Loading...
HomeMy WebLinkAboutSTRUCTURAL ANALYSIS REPORTST LUCIE COUNTY PLAN REVIEW 4V 7-- Q 9V6? CROWN Date: August18,2015 BLD ? G: cc CASTLE Jeremy Henson DATE: 6-21 Crown Castle Crown Castle ELEC: -Clo— 2000 Corporate Drive 12725 Morris Road Extension, Suite 400 DATE: Canonsburg, PA 15317 Alpharetta, GA 30004 PLUMB: (724) 416-2000 SCANNED Subject: Structural Analysis Report DATE: BY MECH: St. Lucie Courity Carrier Designation: Veri roffiffoss Co-Locite Carricir Site Number: 68887 Carrier Site Name: Crown Beths Song Crown Castle Designation: Crown Castle BU Number: 5800427 Crown Castle Site Name: Beth's Song Crown Castle JDE Job Number: 288905 Crown Castle Work Order Number: 776147 Crown Castle Application Number: 246590 Rev.0 Engineering Firm Designation: Crown Castle Project Number: 776147 Site Data: 6425 Russakis Road, Fort Pierce, St. Lucie County, FL Latitude 270 33'4.45", Longitude -800 25'23.92" 129 Foot - Monopole Tower Dear Jeremy Henson, Crown Castle is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 776147, in accordance with application 246590, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Existing + Proposed Equipment Note: See Table I and Table 11 for the proposed and existing loading, respectively. Sufficient Capacity This analysis has been performed in accordance with the 2014 Florida Building Code, 5 1h Edition, based upon an ultimate 3-second gust wind speed of 160 mph converted to a nominal 3-second gust wind speed of 124 mph per Section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category 11 were used in this analysis. All modifications and equipment proposed in this report shall be installed in accordance with the attached drawings for the determined available structural capacity to be effective. We at Crown Castle appreciate the opportunity of providing our conuflmingC i es to you and Crown Castle. If you have any questions or need furthe th orQpr )Jcts please give us a call. mlincrA Structural analysis prepared by: R abhLP9 Jofin Kazmierczak, E.I.T. m ......... IV Respectfully submitted by::: �j 0, o 72139 Andrew Joseph Fandozzi III, RE. Professional Engineer License: #72132 Andrew J. Fandozzi, P. E. Z Engineering Supervisor S1 SYATE OF :(UZ Crown Castle USA, Inc. Certification of Authorization #28970 tnxTower Report - version 6.1.4.10* AUG 1 8 20 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 - Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations June 13, 2014 CCI SU No 5800427 Page 2 tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 1) INTRODUCTION June 13, 2014 CCI BU No 5800427 Page 3 This tower is a 129 ft Monopole tower designed by Nello Corporation in December of 2010. The tower was originally designed for a wind speed of 140 mph per TIA-222-G. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 124 mph with no ice and 60 mph under service loads, exposure category C. Table 1 - Proposed Antenna and Cable Information Mount . can er I Line I i Antenna -1 $ ' Nymberl 1 Feed i ing Level (ft)' Elevation 1 of Manufacturer Antenna Model ofFeddi Line Note! Antennas Lines lqize(in)! 6 X7CAP-665 w/ Mount 116 116 css Pipe 18 1-5/8 I tower mounts T-Arm Mount [TA 602-3] Table 2 - Existing Antenna and Cable Information Mounting Level (ft)! Center Line Elevation Number, Of Antennas Antenna I Manufacturer Antenna Model I Number of"Fc - ; ied Lines Feed; - - Line Size (in)l 6 andrew 641280-DF 6 andrew ETD819H-12UB 6 ericsson RRUS-11 127 127 12 4 2 1-5/8 3/8 3/4 1 6 kathrein 1800 10122 w/ Mount Pipe 1 3 1 kathrein 1800 10765 w/ Mount Pipe 12 kathrein 86010025 1 raycap DC648-60-18-8F I tower mounts JPlatforrn Mount [LP 303-11 Notes: 1) Existing Equipment Table 3 - Design Antenna and Cable Information Center i Number Nurriber� Feed Mounting Line I - of i I Antenna -Antenna Model of Feed Line Level (ft); evation.: - Antennas Manufacturer Lines Size (in)� 129 129 - 85 CaAa 12 1-5/8 12 antel RWA-80017 119 119 12 1-5/8 6 ericsson KRY 112-71 12 ante[ RWA-80017 109 109 12 1-5/8 6 ericsson KRY 112-71 tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 3) ANALYSIS PROCEDURE Table 4 - Documents Provided June 13, 2014 CCI SU No 5800427 Page 4 Document Remarks Reference Source 14-GEOTECHNICAL REPORTS I Universal Engineering Sciences 2884524 CCISITES 4-TOWER FOUNDATION RWH Engineering, Inc. 2884526 CCISITES DRAWINGS/DESIGNISPECS 4-TOWER MANUFACTURER Nello Corporation 2888139 CCISITES DRAWINGS 3.1) Analysis Method tnxTower (version 6.1.4.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Crown Castle should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Section No. I Elevation (ft) I corr iponent I size c ritical Element I P (K) SF*P_a llov� (K) .1. � apacity I C I Pass I Fail Ll 1 129-95.75 Pole TP31.1967x22xO.25 1 -6.70 1674.04 35.9 Pass L2 195.75 - 46.75 1 Pole TP44.0621 x29.5903xO.37,9 2 -16.84 3609.99 43.1 Pass L3 46.75-0 Pole TP56.0553x4l.7424.4375 3 -34.56 5348.55 46.9 Pass ISummaryl Pole (1-3) 46.9 Pass Rating = 46.9 Pass Table 6 - Tower Component Stresses vs. Capacity — LC5 Notes Component Elevation (ft) % Capacity PASS Ir Fail 1 Anchor Rods 0 39.5 Pass I Base Plate 0 26.3 Pass 1 Base Foundation 0 36.5 Pass 46.9% S tructureRating (max from all components) J Notes: See additional documentation in "Appendix C — Additional Calculations" for calculations supporting the % capacity consumed. tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 4.1) Recommendations June 13, 2014 CCI BU No 5800427 Page 5 The tower and its foundation have sufficient capacity to carry the existing and proposed loads. No modifications are required at this time. tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 APPENDIX A TNXTOWER OUTPUT June 13, 2014 CCI BU No 5800427 Page 6 tnxTower Report - version 6.1.4.1 no a I 9518 ft 46.8 ft 0.0 It DESIGNED APPURTENANCE LOADING TYPE ELEVATION ELEVATION TYPE ELEVATION (2) 800 10M W/ Mount Pipe 127 (4) 860 10025 127 (2) 600 10M W1 MoUnt Pipe 127 (2) "U&ll 127 (2) am loluwl Mount Pipe 127 (2) piptus.11 127 80 10765wi Mount Pipe 127 (2) plaus.11 127 800 10765WI Mount Pipe 127N 127 800 10765W1 Mount Pipe 127 v xy Pipe Mo= 127 (2) IFTE6191+12US 127 V. 7 Pip. Mtnno 127 (2) Fllelli)�IWB 127 v x T Pipe Mount 127 (2) FTD(119�121JS 127 Pl,ftf.. MOW [-P 30cl] 127 (2) 641280-DF 127 (2) X7CAP-665 W M..M Pip. 116 127 1(2) X7�5 .1 Mount Pip. 116 �12"1120 (2 2E..F 1127 1(2) MAP-1365 .1 Mount Pipe 1116 (4) 'bs' 1127 1 T-Annt Mourd [TA 602-31 1116 1127 MATERIAL STRENGTH F Put GRADE Fy �Fu OW FA. 1. i TOWER DESIG& NOTES 1. Tower is located in Saint Lucia CountA Florida. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 124 mph basic vAnd in accordance with the TIA-222-G Standard. 4. Deflections am based upon a 60 mph wind. 5. Tower Structure Class 11. 