Loading...
HomeMy WebLinkAboutDESIGN CALCULATION=� easyseals.com SCANNED By Sit Lug County DESIGN CALCULATIONS FOR SANDPIPER PLAZA 3' x 10' CABINETS 10760 S. US Hwy 1— Port St Lucie GENERAL NOTES: 1. Design is in accordance with the 2010 Florida Building Code for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host Index: structure (if any) must be capable of supporting the loaded system as Pg 1 Cover verified by building department or architect / engineer of record. No Pg 2 Wind Loads warranty, either expressed or implied, is contained herein. Pg 3 Anchor Design 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. S. Where site conditions deviate from those noted herein, revisions may be s sig a ure i Enginee s sigrLature and seal valid required or a separate site -specific engineering evaluation performed. �.for.�iages' rourou�tri�� 6. Aluminum components in contact with steel or embedded in concrete shall 'L be protected as prescribed in the 2005 Aluminum Design Manual, Part 1A. No. 67312 ' Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. _ 92: 7. Engineer seal affixed hereto validates structural design as shown only. Use =°°° STP PE of = °. �,M of this specification by contractor, et. Al, indemnifiesand saves harmless .._07� this engineer for all costs & damages including legal fees & apellate fees Christ7Ta%Lta�ngiFy- J� �',P,E # 67382 resulting from deviation from this design. Easy th # 29531 BocaaFederal3432#200 Ea ySealls.com Page 1 Boca Raton, FL 33432 1 -Seal ASCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V = 165 mph Basic wind speed Exposure C Calculations a=9.5 3-sec gust speed power law exponent zg = 900' Nominal ht. of atmos. boundary layer Gcpi = 0 Internal pressure coeff 165 ph--: Exp "C" WALL -MOUNTED SIGNS ASD WIND PRESSURES SIGN CENTER CORNER HEIGHT (Zone 4) (Zone 5) 15 ft 33.2 psf 42.2 psf 20 ft 35.3 psf 44.9 psf 25 ft 37.0 psf 47.0 psf 30 ft 38.4 psf 48.9 psf 35 ft 39.7 psf 50.5 psf 40 ft 40.8 psf 51.9 psf 45 ft 41.8 psf 53.2 psf 50 ft 42.8 psf 54.4 psf 55 ft 43.6 psf 55.5 psf 60 ft 44.4 psf 56.6 psf 70 ft 37.6 psf 75.1 psf 80 ft 38.6 psf 77.3 psf 90 ft 39.6 psf 79.2 psf 100 ft 40.5 psf 81.0 psf 110 ft 41.3 psf 82.6 psf 120 ft 42.1 psf 84.1 psf 130 ft 42.8 psf 85.6 psf 140 ft 43.5 psf 86.9 psf 150 ft 44.1 psf 88.2 psf 175 ft 45.6 psf 91.1 psf 200 ft 46.8 psf 93.7 psf 250 ft 49.1 psf 98.2 psf CAL'CULATIONS I _' t WALL -MOUNTED SIGNS ASD Load Combo Coeff: 0.6 Kd = 0.85 Directionalityfactor Kzt= 1.0 Topographicfactor A = 30 sq ft Tributary area Y Y qi a L V n � n 0.85 50.3 -1.10 -1.40 0.90 53.4 -1.10 -1.40 0.95 56.0 -1.10 -1.40 0.98 58.2 -1.10 -1.40 1.01 60.1 -1.10 -1.40 1.04 61.8 -1.10 -1.40 1.07 63.4 -1.10 -1.40 1.09 64.8 -1.10 -1.40 1.12 66.1 -1.10 -1.40 1.14 67.3 -1.10 -1.40 1.17 69.6 -0.90 -1.80 1.21 71.5 -0.90 -1.80 1.24 73.3 -0.90 -1.80 1.27 75.0 -0.90 -1.80 1.29 76.5 -0.90-1.80 1.32 77.9 -0.90 -1.80 1.34 79.2 -0.90 -1.80 1.36 80.5 -0.90 -1.80 1.38 81.7 -0.90 -1.80 1.42 84.4 -0.90 -1.80 1.46 86.8 -0.90 -1.80 1.53 90.9 -0.90 -1.80 Page 2 CALCULATIONS It WALL -MOUNTED SIGNS Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: Sign type: Sign size: Wall material: Anchor type/size: P = 48.9 psf Cabinet A = 30.0 sqft (entire cabinet) Wood CDX or equiv, thickness to match Min Embed 3/8" Bolt+Nut Ref: AAMATIR-A9-1991 Min Embedment: Full Min edge dist: 1.5" Min Spacing: 1.5" Anchor tensile capacity: Tcap = 312.5 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 1466 lb ... = P"A (entire cabinet) No. of anchors req'd: n = 4.7 total anchors ...= Rt/Tcap Total anchors required: 5 total anchors balanced over cabinet OK, use min (3) attachments at top & bottom = (6) total. Page 3