HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEI
Planning & Development Services Department
Building & Codo 11@gulaflons Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1550CANNV-
RECEI . L; ;J;, 2 9'2015 Certification for Design Load Compliance St. LUcn, �uunty
Project Name: Canopy Addition Pursuit Boats
Project Address: 3901 St. Lucie Blvd. Fort Pierce, FL 34946
Permit#: 1506-0482
Occupancy Type: F-1 Construction Type- 111-B
INSTRUCTIONS FOR USE:
a This certification must be completed, signed, and sealed by the design professional of record.
a Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following;
• New Residences (single or multi -family) Aaitk
• Residential Addition Is 2
• Any accessory structure requiring a building permit WPY
• Any non-residential structure. FILE %,A "'
Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1.
DESIGN CODE: Florida Building
Code 2010 Edition with 20 10 Supplements using ASCE 7-10
2.
Structure Designed as (check one):
Enclosed X Partially Enclosed
Open
3.
Risk Category: —1 X 11
111 — IV Exposure Category: B X C
D
4.
Design Wind Velocity _160_mph
_ASD X URFD End Zone Width: 6
ft
5.
Mean Roof Height 25
Roof Pitch: 1/2 :12 Parapet: N/A
ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sqft @ 15'MRH, clearly label on all plan openings):
Zone 1: +20/-36 Zone 2: +201-55 Zone 3: +20/-78 Zone 4: +361-39 Zone 5: +361-46 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? — Yes x Not Applicable Explain Why Not:
PRE-ENGINEERED METAL BLDG WITH VERTICAL WALL BRACING AND PORTAL FRAMES
9. IsA Continuous Load Path Provided? X Yes _NotApplicabie ExplainWhyNot:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? No Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified: , I
Michael A. Lue, P.E. FL 47520
f f Print Name Cert # & Co. Cert Auth.
M L Engineering, Inc.
n
2030 37th Ave, Vero Beach, F1 32960
ignature, �Dafe,r:;nd Seal
Company Name &Address
Revised 07/25/2014