Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGaugeFlaCom vl.22 FORM 40OB-2001 Component Performance Method for Commercial Buildings Jurisdiction: DADE COUNTY, DADE co=y, FL (23i000) Short Dese: UDS007681 Owner: MOD SPACE Address: UNKNOWN UNKNOWN City. UNKNOWN State: FLORIDA zip. 0 1)7pe: Office (Business) Class: New Finished building Project- MOD SPACE PerinitNo: 0— Storeys: I GrossAxea: 440 Net Area: 440 SCANIVSD St. t 13V (1016 Colin, 1, Max Tonnage: 4 (if different, write in) CompHance Summary Component Design Criteria Result ENVELOPE 20.29 48.91 PASSES Other Envelope Requirements - B LIGHTING POWER LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES - - 700.00 836.00 PASSES PASSES PASSES PASSES PASSES PASSES PASSES Ye--/No/NA IMPORTANTNOTE An input report Print -Out from EnergyGauge FZtzCom of this design building must be submitted along u*h this ConWfiance Report. 5/4/2015 EnergyGnuge FluCoin FLCCSB v1.22 COMPLIANCE CERTIFICAXION: I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are in calculation indicates compliance with the Florida Energy Code. compliance with the Florida Energy Efficiency Before construction is completed, this building will be inspected Code, for compliance in accordance with Section 553.908, F.S. PREPARED BY: BUILDING OFFICIAL: DATK-. 6—/-4/ DATE: I hereb 'P ir t at this building is in'com I' c (��t is u n 3ye n rgy fi cy with the V, orida E�rgy Ef iciancy Clso�e.' DATE: I if required by Florida law, I hereby certify (*) that the system design is in compliance I with the Florida Energy Code. REGISTRATION No. ARCHITECT: htwoo�io6Z5 ELECTRICAL SYSTEM DESIGNER: LIGHTING SYSTEM DESIGNER: MECILANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. Project: MDS007681 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (231000) (%VEA File: Miami.tray) Envelope Compliance Design Load Criteria Zone Heating Cooling Heating Cooling OFFICE AREAS (CONDITIONED) -1.63 18.66 -8.87 40.05 Total Loads: Desim =20.29 Ciriterla =48.912 1 PASSES � I 5/4/2015 EnergyGauge FloCom FLCCSB v1.22 2 Project: MDS007681 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (2310oo) (WEA File: Dfflami.tmy) Other Envelope Requirements Item Zone Description Design Limit Meet Req. OFFICE AREA % Skylight - Max % Limit 0.00 6.70 Yes OFFICE AREA OFFICE AREA Exterior Roof - Max Uo Limit 0.05 0.08 Yes Meets Other Envelope Requirements Project* MDS007681 Tiffe: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL p31000) (WEA File: Nflami.tmy) External Lighting Compliance Description Category Allowance Area or Length RLPA , ='P (W/Unit) orNo.ofUnits (W) (W) (Sqft or ft) Ryt Tight 1 Ext Light 2 Rxit (with nr vAtbmit (Anopy) Exit (with or without Canopy) )Son 25.00 10 75 ISO 3.0 75 60 Ext Light 3 Exit (with or without Canopy) 25.00 3.0 75 60 Design: 180 (W) PASSE� 1AHowance: 225 (W) Project: MDS007681 Title: MOD SPACE Type: Office (Business) Locationi DADE COUNTY, DADE COUNTY, FL (231000) (WEA File: Aliami.tmy) Lighting Power Compliance Space Ashme Description Area Height No.of AF Design Effective All owance ED (sq.ft) (11) Spaces (W) (W) (W) OFFICE 29 Offic� (Pardtiom 3.5-4.5 ft 440 8.0 1 1.00 1000 700 836 below ceiling) Open plan offices 900 ft or larger with partitions 3. Design 1000 (W) PASSES Effective; 700 (W) Allowance: 836 (W) 51,112015 EnergyGaugeFlaCom FLCCSIB v1.22 I MOD SPACE Office (Business) Ion: DADE COUNTY, DADE COUNTY, F I Other Required Compliance Category Section Requirement (write N/A in box if not applipble) Check Infiltratron 406.1 Infiltmtion r�teria have. been ntet System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation critena have been met V ADS 410.1 Duct sizing and Design have been performed T&B 410.1 Testing and Balancing will be performed Electrical 413.1 Metenng,criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting enteria have been met O&M 102.1 Operation/marnterrance manual will be provided to owner Roof/Ceil 404.1 R-1 9 for Roof Deck with supply plenums beneath it Report 101 Input Report Prmt-Out from EnergyGauge FlaCom. attached9 5/412015 EnergyGaugeFluCom FLCCSB v1.22 6