6. Topographic Category 1 with Crest Height of 0' 7. TOWER RATING: 46.9% ALL REACTIONS AREFACTORED AXIAL 35K HEA,r�� MOMENT 3 K 2831 kIs-ft TORQUEOkip-H REACTIONS - 124 mph WIND ARM, We No Sol[A.n. Crown Castle 2000 Corporate Drive Canonsburg, PA 15317 Phone: (724) 416-2000 FAX: (724) 416-2254 Job: BU #5800427 Pmfl� client LA Dawn br,, Kazmmrc::a Abed: "e': �l 722Z-7'j 061 13/14 NITS Pth: X%ENG �A—U�—MSBNI�M980UV M I 1�9 No. E_1 June 13, 2014 129 Ft Monopole Tower Structural Analysis CCI BU No 5800427 Project Number 776147, Application 246590, Revision 0 Page 7 Tower Input Pata There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: 2) Tower is located in Saint Lucie County, Florida. 3) Basic wind speed of 124 mph. 4) Structure Class 11. 5) Exposure Category C. 6) Topographic Category 1. 7) Crest Height 0'. 8) Deflections calculated using a wind speed of 60 mph. 9) A non -linear (P-delta) analysis was used. 10) Pressures are calculated at each section. 11) Stress ratio used in pole design is 1. 12) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered, Consider Moments - Legs Consider Moments - Hoflzontals Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC.6D+W Combination Options Distribute Leg Loads As Uniform Assume Legs Pinned Assume Rigid Index Plate Use Clear Spans For Wnd Area Use Clear Spans For KUr Retension Guys To Initial Tension Bypass Mast Stability Checks Use Azimuth Dish Coefficients Project Wind Area of Appurt. Autocalc Torque A" Areas SIR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Use TIA-222-G Tension Splice Capacity Exemption Treat Feedline Bundles As Cylinder Use ASCE 10 X-Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA' SIR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation 4 Consider Feedline Torque Include Angle Block Shear Check ,Fol �s `-Include Shear -Torsion Interaction Always Use Sub-Ciffical Flow Use Top Mounted Sockets I - I Japered Pole SectionGeometry -I Section Elevation Section Splice Number TOP Bottom wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft it Sides in in in in Ll 129'-95'9" 33'3" 4� 18 22.0000 31.1967 0.2500 1.0000 A572-65 (65 ksi) L2 95'9"-46-9" 53' 5191, 18 29.5903 44.0621 0.3750 1.5000 A572-65 (65 ksi) L3 46'9"-0' 52'6" 18 41.7420 56.0553 0.4376 1.7500 A572-65 (65 ksi) I - Tapered Pole Properties 31.6780 24.5562 2971.1694 10.9861 15.8479 187.4800 5946.2484 12.2804 5.0506 20.202 L2 31.1559 34.7735 3749.7994 10.3714 16.0319 249.4563 7504.5328 17.3901 4.5479 12.128 44.7418 51.9986 12538.202 15.5089 22.3835 560.1526 25092.903 26.0042 7.0949 18.92 tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 June 13, 2014 CCI BU No 5800427 Page 8 Section Tip Dia. Area r C I/C J lt/Q w W/f in in 2 in' in in in' m4 in 2 in 8 7 1-3 43.9778 57.3565 12362.778 14.6631 21.2050 583.0135 24741.824 28.6837 6.5766 15.032 8 9 56.9200 77.2323 30183.100 19.7443 28.4761 1059.9453 60405.916 38.6235 9.0957 20.79 4 5 Tower Gusset Gusset Gusset GradeAdjust, Factor Adjust Weight Mult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt (per fa ce) Ar Spacing Spacing Diagonals Honzontals 1-1 129-95'9" 1 1 1 L2 95'9"-46'9" 1 1 1 1-3 46'9"-0' 1 1 1 I - Feed Line/LinkarApplurtenances - Entered As Rbund Or Flat Description Face Allow Component Placement Total Number Clear VVidthor Petimete Weight or Shield Typ a Number PerRow Spacing Diamete r Leg it in r fill Fe(ad Une/Unear Appurtenan6es T Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg it ft2lft pit LDF7-50A(I-5/8") C No Inside Pole 127'- 0' 12 No Ice 0.00 0.82 840 10414( 3/8) C No Inside Pole 127'- 0' 3 No Ice 0.00 0.00 1`13-1989-034- C No Inside Pole 127- 0' 1 No Ice 0.00 0.05 XXXXXX(3/8") WR-VG86ST-BRD( C No Inside Pole 127'- 0' 2 No Ice 0.00 0.59 314) AVA7-50(1-5/8) B No Inside Pole 116'- 0' 18 No Ice 0.00 0.70 I Feed Line/Linear APplurtenance- s Section Areas I Sectio Elevation n it in a 0.000 0.000 0.000 0.000 0.26 C 0.000 0.000 0.000 0.000 0.35 1-2 95'9"-46-9" A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.62 C 0.000 0.000 0.000 0.000 0.54 1-3 46'g'-O' A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.59 C 0.000 0.000 0.000 0.000 0.52 I I Feed Line Center of Pressure, I tnxTower Report - version 6.1.4.1 June 13, 2014 129 Ft Monopole Tower Structural Analysis CC/ BU No 5800427 Froject Number 776147, Application 246590, Revision 0 Page 9 CPZ Section Elevation CPX CFZ CPX Ice Ice ft in in in in 1-1 129'-95'9" 0.0000 0.0000 0.0000 0.0000 1-2 95-9"-46'9" 0.0000 0.0000 0.0000 0.0000 L3 46'9"-0' 0.0000 0.0000 0.0000 0.0000 'Shielding_ Factor Ka.. Tower FeedUne Description Feed Line K� 0 Section I Record I I Segment I No Ice T-K Ice Elev. Discrete Tower Loads Weight Description Face Offset Offsets: Azimuth Placement CAAA CAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert It ft III it, K ft ft (2) 800 10122 wl Mount A From Leg 4.00 0.0000 127' No Ice 7.86 6.65 0.09 Pipe 0. 0. (2) 800 10122 w/ Mount B From Leg 4.00 0.0000 127' No Ice 7.86 6.65 0.09 Pipe 0. 0. (2) 800 10122 w/ Mount C From Leg 4.00 0.0000 127' No Ice 7.86 6.65 0.09 Pipe 0. 0. 800 10765 w/ Mount Pipe A From Leg 4.00 0.0000 127' No Ice 8.90 6.72 0.08 0. 0, 800 10765 wl Mount Pipe B From Leg 4.00 0.0000 127' No Ice 8.90 6.72 0.08 0, 0. 800 10765 w/ Mount Pipe G From Leg 4.00 0.0000 127' No Ice 8.90 6.72 0.08 0. 0. (2) ETD819H-12UB A From Leg 4.00 0.0000 127' No Ice 1.53' 0.39 0.02 0. 0. (2) ETD819H-12UB B From Leg 4.00 0.0000 127' No Ice 1.53 0.39 0.02 01 0. (2) ETD819H-12UB C From Leg 4.00 0.0000 127' No Ice 1.63 0.39 0.02 0. 0. (2) 641280-DF A From Leg 4.00 0.0000 127' No Ice 0.14 0.18 0.00 0. 0. (2) 641280-DF B From Leg 4.00 0.0000 127' No Ice 0.14 0.18 0.00 01 0, (2) 641280-DF C From Leg 4.00 0.0000 127' No Ice 0.14 0.18 0.00 0, 0. (4) 860 10025 A From Leg 4.00 0.0000 127' No Ice 0.16 0.14 0.00 0. 0. (4) 860 10025 B From Leg 4.00 0.0000 127' No Ice 0.16 0.14 0.00 0. 0. tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 77614 7, Application 246590, Revision 0 June 13, 2014 CCI BU No 5800427 Page 10 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Typ a Horz Adjustmen Front Side Leg Lateral t Vert it it it, ft2 K it it (4) 860 10025 C From Leg 4.00 0.0000 127' No Ire 0.16 0.14 0.00 0. 0. (2) RRUS-1 I A From Leg 4.00 0.0000 127' No Ice 3.25 1.37 0.05 0. 0. (2) RRUS-1 1 B From Leg 4.00 0.0000 127' No Ice 3.25 1.37 0.05 0, 0. (2) RRUS-1 I C From Leg 4.00 0.0000 127' No Ice 3.25 1.37 0.05 0. 0. DC6-48-60-18-8F B From Leg 4.00 0.0000 127' No Ice 1.27 1.27 0.02 0, 0, 5'x 2" Pipe Mount A From Leg 4.00 0.0000 127' No Ice 1.00 1.00 0.03 0, Vx 2" Pipe Mount B From Leg 4.00 0.0000 127' No Ice 1.00 1.00 0.03 01 0, 5'x 2" Pipe Mount C From Leg 4.00 0.0000 127' No Ice 1.00 1.00 0.03 0. 01 Platform Mount (LP 303-11 C None 0.0000 127' No Ice 14.66 14.66 1.25 (2) X7CAP-665 wi Mount A From Leg 4.00 0.0000 116' No Ice 8.99 6.95 0.06 Pipe 0. 