HomeMy WebLinkAboutPLANSdENERAL NOTES
(1) Fabric shall be flame resistant in accordance with NFPA 701 Frame Attachment detail
(2) Fabric shall be quick removable when winds forecasts exceed 75 mph
(3) Design of the structural fi-arning members based on
(a) Wind Speed based on 3 scrond gust at 162 mph
(b) Risk Category II
(c) Exposure Category B
(4) The fabric portions of awnings fabric covered firannes shall be securely laced to the firame
(5) A visible instruction to the owner to remove the fabric cover during hurricane warnings issued ExistingCBS
Wall
by the U.S. Weather Bureau shall be sewn or painted in a conspicuous area of the awning
(6) All frame material I" or 3/4" 6063 SCh 40 aluminum pipe unless stated otherwise on detail
(7) All Frame trussing to be 3/8 alluminum rod, bent and welded into place
(8) All frame members connected with 1/4 fillet weld around all interfacing edges. All weld
use the gas metal arc welding process that conform to the American Welding Society's S ctura
Welding Code -Aluminum (DI.2). Weld wire should be alloy 4043, 5183, or 5356
(9) Plans to meet current code 2014 Florida Building Code
.7
WOM
--Column Connection Detail '
(2) 1/4" x 2" x 3" 6061 AL
Angle (each side) welded to truss
and set thru 2" sch. 40 round post
w/ (2) 4" x 3/8" Stainless Bolts
L. Tja&wfmvcrs, PE
te of FL Reg No. 49399
2612 Quail Trail
Titusville, FL 32780
3212640646
July 1, 2015
Leg Mounts
(4) 4 x 3/8" SS Sleave Anchors
set thru 6" x 6" x 1/4"
6061 AL Plate and into
4" reinforced concrete existing slab
I
-
L.11A
.1cr
GESS
Clear Silicon
3 1/4" x 1/4" Tapcons set thru
Pipe and into Concrete
structure on 40" renters
or less
b..-
3 if
411
_j
[Ul
ST,XUCIECOUNTY
131.11LDING DIVISION
REVIEWED
FOR COMPU
REVIEWED BY
DATE 06-G&--_2C_Y_,r
PLANS AND P5RMIT
MUST BE KEPT ON JOB OR
3181 SE Slater
Stuart, FL 34997
772 221-8847
Century Professional Plaza
10 US Hwy. I
Desigum
Mike Peterson
Page:
Not To Scale 1 1/1
I I . I
;4
GooSle earth'
2 G
P
Certificate Of Flame Resistance
REGISTERED ISSUED BY
APPLICATION
CONCERN No. Herculite Products, Inc.
P.O. Box 435
401a Emigsville, PA. 17318
This is to certify that the materials described at the bottom hereof have been
flame-retardant treated (or are inherently nonflornable).
FOR TRIVANTAGEO,LLC AT 2937 WEST 25th STREET
CITY CLEVELAND STATE OHIO 44113
certification is hereby made that: (check "a" or "b'9
(a) The articles described at the bottom of this Certificate have been treated with a
flame-retardant chemical approved and registered by the state Fire marshal and that
the application of said chemical was done in conformance with the laws of the state of
Florida and the Rules and Regulations of the State Fire Marshal.
Name of chemical used Chem. Reg. No.
Method of application
Fx] (b) The articles described atthe bottom hereof are made from a flame -resistant
fabric or material registered and approved byTitle 19,NFPA 701 TM 2, MVSS 302
Trade name of flame -resistant fabric or material used Weblon Reg. No. F-8257247
The Flame Retardant Process Used Will Not- Be Removed By Washing
(will or will not)
Donald E. Kauffmann By Stephanie Mum ert, Q.C. Manager
Name of Production Superintendent !�Tltle
Date Work Performed
6/21/2015
we hereby certify this to be a true copy of the original "CERTIFICATE OF FLAME RESISTANCE"
issued to us, "original copy" of which has been meet Title 19, NFPA 701 TM2, MVSS302
TRI VANTAGE, LLC
Control/lot #
customer order # Mike
Tri Vantage, LLC Invoice # 40409636
C & C Canvas & Awning Co-
3181 S.E. Slater Street
Stuart, FL. 34997-5713
.f:g3�
BY CAAz6.4
Quantity 50 yards
Description Weblon Burgandy CP2715
Product Code 857247
VA
_G 0- 0 t e '"e"a"r Mm
��2015G(LO
�gle,
C2015Goo5le,