Loading...
HomeMy WebLinkAboutTRANSMITTAL PAPPERSE Civil Engineers SCANNED 469 N.W. Prima Vista Boulevard St Lucie County Port St. Lucie, Fl000p 34983 Phone - (772) 346-4990 Fax - (772) 340-7996 -currie@edc-inc.com TRANSMITTAL St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 15(3510aa5 Date June 15, 2015 EDC Job # 15-106 Re: 15838 Orange Ave Building Permit Resubmittal Enclosed are the following items via: I I U.S. Mail Overni ht Exp. I X I Courier IFAX Prints I X Plans Other: Copy of letter I Disks Other: Copies Date No. Description 3 06/15/15 1 Revised site plan These are transmitted as checked below: For approval For your use X As requested To keep on file Remarks: Released by: Received by: Signature Brad Currie Print Name Signature Print Name Date: June 15, 2015 Date: If enclosures are not as noted, kindly notify us at once. 2015-0E15 Ferta Te)_B]dg Permit Resubmittal 15-105 I RECEIycD JUN 15205 Address: City / State / Zip: Parcel #: S de REVIEW COMMENTS aka 15838 Orange Ave Fort Pierce, FI 34981 2212-500-0003-000/3 Page 1 Owner(s): Agricultural Ser Inter. Inc Jurisdiction: SAINT LUCIE COUNTY Zoning: IL Lot#: 1 APPLICATION INFORMATION Permit Number: 1505-0225 Stories: Permit Type: COMMERCIAL RENOVATION Block: Automatic Sprinkler System? No Contractor Name: Gregory F Sawyer Fax Number: 561-318-8517 Business Name: Ibis Building Corporation Email: Krystyal@lbisbuild.Com Business Addr: 1315 53Rd Street Suite 3 City / State / Zip: West Palm Beach, FI 33407 REVIEWS AND COMMENTS Review Tvoe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Audrey Humphrey 5/1512015 511512015 Comment: NOTICE OF COMMENCEMENT 6/1512016 Comment: NEEDS ONE MORE CID FOR FIRE DEPARTMENT. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 511512015 5/1512015 5116/2015 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 512612015 Comment: REQUESTING A FULL SET OF APPROVED ELECTRICAL PLANS,MUST SHOW ALL EXISTING ELECTRICAL,PANELS,SERVICE SIZE,INCLUDING VOLTAGE,AMPS,FAULT CURRENT,IS THE SERVICE 120/240 VOLT SINGLE OR 3 PHASE,120/208 VOLTS OR 2771480 VOLT 3 PHASE OR IS IT 1201240 DELTA 3 PHASE? 5/2612015 ALSO SHOW ALL PANELS AND PANEL FEEDERS WITH CONDUIT AND WIRE SIZE,ALL CONTROL PANELS,EM.SHUT DOW NS,ALL MFG.EQUIPMENT,ALL CLASS 1,DIV.1 OR 2 AREAS,ALL PANELS AND SERVICE EQUIPMENT TO BE IN DEDICATED AREA WITH SAFE ACCESS FOR QUILIFIED MAINT.PERSONEL ONLYALSO SHOW FIRE ALARM RACEWAYS.WAIT PRIDE SR. Comment: COMMENT ON ELECTRICAL,NUMBER 2,REQUESTING A LIST OF ALL MOTORS AND RATED 6/28/2015 HORSEPOWER,AMPS,VOLTAGE,PHASE,RESIN TANK HEATERS SIZES IN KILLOWATT,PHASE,VOLTAGE AND AMPS,TOTAL H.P.DEMAND.WALT PRIDE SR. PLANS EXAMINER MECHANICAL VOIDED Carl Peterson 6/2/2015 6/2/2015 6/212015 Comment: t- k P[ann[ngsoevelopmp!n. rvices. REVIEW COMMENTS Bo]Idhig $ Gode, Regu #6" 0(vIs1w 2300,VirgWaAvenue;. �Fort Pierce, I L,34982 .,�_. Rhone;t772j462.2172 Fax(772)1.152.6E43 Page 2 PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 5/27/2015 5/2712015 Comment: PLEASE LABEL ACCESSABLE RESTROOMS 5/27/2015 Comment: DOORS ARE NOT ALLOWED TO SWING INTO CLEAR FLOOR SPACE FOR ACCESSABLE PLUMBING FIXTURES PER SEC 603.2.3 FL ACC. CODE 2010 5/27/2015 Comment: PLEASE SHOW 5 FOOT TURNING RADIUS PER SEC 304 FL ACC. CODE 2010 5/27/2015 Comment: PLEASE SHOW