Field and Laboratory Report Transmittal Sheet
Client: ComStruct Services, Inc
4440 Southeast 53rd Avenue
Ocala, FL 34480 SCANNED
BY
Project: Crown Beths Song Shelter Building St Lucie CoUrIty
Permit # 1506-0523
6425 Russakis Road
Ft. Pierce, FL
As requested, a representative of Universal Engineering Sciences, Inc. (LIES) was at the
referenced project to provide construction materials testing services.
The results of the observations and/or tests are summarized on the attached sheets. The
reports are numbered as follows: 43880 ARD2, 43880 DT1, 43880 DT2, 18552 MP. We trust
this information is sufficient for your immediate needs. If you have any questions, please do not
hesitate to contact the undersigned.
Reviewed By: _�., Ir"
Universal Engineering Sciences, Inc.
: 1�
Certificate ofAuth� zatlonNl"
r i q�,�549
/ichard E. Hoaglin, P.E.
STATE OF FLORIDA'
sm
Licensed Professional Engineer No. 48796
ICC Email: ricky.hunt(dconstructinc.com
ICC Fax: City of Ft. Pierce 772-462-6443
820 Brevard Avenue, Rockledge, Florida 32955 (321) 638-0808 Fax (321) 638-0978
www.UniversalEngineering.com
[ 'k
UNIVE -"SAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering - Environmental Sciences
Geophysical Services - Construction Materials Testing - Threshold Inspection
Building Inspection -Plan Review -Building Code Administration
820 Brevard Avenue - Rockledge, FL - 32955
321.638.0808 Fax: 321.638.0978
Activity Record
UES Proje ' '�D: 0310.1500293.0000
UES Report No: 43880 ARD2 090915
On -Site Time (hrs):
1.00
Lab Time (hrs):
0.00
Travel Time (hrs):
1.00
Total Time (hrs):
2.00
Client: ComStruct Services, Inc
4440 Southeast 53rd Avenue
Ocala, FL 34480
Project: Crown Beths Song Shelter Building
6425 Russakis Road,Ft. Pierce, St. Lucie County, FL
Date of Activity: Wednesday, September 9, 2015
Technician: Cliff Chermay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project
site for the purpose of earthwork testing for the Footing, Building pad.
While on site, the technician observed the general condition of the areas to be tested and performed 1
density test(s) for Footing. All test(s) were performed in accordance with the ASTM D-6938 Nuclear
Gauge Method and were found to meet the project compaction requirements of 95% of the maximum dry
density per ASTM D-1 557.
While on site, the technician observed the general condition of the areas to be tested and performed I
density test(s) for Building pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear
Gauge Method and were found to meet the project compaction requirements of 95% of the maximum dry
density per ASTM D-1 557.
As Requested, a Universal Engineering Sciences Technician was present at the above referenced
location for the purpose of Technician was on site for the purpose of density testing.
This test(s) was performed without deviation from ASTMprocedure.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
1f*AL
UNIVEJA
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering - Environmental Sciences
Geophysical Services - Construction Materials Testing - Threshold Inspection
Building Inspection - Plan Review - Building Code Administration
820 Brevard Avenue - Rockledge, FL - 32955
321.638.0808 Fax: 321.638.0978
In -Place Density Test ReDort
Client: CornStruct Services, Inc
4440 Southeast 53rd Avenue
Ocala, FL 34480
Project: Crown Beths Song Shelter Building
6425 Russakis Road,Ft. Pierce, St. Lucie County, FL
Area Tested: Footing
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method
Lab: ASTM D-1557
Technician: Cliff Chermay
UES Pro,",,, --',No: 0310.1500293.0000
ILIES Report No: 43880 DT1 090915
Date of Test: 09/09/2015
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and
do not address the condition of the underlying soils below the tested depths.
Field Dry
Test
Range
Depth
Proctor
Density
Field
moisture
%
Comments
Location of Test
(FT)
(IN)
(2)
(PCF)
%
Compaction
(3)
I
Footing
0-1
12.00
18552
109.1
15.0
96
A
(1) Ref. Datum: 0 = Bottom of Footing
(2)
Proctor
Maximum
Optimum
Dry
Moisture
Density
Content
18552
114.0
11.0
This test was performed without deviation from ASTMprocedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
UNIVERViAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering -Environmental Sciences
Geophysical Services - Construction Materials Testing -Threshold Inspection
Building Inspection -Plan Review -Building Code Administration
820 Brevard Avenue - Rockledge, FL - 32955
321.638.0808 Fax: 321.638.0978
In -Place Density Test Report
Client: ComStruct Services, Inc
4440 Southeast 53rd Avenue
Ocala, FL 34480
Project: Crown Beths Song Shelter Building
6425 Russakis Road, Ft. Pierce, St. Lucie County, FL
Area Tested: Building pad
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method
Lab: ASTM D-1557
Technician: Cliff Chermay
LIES Proi W o:
LIES Report No:
0310.1500293.0000
43880 DT2 090915
Date of Test: 09/09/2015
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or sufficial soil conditions only and
do not address the condition of the underlying soils below the tested depths.
leld Dry
Test
Range
Depth
Proctor
Density
Field
Moisture
%
Comments
#
Location of Test
[FT)
(IN)
(2)
[PCF)
%
Compaction
(3)
2
Building pad
0-1
12.00
1 18552
108.5
19.0
95
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Proctor
Maximum
optimum
#
Dry
Moisture
Density
Content
18552
114.0
11.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full without the written approval of Universal Engineering Sciences.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering -
Environmental Sciences - Construction Materials Testing
820 Brevard Avenue - Rockledge, Florida 32956 - (321) 638-0808
Client No: 0310.1500293.0000
Date: September 10, 2015
REPORT OF MOISTURE DENSITY RELATIONSHIP OF SOIL
Client: COMSTRUCT SERVICES INC.
4440 SOUTHEAST 53RD AVENUE
OCALA FLORIDA 34480
Project: CROWN BETHS SONG SHELTER BUILDING
6425 RIUSSAKIS ROAD
FORT PIERCE, FLORIDA
Location: NATIVE - PAD
Date Sampled: 9/2/16
Sampled By: CLIFF CHERRNAY
SUMMARY OF TEST RESULTS
0 rn NMI 1111�6 Z It M
mks gqo,. �-I-
0
—
PASSING #200 SIEVE
MEM
MEM
MMEMMMEMM1W
MEMENNOMMEN
=OEM
MMMMMMMM
EMMMMMEMEM
,
ME
=ZMMMEM=MM
ME
EMME1MMM1MMEMM
MEMMMEMMMMMMMM
==MMMMMMEM==
=M1EM=MMME=M=M
PROCTOR NO: 5473
NOTES -This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.