Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 tt CertificationforD sign LoadCompliance ProjectName: Hof" L 'j—f 0 : 1— / P—r,4 (.. , ✓J.� Project Address: 'P;Ye- F . FL 3 �`lSl Permit#: Z/5T Occupancy Type:onstructionType: t V' 1j 'lI INSTRUCTIONS FOR USE: s. This certification must be completed, signed, and sealed by the design professional of record. ((( • Submit (2) copies for residential, (3) copies for commercial with all permit applications Involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition BY o Any accessory structure requiring a building permit St. Lucie County o Any non-residential structure. ' Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. (complete all that apply) 1. DESIGN CODE: Florida fifth edition 2014) dition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): 3f Enclosed _Partially Enclosed Open Main bldg is 3. Risk Category: _I �II _III _ IV Exposure Category: CC- �D• enClOSed; loading 4. Design Wind Velocity 153 mph ASD 1ZLRFD End Zone Width: 4.6 ft dock is open. S. Mean Roof Height 24 ft Roof Pitch: ____E_:12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 1S'MRH, clearly label on all plan openings): Zone 1: 41 Zone 2: F68-1 Zone 3: 102 Zone 4: 38 Zone 5: 46 Garage : 10 7. Design Loads: Floor: 0 PSF Roof/Dead: $ PSF Roof/Live: 20 Balcony: PSF Dock: PSF Deck: PSF Stairs: 100 PSF Fence: PSF Railings - 'PSF' 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: Pre-engineered metal building by Spec Eng with wind frames and x braces. 9. Is A Continuous Load Path Provided? lkf Yes _Not Applicable Explain Why Not: '10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT• I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify t tructural elements depicted on these plans provide adequate resistance to the design forces spe ' Print Name Cert # & Co. Cert Auth. (�i,eoya� �oti�z9 a Signature, Date, and Seal Company Name & Address Revised 07/25/2014