EnergyGauge Summ tT-F . 1,a,,/C . orn�2 . 0 41' . 0, Effktive Date: March 1 -1 . 5, 2012 — Form 506-2010
Tbtal.B.� -M 6 thod for Commercial Buildings
SCANNED
BY
S cie Count,
t. Lu
PROJECT SUMMARY
Short Desc:
MS2000476
Description:
MS200476
Owner:
MOD SPACE INC
Addressl:
Enter Address here
City:
Address2:
Enter Address here
State:
FL
Zip:
0
Type:
Office
Class:
New Special class building
Jurisdiction:
ORLANDO, ORANGE COUNTY� FL (582100)
Conditioned Area:
1486 SF
Conditioned & UnConditioned Area:
1486 SF
No of Stories:
I
Area entered from Plans
1493 SF
Permit No:
0
Max Tonnage
3.4
If different, write in:
I 1 2 Xi%. �' I
L
- LIN.
EnergyGaugeSum ml Fla/Com-2010. Sedon 506.4 Compliant Software. Effective Date: March 15, 2012
Page I of 7
4/27/2015
nee
Component
Design
Criteria
Result
Gross Energy Cost (in
f,121.0
1,252.0
PASSED
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
No Entry
PASSES
No Entry
PASSES
No Entry
Yes/No/NA
IMPORTANT MESSAGE
Info 5009 -- -- — An input report of this design building must be submitted along with this
EnergyGauge Summit@ Fla/Com-2010. Secfi�n 506.4 Compliant Software. Effective Date: March 15,2012
Page 2 of 7
4/27/2015
CERTIFICATIONS
I hereby certify that the plans and specifications c by-'-(H1i*ce7deV are in compliance with the
Florida Energy Code p,. BC),b
Prepared J A.B H '. 1. Bit ding Official:
0 /27 2��js ROO Date:
I certify that this building is in compliance with rida Energy Effid" ode
Owner Agent: Date:
OF FL
If Required by Florida law, I ereby certify (*) that t d6�igirwf- - Hance with the Florida Energy
Efficiency Code 130 7
i t: OHNA.BO V. Reg No: AR0005065
Electrical D� 6 Reg No:
04/27/2015
Lighting Designer: Reg No:
..........
Mechanical Designer: A Reg No:
Plumbing Designer: Reg No:
Signature is required where Florida Law requires design to be performed by registered design
professionals.
EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15,2012
Page 3 of 7
4/27/2015
Project: MS2000476
Title: MS200476
Type: Office
I Total
ELEGTR1ClTY(MBtu1kWh1$)
AREA LIGHTS
MISC EQUIPIVIT
PUMPS & MISC
SPACE COOL
SPACE HEAT
VENTFANS
Building End Uses
1) Proposed 2) Baseline
71.70 99.90
$1,121 $1,565
71.70
99.90
21034
29300
$1,121
$1,565
13.30
17.40
3896
5110
$208
$273
21.20
21.20
6204
6204
$331
$331
Applied: None
Criteria = 1252
(including any credits) = 1121
� requires Proposed Building cost to be at most 80% of
e cost This Proposed Building is at 71.7%
0.00
13
$1
20.70
6077
$324
0.70
210
15.80
4634
$247
0.00
10
$1
27.00
7924
$423
0.50
161
$9
33.80
9891
$528
SSES
4/27/2015 ' EnergyGauge Summit@ FialCom-2010. Section 506A Compliant SoftWare. Effective Date: March 15, 2012 Page 4 of 7
External Lighting Compliance
Description
Category Tradable?
