HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOADPlanning & Development Services Department
° Building & Code Regulations Division SCANNED
— — — 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 BY
St. Lucie County
Certification for Design Load Compliance
Project Name:)001, 0Li0➢ CA WhSH
Project Address: _ > r 000 F Eft W �z h? S I Lw4k C OY16 S
Permit#: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida I/ Code 2010 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed _Partially Enclosed _Open S�
3. Risk Category: _I .V II III _IV Exposure Category: _B _C _D
4. Design Wind Velocity 6J mph _ASD _LRFD End Zone Width: ft
S. Mean Roof Height V ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings)
Zone 1: Zone 2: Zone 3: Zone 4: 10?5S Zone 5: Garage:
7. Design Loappds: Floor: 4 R PSF Roof/Dead: 00d PSF Roof/Ugve: h BalcN ony: A PSF
Dock: tJ /� PSF Deck: N/A PSF Stairs:- � h PSF Fence: '� I1 PSF Railings: !1 A PSF
8. Were Shear Walls Considered For Structure? _Yes _Not Applicable Explain Why Not: I S I6 n1
9. Is A Continuous Load Path Provided? _Yes _Not Applicable Explain Why Not: 7l N?�
10. Design Soil Bearing Pressure: N A, PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these ppplans provide adequate resistance to the design
forces specifi d: 11 CY tq � 1 . E,,1 4114 Ze
Print Name Cert # & Co. Cert Auth.
u
/R
Signature, Date, and Seal J.1 • �neRik`( A�j
Company Name & Address Y9J�
Revised 07/25/2014 7 MAY 2 2 2015