Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATIO Address: 8420 S U S 1 City / State I Zip: Port St Lucie, FI 34952 Parcel #: 3414-501-1903-010/8 Zoning: CG APPLICATION INFORMATION Permit Number: 1507-0077 PermitType: COMMERCIAL RENOVATION REVIEW COMMENTS scANNEU BY at. Lucie Count' I Owner(s): Lakes Plaza LIc Jurisdiction: ST LUCIE COUNTY Lot#: P3-5 Block: 3 Stories: Automatic Sprinkler System? No CONTRACTOR INFORMATION Contractor Name: Lloyd M Constant Fax Number: Business Name: Andros Roofing & Construction LIc Email: Androsconstruction@Gmail. Business Addr: 2706 Atlantic Ave Com City / State / Zip: Fort Pierce, FI 34947 REVIEWS AND COMMENTS ReviewType Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Audrey Humphrey 71612015 7/6/2015 Comment: NEEDS A SUB AGREEMENT FOR ELECTRICAL. 7/6/2015 Comment: NEEDS ASUB AGREEMENT FOR PLUMBING. 716/2015 Comment: NEEDS A SUB SUMMARY. 7/6/2015 Comment: NEEDS (2) ELECTRONIC VERSIONS OF PLANS (CID) 71612015 Comment: NEEDS (3) SETS OF PLANS WITH THE 5TH ADDITION 2014 BUILDING CODES. 7114/2015 Comment: MECHANICAL SUB AGRBE—MENT. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 71612015 71612015 71612015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 812412015 8124/2015 8/24/2015 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Kevin Singley 8119/2015 8/19/2015 Comment: ASSEMBLY AREAS, BREAK ROOM AMD RESTROOMS NEED TO COMPLY EWITH THE MINIMUM VENTILATION RATES SET FOURTH BY 2014 FBCM, TABLE 403.3 8/1912015 Comment: AHU#3 AND CU#3 ARE SHOWN ON PANEL SCHEDULES A, B, AND C / PLEASE MAKE CORRECTIONS 8/19/2015 Comment: AHU AND CU #2 ARE NOT SHOWN ON PANEL SCHEDULES 1. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS U 8/19/2015 Comment: INCLUDE CONDITIONED AIR REQUIRED FOR THE MECHANICAL ROOMS ON T& B PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 811912015 8/19/2015 Comment: PLEASE REFER TO THE CORRECT CODE (2014)PLUMBING CODE 8/19/2015 Comment: THE PLANS YOU SUBMITTED ARE NOT SIGNED AND SEALED DOCUMENTS PLEASE RESUBMIT SIGN AND SEALED PLANS 3 SETS PLANS EXAMINER REVIEW INCOMPLETE Joe Ciclo 811912015 Comment: DESIGN PROFESSIONAL TO INCLUDE A CODE REFERENCE BOX ON PLANS AS TO CODES DESIGNED TO THIS FACILITY WILL BE UNDER THE 2014 FLORIDA BUILDING CODE 5TH EDITION LIBRARY ] INCLUDE 8/19/2015 BUILDING, PLUMBING, MECHANICAL, ACCESSIBILITY, ELECTRICAL, ENERGY, LIFE SAFETY AND FIRE CODES — CHANGES OF OCCUPANCY ARE GOVERNED BY FBC EXISTING BUILDING CODE, CHAPTER 10 NOT 9 ** ENGINEER TO MODIFY ALL NOTES ON PLANS REFERRING TO THE 2010 FBC TO 2014 FBC 8119/2015 Comment: THE PLANS ARE JUST COPIES AND NOT SEALED * ALL PLANS MUST BE ORIGINAL FORMAT, SIGNED, SEALED AND DATED BY THE DESIGN PROFESSIONAL PER F.S. 471.025 8/19/2015 Comment: SUBMIT [ 3 ] COMMERCIAL ENERGY CALCULATIONS DESIGNED TO THE 2014 ENERGY CODES W/ MANUAL N'S FOR THE EQUIPMENT DESIGNS 8119/2015 Comment: SUBMIT 2 PDF DISCS UPON RE-SUBMiTTAL 811912015 Comment: DESIGN THE TIE DOWNS FOR THE EXTERIOR MECHANICAL EQUIPMENT PER FBCM 301.15 811912015 Comment: DESIGN PROFESSIONAL TO INCLUDE AN INTERIOR FINISH TABLE ON PLANS FOR ALL INTERIOR FINISHES PER FBC CHAPTER 8 [ SEE TABLE 803.9 ] 804.2 FOR FLOOR COVERINGS 8/19/2015 Comment: SHOW THE FIXED SEATING AT 1 PERSON FOR 18- OF LENGTH [ SEE FBC 1004 RE -CALCULATE THE OCCUPANTLOADS 8/1912015 Comment: ENGINEER TO NOTE ON PLANS REGARDING THE ADDITIONAL LIVE AND DEAD LOADING IMPOSED ON THE TRUSS B0170M CHORDS OF THE MECHANICAL EQUIPMENT a/24/2015 Comment: COMMENTS E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 711412015 711412015 7/1412015 Comment: