HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEC
r!'
r� l3taR1 3+'�
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553
SCANNtL
Certification for Design Load Compliance BY
Project Name: C t h I L-L°
S I G w 5 St. Lucie Cnonr.
Project Address: `o D 9 N 0 V� it U f 4w `
Permit#: Occupancy Type: Construction
INSTRUCTIONS FOR USE:
This certification must be completed, signed, and sealed by the design professional of record.
Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:.
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit ,
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida V Code 2010 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed
_Partially Enclosed
_open '7I 6 IJ
3. Risk Category: _I II _III _ IV
Exposure Category: _B _C
4. Design Wind Velocity 16 S mph _ASD
_LRFD End Zone Width:
_D
ft
5. Mean Roof Height "/A ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15''MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: - Zone 4: Id QS1 Zone 5: ,! Garage:
7. Design Loads: Floor: N!P N PSF Roof/Dead: i PSF Roof/Live: N A Balcony: PSF
Dock:--�/_PSF Deck: -�—A PSF Stairs: 'd PSF Fence: PSF Railings: it A PSF
8. Were Shear Walls Considered For Structure? _Yes __&NotApplicable Explain Why Not: S, (� fJ
9. Is A Continuous Load Path Provided? _Yes _Not Applicable Explain Why Not: Si 6 Pl
10. Design Soil Bearing Pressure:
Soil Test Reports Submitted? Yes
^L DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County, I AS certify that structural elements depicted on these plans provide adequate resistance to the design
forces sd�cif, :
II II VlcioR �•�1�R��21c922
Print Name Cent # & Co. Cent Auth.
v
Signature, Date and Seal _ �•J•�t��l �� �lL9 ILSSDC �( 90 �� 11 PFLF !RV�
9 Company Name &Address