Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEC r!' r� l3taR1 3+'� Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 SCANNtL Certification for Design Load Compliance BY Project Name: C t h I L-L° S I G w 5 St. Lucie Cnonr. Project Address: `o D 9 N 0 V� it U f 4w ` Permit#: Occupancy Type: Construction INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:. o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit , o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida V Code 2010 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed _open '7I 6 IJ 3. Risk Category: _I II _III _ IV Exposure Category: _B _C 4. Design Wind Velocity 16 S mph _ASD _LRFD End Zone Width: _D ft 5. Mean Roof Height "/A ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15''MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: - Zone 4: Id QS1 Zone 5: ,! Garage: 7. Design Loads: Floor: N!P N PSF Roof/Dead: i PSF Roof/Live: N A Balcony: PSF Dock:--�/_PSF Deck: -�—A PSF Stairs: 'd PSF Fence: PSF Railings: it A PSF 8. Were Shear Walls Considered For Structure? _Yes __&NotApplicable Explain Why Not: S, (� fJ 9. Is A Continuous Load Path Provided? _Yes _Not Applicable Explain Why Not: Si 6 Pl 10. Design Soil Bearing Pressure: Soil Test Reports Submitted? Yes ^L DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County, I AS certify that structural elements depicted on these plans provide adequate resistance to the design forces sd�cif, : II II VlcioR �•�1�R��21c922 Print Name Cent # & Co. Cent Auth. v Signature, Date and Seal _ �•J•�t��l �� �lL9 ILSSDC �( 90 �� 11 PFLF !RV� 9 Company Name &Address Revised 07/25/2014