Loading...
HomeMy WebLinkAboutDESIGN CALCULATIONSea S r% easyseals.com ol SCANNED BY Si. Lucie Countv DESIGN CALCULATIONS FOR SANDPIPER'PLAZA 3' x 10' CABINETS 10760 S. US Hwy 1— Port St Lucie GENERAL NOTES: 1. Design is in accordance with the 2010 Florida Building Code for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host structure (if any) must be capable of supporting the loaded system as verified by building department or architect / engineer of record. No warranty, either expressed or implied, is contained herein. 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2005 Aluminum Design Manual, Part 1A. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate;fees resulting from deviation from this design. index: Pg 1 Cover Pg2 Wind Loads Pg 3 Anchor Design �pnu„rh4.. Engineer's signature anq seal valid �.fcjj-ages' 1'throu .-35'e STATE, F ,Cc Christjan;LaUtigle ' %1 P.E # 67382 Easy SealSrn, n Cdr'l! Auth # 29531 1200 N Federal Hwy, #200 Boca Raton, FL33432 Easy SeQLS.com Page 1 V ASCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V = 165 mph Exposure C Calculations a = 9.5 zg = 900' Gcpi = 0 Basic wind speed 3-sec gust speed power law exponent Nominal ht. of atmos. boundary layer Internal pressure coeff CALCULATIONS FOR WALL -MOUNTED SIGNS ASD Load Combo Coeff: 0.6 Kd= 0.85 Directionalityfactor Kzt = 1.0 Topographic factor A = 10 sq ft Tributary area 165 WALL mph - Exp "C" -MOUNTED SIGNS ASD WIND PRESSURES SIGN CENTER CORNER ]EIGHT (Zone 4) (Zone 5) Y % u v u Y 0.85 50.3 tD -1.10 U -1.40 15 ft 33.2 psf 42.2 psf 20 ft 35.3 psf 44.9 psf 0.90 53.4 -1.10 -1.40 25 It 37.0 psf 47.0 psf 0.95 56.0 -1.10 -1.40 30 ft 38.4 psf 48.9 psf 0.98 58.2 -1.10 -1.40 35 ft 39.7 psf 50.5 psf 1.01 60.1 -1.10 -1.40 40 ft 40.8 psf 51.9 psf 1.04 61.8 -1.10-1.40 45 ft 41.8 psf 53.2 psf 1.07 63.4 -1.10 -1.40 Soft 42.8 psf 54.4 psf 1.09 64.8 -1.10 -1.40 55 ft 43.6 psf 55.5 psf 1.12 66.1 -1.10 -1.40 60 ft 44.4 psf 56.6 psf 1.14 67.3 -1.10 -1.40 70 ft 37.6 psf 75.1 psf 1.17 69.6 -0.90 -1.80 80 ft 38.6 psf 77.3 psf 1.21 71.5 -0.90 -1.80 90 ft 39.6 psf 79.2 psf 1.24 73.3 -0.90 -1.80 100 ft 40.5 psf 81.0 psf 1.27 75.0 -0.90 -1.80 110 ft 41.3 psf 82.6 psf 1.29 76.5 -0.90 -1.80 120 ft 42.1 psf 84.1 psf 1.32 77.9 -0.90 -1.80 130 ft 42.8 psf 85.6 psf 1.34 79.2 -0.90 -1.80 140 ft 43.5 psf 86.9 psf 1.36 80.5 -0.90 -1.80 150 ft 44.1 psf 88.2 psf 1.38 81.7 -0.90 -1.80 175 ft 45.6 psf 91.1 psf 1.42 84.4 -0.90 -1.80 200 ft 46.8 psf 93.7 psf 1.46 86.8 -0.90 : 1.80 250 ft 49.1 osf 98.2 osf 1.53 90.9 -0.90 -1.80 Page 2 CALCULATIONS FOR WALL -MOUNTED SIGNS ea*�= Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: P = 48.9 psf Sign type: Cabinet Sign size: A = 30.0 sqft (entire cabinet) Wall material: Wood cox or equiv, thickness to match Min Embed Anchor type/size: 3/8" Bolt+Nut Ref: AAMATIR-A9-1991 Min Embedment: Full Min edge dist: 1.5" Min Spacing: 1.5" 1 Anchor tensile capacity: Tcap = 312.5 lb (per anchor) I Check Anchors for Pullout Total Reaction: Rt= 1466 lb ... =P*A (entire cabinet) No. of anchors req'd: n = 4.7 total anchors ...=.Rt/Tcap Total anchors required: 5 total anchors balanced over cabinet OK, use min (3) attachments at top & bottom = (6) total. Page 3