HomeMy WebLinkAboutPLAN REVIEW FORMSAINT LUCIE COUNTY FIRE DISTRICT PLAN REVIEW FORM 5160 N.W. Milner Drive SCANNEL) Port Saint Lucie, FL 34983 BY Telephone: 772-621-3322 St Lucie county Fax: 772-621-3604 Web Address: www.slcfd.com Building Dept. ISLC FMO Permit # FBI 5 219 Project Name lGrancipa's Diner BLDG Permit# F1506 0046 Address 17586-7588 South Us Hwy I city IPS L Contractor Address 154 NE Jettie Torrace city I PSL State FL Zip 1 34983 Telephone (772)361-3652 Architect/Engineer Telephone (772) 785-9888 Paul Welch OccupancyType JAssembly Construction Type Occupant Load 79 Per plans Number of Stories Access Box F I AFS Permit I FA Permit General Notes Square Feet 72014- F- Access Key Switch FFP Permit I . An electronic copy of the construction documents submitted on a CD Is required. The file format shall be.pdf only. 2. All revisions, Including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 5. Failed Inspections require payment of fee prior to rescheduling of further Inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located incloors within air conditioned space. 8. Plans and construction are subject to corrections In the field to maintain code compliance. 9. Automatic fan shutdown Is required for HVAC system/s that exceed 2,000 cfm design capacity. 10, The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2010 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. See General Notes Above and Required Revisions Below Nutomatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. Provide a remote test and spect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector. HVAC duct smoke detectorshall ? tied into the fire alarm. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and Page F1 of F Reviewed by iTony Jerger Date 1 07/22/2015