HomeMy WebLinkAboutPROJECT INFORMATION 3Right -Suite@ Universal 2015 Short Form Job:
wrightsoft Date:
Entire Bldg. 13y; SCANNED
QUICK CALCS, INC. BY
St. Lucie County
317 ST LUCIE LN., FT PIERCE, FL 34946 Phwe: 772466-6799 Fax 772-466-6796 Emil: QUICKCALCS@AOLCOM
Project Information
For. BLUE COLLAR DOG TRAINER
3988 KINGS HIGHWAY, Fr. PIERCE, FL
Htg Cig
Htg Clg
Outside db
CF)
42 90
Inside db
(OF)
70 75
Outside RH
(0/0)
- 59
Inside RH
M
- 50
Outside wb
(OF)
- 78
Inside wb
(OF)
- 63
Daily range
(OF)
- 15
Design TD
CF)
28 15
Moisture diff.
(gr/lb)
- 61
Heating Equipment Cooling Equipment
Make
Model
Type
Efficiency
Heating Input
Heating Output
Humidifier
LewAng Air Temp
Actual Heating Fan
Else strip
100 EFF
6.1
kW
20.9
MBtuh
6.7
gpd
80.9
OF
1750
cfrn
Equipment Location
System Type
Fan Motor Heat Type
Fan & Motor Combined Efficiency
Static Pressure Across Fan
Make
CarTier
Model CA16NA060-0-A1FX4DN(B,F)061
Type
SplitAC
COP/EER/SEER
16.0
Sensible Cooling
36.8
MBtuh
Latent Cooling
15.8
MBtuh
Total Cooling
52.5
MBtuh
Lea,AngAirTemp
55.0
OF
Actual Cooling Fan
1750
cfm
Entire Bldg.
PEAKCV
PACKAGE
0 %
0 in H20
NAME
Area
ftZ
Heat
Loss
Sensible
Gain
Latent
Gain
Htg
Cfm
Cig
Cfm
Time
ROOM 3
196
1213
2912
1957
153
181
Jul 1600 LDT
ROOM 4
154
953
2483
1847
120
150
Jul 1600 LDT
ROOM 6
275
2843
3983
2582
353
259
Jul 1600 LDT
ROOM 1
286
1645
8480
13977
203
585
Jul 1600 LDT
ROOM 2
234
1637
3049
1857
211
191
Jul 1600 LDT
ROOM 5
440
5591
5681
3232
710
382
Jul 1600 LDT
I Entire Bldg.
1 1585
1 13882
1 26587
1 25452
1 1750
1 1750
1 Jul 1600 LDT
2015Zep-22 13:42:51
wrlghtSoft� R'Ight.SulteOLInN�a[201515.0.19RSL]38101 Page 1
... ck CaIWD=u=ntsNI3LUE COLLAR DOG TRAINING.mp Calc=CLM FmtDwrbces: N
Right -Suite@ Universal 2015 Load Summary Job:
wrightsofr Date:
Entire Bldg. Ely:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phwe: 772466-6799 Fax 772466-6796 Errdl: OUICKCALCS@AOLCOM
For. BLUE COLLAR DOG TRAINER
3988 KINGS HIGHWAY, FT PIERCE, FL I;Nw
Ci� Opy
tire: - g. C00LINGL0AD--"--'
1.
DESIGN CONDITIONS at Jul 1600 LDT
Peak load at Jul 1600 LDT
Inside: 75 OF Outside: 90 OF
TD:
15 OF
RH: 59 % Moist[Diff: 61.5 gr/lb
Mult:
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
0
3.
TRANSNUSSION GAINS Sensible
4554
Walls: 0
-
-
Glass: 0
-
-
Doors: 302
-
-
Partitions: 0
-
-
Floors: 0
-
-
Ceilings., 4253
-
-
4.
INTERNAL HEAT GAIN Sensible
Latent
12778
2000
Occupants: 2500
2000
-
-
Lights: 10278
-
Motors: 0
-
Appliances: 0
0
-
-
5.
INFUTRATION: Outside air cfm:
411
6782
17186
6.
SUBTOTAL: Spaceload Sensible
Latent
24115
19186
Envelope 24115
19186
-
-
Less e)demal 0
-
Redistribution 0
0
-
7.
SUPPLY]DUCT
0
8.
SUBTOTAL: Space load + supply duct
24115
Actual cfm: 1750 at sup?ly TD:
20
-
-
9.
