Loading...
HomeMy WebLinkAboutMISC EMAILi/ 14 Eli • DRITENBAS - BINKIEY ARCHITECTS AND ASSOCIATES, P.A. 65 Royal Palm Pointe, Ste D Vero Beach, FL 32960 Ph: (772) 569-4320 Fax (772) 569-9208 August 19, 2015 To: Planning and Development Services Building & Code Regulation Division 2300 Virginia Ave Fort Pierce, FL 34982 Attn: Joe Cicio Re: Rio Citrus, Inc. Permit#1507-0355 Metal Building (1 Story) Response to 8/13/2015 Comments Dear Mr. Cicio, SCANNED By SL Lucie County 'I ' y � n g65O 0�7 P/mz Please find our responses following your stated comments, along with the requested 3 sets of plans and 2 CD's with PDF files with all information, 1) SUBMIT ORIGINAL SIGNED, SEALED AND DATED ENGINEERED PLANS IN TRIPLICATE FOR THE PREENGINEERED ALUMINUM ACCESSIBLE RAMP * THESE PLANS MUST BE STAMPED REVIEWED AND APPROVED BY DESIGN PROFESSIONAL OF RECORD *** SECOND REVIEW / NOT SUBMITTED *** FEE DUE Response: EDB Architects will review the shop drawings submitted in triplicate from the General Contractor and if they are all ok we will mark them with a stamp stating "No Exceptions Taken". The GC will subsequently provide copies to the Building Department. 2) SUBMIT ORIGINAL, SIGNED, SEALED AND DATED METAL BUILDINGPLANS FROM THE MANUFACTURER STAMPED APPROVED AND READY FOR CONSTRUCTION FOR REVIEW * THESE PLANS MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD *** SECOND REVIEW / M.B.PLANS MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD BEING EDB ARCHITECTS *** FEE DUE Response: Upon receipt of shop drawings from the General Contractor, EDB Architects will have their structural engineering consultant, TRC Worldwide, review and stamp the copies with their own "Reviewed" and approved information. The General Contractor will subsequently provide copies to the Building Department. REC,i -:'I %UG 21'of 3) "PRODUCT REVIEW AFFIDAVITS" ARE INCORRECT OR INCOMPLETE * PRODUCT PRESSURES ARE INCORRECT * MODEL NUMBER IS NOT PART OF THIS N.O.A. , PRODUCT APPROVAL NUMBER IS INCORRECT * METHOD OF ATTACHMENT MUST BE FILLED IN AND REQUIRES WELDING *** THE LINE FOR THE SWING DOOR IS INCOMPLETE *** SUBMITTED TEST IS APPLICABLE TO THE 2001 FBC ??? *** SECOND REVIEW *** FEE DUE *** DID NOT RECEIVE REVISED, SEALED PRODUCT AFFIDAVITS * ALL PRODUCT APPROVALS MUST BE SELECTED FROM THE 2014 PRODUCT APPROVAL LIST AND INFORMATION AFFIXED TO THE AFFIDAVIT W/ PRODUCT APPROVALS ATTACHED * SUBMIT ALL IN TRIPLICATE Response: This data must be provided by the General Contractor. EDB Architects will assist him wherever we can, however, all product NOA's must come from the manufacturer selected by the General Contractor during his pricing out the project. 4) WIND LOAD SHEETS ARE INCOMPLETE* FILL IN EXPOSURE CATEGORY FBC 1609.4 *GARAGE DOOR LOAD TABLE 16.9.7 * LOADS ON GUARDRAILS FBC 1607.8 *** SECOND REVIEW *** FEE DUE *** NEED SIGNED, SEALED AND DATED " CERTIFICATION FOR DESIGN LOAD COMPLIANCE " SHEETS IN TRIPLICATE * THESE MUST BE COMPLETELY FILLED OUT, ORIGINALAND CANNOT BE ALTERED OR ADDED TO Response: See attached "Certification for Design Load Compliance", with Risk Category at I, Exposure B per FBC 1609.4, garage doors 30'x10' per 1609.7(1) with roof angle 0-10 degrees and 160 mph equates to +21.5, -24.2 psf. A PDF copy of the soils report is also included on CD. 5) MODIFY PLAN NOTES ON A-4 *** WE DO NOT ENFORCE IBC CODES * FBC 2010 AND CODE SITES ARE NOT CORRECT * PLEASE CITE ALL CODES FROM THE 2014 FBC 5TH EDITION ** DESIGN PROFESSIONAL TO ADDRESS FBC 2603.3 / EXCEPTION #2 * THIS MATERIAL IS BEING APPLIED AT 6" WHICH FALLS INTO THAT EXCEPTION FOR COLD STORAGE BUILDINGS *** THE INCORRECT CODE IS STILL BEING CITED ON PLAN SHEET A-4 *** SECOND REVIEW * FEES DUE *** Response: Sheet A-4 has been revised for compliance with FBC 2014 5t" Edition Code. The following explains our approach for using Icynene Insulation. a. FBC 2014 