HomeMy WebLinkAboutREVIEW COMMENTSPlanning S Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34962
Phone:(772)462.2172 Fax:(772)462.6443
PROPERTY INFORMATION
Address: 15601 Midway Rd Sic Fair
City / State / Zip: Fort Pierce, A 34945
Parcel #: 3201-133-0005-000/0
Zoning: I
APPLICATION INFORMATION
Permit Number: 1504-0389
Permit Type: BUILDING COMMERCIAL
CONTRACTOR INFORMATION
Contractor Name:
Davis F Douglas
Business Name:
Richard K Davis Construction Corp
Business Addr:
P O Box 186
City / State / Zip:
Fort Pierce, FI 34954-0186
REVIEW COMMENTS
u
sc
Ownegv: 8N&I
st Lucl •dpy�rty� coUnttr
Jurisdiction: SAINT LUCIE COUNTY
Lot#:
Stories:
REVIEWS AND COMMENTS
Review Type Status Reviewed By
DOCUMENTS MISSING PENDING Audrey Humphrey
Block:
Automatic Sprinkler System? No
Fax Number: 772-465-7665
Email: Lnell@Rkdavis.Com
Date Started Date Completed Date Released
4/21/2015
5/15/2015 Comment:
VEG IN DRAWER (S) NO FEE
ENVIRONMENTAL REVIEW
COMPLETE Ben Salcer 5/15/2015 5/1512015
Comment:
FIRE DEPARTMENT REVIEW
PENDING Tony Jerger
Comment:
FRONT COUNTER REVIEW
COMPLETE Audrey Humphrey 4/21/2015 412112015 4/21/2015
Comment:
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride 6/412015 6/4/2015 614/2015
Comment:
PLANS EXAMINER MECHANICAL
INCOMPLETE Carl Peterson
Comment:
PLEASE SHOW THAT AIR HANDLER UNITS ARE NOT IN WHAT IS CONSIDERED ATTIC SPACE IN
6/3/2015
ACCORDANCE WITH 503.2.7.6 OF THE 2010 FLORIDA ENERGY CODE
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 61312015
Comment:
THIS BLDING WILL REQUIRE 4 WOMENS WATERCLOSETS,2 MENS WATERCLOSETSAND 2 MENS
6/3/2015
LAVITORIES AND 2 WOMENS LAVITORIES PER TABLE 403.1 FLORIDA BUD CODE PLUMBING 2010.
Comment:
PLEASE INDICATE THE LOCATION OF THE REQUIRED SERVICE SINK PER TABLE 403.1 FL BUD CODE
6/3/2015
PLUMBING 2010.
6/3/2015 Comment:
IF OCCUPANT LOAD CHANGES FIXTURE REQUIREMENT WILL ALSO CHANGE
��irctP r�ocm � 'Q,
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 Fox:(772)462.6443
REVIEW COMMENTS
PLANS EXAMINER REVIEW
INCOMPLETE Joe Clclo 61312015
Comment:
THE [3 ] SETS OF MANUFACTURERS PLANS [ VULCAN STEEL STRUCTURES ] MUST BE REVIEWED AND
APPROVED BY PAUL WELCH P.E.[ METAL BUILDING ENGINEER HAS CLAIMED HIMSELF AS A SPECIALTY
6/3/2015
P.E. AND NOT THE PROJECT DESIGNER ] - ENGINEER OF RECORD [ PAUL WELCH ] TO MATCH THE
VULCAN PLANS TO WELCH PLANS • NEED A NORTH ELEVATION • ROOF LINE OF EAST ELEVATION
SHOULD MATCH UP WITH PARTITION ELEVATION AND WEST ELEVATION
Comment:
ST LUCIE COUNTY" DESIGN LOAD FOR COMPLIANCE SHEETS" MUST BE FILLED OUT CORRECTLY "THIS
6/3/2015
IS NOT A GROUP R OCCUPANCY' LINE 1 MUST STATE 2010 BUILDING CODE W/ 2012 SUPPLEMENTS'
METAL BUILDING PLANS ARE DESIGNED AS A RISK CAT III WHICH IS CORRECT PER FBC TABLE 1604.5 /
WIND LOAD SHEETS ARE RISK II'
613/2015 Comment:
SUBMIT A SIGNED, DATED AND SEALED SOIL BORING TEST' MUST ACHIEVE 2500 P.S.F.