VENTILATION: Make-up air c m:
150
2473
6266
10.
RETURNAIRLOAD: Lighting + plenum (net)
0
-
11.
RETURINDUCT
0
-
12.
TOTAL LOADS ON EQUIPMENT
26587
25452
HEATING LOAD---'..--'-
13.
DESIGN CONDITIONS
Mult:
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF
14.
TRANSMISSION LOSSES
4922
Walls: 0
-
Glass: 0
-
Doors: 583
-
Partitions: 0
-
Floors: 2822
-
Ceilings: 1517
-
15.
INFULTRATION: Outside air cfm:
209
6431
16.
SUBTOTAL: Spaceload
11353
Envelope 11353
-
Less external 0
-
Less transfer 0
-
Redistribution 0
-
17.
SUPPLYDUCT-
0
18.
VENTELATION: Make-up air cfm:
0
0
19.
HUNUDETICATION
2529
Piping
0
20.
RETURN DUCT
0
21.
TOTAL HEATING LOAD ON EQUIPMENT
13882
wrightsoft, 2015-Sep-22 13:42:51
Right-SulteQ Univemal 201515.0.19 RSLM101 Page I
... ck CaIcsXDmuwntMB1-UE COLLAR DOG TRAINING.mp Calc=CLM ftntDODrfaces: N
PROJECT SUMMARY
Short Desc: BLUE COLLAR
Owner:
Addressl: 3988YJNGSHOGHWAY
Address2:
Description: BLUE COLLAR DOG
City: FT. PIERCE
State: FL
Zip: 0
1�pe:
Office
Class:
Renovation to existing
Jurisdiction:
FORT PIERCE, ST LUCIE COUNTY, FL (661100)
Conditioned Area:
1585 SF
Conditioned & UnConditioned Area:
1585 SF
No of Stories:
I
Area entered from Plans
0 SF
Permit No:
0
Max Tonnage
4.4
If different, write in:
EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012
8/24/2015 Page I of 7
Component
Energy Cost
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
Design Criteria Result
832.0 1,130.0 PASSED
PASSES
No Entry
PASSES
No Entry
No Entry
No Entry
Yes/No/NA
IMPORTANT MESSAGE
Info 5009 -- -- -- An input report of this design building must be submitted along with this
W I
1MVIS it -
VQ -- ME"
4"'1:11 1 r ue)" a-1. I -A"
- I N, � M RlfffARF I
EnergyGauge Summit@ FlatCom-201 0. Section 506.4 Compliant Software. Effective Date: March 15, 2012
8/24/2015 1 Page 2 of 7
CERTTICATIONS
I hereby certify that the plans and specification covered by this calculation are in compliance with the
Florida Energy Code ;�<' I
Prepared By. 41itgg Official:
Date: Date:
I certify that this building is in compliance with the FLorida Energy Efficiency Code
Owner Agent: Date:
If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida
Energy Efficiency Code
Architect: Reg No:
Electrical Designer: Reg No:
Lighting Designer: K- &QC4W42 I / Reg No:
Mechanical Designer:, CCKAXOLttSWS�7k�-RegNo: /9/65i'q/
Plumbing Designer: Reg No:
Signature is required where Florida Law requires design to be performed by registered design
professionals.