SERVICE SINK PER TABLE403.1 FL PLUMBING CODE 2010 5/27/2015 Comment: PLEASE SHOW INSIDE DIMENSIONS FOR RESTROOMS PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 5/2712015 Comment: SUBMIT DESIGN FROM A FLORIDA LICENSED DESIGN PROFESSIONAL FOR THE CONTAINMENT AREA AND 5/27/2015 FOUNDATION FOR THE BULK RESIN STORAGE TANKS' FBC 414.5.5 AND 415.6.2.5 — GAVE RAY CHLADNY [ ARCHITECT ] [ 3 ] DESIGN LOAD COMPLIANCE SHEETS TO BE FILLED OUT 5/27/2015 Comment: CONTRACTOR TO CHANGE THE PERMIT APPLICATION UNDER DESIGNER / ENGINEER TO ADVANCED ARCHITECTURE AND PLANNING / RAYMOND CHLADNY Comment: FBC TABLE 602 REQUIRES 2 HOUR EXTERIOR WALL RATING FOR A TEXTERIOR WALL SEPARATION • 10' 5/27/2015 WALL SEPARATION REQUIRES 1 HOUR RATED WALL ASSEMBLIES' PLS MODIFY PLANS ACCORDINGLY AND PROVIDE PRODUCT APPROVAL FOR THE RATED OVERHEAD DOOR Comment: SHOW THE REQUIRED 30' SETBACK ON PLANS FROM THE PROPERTY LINE TO THE CONCRETE 5/2812015 PROTECTION AREA AND THE F.D. REQUIRED 10' SEPARATION FROM THE BUILDING TO THE CONTAINMENT AREA Comment SHOW THE VEHICLE PROTECTION LOADS ON PLANS PER FBC 1607.7.3 FOR THE TANK CONTAINMENT 5/28/2015 WALL AS A GUARD OR F.F.P.C. 60.1.2.13.1 AND 60.1.2.13.2 5/28/2015 Comment: SHOW ALL INTERIOR EQUIPMENT AND MACHINERY ON PLANS PER A-10 OF 12 `SHEET A-10 SHOWS A 110, CONVEYOR / DOES THIS FIT IN A LESSER SPACE AS SHOWN ON ARCHITECTS PLANS 5/2812015 Comment: ADDITIONAL COMMENTS MAY BE REQUIRED BY D.E.P. OR OTHER AGENCIES - 6/29/2016 Comment: ADDITIONAL COMMENTS MAY BE REQUIRED BY THE MECHANICAL PLAN REVIEWER 5/29/2015 Comment: COMMENTS E-MAILED AS OF THIS DATE — UPON RE -SUBMITTAL WE WILL NEED [ 3 ] SETS OF S.S.D. ORIGINAL PLANS W/ [2] P.D.F. DISCS — ZONING REVIEW INCOMPLETE Lydia Galbraith 5/18/2015 511912015 Comment: PLEASE PROVIDE A LETTER FROM HEALTH DEP. THAT SEPTIC IS IN WORKING CONDITION. 5/1912015 Comment: PLEASE PROVIDE A PLAN INDICATING ALL PARKING SPACES ARE ACCESSIBLE (TURN RADIUS). 5/19/2015 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER AND THE ENVIRONMENTAL DEPARTMENT MIGHT HAVE ADDITIONAL COMMENTS. SCANNED St. LucBy ie County To EDC Civil Enaineers St. Lucie Count Joe 2300 Virginia Avenue Fort Pierce, FL 34982 469 N.W. Prima Vista Boulevard Port St. Lucie, Florida 34983 Phone - (772) 340-4990 Fax — (772) 340-7996 bridcurrie@edc-inc.com TRANSMITTAL Date June 25, 2015 EDC Job # 15-105 Re: Ferra Tex Plan Review Enclosed are the following items via: I I U.S. Mail I I Overnight Exp. I X I Courier 1FAX Prints I X Plans Other: Copy of letter I Disks Other: Copies Date No. Description 4 06/25/15 1 Signed & Sealed Site Plan These are transmitted as checked below: For approval I I For your use I X I As requested I I To keep on file Remarks: Released by: Date: June 5 2015 Signature Patricia Sesta Print Name Received by: Date: Signature Print Name If enclosures are not as noted, kindly notify us at once. 20154)625 SLC Plan Review Tmnsmi9 1-1 5-105 ' y v Planning anti Development Services Department Planning Division MEMORANDUM TO: Edmund Bas, Engineering FROM: Lydia Galbraith, Planning & Development Services, Planning PtO26 DATE: 06/26/2015 SUBJECT: Parking, 15838 ORANGE AVE. Ferratex, permit 1505-0225 Please review the proposed parking. The parking will receive a WDA for time frame construction.