TECHNICAL INFORMATION SHEET BUILDING PRODUCTS
APP 160
Item Description
1 Roll (1 square)
orexceeds
SCANNED
BY
St. Lucie Countv
Item Number/
W70APP0162
Grade
Glass Yam Sand
Reinforced Surfacing
Polyester Mat
Bum -off
APP
Modified
Bitumen
Description:
Firestone APP 160 is a smooth -surface APP modified bitumen membrane designed to be heat -welded. It consists of
select asphalt, modified with atactic polypropylene, and strengthened with a fiber glass reinforced nonwoven polyester
mat [1 go g/m' (3.9 Ib/100 ft2)] made with 100% recycled PET fibers. The combination results in a flexible and durable
material that exceeds the performance requirements of ASTM D 6222 Type I, Grade S. APP 160 is strong and stable,
and resistant to natural forces and other factors on the rooftop. It is ideal for both new construction and re -roofing
applications as a base ply, cap sheet, or as a flashing sheet in single or multi -ply APP applications.
Moll Width: T 3" (1 m) Pallet Size: 48" x 39" (1.2 m x 1 m)
Roll Length: 32' 10" (10 m) Rolls Per Pallet: 20
Net Coverage: 98 ft' (9.1 m2) Weight per Pallet: 2.050 lb (932 kg)
Roll Weight 100 lb (45 ka)
Method of Application:
1. APP 160 must be installed by fully heat welding the membrane to an appropriate substrate.
2. Please seethe APP Design and Application Guide at www.firestonebpco.com for detailed application information.
Acceptable Immediate Substrates for Heat -Welded Application:
• Structural. Concrete (must be clean, dry, properly cured, and primed with ASTM D-41 primer).
• Approved Firestone base sheet.
• Existing Smooth Surface BUR or APP Modred Bitumen (must be clean, smooth and primed with ASTM D-41 primer).
• DensDeck® Prime, SECUROCKO Gypsum Fiber.
-- -NOTE: Please consult the APP Design Guide and QuickSpecs online at www.firestonebpco.com to review specific
information regarding the type of deck and insulation in use.
Storage:
• All material should be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of
50 OF (10 °C) and a maximum of 100 OF (38 °C) so that it will be 50 OF (10 °C) or above at the time of application.
• Do not stack Firestone APP 160 membrane more than two (2) pallets high.
• If the material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a
pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner that does
not exceed the allowable load limit of the storage area.
Firestone Building Products I Sales: (800) 428.44421 Technical (800) 428-4511 1 w .firestonebpco.com
TIS # 401
Page 1 of 2
2120/2015
'Firestone
TECHNICAL INFORMATION SHEET BUILDING PRODUCTS
h
Precautions:
• For safety information, refer to the Safety Data Sheet (SDS) for APP Membranes and Flashing.
• Take care when transporting and handling Firestone Modified Bitumen rolls to avoid punctures and other types of
physical damage.
• Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone
Modified Bitumen membranes.
LEEDS Information: �pssff��
Post Consumer Recycled Content: 8% MuuaropoEcoUPM G
Post Industrial Recycled Content: 0% FM C U` US
Manufacturing Location: Beech Grove, IN APPNOV®
'NOTE: LEER® is a registered trademark of the U.S. Green Building Council.
Typical••-
(Meets ASTM D 6222, TXpe 1, Grade
Pro a
S. Tested in accordance with
ASTM Standard Required Value
D 5147.)
Firestone Tvalcal Performance
Product Thickness:
140 mil (3.5 mm)
164 mil (4.2 mm)
Net Mass:
70 Ib/100 ft' (3,418 g/m2)
102 Ib/100 ft' (4,980 g/m�
Bottom Side Coating:
30 mil (0.76 mm)
47 mil (1.20 mm)
Peak Load at 73 °F (23 °C):
50lbf/in, MD (8.8 kN/m, MD)
55 Ibf/in, MD (9.6 kNlm, MD)
50 Ibf/in, XMD (8.8 kN/m, XMD)
55lbilm, XMD (9.6 kN/m, XMD)
Elongation at Peak Load at 73 °F (23 °C):
23%, MD
30%, MD
23%,XMD
30%,XMD
Peak Load at 0 °F (-18 °C):
60 Ibf/in, MD (10.5 kN/m, MD)
65 Ibfln, MD (11.4 kN/m, MD)
60 Ibf/in, XMD (10.5 kN/m, XMD)
651bf/in, XMD (11.4 kN/m, XMD)
Elongation at Peak Load at 0'F (A8 °C):
10%, MD
15%, MD
10%, XMD
15%, XMD
Ultimate Elongation at 5% of Peak Load
73 'F (23 °C):
30%, MD
40%, MD
30%, XMD
40%, XMD
Tear Strength at 73 'F (23 °C):
70 IV, MD (311 N, MD)
75 Ibf, MD (334 N, MD)
70 Ibf, XMD (311 N, XMD)
75 Ibf, XMD (334 N, XMD)
Low Temperature Flexibility:
32 °F (0 °C)
32 -F (0 °C)
Dimensional Stability:
1 % Change, MD
0.2% Change, MD
1 % Change, XMD
0.2% Change, XMD
Compound Stability:
230 °F (110 °C)
270 °F (132 °C)
Water Absorption:
3.2%
0%
Moisture Content:
1%
0%
Low Temperature Unrolling:
41 -F (5 -C)
0 °F (-18 °C)
Please contact Quality Building Services Technical Department at 1-8004284511 for further information.