0. (2) X7CAP-665 wi Mount B From Leg 4.00 0.0000 116' No Ice 8.99 6.95 0.06 Pipe 0. 0. (2) X7CAP-665 wl Mount C From Leg 4.00 0.0000 116' No Ice 8.99 6.95 0.06 Pipe 0. 0. T-Arm Mount [TA 602-3] C None 0.0000 116, No Ice 11.59 11.59 0.77 I Lo ad Combinations I Comb. Description 2 1.2 Dead+1.6 V%And 0 deg - No Ice 3 0.9 Dead+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 30 deg - No Ice 5 0.9 Dead+1.6 Wind 30 deg - No Ice 6 1.2 Dead+1.6 Wind 60 deg - No Ice 7 0.9 Dead+1.6 Wind 60 deg - No Ice 8 1.2 Dead+1.6 Wind 90 deg - No Ire 9 0.9 Dead+1.6 Wind 90 deg - No Ice 10 1.2 Dead+1.6 Wind 120 deg - No Ice 11 0.9 Dead+1.6 Wind 120 deg - No Ice 12 1.2 Dead+1.6 Wind 150 deg - No Ice 13 0.9 Dead+1.6 Wind 150 deg - No Ice 14 1.2 Dead+1.6 Wind 180 deg - No Ice is 0.9 Dead+1.6 Wtnd 180 deg - No Ice 16 1.2 Dead+1.6 Wind 210 deg - No Ice 17 0.9 Dead+1.6 Wnd 210 deg - No Ice tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 Comb. Description No. 18 1.2 Dead+1.6 Wind 240 deg - No Ice 19 0.9 Dead+1.6 Wind 240 deg - No Ice 20 1.2 Dead+1.6 Wind 270 deg - No Ice 21 0.9 Dead+1.6 Wind 270 deg - No Ice 22 1.2 Dead+1.6 Wind 300 deg - No Ice 23 0.9 Dead+1.6 Wind 300 deg - No Ice 24 1.2 Dead+1.6 Wind 330 deg - No Ice 25 0.9 Dead+1.6 Wind 330 deg - No Ice 26 Dead+Wind 0 deg - Service 27 Dead+Wind 30 deg - Service 28 Dead+Wnd 60 deg - Service 29 Dead+Wjnd 90 deg - Service 30 Dead+Wnd 120 deg - Serrice 31 Dead+Wind 150 deg - SerVice 32 Dead+Wjnd 180 deg - Service 33 Dead+Wnd 210 deg -Service 34 Dead+Wnd 240 deg - Service 35 Dead+Wind 270 deg - Service 36 Dead+Wind 300 deg - Service 37 Dead+WLnd 330 deg - Service Maximum Member ForceS June 13, 2014 CCI BU No 5800427 Page I I Sectio Elevation Component Condition Gov. Axial MajorAxis MmorAxis n it Type Load Moment Moment No. Comb. K klo-ft kia-ft Ll 129-95.75 Pole Max Tension 20 0.00 -0.00 0.00 Max. Compression 22 -6.70 314.84 181.78 Max. Mx 8 -6.70 -363.77 -0.05 Max. My 14 -6.70 -0.09 -363.73 Max. Vy 8 16.89 -363.77 -0.05 Max. Vx 14 16.89 -0.09 -363.73 Max. Torque 5 -0.49 L2 95.75- Pole Max Tension 1 0.00 0.00 0.00 46.75 Max. Compression 22 -16.84 1153.02 665.70 Max. Mx 8 -16.84 -1331.62 -0.06 Max. My 14 -16.84 -0.10 -1331.57 Max. Vy 8 24.28 -1331.62 -0.06 Max. Vx 14 24.28 -0.10 -1331.57 Max. Torque 5 -0.49 L3 46.75-0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 20 -34.56 2830.90 -0.06 Max. Mx 8 -34.56 -2831.11 -0.06 Max. My 14 -34.56 -0.10 -2831.07 Max. Vy 8 32.66 -2831.11 -0.06 Max. Vx 14 32.66 -0.10 -2831.07 Max. Torque 5 -0.49 I Maximum Reactions I Location Condition Gov. vertical Horizontal, X Horizontal, Z Load K K K Comb. Pole Max. Vert 8 34.58 -32.64 0.00 Max. H. 20 34.58 32.64 0.00 Max. H. 2 34.58 0.00 32.64 Max. MX 2 2830.94 0.00 32.64' Max. M. 8 2831.11 -32.64 0.00 Max. Torsion 17 0.49 16.32 -28.26 Min. Vert 17 25.93 16.32 -28.26 Min. H. 8 34.58 -32.64 0.00 Min. H. 14 34.58 0.00 -32.64 tnxTower Report - version 6.1.4.1 June 13, 2014 129 Ft Monopole Tower Structural Analysis CCI BU No 5800427 Project Number 776147, Application 246590, Revision 0 Page 12 Location Condition Gov. Vertical Horizontal, X Horizontal, Z Load K K K Comb. Min. M. 14 -2831.07 0.00 -32.64 Min. M. 20 -2830.90 32.64 0.00 Min. Torsion 5 -0.49 -16.32 28.26 I , Tower Mast Reaction SUmmary Load Vertical Shear, Shear, Overturning Overturning Torque Combination Moment, M. Moment, M, K K K kic-ft kip-ft iop-ft Dead Only 28.82 0.00 0.00 0.05 -0.09 0.00 1.2 Dead+1.6 Wind 0 deg - 34.58 0.00 -32.64 -2830.94 -0.10 0.42 No Ice 0.9 Dead+1.6 Wind 0 deg - 25.93 0.00 -32.64 -2819.28 -0.08 0.42 No Ice 1.2 Dead+1.6 Wind 30 deg - 34.58 16.32 -28.26 -2451.66 -1415.61 0.49 No Im 0.9 Dead+1.6 Wind 30 deg - 25.93 16.32 -28.26 -2441.56 -1409.74 0.49 No Ice 1.2 Dead+1.6 Wind 60 deg - 34.58 28.26 -16.32 -1415.44 -2451.83 0.42 No Ice 0.9 Dead+1.6 Wind 60 deg - 25.93 28.26 -16.32 -1409.62 -2441.68 0.42 No Ice 1.2 Dead+1.6 Wind 90 deg - 34.58 32.64 0.00 0.06 -2831.11 0.24 No Ice 0.9 Dead+1.6 Wind 90 deg - 25.93 32.64 0.00 0.05 -2819.40 0.24 No Ice 1.2 Dead+1.6 Wind 120 deg 34.58 28.26 16.32 1415.56 -2451.83 0.00 - No Ice 0.9 Dead+1.6 Wind 120 deg 25.93 28.26 16.32 1409.71 -2441.68 0.00 - No Ice 1.2 Dead+1.6 Wind 150 deg 34.58 16.32 28.26 2451.78 -1415.61 -0.24 - No Ice 0.9 Dead+1.6 Wind 150 deg 25.93 16.32 28.26 2441.65 -1409.74 -0.24 - No Ice 1.2 Dead+i.6 Wind 180 deg 34.58 0.00 32.64 2831.07 -0Ao -0.42 - No Ice 0.9 Dead+1.6 Wind 180 deg 25.93 0.00 32.64 2819.37 -0.08 -0.42 - No Ice 1.2 Dead+1.6 Wind 210 deg 34.58 -16.32 28.26 2451.78 1415.40 -0.49 - No Ice 0.9 Dead+1.6 Wind 210 deg 25.93 -16.32 28.26 2441.65 1409.58 -0.49 - No Ice 1.2 Dead+1.6 Wind 240 deg 34.58 -28.26 16.32 1415.56 2451.62 -0.42 - No Ice 0.9 Dead+1.6 Wind 240 deg 25.93 -28.26 16.32 1409.71 2441.53 -0.42 - No Ice 1.2 Dead+1.6 Wind 270 deg 34.58 -32.64 0.00 0.06 2830.90 -0.24 - No Ice 0.9 Dead+1.6 Wind 270 deg 25.93 -32.64 0.00 0.05 2819.24 -0.24 - No Ice 1.2 Dead+1.6 Wind 300 deg 34.58 -28.26 -16.32 -1415.44 2451.62 0.00 - No Ice 0.9 Dead+1.6 Wind 300 deg 25.93 -28.26 -16.32 -1409.62 2441.53 0.00 - No Ice 1.2 Dead+1.6 Wind 330 deg 34.58 -16.32 -28.26 -2451.66 1415.40 0.24 - No Ice 0.9 Dead+1.6 Wind 330 deg 25.93 -16.32 -28.26 -2441.56 1409.58 0.24 - No Ice Dead+Wnd 0 deg - Service 28M 0.00 -4.27 -369.77 -0.09 0.06 Dead+\Afind 30 deg - Service 28.82 2.14 -3.70 -320.23 -185.00 0.06 Dead+Wnd 60 deg - Service 28.82 3.70 -2.14 -184.86 -320.36 0.06 Dead+Wnd 90 deg - Service 28.82 4.27 0.00 0.05 -369.91 0.03 Dead+Wnd 120 deg - 28.82 3.70 2.14 184.96 -320.36 0.00 Service Dead+\Arind 150 deg - 28.82 2.14 3.70 320.33 -185.00 -0.03 tnxTower Report - version 6.1.4.1 Er 0 m ---------- �M�mm,wm p N P:� p p p �4 �' �4 p N P:� p N p PPPOPPOPPOPIPOP�Plp. �n. �n. & -� 6 �) p P:� p p 1,1 i� �4 �� n � " o � � 4 n � � 0 0 �a M"Mm� I- I � � -.� � -.R � -.� .� � �R .� -.� -.� I.R � � 'D >7 -0 . 57 �R rn o0wowomowomou b� b� bD bD :-L L4 iQ �4 b 6 4) 0 � w � p m n w w w m m m w % I p p p .6 6 6 2 om C� � 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 2 Yes 4 0.00000001 0.00004119 3 Yes 4 0.00000001 0.00002453 4 Yes 5 0.00000001 0.00002427 5 Yes 4 0.00000001 0.00075325 6 Yes 5 0.00000001 0.00002336 7 Yes 4 0.00000001 0.00072548 8 Yes 4 0.00000001 0.00002530 9 Yes 4 0.00000001 0.00001494 10 Yes 5 0.00000001 0.00002378 11 Yes 4 0.00000001 0.00073807 12 Yes 5 0.00000001 0.00002402 13 Yes 4 0.00000001 0.00074560 14 Yes 4 0.00000001 0.00004119 15 Yes 4 0.00000001 0.00002453 16 Yes 5 0.00000001 0.00002330 17 Yes 4 0.00000001 0.00072353 Is Yes 5 0.00000001 0.00002420 19 Yes 4 0.00000001 0.00075106 20 Yes 4 0.00000001 0.00002530 21 Yes 4 0.00000001 0.00001494 22 Yes 5 0.00000001 0.00002376 23 Yes 4 0.00000001 0.00073775 24 Yes 5 0.00000001 0.00002353 25 Yes 4 