Loading...
HomeMy WebLinkAboutNOAsr. LucIE COUNTY SCANNED BUILDING DIVISION BY REVIEWED FOR COMPLI E St. Lucie County �Y WED BY ' .2. L MIAMI•DADE PLANS AND PER IT MIAMI-DADE COUNTY E UST BE KEPTON JOBOR PRODUCT CONTROL SECTION INSPECTION WILL BE MADE 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMI R) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.-govIeconomv Johns Manville Corporation 717 17th Street Denver, CO SCOPE: 80202 FILE This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DE�CRIP ION.','Johns 1VIiinville Modified Blfuinen RoofingSystemsoveY Conci•efeD'ecks: r, LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been Sled and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-0129.20 and consists of pages 1 through 44. The submitted documentation was reviewed by Jorge L. Acebo. THESE PLANS AND ALL PRPOWD WORK NOA No.: 13-0529.19 MIA MADE COUNTY ARE SUBJECT TO Y ECTIONS Expiration Date: 07/19/16 F.M.REQUIRED BY PIELD i1i3RS THAT Approval Date: 03/06/14 MAY BE NEC At N ORM TO Page I of 44 COMPLY WITH ALL ICABLE CODES. ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: Modified Bitumen Materials: SBS Deck Type: Concrete Maximum Design Pressure: -536.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description DynaBase 39-3/8" x 49'2" ASTM D6163 A glass..reinforced SBS modified bitumen Type I Grade S base sheet. DynaBase PR 39-3/8" x 49'2" ASTM D6164 A polyester reinforced SBS modified Type I Grade S bitumen base sheet. DynaWeld Base 39-3/8" x 32' 10" ASTM D6163 A glass reinforced SBS modified bitumen Type I Grade S base sheet for heat welded applications. DynaBase HW 39-3/8" x 49'2" ASTM D6163, A glass reinforced SBS modified bitumen Type I Grade S base sheet for heat welded applications. DynaWeld 180 S 39-3/8" x 32' 10" ASTM D6164 A polyester reinforced SBS modified Type I Grade S bitumen base or inner ply sheet for use in heat weld applications. DynaWeld Cap FR 39-3/8" x 32' 10" ASTM D6163 A fire resistant, polyester reinforced SBS CR Type I Grade G modified bitumen membrane surfaced with granules and a white reflective coating for use in heat weld applications. DynaGlas FR CR 39-3/8" x 32' 10' ; ASTM D6163 A fire resistant, glass reinforced SBS Type I Grade G modified bitumen membrane surfaced with granules and a white reflective coating. DynaGlas 39-3/8" x 32' 10" ASTM D6163 A glass reinforced SBS modified bitumen Type I Grade G membrane surfaced with granules. DynaWeld Cap FR 39-3/8" x 32' 10" ASTM D6163 A fire resistant, glass reinforced SBS Type I Grade G modified bitumen membrane surfaced with granules for use in heat weld applications. DynaWeld Cap 180 39-3/8" x 32' 10" ASTM D6164 A fire resistant, polyester reinforced SBS FR Type I Grade G modified bitumen membrane surfaced with granules -for use in heat weld applications. Dyn ,as --180' 39-3/8" x 49'2" ASTM D6164 A polyester reinforced SBS modified bitumen base or inner ply sheet. DynaFast 180 HW 39-3/8" x 49'2" ASTM D6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. DynaFast 250 HW 39-3/8" x 32' 10" ASTM D6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. DynaWeld Cap 250 39-3/8" x 32' 10" ASTM D6164 A fire resistant, polyester reinforced SBS FR Type II Grade G modified bitumen membrane surfaced with granules for use in heat weld applications. NOA No.: 13-0529.19 Expiration Date: 07/19/16 Approval Date: 03/06/14 Page 2 of 44 Product DynaWeld Cap 250 FR CR DynaWeld Cap 250 DynaWeld 250 S DynaGlas 30 FR DynaGlas FR DynaKap TI DynaKap FR TI DynaLastic 180 DynaLastic 180 FR DynaLastic 180 S DynaWeld 180 S DynaPly Tl DynaLastic 250 FR DynaLastic 250 FR -CR - - Dimensions 39-3/8" x 32' 10" Test Specification Product Description ASTM D6164 A fire resistant, polyester reinforced SBS Type II Grade G modified bitumen membrane surfaced with 39-3/8" x 32' 10" ASTM D 6164 Type II Grade G 39-3/8" x 32' 10" ASTM D 6164 Type II Grade S 39-3/8" x 32'10" 39-3/8" x 32' 10" 39-3/8" x 32' 10" 39-3/8" x 32' 10" 39-3/8" x 32' 10" 39-3/8" x 32' 10" ASTM D6163 Type I Grade G ASTM D6163 Type I Grade G ASTM D6162 Type I Grade G ASTM D6162 Type I Grade G ASTM D6164 Type I Grade G ASTM D6164 Type I Grade G 39-3/8" x 32' 10" ASTM D6164 Type I Grade S 39-3/8" x 32' 10" ASTM D6162 Type I Grade S 39-3/8" x 32' 10" ASTM D6162 39-3/8" x 32' 10". Type I Grade S ASTM D6164 Type II Grade G 39-3/8" x 32' 10" ASTM D6164 Type II Grade G DynaLastic 250 S 39-3/8" x 32' 10" ASTM D6164 Type II Grade S DynaMax FR 39-3/8" x 32' 10" ASTM D6162 Type III Grade G DynaMax S 39-3/8" x 32' 10" ASTM D6162 Type III Grade S MIAMI•DADE COUNTY ,...8 1 granules and a reflective white coating for use in heat weld applications. A polyester reinforced SBS modified bitumen membrane surfaced with granules for use in heat weld applications. A polyester reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules. A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules. A composite reinforced SBS modified bitumen membrane surfaced with granules. A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with granules. A polyester reinforced SBS modified bitumen membrane surfaced with granules. A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules. A polyester reinforced SBS modified bitumen base or inner ply sheet. A composite reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. A composite reinforced SBS modified bitumen base or inner ply sheet. A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules. A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules and a reflective white coating. A polyester reinforced SBS modified bitumen base or inner ply sheet. A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with granules. A composite reinforced SBS modified bitumen base or inner ply sheet. NOA No.: 13-0529.19 Expiration Date: 07/19/16 Approval Date: 03/06/14 Page 3 of 44 Test Product Product Dimensions Specification Description DynaClad 39-3/8" x 33' 10" ASTM D6298 A glass reinforced base sheet SBS modified bitumen membrane surfaced with foil. DynaBase XT 39-3/8" x 49'2" ASTM D6163 A glass reinforced SBS modified bitumen Type I Grade S base or inner ply sheet. DynaGlas FR XT 39-3/8" x 32' 10" ASTM D6163 A fire resistant, glass reinforced SBS Type I Grade S modified bitumen membrane surfaced with granules. G1asKa' -' 36" x 36' ASTM D3909 A mineral surfaced, asphalt coated, fiberglass cap sheet. GlasKap CR 36" x 36' ASTM D3909 A white mineral surfaced, white acrylic coated, fiberglass cap sheet. Ventsulation Felt 36" x 36' ASTM D4897 Heavy duty fiber glass base sheet Type II impregnated and coated on both sides with asphalt with or without fine mineral stabilizer. Surfaced on the bottom side with coarse mineral granules embedded in asphaltic coating. GlasBase Plus 36" x 108' ASTM D4601 Type 1I asphalt impregnated and coated glass fiber base sheet for use in conventional and modified bitumen built- up roofing. GlasPly IV 36" x 200' ASTM D2178 Type IV asphalt impregnated glass felt for Type IV use in conventional and modified bitumen built-up roofing. GlasPly Premier 36" x 180' ASTM D2178 Type VI asphalt impregnated glass felt for Type VI use in conventional and modified bitumen built-up roofing. PermaPly 28 36" x 108' ASTM D4601 Type II asphalt impregnated and coated Type II glass fiber base sheet for use in conventional and modified bitumen built- up roofing. FesCant Plus Cant various ASTM C728 Factory pre -fabricated cant strips and taper Strips, and Taper edge, manufactured from expanded perlite Edge insulation. MBR Flashing N/A Proprietary A two component elastomeric, cold Cement Base and application adhesive, consisting of a Activator - - modified proprietary compound with an asphalt base. MBR Bonding N/A Proprietary A two component urethane cold Adhesive application adhesive. MBR Cold 5, 55, and 350 gal, ASTM D3019 One part, elastomeric cold application Application Adhesive Type III adhesive MBR Low VOC 5 gal Proprietary One part, asphalt modified urethane Membrane Adhesive adhesive MBR RA Membrane 1.5L Cartridge Proprietary Two part, cold process membrane adhesive Adhesive NOA No.: 13-0529.19 MIAMI-DADE COUNTY Expiration Date: 07/19/16 ""0 1 Approval Date: 03/06/14 Page 4 of 44 Test Product Product Dimensions Specification Description JM Urethane N/A Proprietary Urethane insulation adhesive. Insulation Adhesive JM Two Part N/A Proprietary A two-part urethane insulation adhesive Urethane Insulation Adhesive Bestile Industrial various ASTM D4586 A trowel grade, cutback bitumen flashing Roof Cement Type I grade cement mixture including inorganic fibers and mineral stabilizers. Flex -I -Drain various BOCA 76-61 Two piece flexible drain system composed SBCCI 89204 of a Noryl deck flange, a flexible neoprene UBC 3236 bellows and no hub connection. Available in various sizes and styles for most Retro- Fit Board applications. PC/PET RetroDrain various N/A Engineered resin copolymer fabricated drain for retrofit applications. USII RetroDrain various N/A One piece, aluminum fabricated drain for retrofit applications. Superpome various N/A Cast aluminum, heavy-duty drain for RetroDrain retrofit applications. FP-10 Vents 10" deck flange, N/A One-way roof vent, designed for use in base diameter of 4" various roof systems, for the release of and a height of 6" pressure created by gases or moisture vapor trapped within the roofing system. Expand-O-Guard various N/A Elastomeric expansion joint cover for vertical expansion and seismic joints. Manufactured from non -reinforced, form - supported elastomeric bellows with a bifurcated waterproof attachment to metal flanges. Expand-O-Flash various N/A Expansion joint covers manufactured from non -reinforced, form -supported elastomeric bellows with a bifurcated waterproof attachment to metal flanges. Presto-Lok Fascia various TAS 114 A multi -piece fascia and flashing system and Flashing System for built-up and modified bitumen roofing systems manufactured from aluminum or steel. DynaTred & _ various N/A Preformed, skid -resistant boards. DynaTred Plus Roof Walkway NOA No.: 13-0529.19 Expiration Date: 07/19/16 Approval Date: 03/06/14 Page 5 of 44 APPROVED INSULATIONS: Product Name ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI TABLE 2 Product Description Polyisocyanurate Insulation. ENRGY 3 AGF, ENRGY 3 AGF 25 Isocyanurate Insulation with glass PSI, ENRGY 3 CGF, ENRGY 3 reinforced facers CGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI Manufacturer (With Current NOA) Johns Manville Johns Manville ENRGY 3 FR Isocyanurate Insulation with inorganic Johns Manville coated glass reinforced facers; bottom face is premium coated for combustible decks. Fesco Foam, DuraFoam Polyisocyanurate Insulation with perlite Johns Manville facer Retro-Fit Board, DuraBoard High -density perlite roof insulation. Johns Manville Fesco Board Rigid perlite roof insulation board. Johns Manville JM SECUROCK Gypsum -Fiber Rigid, gypsum -based board stock Johns Manville Roof Board APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. All Purpose Fastener Insulation fastener for # 14 x 16" max. Johns Manville concrete decks. length; 43 Phillips head 2. Structural Concrete Insulation fastener for Various Johns Manville Fastener concrete decks. 3. UltraFast 3" Round Galvalume AZ55 3" round Johns Manville Metal Plate or UltraFast steel plate 3" square - Square Recessed Metal Plate 4. UltraFast Plastic Plate High Density 3" round Johns Manville Polyolefin round plate 5. UltraFast ASAP Pre -assembled Various Johns Manville Insulation fastener and plate 6. High Load Fasteners and # 15 fasteners and 20 2-3/8" round Johns Manville Plates gauge metal plates NOA No.: 13-0529.19 Expiration Date: 07/19/16 Approval Date: 03/06/14 Page 6 of 44 EVIDENCE SUBMITTED: Test Agency/Identifier Factory Mutual Research Corp. Dynatech Engineering, Inc. Underwriters Laboratories, Inc. Exterior Research & Design, LLC TrinityjERD Independent Roof Testing & Consultants of South Florida IRT-ARCON Inc. Name 3001482 3001629 OZ8A9.AM 3D4A4.AM 3000949 3007148 3006346 3001457 3009499 3011248 3014090 3012974 3020703 3037222 3026130 J037540 3012064 4360.03.95-1 4360.03.95-2 4361.5.95-1 R10167 