August 19, 2015
To: Planning and Development Services
Building & Code Regulation Division
2300 Virginia Ave
Fort Pierce, FL 34982
Attn: Joe Cicio
Re: Rio Citrus, Inc.
Permit#1507-0355
Metal Building (1 Story)
Response to 8/13/2015 Comments
Dear Mr. Cicio,
SCANNED
By
SL Lucie County
'I ' y
� n
g65O 0�7
P/mz
Please find our responses following your stated comments, along with the requested 3 sets of plans and
2 CD's with PDF files with all information,
1) SUBMIT ORIGINAL SIGNED, SEALED AND DATED ENGINEERED PLANS IN TRIPLICATE FOR THE
PREENGINEERED ALUMINUM ACCESSIBLE RAMP * THESE PLANS MUST BE STAMPED REVIEWED
AND APPROVED BY DESIGN PROFESSIONAL OF RECORD *** SECOND REVIEW / NOT SUBMITTED
*** FEE DUE
Response: EDB Architects will review the shop drawings submitted in triplicate from the
General Contractor and if they are all ok we will mark them with a stamp stating "No
Exceptions Taken". The GC will subsequently provide copies to the Building Department.
2) SUBMIT ORIGINAL, SIGNED, SEALED AND DATED METAL BUILDINGPLANS FROM THE
MANUFACTURER STAMPED APPROVED AND READY FOR CONSTRUCTION FOR REVIEW * THESE
PLANS MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD ***
SECOND REVIEW / M.B.PLANS MUST BE REVIEWED AND APPROVED BY THE DESIGN
PROFESSIONAL OF RECORD BEING EDB ARCHITECTS *** FEE DUE
Response: Upon receipt of shop drawings from the General Contractor, EDB Architects will
have their structural engineering consultant, TRC Worldwide, review and stamp the copies
with their own "Reviewed" and approved information. The General Contractor will
subsequently provide copies to the Building Department.
REC,i -:'I %UG 21'of
3) "PRODUCT REVIEW AFFIDAVITS" ARE INCORRECT OR INCOMPLETE * PRODUCT PRESSURES ARE
INCORRECT * MODEL NUMBER IS NOT PART OF THIS N.O.A. , PRODUCT APPROVAL NUMBER IS
INCORRECT * METHOD OF ATTACHMENT MUST BE FILLED IN AND REQUIRES WELDING *** THE
LINE FOR THE SWING DOOR IS INCOMPLETE *** SUBMITTED TEST IS APPLICABLE TO THE 2001
FBC ??? *** SECOND REVIEW *** FEE DUE *** DID NOT RECEIVE REVISED, SEALED PRODUCT
AFFIDAVITS * ALL PRODUCT APPROVALS MUST BE SELECTED FROM THE 2014 PRODUCT
APPROVAL LIST AND INFORMATION AFFIXED TO THE AFFIDAVIT W/ PRODUCT APPROVALS
ATTACHED * SUBMIT ALL IN TRIPLICATE
Response: This data must be provided by the General Contractor. EDB Architects will assist
him wherever we can, however, all product NOA's must come from the manufacturer selected
by the General Contractor during his pricing out the project.
4) WIND LOAD SHEETS ARE INCOMPLETE* FILL IN EXPOSURE CATEGORY FBC 1609.4 *GARAGE
DOOR LOAD TABLE 16.9.7 * LOADS ON GUARDRAILS FBC 1607.8 *** SECOND REVIEW *** FEE
DUE *** NEED SIGNED, SEALED AND DATED " CERTIFICATION FOR DESIGN LOAD COMPLIANCE "
SHEETS IN TRIPLICATE * THESE MUST BE COMPLETELY FILLED OUT, ORIGINALAND CANNOT BE
ALTERED OR ADDED TO
Response: See attached "Certification for Design Load Compliance", with Risk Category at I,
Exposure B per FBC 1609.4, garage doors 30'x10' per 1609.7(1) with roof angle 0-10 degrees
and 160 mph equates to +21.5, -24.2 psf. A PDF copy of the soils report is also included on CD.
5) MODIFY PLAN NOTES ON A-4 *** WE DO NOT ENFORCE IBC CODES * FBC 2010 AND CODE SITES
ARE NOT CORRECT * PLEASE CITE ALL CODES FROM THE 2014 FBC 5TH EDITION ** DESIGN
PROFESSIONAL TO ADDRESS FBC 2603.3 / EXCEPTION #2 * THIS MATERIAL IS BEING APPLIED AT
6" WHICH FALLS INTO THAT EXCEPTION FOR COLD STORAGE BUILDINGS *** THE INCORRECT
CODE IS STILL BEING CITED ON PLAN SHEET A-4 *** SECOND REVIEW * FEES DUE ***
Response: Sheet A-4 has been revised for compliance with FBC 2014 5t" Edition Code. The
following explains our approach for using Icynene Insulation.
a. FBC 2014 5" Edition (2603.3): Icynene pro -seal MD-C-200V3 spray foam insulation
meets the requirements for flame spread index of not more than 75 (actual is <20 per
ASTM 84) and a smoke development index of not more than 450 (actual <400 per
ASTM E84).