5" Edition (2603.3): Icynene pro -seal MD-C-200V3 spray foam insulation meets the requirements for flame spread index of not more than 75 (actual is <20 per ASTM 84) and a smoke development index of not more than 450 (actual <400 per ASTM E84). b. FBC 2014 SL" Edition (2603.3 Exception #2): Maximum thickness tested per ASTM E84 was 4" therefor, the thickness specified on the drawings Sheet A-4 has been reduced to 4" in lieu of 6". The 4" of Icynene MD-C-200V3 has an R-value of 27.0. The energy code was calculated using R-22.9, therefor we are ok with the reduction in insulation thickness. (A PDF copy of Energy Code is attached and included on the CD.) c. FBC 2014 5`" Edition (2603.4): The spray foam is being separated from the interior of the building by an equivalent thermal barrier using DC315, a spray applied intumescent coating as manufactured by International Fire Proof Technology, Inc. This product has been tested to meet UL1715 and NFPA 286 requirements as stipulated in 2603.4 and 2603.10 (Literature attached includes DC315 data, and evaluation report ESR-3500 for the Icynene Insulation.) 6) PLEASE RE -SUBMIT ALL REQUIRED PLANS AND ASSOCIATED DOCUMENTS IN TRIPLICATE AND ORIGINAL FORMAT FOR REVIEW * INCLUDE [ 21 PDF DISCS WITH ALL INFORMATION * WILL SUGGEST A MEETING WITH ALL PROFESSIONALS TO REVIEW THE COMMENT LIST IF NECESSARY Response: Attached please find all revised plans (and original void sheets) in triplicate as requested. Also included are (2) two CD's with PDF's of plans and associated data for review. I don't believe a meeting will be required but I am available for a telephone conversation, should you need additional clarification. If you have ions or need additional information, please contact us. sp fully s it d, Paul U. Dritenbas, AIA, NCARB, LEED AP Architect C:\Mary\040515VB\BldgDeptResponses.docx r- Joe Cicio From: Joe Cido Sent: Monday, August 17, 2015 8:51 AM To: 'DTRIPP@TRIPPGROUP.ORG'; Joe Cicio Cc: 'Russ@riocitrus.com' Subject: Second Review Comments for permit number 0355 m Attachments: Repo rt_FL_Review_Comments_NoncoIT2rk7 40 St. Lucie County Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. � Thank You, Plans� &11 61 Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner Sf Lvzio& Covm_fy PL&*voi" a*L& DeAret&pwl.R,�Sei vLtzp Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Joe Cicio From: Joe Cicio Sent: Monday, August 03, 2015 8:56 AM To: 'DTRIPP@TRIPPGROUP.ORG' Cc: Joe Cicio Subject: Review Comments for Permit Number 1507-0355 SCANNED Attachments: Repo rt_FL_Review_Comments_Noncompliantjrf.pdf BY St. Lucie County Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank You, Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner St L-v4, - Covwwhy PL&vwA " a.K& D�Servi cey Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Joe Cicio From: Joe Cicio SCANNED Sent: Monday, August 31, 2015 3:20 PM BY To: 'Russ@ riocitrus.com'; 'DTRIPP@TRIPPGROUP.ORG' St. Lucie Count%, Cc: Joe Cicio Subject: Plan Review Comments for Permit Number 1507-0355 Attachments: Report_FL_Review_Comments_Noncompliantjrf.pdf Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank You lf"CA4 did. && Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner St Luai,2 Cry Pta4u% ," aat4 DevOopmevt,l-Se rvi,r Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. S Joe Cicio From: Joe Cicio SCANNED Sent: Wednesday, June 01, 2016 1:27 PM �Y To: 'DTRIPP@TRIPPGROUP.ORG' CUCI@ Cc: Joe Cicio;'Russ@riocitrus.com' County Subject: Comments to Revision dated 05/20/2016 Attachments: Repo rt_FL Review_Comments_Noncompliantjrf.pdf Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank you, %ode," Wt. && Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner StLv4;,e�Cuu y pl.avuiZ" ar',dDeveLorw�ewl ServicQ,S .•. • • ♦ • ♦ • ♦♦ Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. XbI ?0 �2 &