0.00000001 0.00073046 26 Yes 4 0.00000001 0.00000001 27 Yes 4 0.00000001 0.00000001 28 Yes 4 0.00000001 0.00000001 29 Yes 4 0.00000001 0.00000001 30 Yes 4 0.00000001 0.00000001 31 Yes 4 0.00000001 0.00000001 32 Yes 4 0.00000001 0.00000001 33 Yes 4 0.00000001 0.00000001 34 Yes 4 0.00000001 0.00000001 35 Yes 4 0.00000001 0.00000001 36 Yes 4 0.00000001 0.00000001 37 Yes 4 0.00000001 0.00000001 I Maximum Tower Deflections -Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load Ll 129-95.75 6.590 30 0.4618 0.0006 L2 99.75 - 46.75 3.923 30 0.3819 0.0002 L3 52.5-0 1.055 30 0.1867 0.0001 June 13, 2014 CCI BU No 5800427 Page 14 Critical Deflections and Radius of Curvature -Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvatum IFAMAI� Maximuin Towe r Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load It in Comb. Ll 129-95.75 50.414 8 3.5319 0.0046 tnxTower Report - version 6.1.4.1 June 13, 2014 129 Ft Monopole Tower Structural Analysis CCI BU No 5800427 Project Number 776147, Application 246590, Revision 0 Page 15 Section Elevation Horz. Gov. rift Twist NO. Defiection Load ft in Comb. L2 99.75 - 46.75 30.021 8 2.9232 0.0017 L3 52.5-0 8.073 8 1.4290 0.0006 I - Critical.Deflections and Radius of Curvature - Design Wind I Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft _Compression Checks. Pole Design Data Ratio Section Elevation size L L� KI1r A P� No. P� it ft ft & K K �P, LI 129-95.75 TP3-t.1967x22xO.25 33-Y 0.0 23.678 -6.70 1674.04 0.004 (1) 3 L2 95.75-46.75 TP44.062149.69034.37 53' 0. 0.0 50.129 -16.84 3609.99 0.005 (2) 5 8 0 46.75-0(3) TP56.0553x4l.7420.437 52'6" 0, 0.0 77.232 -34.56 5348.55 0.006 5 3 I � - Pole Bending Design Data I- I Section No. Elevation it Size M�, kip-n �M�� kip -It Ratio M. �M.�- MW klp-ft �Mny kip-ft Ratio M� -�Mn, Ll 129-95.76 TP31.1967x22xO.25 363.79 1026.69 0.354 0.00 1026.69 0.000 (1) L2 95.75-46.75 TP44.062U29.59030.37 1331.63 3123.25 0.426 0.00 3123.25 0.000 (2) 5 L3 46.75-0(3) TP56.0553x4l.742xO.437 2831.13 6117.02 0.463 0.00 6117.02 0.000 5 I - Role Shear Design Delta Section Elevation size Actual �Vn Ratio Actual �Tn Ratio No. V. V� T. T. ft K K --jCv- kip-ft kJo-ft AT- (1) L2 95.75-46.75 TP44.062149.590W.37 24.28 1804.99 0.013 0.00 6254.13 0.000 (2) 5 U 46.75-0(3) TP56.0553x4l.742xO.437 32.66 2674.28 0.012 0.00 12249.00 0.000 5 tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 I Pole Interaction Desigh Data June 13, 2014 CCI BU No 5800427 Page 16 Section No. Elevation IT Ratio P� Wn Ratio M.� OM,� Ratio MW W, Ratio V. W� Ratio T� —TTT— Comb. Stress Ratio Allow. Stress Ratfo Criteria Ll 129-95.75 0.004 0.354 0.000 0.020 0.000 0.359 1.000 (1) V 4.8.29/ L2 95.75 - 46.75 0.005 0.426 0.000 0.013 0.000 0.431 1.000 (2) V 4.8.2 L3 46.75-0(3) 0.006 0.463 0.000 0.012 0.000 0.469 1.000 V 4.8.2 Section Capacity Table Section Elevation Component Size Critical P op.,� % Pass No. it Type Element K K Capacity Fail LI 129-95.75 Pole TP31.1967x22xO.25 1 -6.70 1674.04 35.9 Pass L2 95.75 - 46.75 Pole TP44.0621)(29.5903XO.375 2 -16.84 3609.99 43.1 Pass L3 46.75-0 Pole TP56.0553x4l.742xO.4375 3 -34.56 5348.55 46.9 Pass Summary Pole (1-3) 46.9 Pass RATING = 46.9 Pass tnxTower Report - version 6.1.4.1 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 APPENDIX B BASE LEVEL DRAWING June 13, 2014 CCI BU No 5800427 Page 17 tnxTower Report - version 6.1.4.1 at M.9/;-t w? at OL ED ED 10 0 �ld OLL