE SITE PLAN NOT BEING APPROVED YET. THE PLANS WILL PROCEED THROUGH THE 4/23/2015 REVIEW PROCESS, HOWEVER, THE PERMIT WILL NOT BE ISSUED UNTIL SITE PLAN APPROVAL HAS BEEN RECEIVED AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE. Planning & Development Services Building 8. Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 SCANNED St. Luce Cou REVIEW COMMENTS ntv PROPERTY INFORMATION Address: 15601 Midway Rd Sic Fair City / State / Zip: Fort Pierce, FI 34945 Parcel #: 3201-133-0005-000/0 Zoning: I APPLICATION INFORMATION Permit Number: •--" na-- PermitType: BUILDING COMMERCIAL Contractor Name: Davis F Douglas Business Name: Richard K Davis Construction Business Addr: P O Box 186 City / State I Zip: Fort Pierce, FI 34954-0186 REVIEWS AND COMMENTS Review Tvoe Status DOCUMENTS MISSING PENDING 5/1512015 Comment: VEG IN DRAWER p ENVIRONMENTAL REVIEW COMPLETE Comment: FIRE DEPARTMENT REVIEW PENDING Comment: FRONT COUNTER REVIEW COMPLETE Comment: PLANS EXAMINER ELECTRIC COMPLETE Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Comment: PLEASE SHOW TH 6132015 ACCORDANCE WIT PLANS EXAMINER PLUMBING INCOMPLETE 6/32015 Comment: THIS SLIDING WILL LAVITORIES AND 2 6/3/2015 Comment: PLEASE INDICATE PLUMBING 2010. 6/32015 Comment: IF OCCUPANT LOA Owner(s): St Lucie County Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No 4 H .�� Fax Number: 772-465-7665 __v_�t9h__Yrv-e_�_-- ----- JUN 11 2015 _� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772]462.2172 Fax:(772)462.6443 REVIEW COMMENTS PLANS EXAMINER REVIEW INCOMPLETE Joe Ciclo 613/2015 Comment: THE [ 31 SETS OF MANUFACTURERS PLANS [ VULCAN STEEL STRUCTURES ] MUST BE REVIEWED AND APPROVED BY PAUL WELCH P.E.[ METAL BUILDING ENGINEER HAS CLAIMED HIMSELF AS A SPECIALTY P.E. 6/3/2015 AND NOT THE PROJECT DESIGNER ] • ENGINEER OF RECORD [ PAUL WELCH ] TO MATCH THE VULCAN PLANS TO WELCH PLANS' NEED A NORTH ELEVATION' ROOF LINE OF FAST ELEVATION SHOULD MATCH UP WITH PARTITION ELEVATION AND WEST ELEVATION Comment: PLAN SHEET S-1 . MODIFY THE OCCUPANT LOAD CALCS IN TABLE OR SHOW ALL TABLES AND CHAIRS ON 6/3/2015 PLANS PER FBC TABLE 1004.1.1 ' THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED • SQUARE FOOTAGE 6833 IS INCORRECT / SHOULD BE 7275 S.F. PLUS 850 S.F. GROUP B == 8125 S.F. TOTAL 6/3/2015 Comment: SUBMIT FIRE SPRINKLER PLANS W/ CRITERIA IN TRIPLICATE [ REQUIRED BY FBC 903.2.1.3 ] 6/4/2015 Comment: PLEASE RETURN ORIGINAL PLANS IN TRIPLICATE W/ [ 2 ] PDF DISCS 6/4/2015 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE ZONING REVIEW INCOMPLETE Lydia Galbraith 4/2312015 Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO THE ADJUSTMENT TO THE SITE PLAN NOT BEING APPROVED YET. THE PLANS WILL PROCEED THROUGH THE 4/2312015 REVIEW PROCESS, HOWEVER, THE PERMIT WILL NOT BE ISSUED UNTIL SITE PLAN APPROVAL HAS BEEN RECEIVED AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE.