Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEJ Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 SGANNED Certification for Design Load Compliance BY Project Name: Tarpon Flats Community Dock (Tract A) St. Lucie County Project Address: 951 Tarpon Flats Dr, Fort Pierce, FL 34949 Permit#: 1507-0176 Construction Type: Dock INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: • New Residences (single or multi -family) VA P7 • Residential Addition • Any accessory structure requiring a building permit FILE GOry • Any non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGNCODE: Florida Building Code Fifth Edition with 20 14 Supplements usingJSCE 7-10 2. Structure Designed as (ch-1, one): _Enclosed Partially E11L1UbUU 0 �jy n 3. Risk Category: _1 wil III IV posure Category: _13 C V D 4. Design Wind Velocity 160 mph — ASD 14*P.LRFD End Zone Width: - N/A ft 5. Mean Roof Height 3 ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sqft @ 15'MRH, clearly label on all plan openings): N/A Zone 1: Zone 2: Zone 3: Zone4: Zone 5: Garage: _ 7. Design Loads: Floor: 141A PSF Roof/Dead: NIA PSF Roof/Live: NIA Balcony: N/A PSF I Dock: 100 PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings':. 50 PLr PSF 8. Were Shear Walls Considered ForStructure? Yes VNot Applicable Explain Why Not: Post supported, moment resistant % � 9. Is A Continuous Load Path Provided? V Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 1500 LB EA V�llp Sol[ Test Reports Submitted? �/Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: William P. Stoddard, Ph.D., P.E. 57605 Print Name Cent # & Co. Cert Auth. Schulke, Bittle & Stoddard, LLC 21 2015 1717 Indian River Blvd, Suite 201, Vero Beach, FL 32960 Signature, �ate, an�d Seal Company Name &Address Revised 07/i�/2014