U, k
EnergyGauge Summit@ Fla/Com-201 0. Section 506.4 Compliant Software. Effective Date: March 15, 2012
8/24/2015 Page 3 of 7
Project: BLUE COLIAR
Tifle: BLUE COLIAR DOG TIRAINING
'4pe: Office F LE COPY
—(WEA File: FL ST LUCEE CO ETM.tm3)
Building End Uses
1) Proposed 2) Baseline
Total 53.60 90.30
$832 $1,413
ELECTRICITY(MBtu/kWh 53.60 90.30
15701 26456
S832 S1,413
AREA LIGHTS 3.90 18.20
1148 5340
$61 $285
MISC EQUIPMT 23.80 23.80
6967 6967
$369 $372
PUMPS & MISC 0.10 0.10
22 19
$1 $1
SPACE COOL 12.40 24.00
3631 7018
$192 $375
SPACE HEAT 0.80 1.40
238 419
$13 $22
VENT FANS 12.60 22.80
3695 6693
$196 $357
Credits Applied: None PASSES
Passing Criteria = 1130
Design (including any credits) = 832
,Passing requires Proposed Building cost to be at most 80% of
Baseline cost. This Proposed Building is at 58.9%
EnergyGauge Summit@ Fla/Com-201 0. Section 506.4 Compliant Software. Effective Date: March 15, 2012
8/24/2015 Page 4 of 7
External Lighting Compliance
Description Category Tradable? Allowance Area or Length ELPA CLP
(W[Unit) or No. of Units (W) (W)
(Sqft or ft)
None
Project: BLUE COLLAR
Title: BLUE COLLAR DOG TRAINING
Type: Office
(WEA File: Fl, ST LUCIE CO INTL.tm3)
Lighting Controls Compliance
Acronym Ashrae Descriution Area Design Min Compli-
ID (sq.ft) CP CP once
PrOZOISPI 16 Office - Open Plan 1,585 1 1 PASSES
I PASSES I
ect: BLUE COLLAR
BLUE COLLAR DOG TRAINING
Office
System Report Compliance
System 1 Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr I
Component
Category
Capacity
Design
Eff
Eff
Criteria
Design 11PLV Comp-
IPLV Criteria liance
Cooling System
Air Conditioners Air Cooled
52500
16.00
12.23
8.00 PASSES
Split System < 65000 Btu/h
Cooling Capacity
Heating System
Electric Furnace
34000
1.00
1.00
PASSES
Air Handling System Air Handler (Supply) -
1750
0.80
0.82
PASSES
-supply
Constant Volume
PASSES
EnergyGauge Summit@ Fla/Com-201 0. Section 506.4 Compliant Software. Effective Date: March 15, 2012
8/24/2015 Page 5 of 7
Plant Compliance
Description Installed Size Design Min Design
No Eff Eff IPLV
Min Category Comp
IPLV Hance
I
I NonE::::::::1j
Water Heater Compliance
Design Min
Description Type Category Eff Eff
Design Max Comp
Loss Loss Hance
I None :3
Piping System Compliance
Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance
[inches] Runout? Temp [Btu-in/hr Thicklinj Thick[inj
M SF.Fj
I
None
EnergyGauge Summit@ Fla[Com-201 0. Section 506.4 Compliant Software. Effective Date: March 15, 2012
8/24/2015 Page 6 of 7
BLUE COLLAR
BLUE COLLAR DOG TRAhqNG
Office
L File: FL_ST_LUCEE_C0_INTL.tm3)
Other Required Compliance
Category Section
Requirement (write N/A in box if not applicable)
Check
Report 506.4.2
Input Report Print -Out from EnergyGauge FlaCom attached
Q
Operations Manual 303.3.1,
Operations manual provided to owner
El
503.2.9.3,
505.7.4.2
Windows & Doors 502.3.2
Glazed swinging entrance & revolving doors: max. 1.0 cfin /ft2 ; all
other products: 0.3 cfin/ft2
Joints/Cracks 502.3.3
To be caulked, gasketed, weather-stripped or otherwise sealed
El
Dropped Ceiling Cavity 502.3
Vented: seal & insulated ceiling. Unvented seal & insulate roof &
side walls
HVAC Efficiency 503.2.3
Minimum efficiencies: Tables 503.2.3(l)-(8)
El
HVAC Controls 503.2.4
Zone controls prevent reheat (exceptions); separate thermostatic
El
control per zone;
Ventilation 503.2.5
Outdoor air supply & exhaust ducts shall have dampers that
automatically shut when systems or spaces served are not in use.
Exhaust air energy recovery required for cooling systems
(Exceptions).
ADS 503.2.7.5
Duct sizing and Design have been performed
HVAC Ducts 503.2.7
Air ducts, fittings, mechanical equipment & plenum chambers shall
be mechanically attached, sealed, insulated & installed per Table
503.2.7.2. Fan power limitations.
Balancing 503.2.9.1
HVAC distribution system(s) tested & balanced. Report in
construction documents.
Piping Insulation 503.2.8
HAC and service hot water. In accordance with Table 503.2.8.
Water Heaters 504
Performance requirements in accordance with Table 504.2. Heat
trap required.
Swimming Pools 504.7
Vapor -retardant or liquid cover or other means proven to reduce
heat loss on heated pools; Ti
ime switch (exceptions); readily
accessible on/off switch.
