HomeMy WebLinkAboutDESIGN CALCULATIONSea S
r% easyseals.com
ol
SCANNED
BY
Si. Lucie Countv
DESIGN CALCULATIONS
FOR
SANDPIPER'PLAZA
3' x 10' CABINETS
10760 S. US Hwy 1— Port St Lucie
GENERAL NOTES:
1. Design is in accordance with the 2010 Florida Building Code for use within
and outside the High Velocity Hurricane Zone (HVHZ).
2. Wind loads have been calculated per the requirements of ASCE 7-10 as
shown herein.
3. These engineering calculations pertain only to the structural integrity of
those systems, components, and/or other construction explicitly specified
herein and/or in accompanying engineering drawings. The existing host
structure (if any) must be capable of supporting the loaded system as
verified by building department or architect / engineer of record. No
warranty, either expressed or implied, is contained herein.
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
5. Where site conditions deviate from those noted herein, revisions may be
required or a separate site -specific engineering evaluation performed.
6. Aluminum components in contact with steel or embedded in concrete shall
be protected as prescribed in the 2005 Aluminum Design Manual, Part 1A.
Steel components in contact with, but not encased in, concrete shall be
coated, painted, or otherwise protected against corrosion.
7. Engineer seal affixed hereto validates structural design as shown only. Use
of this specification by contractor, et. Al, indemnifies and saves harmless
this engineer for all costs & damages including legal fees & apellate;fees
resulting from deviation from this design.
index:
Pg 1
Cover
Pg2
Wind Loads
Pg 3
Anchor Design
�pnu„rh4..
Engineer's signature anq seal valid
�.fcjj-ages' 1'throu
.-35'e STATE, F ,Cc
Christjan;LaUtigle ' %1 P.E # 67382
Easy SealSrn, n Cdr'l! Auth # 29531
1200 N Federal Hwy, #200
Boca Raton, FL33432 Easy SeQLS.com Page 1
V
ASCE 7-10 Design Wind Loads
WALL -MOUNTED SIGNS
Building Specs
V = 165 mph
Exposure C
Calculations
a = 9.5
zg = 900'
Gcpi = 0
Basic wind speed
3-sec gust speed power law exponent
Nominal ht. of atmos. boundary layer
Internal pressure coeff
CALCULATIONS FOR WALL -MOUNTED SIGNS
ASD Load Combo Coeff: 0.6
Kd= 0.85 Directionalityfactor
Kzt = 1.0 Topographic factor
A = 10 sq ft Tributary area
165
WALL
mph - Exp "C"
-MOUNTED SIGNS
ASD WIND PRESSURES
SIGN
CENTER
CORNER
]EIGHT
(Zone 4)
(Zone 5)
Y
%
u v
u
Y
0.85
50.3
tD
-1.10
U
-1.40
15 ft
33.2 psf 42.2 psf
20 ft
35.3 psf
44.9 psf
0.90
53.4
-1.10
-1.40
25 It
37.0 psf
47.0 psf
0.95
56.0
-1.10
-1.40
30 ft
38.4 psf
48.9 psf
0.98
58.2
-1.10
-1.40
35 ft
39.7 psf
50.5 psf
1.01
60.1
-1.10
-1.40
40 ft
40.8 psf
51.9 psf
1.04
61.8
-1.10-1.40
45 ft
41.8 psf
53.2 psf
1.07
63.4
-1.10
-1.40
Soft
42.8 psf
54.4 psf
1.09
64.8
-1.10
-1.40
55 ft
43.6 psf
55.5 psf
1.12
66.1
-1.10
-1.40
60 ft
44.4 psf
56.6 psf
1.14
67.3
-1.10
-1.40
70 ft
37.6 psf
75.1 psf
1.17
69.6
-0.90
-1.80
80 ft
38.6 psf
77.3 psf
1.21
71.5
-0.90
-1.80
90 ft
39.6 psf
79.2 psf
1.24
73.3
-0.90
-1.80
100 ft
40.5 psf
81.0 psf
1.27
75.0
-0.90
-1.80
110 ft
41.3 psf
82.6 psf
1.29
76.5
-0.90
-1.80
120 ft
42.1 psf
84.1 psf
1.32
77.9
-0.90
-1.80
130 ft
42.8 psf
85.6 psf
1.34
79.2
-0.90
-1.80
140 ft
43.5 psf
86.9 psf
1.36
80.5
-0.90
-1.80
150 ft
44.1 psf
88.2 psf
1.38
81.7
-0.90
-1.80
175 ft
45.6 psf
91.1 psf
1.42
84.4
-0.90
-1.80
200 ft
46.8 psf
93.7 psf
1.46
86.8
-0.90
: 1.80
250 ft
49.1 osf
98.2 osf
1.53
90.9
-0.90
-1.80
Page 2
CALCULATIONS FOR WALL -MOUNTED SIGNS
ea*�=
Wall Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure: P = 48.9 psf
Sign type: Cabinet
Sign size: A = 30.0 sqft (entire cabinet)
Wall material: Wood cox or equiv, thickness to match Min Embed
Anchor type/size: 3/8" Bolt+Nut
Ref: AAMATIR-A9-1991
Min Embedment: Full
Min edge dist: 1.5" Min Spacing: 1.5" 1
Anchor tensile capacity: Tcap = 312.5 lb (per anchor)
I
Check Anchors for Pullout
Total Reaction:
Rt=
1466
lb ... =P*A
(entire cabinet)
No. of anchors req'd:
n =
4.7
total anchors
...=.Rt/Tcap
Total anchors required: 5 total anchors balanced over cabinet
OK, use min (3) attachments at top & bottom = (6) total.
Page 3