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for
furnishing quality materials which meet published Firestone product specifications or other technical documents, subject to normal roof manufacturing
tolerances. Neither Firestone nor its representatives practice architecture. Firestone otters no opinion on and expressly disclaims any responsibility for
the soundness of any structure. Firestone accepts no liability forstmcturel failure or resultant damages Consult a competent structural engineer prior to
installation if the structural soundness or structural ability to property support a planned installation is in question. No Firestone representative is
authorized to vary this disclaimer.
Firestone Building Products I Sales: (800) 428.4"21 Technical (800) 428.4511 1 www.firestonebpco.com
TIS#401 FILE
C40py
Page 2 of 2
TECHNICAL INFORMATION SHEET
F.I%ra
Item Description
1 Roll — UltraWhiteTm (1 Square)
1 Roll —White (1 Square)
1 Roll —Black (1 Square)
exceeds
Description:
Item Number
W70PUWP1800
W70PWP1800
W70PBP1800
of ASTM D 6222. TVDe 1. Grade G.
Firestone
BUILDING PRODUCTS
Glass Yam Granule
Reinforced Surface
Polvester Mat
Modified
Bitumen
Firestone APP 180 is a granule -surface APP modified bitumen roofing membrane designed to be heat welded. It consists
of select asphalt, modified with atactic polypropylene, and strengthened with a fiber glass reinforced polyester nonwoven
mat [190 g/m2 (3.9 I6/100 f12)] made with 100% recycled PET fibers. The combination results in a flexible and durable
material that exceeds the performance requirements of ASTM D 6222 Type I, Grade G. APP 180 is a membrane that is
strong and stable, and resistant to natural forces and other factors on the rooftop. It is ideal for both new construction and
re -roofing applications as a cap sheet or as a flashing sheet in single or multi -ply APP applications.
Roll Width: 3' 3" (1 m) Pallet Size: 48" x 39" (1.2 m x 1 m)
Roll Length: 32' 10" (10 m) Rolls Per Pallet: 20
Net Coverage: 98 ft2 (9.1 m2) Weight per Pallet 2,030 lb (923 kg)
Roll Weight 99 lb (45 kg)
Method of Application:
1. APP 180 must be installed by fully heat welding the membrane to an appropriate substrate.
2. Please seethe APP Design and Application Guide at www.firestonebpco.com for detailed application information.
Acceptable Immediate Substrates for Heat -Welded Application:
• Structural Concrete (must be clean, dry, properly cured, and primed with ASTM D-41 primer).
• Approved Firestone base sheet.
• Existing Smooth Surface BUR or APP Modified Bitumen (must be clean, smooth and primed with ASTM D-41 primer).
• DensDece Prime, SECUROCe Gypsum Fiber.
NOTE: Please consult the APP Design Guide and QuickSpecs online at www.firestonebpeo.com to review specific ,
information regarding the type of deck and insulation in use.
Storage:
• All material should be stored out of the weather in a clean, dry area in its original unopened packaging at a minimum of
50 OF (10 "C) and a maximum of 100 OF (38 "C) so that it will be 50 OF (10 "C) or above at the time of application.
• Do not stack Firestone APP 180 membrane more than two (2) pallets high.
• If the material must be stored temporarily on the roof before application, it must be elevated from the roof surface on a
pallet, stored on end, and covered from the weather with a light colored opaque tarp in a neat, safe manner that does
not exceed the allowable load limit of the storage area.
Firestone Building Products I Sales: (800) 4284442 1 Technical (800) 428.4511 1
TIS # 406
Page 1 of 3
419/2015
TECHNICAL INFORMATION SHEET Firestone
BUILDING PRODUCTS
,..
Precautions:
• For safety information, refer to the Safety Data Sheet (SDS) for APP Membranes and Flashing.
• Take care when transporting and handling Firestone Modred Bitumen rolls to avoid punctures and other types of
physical damage.
• Isolate waste products, petroleum products, grease, oil (mineral and vegetable) and animal fats from all Firestone
Modified Bitumen membranes.
LEED® Information:
Post Consumer Recycled Content: 6% t�IIJI
Post Industrial Recycled Content: 0% FI1B MIAMM=ECOUPM
Manufacturing Location: Beech Grove, IN APPRQ1i® ' ' e�i,
`NOTE: LEED is a registered trademark of the U.S. Green Building Council.
TypicalProperties
(Meets ASTM D 6222, Type 1, Grade
Pro a
G. Tested in accordance with
ASTM Standard Reauired Value
D 5147.)
Firestone Typical Performance
Product Thickness:
160 mil (4 mm)
165 mil (4.2 mm)
Net Mass:
85 Ib/100 ft- (4,150 g/m-)
95lb/100 ft- (4,639 g/ml
Bottom Side Coating:
30 mil (0.76 mm)
43 mil (1.10 mm)
Peak Load at 73 OF (23 °C):
50 Ibffin, MD (8.8 kN/m, MD)
55 Ibffin, MD (9.6 kWm, MD)
50 lbfln, XMD (8.8 kN/m, XMD)
55lbffin, XMD (9.6 kN/m, XMD)
Elongation at Peak Load at 73 OF (23 °C):
23%, MD
30%, MD
23%, XMD
30%, XMD
Peak Load at 0 °F (-18 °C):
60 Ibffn, MD (10.5 kN/m, MD)
65 Ibffin, MD (11.4 kN/m, MD)
60 Ibf/in, XMD (10.5 kN/m, XMD)
65 Ibffin, XMD (11.4 kN/m, XMD)
Elongation at Peak Load at 0 OF (-18 °C):
10%, MD
15°/a, MD
10%, XMD
15%, XMD
Ultimate Elongation at 5% of Peak Load
73 OF (23 °C):
30%, MD
40%, MD
30%, XMD
40%, XMD
Tear Strength at 73 OF (23 °C):
70 Ibf, MD (311 N, MD)
75 Ibf, MD (334 N, MD)
70 IV, XMD (311 N, XMD)
75 IV, XMD (334 N, XMD)
Low Temperature Flexibility:
32 OF (0 °C)
32 OF (0 °C)
Dimensional Stability:
1% Change, MD
0.2% Change, MD
1% Change, XMD
0.2% Change, XMD
Compound Stability:
230 OF (110 °C)
270 OF (132 °C)
Granule Embedment, max loss:
2 g
0.5 g
Water Absorpt on:
3.2%
0%
Moisture Content:
1%
0%
Low Temperature Unrolling:
41 OF (5 °C)
0 OF (-18 °C)
a
Firestone Building Products I Sales: (800) 428-44421 Technical (800) 428-4511 I www.firestonebpco.com
TIS # 406
Page 2 of 3
4/912015
Virestone
TECHNICAL INFORMATION SHEET BUILDING PRODUUM—
Radiative
Properties
Cool Roof Rating Council tCRRC1: UltraWhite Sheet: Initial / 3 yr
Solar Reflectance 0.711 Pending
Thermal Emittance 0.87 / Pending
Rated ProductID 0034
Licensed Manufacturer ID 0608
Classification Production Line
Solar Reflectance Index (SRI)* 87
SRI calculated using the ORNL (DOE) calculator, ASTM E 1980-01
NOTE: The initial SRI for standard white membrane is 32. The SRI for black membrane is N/A.
co, 'Firestone
CR�
MBER M FIN
Please contact Quality Building Services Technical Department at 1-800-4284511 for further information.
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for
fumishing quality materials which meet published Firestone pmduct specifications or other technical documents, subject to normal roof manufacturing
tolerances. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for
the soundness of any structure. Firestone accepts no liability for stmcturel failure orresultant damages. Consult a competent structural engineer priorto
installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is
authorized to vary this disclaimer.
Firestone Building Products I Sales: (800) 428.44421 Technical (800) 428-4511 1 www.flmstonebpco.com
f
TIS # 406
Page 3 of 3
4/9/2015
NOTE: The initial SRI for standard white membrane is 32. The SRI for black membrane is N/A.
co, 'Firestone
CR�
MBER M FIN
Please contact Quality Building Services Technical Department at 1-800-4284511 for further information.
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for
fumishing quality materials which meet published Firestone pmduct specifications or other technical documents, subject to normal roof manufacturing
tolerances. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for
the soundness of any structure. Firestone accepts no liability for stmcturel failure orresultant damages. Consult a competent structural engineer priorto
installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is
authorized to vary this disclaimer.
Firestone Building Products I Sales: (800) 428.44421 Technical (800) 428-4511 1 www.flmstonebpco.com
f
TIS # 406
Page 3 of 3
4/9/2015