Motors 505.7.5
Motor efficiency criteria have been met
El
Lighting Controls 505.2, 502.3
Automatic control required for interior lighting in buildings >5,000
El
s.f; Space control; Exterior photo sensor; Tandom wiring with I or
3 linear fluorescent lamps>30W
-M3
EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012
8/24/2015 Page 7 of 7
oil
I Avnv�
num
10
EnergyGauge Summit@ v5.00
Project Information
Project Name: BLUE COLLAR
ProjectTitle: BLUE COLLAR DOG TRAINING
Address: 3988 KINGS HOGHWAY
State: FL
Zip: 0
Owner:
Orientation: North
Building Type: Office
Building Classification: Renovation to existing building
No.of Stories: I
GrossArea: 1585 SF
Zones
No Acronym Description T�pe
Area
lsfl
Multiplier
Total Area
Isq
I PrOZol Zone I CONDITIONED
1585.2
1
1585.2 El
Spaces
No Acronym Description 1�pe Depth
IN
Width Height Multi
IN [ftl plier
TotalArea
lsq
Total Volume
leg
8/24/2015
EnergyGauge Summit@ v5.00
I
M
10
mull
1 vii
09,2111
In Zone: Pr0ZoI
I Pr0ZolSD1
ZoOSpl Office - Open Plan
32.35
49.00
9.00
1
1585.2
14266.4
Lighting
No
Type Category
No. of
Watts per
Power
Control 1�pe
No.of
Luminaires
Luminaire
[W]
Ctrl pts
In Zone: PrOZo
In Space: Pr0ZoISpI
I
Compact Fluorescent General Lighting
is
25
375
Manual On/Off
I
El
Walls
No Description
Type Width H (Effec) Multi
Area DirectionConductance
Heat
Dens. R-Value
[ft]
[ft] plier
Isf]
[Btu/hr. sf. F]
Capacity
Ilb/cfl [h.sEF/Btu]
[Btu/sEFj
In Zone: PrOZol
I PrOZolWal
8"CMU/3/4"ISO 49.00
9.00 1
441.0
North
0.2642
9.696
62.72 3.8
El
BTWN24"oc/5/8
2 Pr0ZolWa2
Gyp
8"CMU/3/4"ISO 32.35
9.00 1
291.2
East
0.2642
9.696
62.72 3.8
El
BTV;N24"oc/5/8
3 Pr0ZolWa3
Gyp
8"CNW/3/4"ISO 49.00
9.00 1
441.0
South
0.2642
9.696
62.72 3.8
El
BTWN24"oc/5/8
GYP
Windows
No
Description I�Vpe Shaded
U SHGC Vis.T)ra
W
H (Effec)
Multi
Total Area
[Btu/hr sf F1
Ift]
[ft]
plier
Isf]
In Zone:
In Wall:
9/2412015
EnergyGauge Summit@ v5.00
Doors
No Description 1),pe
Shaded? Width H (Effec) Multi
Area
Cond. Dens. Heat Cap.
R-Value
Ift] 11t]
plier
[sp
[Btu/hr. sf. F] [lb/cfl [Btu/sE 19
[h.sf.F/Btu]
In Zone: PrOZol
In Wall: EAST
I Pr0ZolWa2Drl Solid core flush
No
3.00 6.80
1
20.4
0.3504 0.00
0.00
2.85
F-1
(2.25)
In Wall: SOUTH
I PrOZolWa3Drl Solid core flush
No
3.00 6.80
2
20.4
0.3504 0.00
0.00
2.85
0
(2.25)
Roofs
No Description Type
Width
H(Effec) Multi
Area
Tilt
Cond. Heat Cap
Dens.
R-Value
IN
[ft] plier
lsfl
[deg]
[Btu/hr. SE F] [Btulsf.19
Rb/cfl
[h.sf.F/Btul
In Zone: PrOZol
I PrOZolRfl Mtl Bldg Roof/R-19
49.00
32.35 1
1585.2
0.00
0.0492 1.34
9.49
20.3
El
Bart
Skylights
L
No Description Type
U SHGC Vis.Trans
W
H(Effec)Multiulier
Area
TotalArea
[Btu/hr sf F]
Ift]
Ift]
1Sq
IS11
In Zone-
E]
Floors
No Description Type
Width
H(Effec) Multi
Area
Cond. Heat Cap. Dens.
