HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE15--1�3
L "- _ J"�I='� — Planning & Development Services Department
o Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Lakewood Park United Methodist Church, Bell Tower
ProjectA Tess: 5405 Tumpike Feeder Rd, Ft. Pierce FI 34951
Permit#: SO6 O/Y Occupancy Type: Construction Type: CMU
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition (COPY
o Any accessory structure requiring a building permit FILEE
Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 11jL1nzCode 2010 Edition with 20 /Z- Supplements using ASCE 7-10
y Enclosed _Open _Partials 2. Structure Designed as (check one): dr_yEnclosed
3. Risk Category: _I X—II _III _IV Exposure Category: _B lX C _D
4. Design Wind Velocity Afl) mph 4ASD _LRFD End Zone Width:
S. Mean Roof Height ft Roof Pitch: :12 Parapet: it
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, dear label on all plan openings):
Zone 1: Zone ��2: Zone 3: Zone 4: Zone S•Garage:
7. DesignLoads: Floor: PSF Roof/Dead: /v'4 PSF Roof/Live--WA Balcony: X�
Dock: /ylE1 PSF Deck:'f% 11 PSF Stairs: 14V PSF Fence: PSF Railings:_,V
8. Were Shear Walls Considered For Structure? _Yes 4Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided7X—Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: W 4 PSF Soil Test Reports Submitted? Yes
4rtAft bee4f 6f my knowledge and belief, the attached plans & specifications have been designed to
t . e appl _ bje sttfyctural portions of the building codes currently adopted and enforced by St. Lucie
LI
CC3t is i
also certl�Qrucfural elements depicted on these plans provide adequate resistance to the design
�� �
r�
\1�
7rrrllllltit\\
C7
-�
Rev sed 07/25/2014
�.
t-
:i
T ,
I•
Randy Mosby
Print Name
CA# 30479
Cert # & Co. Cert Auth.
),f ' Randy L Mosby PE LLC
1575 Indian River Blvd, C210, Vero Beach, FL 32962
Company Name & Address