Loading...
HomeMy WebLinkAboutMISC LETTERPAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com SCANNED BY St. Luce Count. July 31, 2015 Re: Yanikoski Shutter Installation 9650 S. Ocean Dr. (#2005) Jensen Beach, FL 34957 To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2014 for the installation of accordion shutters at the above referenced address. Wind speed: Vwt: 165 mph, Vd: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Shutter Location: Covered Porch (See Attached Sketch) Required Design Pressure: +29.3 / -39.2 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Productal and Florida Building Code 2014. Accordion Shutters shall be FL# 389.1. Thank you for your attention to this matter. f Submitted by: PAUL LCH INC. Paul We P.E. Reg. No 29945