R-Value
Ift]
[ft] plier
fsfl
[Btulhr. sE Fj [Btu/sE F] Rb/cfl
[h.sf.F/Btu]
lInzone: Prozol
8/24/2015 EnergyGauge Summit@ v5.00
NC, W�bi
AME
MA
NMI
I ProZoIFII I ft. soil, concrete
floor, carpet and
rubber pad
49.00 32.35 1 1585.2 0.2681 34.00 113.33 3.73
Systems
PrOSyl System I
Constant Volume Air Cooled Split No. Of Units I
System < 65000 Btu/hr
Component Category
Capacity Efficiency IPLv
I Cooling System
2 Heating System
3 Air Handling System -Supply
52500.00 16.00 8.00
34000.00 1.00
1750.00 0,80
EJ
IJ
Plant
Equipment Category
size Inst.No Eff. IPLv
Water Heaters
W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss
Ext-Lighting
Description Category No. of Wafts per Area/Len/No. of units Control I�pe Wattage
Luminaires Luminaire [sVfttNol [W]
El
8/24/2015
EnergyGauge Summit@ v5.00
1 t�nmwo--,
7171 t
24
Piping
Operating Insulation Nomonal pipe Insulation Is Runout?
No Type Temperature Conductivity Diameter Thickness
[F] Btu-in/h.sEF] [in] [in]
II -�-;Ljli
Fenestration Used
Name Glass Type No. of Glass SHGC VLT
Conductance
Panes [Btu/h.sEF] El
Materials Used
Only R-Value RValue Thickness
Conductivity
Density
SpecificHeat
Mat No
Acronym
Description
Used lb.sEF/Btu]
IN
lBtu/h.ft.Fl
llb/cfl
[Btu/Ib.Fj
IS/
MatI187
(JYF OR FLAS
No 0.4533
0.0417
0.0920
Mr"=
BOARD,1/21N
178
Matl178
CARPET W/RUBBER PAD
Yes 1.2300
El
265
Mat1265
Soil, I ft
No 2.0000
1.0000
0.5000
100.00
0.2000
[1
48
Mat148
6 in. Heavyweight concrete
No 0.5000
0.5000
1.0000
140.00
0.2000
El
105
Matl105
CONC BLK HW, 81N,
No 1.1002
0.6667
O�6060
69.00
0.2000
HOLLOW
269
Mat1269
.75 " ISO BTWN24" oc
No 2.2321
0.0625
0.0280
4.19
0.3000
23
Matl23
6 in. Insulation
No 20.0000
0.5000
0.0250
5.70
0.2000
94
Mat194
BUILT-UP ROOFING, 3/8IN
No 0.3366
0.0313
0.0930
70.00
0.3500
Constructs Used
8/2412015 EnergyGauge SummitV v5.00 5
l V15K
r— IFU
im
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.Fl
fBtu/sf.Fl
Pb/cf]
jh.sf.F/BtuJ
1014
8"CNW/3/4"ISO BTWN24"oc/5/8 Gyp No
No 0.26
9.70
62.72
3.8
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
105
CONC BLK HW, 81N, HOLLOW
0.6667
0.000
2
269
.75" ISO BTWN24" oc;
0.0625
0.000
3
187
GYP OR PLAS BOARD, 1/21N
0.0417
0.000
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.Fl
[Btu/sf.Fl
[lb/cf]
[h.sEF/Btul
1056
Mtl Bldg Roof/R-19 Batt
No
No 0.05
1.34
9.49
20.3
E3
Layer
Material
Material
Thickness
Framing
No.
IN
Factor
1
94
BUILT-UP ROOFING, 3/8IN
0.0313
0.000
2
23
6 in. Insulation
0.5000
0.000
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sEF]
[Btu/sf.Fl
Ilb/cfl
[h.sEF/Btuj
1057
1 ft. soil, concrete floor, carpet and rubber pad No
No 0.27
34.00
113.33
3.7
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
265
Soil, I ft
1.0000
0.000
2
48
6 in. Heavyweight concrete
0.5000
0.000
E]
3
178
CARPET W/RUBBER PAD
0.000
El
8/24/2015
EnergyGange Summit@ v5.00
No Name Simple Massless Conductance Heat Capacity Density RValue
Construct Construct [Btu/h.sf.Fj [Btu/sEF] [lb/cfl [h.sEF/Btuj
1058 Solid core flush (2.25) No Yes 0.35 2.9
Layer Material Material Thickness Framing
No. Ift] Factor
1 279 Solid core flush (2.25") 0.000 El
8/24/2015 EnergyGauge Summit@ v5.00 7