M.9/9-1 (all (DO 129 Ft Monopole Tower Structural Analysis Project Number 776147, Application 246590, Revision 0 APPENDIX C ADDITIONAL CALCULATIONS June 13, 2014 CCI BU No 5800427 Page 18 tnxTower Report - version 6.1.4.1 Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material Assumption7 Clear space between bottom of leveling nut and top of concrete not exceeding (1)*(Rod Diameter) Site Data BU#: 5800427 Site Name: Beth's Song A "' 246590, Rev. 0 �70'1eTanufacturer: I Other Anchor Rod Data Q ty: Diam: Rod Material: Strength (Fu): Yield (Fy): Bolt Circle: 22, i n ksi ksi in 2.25 A61 5-J 100, 75 63 Plate Data Diam:1 Thick: Grade: —Single-Rod B-eff.P8 69 lin in ksi in Ogg Stiffener Data (Welding at both sides) Config: Weld Type: Groove Depth: Groove Angle: Fillet H. Weld: Fillet V. Weld: Width: Height: Thick: Notch: Grade: Weld str.:rElksi 0 <- Disregard <- Disregard in in in in in in ksi f li- 5 �L; Pole Data Diam: Thick: Grade: of Sides: Fu Reird. Fillet Weld 56,0553 in in ksi "0" IF Round ksi "0" if None 0.4375 65 18 80 0 Reactions k! a Ads�,M'U.J lftk�"ps Shear, Vu� 1 33 1kips Eta Factor, ri 1 0.5 ITIA G (Fig. 4-4 I If No stiffeners, C �Only AppIcable to Unstiffened Cases Anchor Rod Results Max Rod (Cu+ Vu/�): Allowable Axial, (D*Fu*Anet: Anchor Rod Stress Ratio: 102.6 Kips 260.0 Kips 39.5% Pass I Rigid AISC LRFD (p-rn Base Plate Results Flexural Clec k Base Plate Stress: k . 11 8 si I L Allowable Plate Stress: 45.o ksi (P*Fy Base Plate Stress Ratio: 26.3% Pass Y.L. Length: 28.75 1 n1a Stiffener Results Horizontal Weld: n1a Vertical Weld: n1a Plate Flex+Shear, fb/Fb+(fv/Fv)A2: n1a Plate Tension+Shear, ftIFt+(fvfFv)A2: n/a Plate Comp. (AISC Bracket): n/a Pole Results Pole Punching Shear Check: n/a 0 0 0 0 4 3. 0 = none, 1 = every bolt, 2 = every 2 bolts, 3 = 2 per bolt ** Notw. for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CCIplate v2.0 Analysis Date: 6/13/2014 CO Foundation Tool Suite -Monopole Pier -Beta Release CCI Foundation Tool Suite - Y1.0 Date: 6/13/2014 311' 5300427 Site Name: Beth's Song App Number: 246590,Rev.0 WorkOrder: 776147 Monopole Drilled Pier Input itshen. 7 TIARevison: G ACI 318 Revision: 2005 SeismIcCatr,cr,: 8 Forces Compression 35 kips Shear 33 kips moment M31 k-ft Swelling Force D kips Foun ation Dimensions, I Pier Diameter: 7 it E� above grace: I it Depth balceugrade: 45 it ,Matenal Properties, Number of Rebar: 36 Rob.rSbe: 11 Tie Size 5 Rebar tenstle strength: 0 kal ConereteStrar,th: QC0 psl Ultimate Concrete Strain 0.003 In/in Clear Cover to Ties: 4 in 61 C a4"C.C. :,,.,Layer, .11hickmass (fti From (it) To. (w UnitWeight (Pcf) Cohesion (pil Friction Angle (deg) Ultimate W'PlIftskin Friction (es" Ultimate Mk. Co " Skin Fniction (ksf) Ultimate �Boarmg I Capstan, §PT'N" '(Icif) _Co.nt� 1 4 0 4 115 0 0 0 0 0 3-- -4 —7 -25 42.6 0 is 0 ­4 S2.16 __6­__ _25 1i gF3 Analysis Results Sell Lateral Capacity �;_Pifi_t_. -- - - - - - 7 -i-DoW MU Moment, Muo 3103.13 k-ft I Sol] Safety Factor: 6.72 �0qVIFactorReq'd: 1331 Sell �ial Capacity WOFikal6n_(k) ----- - I— _230W kip's End Bearing (k): 532.74 kips C.mp. Capacity (k),,ti0n: 763.57 klps' Ccmp._(k),'Cul 3160 klpa Concrete/Steel Check fK (from soil analysis) 3103.9li-ft--- 8512.91 k4t 'TK&'p­rQdad - _. '— - — '___ - 1-.61-1 jto-q.i�.d ___ _, ., _._ __ 9;n Reber Spacing SFLc[2,fraquL�ed Dav_9n­gUi'Wq'�'md 33.04� Day. Length pTvLd.c! 3.51 Page 1 of I