Comment:
PLAN SHEET S-1 ' MODIFY THE OCCUPANT LOAD CALCS IN TABLE OR SHOW ALL TABLES AND CHAIRS
6/3/2015
ON PLANS PER FBC TABLE 1004.1.1 • THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED' SQUARE
FOOTAGE 6833 IS INCORRECT / SHOULD BE 7275 S.F. PLUS 850 S.F. GROUP B == 8125 S.F. TOTAL'
Comment:
ENGINEER OF RECORD [ PAUL WELCH ] TO SUBMIT AS.S.D. CALCULATION SHEET THAT THIS BUILDING
6/3/2015
CONFORMS TO BEING" ENCLOSED' PER ASCE7 CRITERIA [ NOT COMPLIANT WITH PARTIALLY ENCLOSED
OR OPEN ] -THIS IS STATED ON WIND LOADS AND MANUFACTURERS BUILDING PLANS
6/3/2015 Comment:
SUBMIT FIRE SPRINKLER PLANS W/ CRITERIA IN TRIPLICATE [ REQUIRED BY FBC 903.2.1.3 ]
6/4/2015 Comment:
NOA # 14-0430.08 AS INDICATED ON THE PRODUCT AFFIDAVIT IS FOR S.M.I. WINDOWS" NEED LARGE
MISSILE RATING WITHIN 30 FEET OF GRADE' FBC 1609.1.2' PLEASE MODIFY ALL DOCS AS NECESSARY
6/4/2015 Comment:
PLEASE RETURN ORIGINAL PLANS IN TRIPLICATE W/ [ 2 ] PDF DISCS
6/4/2015 Comment:
COMMENTS MAILED AND E-MAILED AS OF THIS DATE
ZONING REVIEW
INCOMPLETE Lydia Galbraith 4/23/2015
Comment:
PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO THE
ADJUSTMENT TO THE SITE PLAN NOT BEING APPROVED YET. THE PLANS WILL PROCEED THROUGH THE
4/23/2015
REVIEW PROCESS, HOWEVER, THE PERMIT WILL NOT BE ISSUED UNTIL SITE PLAN APPROVAL HAS BEEN
RECEIVED AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL
COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE.
Planning & Development Services
Building 8. Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 Fax:(772)462.6443
SCANNED
St. Luce Cou REVIEW COMMENTS
ntv
PROPERTY INFORMATION
Address: 15601 Midway Rd Sic Fair
City / State / Zip: Fort Pierce, FI 34945
Parcel #: 3201-133-0005-000/0
Zoning: I
APPLICATION INFORMATION
Permit Number: •--" na--
PermitType: BUILDING COMMERCIAL
Contractor Name:
Davis F Douglas
Business Name:
Richard K Davis Construction
Business Addr:
P O Box 186
City / State I Zip:
Fort Pierce, FI 34954-0186
REVIEWS AND COMMENTS
Review Tvoe
Status
DOCUMENTS MISSING
PENDING
5/1512015 Comment:
VEG IN DRAWER p
ENVIRONMENTAL REVIEW
COMPLETE
Comment:
FIRE DEPARTMENT REVIEW
PENDING
Comment:
FRONT COUNTER REVIEW
COMPLETE
Comment:
PLANS EXAMINER ELECTRIC
COMPLETE
Comment:
PLANS EXAMINER MECHANICAL
INCOMPLETE
Comment:
PLEASE SHOW TH
6132015
ACCORDANCE WIT
PLANS EXAMINER PLUMBING
INCOMPLETE
6/32015 Comment:
THIS SLIDING WILL
LAVITORIES AND 2
6/3/2015 Comment:
PLEASE INDICATE
PLUMBING 2010.
6/32015 Comment:
IF OCCUPANT LOA
Owner(s):
St Lucie County
Jurisdiction: SAINT LUCIE COUNTY
Lot#: Block:
Stories: Automatic Sprinkler System? No
4
H
.�� Fax Number: 772-465-7665
__v_�t9h__Yrv-e_�_-- -----
JUN 11 2015 _�
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772]462.2172 Fax:(772)462.6443
REVIEW COMMENTS
PLANS EXAMINER REVIEW
INCOMPLETE Joe Ciclo 613/2015
Comment:
THE [ 31 SETS OF MANUFACTURERS PLANS [ VULCAN STEEL STRUCTURES ] MUST BE REVIEWED AND
APPROVED BY PAUL WELCH P.E.[ METAL BUILDING ENGINEER HAS CLAIMED HIMSELF AS A SPECIALTY P.E.
6/3/2015
AND NOT THE PROJECT DESIGNER ] • ENGINEER OF RECORD [ PAUL WELCH ] TO MATCH THE VULCAN
PLANS TO WELCH PLANS' NEED A NORTH ELEVATION' ROOF LINE OF FAST ELEVATION SHOULD MATCH
UP WITH PARTITION ELEVATION AND WEST ELEVATION
Comment:
PLAN SHEET S-1 . MODIFY THE OCCUPANT LOAD CALCS IN TABLE OR SHOW ALL TABLES AND CHAIRS ON
6/3/2015
PLANS PER FBC TABLE 1004.1.1 ' THE 2012 F.F.P.C. IS CURRENTLY BEING ENFORCED • SQUARE FOOTAGE
6833 IS INCORRECT / SHOULD BE 7275 S.F. PLUS 850 S.F. GROUP B == 8125 S.F. TOTAL
6/3/2015 Comment:
SUBMIT FIRE SPRINKLER PLANS W/ CRITERIA IN TRIPLICATE [ REQUIRED BY FBC 903.2.1.3 ]
6/4/2015 Comment:
PLEASE RETURN ORIGINAL PLANS IN TRIPLICATE W/ [ 2 ] PDF DISCS
6/4/2015 Comment:
COMMENTS MAILED AND E-MAILED AS OF THIS DATE
ZONING REVIEW
INCOMPLETE Lydia Galbraith 4/2312015
Comment:
PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO THE
ADJUSTMENT TO THE SITE PLAN NOT BEING APPROVED YET. THE PLANS WILL PROCEED THROUGH THE
4/2312015
REVIEW PROCESS, HOWEVER, THE PERMIT WILL NOT BE ISSUED UNTIL SITE PLAN APPROVAL HAS BEEN
RECEIVED AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL
COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE.