TRANSMITTAL
St. Lucie County Building Department
2300 Virginia Avenue
Fort Pierce, FL 34982
15(3510aa5
Date
June 15, 2015
EDC Job #
15-106
Re:
15838 Orange Ave
Building Permit Resubmittal
Enclosed are the following items via: I I U.S. Mail Overni ht Exp. I X I Courier IFAX
Prints I X Plans Other:
Copy of letter I Disks Other:
Copies
Date
No.
Description
3
06/15/15
1
Revised site plan
These are transmitted as checked below:
For approval For your use X As requested To keep on file
Remarks:
Released by:
Received by:
Signature
Brad Currie
Print Name
Signature
Print Name
Date: June 15, 2015
Date:
If enclosures are not as noted, kindly notify us at once.
2015-0E15 Ferta Te)_B]dg Permit Resubmittal 15-105
I RECEIycD JUN 15205
Address:
City / State / Zip:
Parcel #:
S
de
REVIEW COMMENTS
aka
15838 Orange Ave
Fort Pierce, FI 34981
2212-500-0003-000/3
Page 1
Owner(s):
Agricultural Ser Inter. Inc
Jurisdiction: SAINT LUCIE COUNTY
Zoning: IL Lot#: 1
APPLICATION INFORMATION
Permit Number: 1505-0225 Stories:
Permit Type: COMMERCIAL RENOVATION
Block:
Automatic Sprinkler System? No
Contractor Name:
Gregory F Sawyer Fax Number: 561-318-8517
Business Name:
Ibis Building
Corporation
Email: Krystyal@lbisbuild.Com
Business Addr:
1315 53Rd Street Suite 3
City / State / Zip:
West Palm Beach, FI 33407
REVIEWS AND COMMENTS
Review Tvoe
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Audrey Humphrey 5/1512015
511512015
Comment:
NOTICE OF COMMENCEMENT
6/1512016
Comment:
NEEDS ONE MORE CID FOR FIRE DEPARTMENT.
FIRE DEPARTMENT REVIEW
PENDING Tony Jerger
Comment:
FRONT COUNTER REVIEW
COMPLETE Audrey Humphrey 511512015 5/1512015 5116/2015
Comment:
PLANS EXAMINER ELECTRIC
INCOMPLETE Walter Pride 512612015
Comment:
REQUESTING A FULL SET OF APPROVED ELECTRICAL PLANS,MUST SHOW ALL EXISTING
ELECTRICAL,PANELS,SERVICE SIZE,INCLUDING VOLTAGE,AMPS,FAULT CURRENT,IS THE SERVICE 120/240
VOLT SINGLE OR 3 PHASE,120/208 VOLTS OR 2771480 VOLT 3 PHASE OR IS IT 1201240 DELTA 3 PHASE?
5/2612015
ALSO SHOW ALL PANELS AND PANEL FEEDERS WITH CONDUIT AND WIRE SIZE,ALL CONTROL
PANELS,EM.SHUT DOW NS,ALL MFG.EQUIPMENT,ALL CLASS 1,DIV.1 OR 2 AREAS,ALL PANELS AND SERVICE
EQUIPMENT TO BE IN DEDICATED AREA WITH SAFE ACCESS FOR QUILIFIED MAINT.PERSONEL ONLYALSO
SHOW FIRE ALARM RACEWAYS.WAIT PRIDE SR.
Comment:
COMMENT ON ELECTRICAL,NUMBER 2,REQUESTING A LIST OF ALL MOTORS AND RATED
6/28/2015
HORSEPOWER,AMPS,VOLTAGE,PHASE,RESIN TANK HEATERS SIZES IN KILLOWATT,PHASE,VOLTAGE AND
AMPS,TOTAL H.P.DEMAND.WALT PRIDE SR.
PLANS EXAMINER MECHANICAL
VOIDED Carl Peterson 6/2/2015 6/2/2015 6/212015
Comment:
t-
k
P[ann[ngsoevelopmp!n. rvices. REVIEW COMMENTS
Bo]Idhig $ Gode, Regu #6" 0(vIs1w
2300,VirgWaAvenue;.
�Fort Pierce, I L,34982 .,�_.
Rhone;t772j462.2172 Fax(772)1.152.6E43
Page 2
PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 5/27/2015
5/2712015 Comment: PLEASE LABEL ACCESSABLE RESTROOMS
5/27/2015 Comment: DOORS ARE NOT ALLOWED TO SWING INTO CLEAR FLOOR SPACE FOR ACCESSABLE PLUMBING
FIXTURES PER SEC 603.2.3 FL ACC. CODE 2010
5/27/2015 Comment: PLEASE SHOW 5 FOOT TURNING RADIUS PER SEC 304 FL ACC. CODE 2010
5/27/2015 Comment: PLEASE SHOW SERVICE SINK PER TABLE403.1 FL PLUMBING CODE 2010
5/27/2015
Comment:
PLEASE SHOW INSIDE DIMENSIONS FOR RESTROOMS
PLANS EXAMINER REVIEW
INCOMPLETE Joe Cicio 5/2712015
Comment:
SUBMIT DESIGN FROM A FLORIDA LICENSED DESIGN PROFESSIONAL FOR THE CONTAINMENT AREA AND
5/27/2015
FOUNDATION FOR THE BULK RESIN STORAGE TANKS' FBC 414.5.5 AND 415.6.2.5 — GAVE RAY CHLADNY [
ARCHITECT ] [ 3 ] DESIGN LOAD COMPLIANCE SHEETS TO BE FILLED OUT
5/27/2015
Comment:
CONTRACTOR TO CHANGE THE PERMIT APPLICATION UNDER DESIGNER / ENGINEER TO ADVANCED
ARCHITECTURE AND PLANNING / RAYMOND CHLADNY
Comment:
FBC TABLE 602 REQUIRES 2 HOUR EXTERIOR WALL RATING FOR A TEXTERIOR WALL SEPARATION • 10'
5/27/2015
WALL SEPARATION REQUIRES 1 HOUR RATED WALL ASSEMBLIES' PLS MODIFY PLANS ACCORDINGLY
AND PROVIDE PRODUCT APPROVAL FOR THE RATED OVERHEAD DOOR
Comment:
SHOW THE REQUIRED 30' SETBACK ON PLANS FROM THE PROPERTY LINE TO THE CONCRETE
5/2812015
PROTECTION AREA AND THE F.D. REQUIRED 10' SEPARATION FROM THE BUILDING TO THE CONTAINMENT
AREA
Comment
SHOW THE VEHICLE PROTECTION LOADS ON PLANS PER FBC 1607.7.3 FOR THE TANK CONTAINMENT
5/28/2015
WALL AS A GUARD OR F.F.P.C. 60.1.2.13.1 AND 60.1.2.13.2
5/28/2015
Comment:
SHOW ALL INTERIOR EQUIPMENT AND MACHINERY ON PLANS PER A-10 OF 12 `SHEET A-10 SHOWS A 110,
CONVEYOR / DOES THIS FIT IN A LESSER SPACE AS SHOWN ON ARCHITECTS PLANS
5/2812015
Comment:
ADDITIONAL COMMENTS MAY BE REQUIRED BY D.E.P. OR OTHER AGENCIES -
6/29/2016
Comment:
ADDITIONAL COMMENTS MAY BE REQUIRED BY THE MECHANICAL PLAN REVIEWER
5/29/2015
Comment:
COMMENTS E-MAILED AS OF THIS DATE — UPON RE -SUBMITTAL WE WILL NEED [ 3 ] SETS OF S.S.D.
ORIGINAL PLANS W/ [2] P.D.F. DISCS —
ZONING REVIEW
INCOMPLETE Lydia Galbraith 5/18/2015
511912015
Comment:
PLEASE PROVIDE A LETTER FROM HEALTH DEP. THAT SEPTIC IS IN WORKING CONDITION.
5/1912015
Comment:
PLEASE PROVIDE A PLAN INDICATING ALL PARKING SPACES ARE ACCESSIBLE (TURN RADIUS).
5/19/2015
Comment:
PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
EXAMINER AND THE ENVIRONMENTAL DEPARTMENT MIGHT HAVE ADDITIONAL COMMENTS.
SCANNED
St. LucBy
ie County
To
EDC
Civil Enaineers
St. Lucie Count
Joe
2300 Virginia Avenue
Fort Pierce, FL 34982
469 N.W. Prima Vista Boulevard
Port St. Lucie, Florida 34983
Phone - (772) 340-4990 Fax — (772) 340-7996
bridcurrie@edc-inc.com
TRANSMITTAL
Date
June 25, 2015
EDC Job #
15-105
Re:
Ferra Tex
Plan Review
Enclosed are the following items via: I I U.S. Mail I I Overnight Exp. I X I Courier 1FAX
Prints I X Plans Other:
Copy of letter I Disks Other:
Copies
Date
No.
Description
4
06/25/15
1
Signed & Sealed Site Plan
These are transmitted as checked below:
For approval I I For your use I X I As requested I I To keep on file
Remarks:
Released by: Date: June 5 2015
Signature
Patricia Sesta
Print Name
Received by: Date:
Signature
Print Name
If enclosures are not as noted, kindly notify us at once.
20154)625 SLC Plan Review Tmnsmi9 1-1 5-105 '
y
v
Planning anti Development
Services Department
Planning Division
MEMORANDUM
TO: Edmund Bas, Engineering
FROM: Lydia Galbraith, Planning & Development Services, Planning PtO26
DATE: 06/26/2015
SUBJECT: Parking, 15838 ORANGE AVE. Ferratex, permit 1505-0225
Please review the proposed parking. The parking will receive a WDA for time frame construction.