Allowance AreaorLength ELPA
CLP
(W/Unit) or No. of Units (W)
(W)
(Sqft or ft)
None
Project: MS2000476
Title: MS200476
Type: Office
(WEA File: Fl, ORLANDO INTL ARPT.tm3)
Lighting Controls Compliance
Acronym
Ashrae Description
Area Design Min
Compli-
11)
(sq.ft) CP CP
once
PR OFF 1
17 Office - Enclosed
158 4 2
PASSES
PR OFF 2
17 Off -ice - Enclosed
146 4 2
PASSES
OPEN OFF N
16 Office - Open Plan
134 2 1
PASSES
OPEN OFF S
16 Office - Open Plan
659 2 1
PASSES
BATHROOM
I Electrical Mechanical Equipment
86 1 1
PASSES
Room - General
PASSES
Project: MS2000476
Title: MS200476
Type: Office
(WEA File: Fl, ORLANDO INTL,ARPT.tm3)
System Report Compliance
PrOSyl System 1
Constant Volume Packaged
No. of Units
System
2
Component
Category Capacity
Design Eff Design
IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System
Air Conditioners Air Cooled 40500
13.00 12.23 8.00
PASSES
< 65000 Bru/h Cooling
Capacity
Heating System
Heat Pumps Air Cooled 34000
3.00 2.25
PASSES
(Heating Mode) < 65000
Btu/h Cooling Capacity
Air Handling
Air Handler (Supply) - 1500
0.80 0.82
PASSES
System -Supply
Constant Volume
PASSE=:]
4/27/2015 EnergyGauge Summit@ FialCom-201 0. Section 506.4 Compliant Software. Effective Date: March 15, 2012 Page 5 of 7
Plant Compliance
Description Installed Size Design Min Design Min Categ Comp
.ory
No Eff Eff IPLV IPLV liance
Project: MS2000476
Title: MS200476
Type: Office
(WEA File; FL ORLANDO INTL ARPT.tm3)
Water Heater Compliance
Description
Design Min
Type Category Eff Eff
Design
Loss
Max Comp
Loss liance
Water Heater 2
Electric water heater <= 12 [kW] 2.00 0.89
PASSES
PASSES
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond
Iinchesj Runout? Temp [Btu-inthr
IF] SF.FI
Ins
Thick linj
Req Ins Compliance
Thick Iinj
NoneT77:]
4/27/2015 EnergyGauge Summi@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15,2012 Page 6 of 7
-t: MS2000476
MS200476
Office
,File: FL—ORLANDO_INTL—ARPT.tm3)
Other Required Compliance
Category
Section
Requirement (write N/A in box if not applicable)
Check
506.4.2
Input Report Print -Out from EnergyGauge FlaCom attached
Report
to owner
Operations Manual
303.3.1,
Operations manual provided
503.2.9.3,
505.7.4.2
502.3.2
Glazed swinging entrance & revolving doors: max. 1.0 cl"im/fe; all
Windows & Doors
other products: 0.3 cim/fe
Joints/Cracks
502.3.3
To be caulked, gasketed, we ather-stripped or otherwise sealed
Dropped Ceiling Cavity
502.3
Vented: seal & insulated ceiling. Unvented seal & insulate roof &
side walls
HVAC Efficiency
503.2.3
Minimum efficiencies: Tables 503.2.3(1 �(8)
HVAC Controls
503.2.4
Zone controls prevent reheat (exceptions); separate thenrostatic
503.2.5
control per zone; t ducts shall have dampers that
Outdoor air supply & exhaus
El
ventilation
automatically shut when systems or spaces served are not in use.
Exhaust air energy recovery required for cooling systems
(Exceptions).
'ADS
503.2.7.5
Duct sizing and Design have been performed
503.2.7
Air ducts, linings, mechanical equipment & plenum chambers shall
El
HVAC Ducts
be mechanically attached, sealed, insulated & installed per Table
503.2.7.2. Fan power limitations.
Balancing
503.2.9.1
HVAC distribution systern(s) tested & balanced. Report in
El
construction documents.
Piping Insulation
503.2.9
HAC and service hot water. In accordance with Table 503.2.8-
El
504
Performance requirements in accordance with Table 504.2. Beat
El
Water Heaters
Swimming Pools
504.7
trap required.
Vapor -retardant or liquid cover or other means proven to reduce
heat loss on heated pools; Time switch (exceptions); readily
accessible ontoff switch.
have been met
El
Motors
505.7.5
Motor efficiency criteria
Lighting Controls
505.2, 502.3
Automatic control required for interior lighting in buildings >5,000
El
s.f.; Space control; Exterior photo sensor; Tandorn wiring with I or
3 linear fluorescent lamps>30W
EnergyGauge Surmnit@ Aa/Com-201 0. Section 506.4 Compliant Software. Effective Date: March 15,2012 Page 7 of 7
4/27/2015