HomeMy WebLinkAboutDESIGN CALCULATIONSeasyseals.com
DESIGN CALCULATIONS
FOR
SANDPIPER PLAZA
3' x 1®' CABINETS
10760 S. US Hwy 1— Port St Lucie
GENERAL NOTES:
1. Design is in accordance with the 2010 Florida Building Code for use within
and outside the High Velocity Hurricane Zone (HVHZ).
2. Wind loads have been calculated per the requirements of ASCE 7-10 as
shown herein.
3. These engineering calculations pertain only to the structural integrity of
those systems, components, and/or other construction explicitly specified
herein and/or in accompanying engineering drawings. The existing host
structure (if any) must be capable of supporting the loaded system as
verified by building department or architect / engineer of record. No
warranty, either expressed or implied, is contained herein.
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
S. Where site conditions deviate from those noted herein, revisions may be
required or a separate site -specific engineering evaluation performed.
6. Aluminum components in contact with steel or embedded in concrete shall
be protected as prescribed in the 2005 Aluminum Design Manual, Part 1A.
Steel components in contact with, but not encased in, concrete shall be
coated, painted, or otherwise protected against corrosion.
7. Engineer seal affixed hereto validates structural design as shown only. Use
of this specification by contractor, et. Al, indemnifies and saves harmless
this engineer for all costs & damages including legal fees & apellate fees
resulting from deviation from this design.
SCANNED
BY
St. Lucie Countv
Index:
Pg 1 Cover
Pg 2 Wind Loads
Pg 3 Anchor Design
5,.,,nu,,,,,.
Engineer,'s signature and seal valid
f , ges:1: the g?h7,
No. 67332
i3'. iATE ty�
O a 2v
Christian�L•an gley' ,Ua'�,P. E # 67382
UN A
Easy Seals,,,,,,, Cdr�Auth # 29531
Federal
3432azoo EasySeals.com Page 1
Bocaoca Raton, FL 33432
_.; Seals
1: - �- ea wlwcm
ASCE 7-10 Design Wind Lads
WALL -MOUNTED SIGNS
Building Specs
V= 165mph
Exposure C
Calculations
a = 9.5
zg = 900,
Gcpi = 0
Basic wind speed
3-sec gust speed power law exponent
Nominal ht. of otmos. boundary layer
Internal pressure coeff
CALCULATIONS FOR WALL -(MOUNTED SIGNS
ASD Load Combo Coeff: 0.6
Kd = 0.85 Directionality factor
Kzt = 1.0 Topographic factor
A = 10 sq ft Tributary area
165 mph - Exp "C"
WALL -MOUNTED SIGNS
ASD WIND PRESSURES
SIGN
CENTER
CORNER
HEIGHT
(Zone 4)
(Zone 5)
I
N
Y Y
qz
15 ft
33.2 psf
42.2 psf
0.95
50.3
-1 10
-1.10
20 ft
35.3 psf
44.9 psf
090
53.4
1 10
1 40
25 ft
37.0 psf
47.0 psf
0.95
56.0
-1.10
; 40
30 ft
38.4 psf
48.9 psf
0.98
58.2
1 to
1 40
35 ft
39.7 psf
50.5 psf
1.01
60.1
-1 10
-1.40
40 ft
40.8 psf
51.9 psf
1.04
61.8
1.10
1.40
45 ft
41.8 psf
53.2 psf
107
63.4
-1 10
-1.40
50 ft
42.8 psf
54.4 psf
109
64.8
1 10
-1 110
55 ft
43.6 psf
55.5 psf
1 12
66.1
-1.10
-1.40
60 ft
44.4 psf
56.6 psf
1.14
67.3
-1.10
-1.40
70 ft
37.6 psf :
75.1 psf
1.17
69.6
-0.90
-1 80
80 ft
38.6 psf
77.3 psf
1 ' 1
71.5
0 90
-1 RO
90 ft
39.6 psf
79.2 psf
1 21
73.3
0.90
-1 30
100 ft
40.5 psf
81.0 psf
1.27
75.0
0.90
-1.80
110 ft
41.3 psf
82.6 psf
1 29
76.5
-0.90
-1.80
120 ft
42.1 psf
84.1 psf
132
77.9
0.90
180
130 ft
42.8 psf
85.6 psf
1.34
79.2
-0.90
-1.80
140 ft
43.5 psf
86.9 psf
1 36
80.5
0.90
1 PO
150 ft
4.1 psf
88.2 psf
1. 3�;
81.7
0.90
-1.80
175 ft
5.6 psf
91.1 psf
1. 4-184.4
-0 90
1 80
200 ft
6.8 psf
[49.1
93.7 psf
1,10
86.8
-0.90
-1 80
250 ft
psf,
98.2 psf-
1 5 :
90.9
0 90
180
Page 2
CALCULATIONS l' OR WALL -MOUNTED SIGNS
Wall Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure: P = 48.9 psf
Sign type: Cabinet
Sign size: A = 30.0 sgft (entire cabinet)
Wall material: Wood CDX or equiv, thickness to match Min Embed
Anchor type/size: 3/8" Bolt+ Nut
Ref: AAMATIR-A9-1991
Min Embedment: Full
Min edge dist: 1.5" Min Spacing: 1.5"
Anchor tensile capacity: Tcap = 312.5 lb (per anchor)
Check Anchors for Pullout
Total Reaction: Rt= 1466 lb ... =P*A (entire cabinet)
No. of anchors req'd: n = 4.7 total anchors ... =Rt/Tcap
Total anchors required: 5 total anchors balanced over cabinet
OK, use min (3) attachments at top & bottom = (6) total.
Page 3