b. FBC 2014 SL" Edition (2603.3 Exception #2): Maximum thickness tested per ASTM E84
was 4" therefor, the thickness specified on the drawings Sheet A-4 has been reduced
to 4" in lieu of 6". The 4" of Icynene MD-C-200V3 has an R-value of 27.0. The energy
code was calculated using R-22.9, therefor we are ok with the reduction in insulation
thickness. (A PDF copy of Energy Code is attached and included on the CD.)
c. FBC 2014 5`" Edition (2603.4): The spray foam is being separated from the interior of
the building by an equivalent thermal barrier using DC315, a spray applied
intumescent coating as manufactured by International Fire Proof Technology, Inc. This
product has been tested to meet UL1715 and NFPA 286 requirements as stipulated in
2603.4 and 2603.10 (Literature attached includes DC315 data, and evaluation report
ESR-3500 for the Icynene Insulation.)
6) PLEASE RE -SUBMIT ALL REQUIRED PLANS AND ASSOCIATED DOCUMENTS IN TRIPLICATE AND
ORIGINAL FORMAT FOR REVIEW * INCLUDE [ 21 PDF DISCS WITH ALL INFORMATION * WILL
SUGGEST A MEETING WITH ALL PROFESSIONALS TO REVIEW THE COMMENT LIST IF NECESSARY
Response: Attached please find all revised plans (and original void sheets) in triplicate as
requested. Also included are (2) two CD's with PDF's of plans and associated data for review. I
don't believe a meeting will be required but I am available for a telephone conversation,
should you need additional clarification.
If you have ions or need additional information, please contact us.
sp fully s it d,
Paul U. Dritenbas, AIA, NCARB, LEED AP
Architect
C:\Mary\040515VB\BldgDeptResponses.docx
r-
Joe Cicio
From: Joe Cido
Sent: Monday, August 17, 2015 8:51 AM
To: 'DTRIPP@TRIPPGROUP.ORG'; Joe Cicio
Cc: 'Russ@riocitrus.com'
Subject: Second Review Comments for permit number 0355
m Attachments: Repo rt_FL_Review_Comments_NoncoIT2rk7
40
St. Lucie County
Dear St. Lucie County Permit Applicant,
Please see the attached plan review comments which have been generated for your permit. As soon as we receive the
modified plans and any additional required documentation back from the design professional, contractor or owner we
will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have
been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to
permitting for permit issuance. �
Thank You,
Plans� &11 61
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
Sf Lvzio& Covm_fy PL&*voi" a*L& DeAret&pwl.R,�Sei vLtzp
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Joe Cicio
From:
Joe Cicio
Sent:
Monday, August 03, 2015 8:56 AM
To:
'DTRIPP@TRIPPGROUP.ORG'
Cc:
Joe Cicio
Subject:
Review Comments for Permit Number 1507-0355
SCANNED
Attachments:
Repo rt_FL_Review_Comments_Noncompliantjrf.pdf
BY
St. Lucie County
Dear St. Lucie County Permit Applicant,
Please see the attached plan review comments which have been generated for your permit. As soon as we receive the
modified plans and any additional required documentation back from the design professional, contractor or owner we
will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have
been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to
permitting for permit issuance.
Thank You,
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
St L-v4, - Covwwhy PL&vwA " a.K& D�Servi cey
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Joe Cicio
From: Joe Cicio SCANNED
Sent: Monday, August 31, 2015 3:20 PM BY
To: 'Russ@ riocitrus.com'; 'DTRIPP@TRIPPGROUP.ORG' St. Lucie Count%,
Cc: Joe Cicio
Subject: Plan Review Comments for Permit Number 1507-0355
Attachments: Report_FL_Review_Comments_Noncompliantjrf.pdf
Dear St. Lucie County Permit Applicant,
Please see the attached plan review comments which have been generated for your permit. As soon as we receive the
modified plans and any additional required documentation back from the design professional, contractor or owner we
will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have
been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to
permitting for permit issuance.
Thank You
lf"CA4 did. &&
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
St Luai,2 Cry Pta4u% ," aat4 DevOopmevt,l-Se rvi,r
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
S
Joe Cicio
From: Joe Cicio SCANNED
Sent: Wednesday, June 01, 2016 1:27 PM �Y
To: 'DTRIPP@TRIPPGROUP.ORG' CUCI@
Cc: Joe Cicio;'Russ@riocitrus.com' County
Subject: Comments to Revision dated 05/20/2016
Attachments: Repo rt_FL Review_Comments_Noncompliantjrf.pdf
Dear St. Lucie County Permit Applicant,
Please see the attached plan review comments which have been generated for your permit. As soon as we receive the
modified plans and any additional required documentation back from the design professional, contractor or owner we
will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have
been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to
permitting for permit issuance.
Thank you,
%ode," Wt. &&
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
StLv4;,e�Cuu y pl.avuiZ" ar',dDeveLorw�ewl ServicQ,S
.•. • • ♦ • ♦ • ♦♦
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
XbI ?0
�2 &