04361-2.04.97-1 # 10390A-10.97-1 #10390A-12.97-1 #4251.08.96-1 10391.01.03 02843.02.05-10-R1 00257.03.05-1 02843.02.07 J7670.06.08 J6990.12.07-R1 J 17040.1 l .09-RI J 13700.05.10-1-R l J13700.05.10-2 IRT 99006 IRT 99007 IRT 99008 IRT 99016 IRT 99009 IRT 99010 02-026 02-011 Report FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4450 FM 4450 FM 4470 FM 4470 FM 4470 FM 4470 FM 4450 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 TAS 114 TAS 114 TAS 114 UL 790 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 ASTM D6162/D6163 ASTM D6164/D6298 TAS 114 ASTM D3909 ASTM D6162/D6164 ASTM D6164 ASTM D5147/D6163 ASTM D5147/D6164 Date 08/11/98 09/ 10/98 09/10/98 09/28/98 06/05/98 04/ 19/00 09/ 15/00 03/04/02 04/04/01 11/O1/02 09/05/02 06/03/02 07/30/04 10/02/09 04/26/09 10/20/10 06/25/02 03/95 03/95 05/95 05/27/ 13 04/28/97 10/97 12/97 O1/20/99 01/29/03 02/07/07 03/17/05 02/07/07 06/16/08 03/24/10 03/11/10 O1/25/11 05/11/10 TAS 114 01/20/99 TAS 114 01/20/99 TAS 114 01/20/99 TAS 114 01/20/99 TAS 114 02/10/99 TAS 114 02/10/99 TAS 114 07/26/02 TAS 114 02/06/02 NOA No.: 13-0529.19 Expiration Date: 07/19/16 Approval Date: 03/06/14 Page 7 of 44 EVIDENCE SUBMITTED: (CONTINUED) Test Agency/Identifier Name Report Date PRI Construction Materials JMC-066-02-01 ASTM D6163 06/04/12 Technologies, LLC JMC-065-02-01 ASTM D6163 05/29/12 JMC-070-02-01 ASTM D2178 Type IV 04/17/12 JMC-071-02-01 ASTM D2178 Type VI 04/17/12 JMC-072-02-01 ASTM D4601 Type II 06/14/12 JMC-074-02-01 ASTM D4897 Type II 04/17/12 JMC-075-02-04.2 ASTM D5147/D6164 Type II 12/27/13 JMC-078-02-01 ASTM D5147/D6298 07/17/12 JMC-081-02-01.02 TAS 117 B & C 06/11/12 JMC-091-02-01 ASTM D4601 Type 1 06/04/12 JMC-093-02-01 ASTM D4601 Type II 08/02/12 JMC-105-02-01 ASTM D5147/D6162 05/22/13 JMC-107-02-01 Rev 4 ASTM D903 11/04/13 ASTM D1876 ASTM D5147 TAS 117(B) TAS 117(A) TAS 114(C) JMC-171-02-01 ASTM D6163 01/10/14 JMC-171-02-02 ASTM D6163 01/10/14 JMC-171-02-10 ASTM D6162 01/10/14 JMC-171-02-03 ASTM D6164 01/10/14 Atlantic & Caribbean ACRC 06-009 TAS 114-D 06/28/06 Roofing Consultants, LLC NOA No.: 13-0529.19 MIAMI•DADE COUNTY Expiration Date: 07/19/16 "' y m Approval Date: 03/06/14 Page 8 of 44 APPROVED ASSEMBLIES Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(1): One or more layers of insulation adhered with approved asphalt or adhesive. All General and System limitations apply. One or more layers of the following insulations: Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI, ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI, ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI Minimum 1.5" thick Fesco Foam, DuraFoam Minimum 1.5" thick Top Insulation Layer (Optional) Fesco Board, DuraBoard Minimum %" thick Retro-Fit Board Minimum''/2" thick N/A N/A N/A N/A Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A N/A N/A Note: All insulation shall be adhered to the primed deck in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAs 117 for insulation attachment.' Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: (Optional) One ply of GlasPly Premier, GlasPly IV or PermaPly 28 Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Ply Sheet: One or more plies of GlasBase Plus, PermaPly 28, GlasPly Premier, GlasPly IV, DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase PR, DynaBase XT, DynaMax S or DynaPly T I adhered to the base sheet with approved mopping of asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply DynaWeld Base, DynaBase HW, DynaWeld 180 S, DynaFast 180 HW, DynaWeld 250. S or DynaFast 250 HW heat welded. MIAMI-DADE COUNTY ..0 NOA No.: 13-0529.19 Expiration Date: 07/19/16 Approval Date: 03/06/14 Page 9 of 44 Membrane: One ply of DynaGlas FR CR, DynaKap, DynaKap FR T 1, DynaMax FR, DynaGlas, DynaGlas FR, DynaGlas 30 FR, DynaGlas FR XT, DynaLastic 180, DynaLastic 180 FR, DynaLastic 180 S, DynaLastic 250 FR, DynaLastic 250 FR CR or DynaPly TI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply DynaWeld Cap FR CR, DynaWeld Cap FR, DynaWeld Cap 180 FR, DynaWeld Cap 250, DynaWeld Cap 250 FR or DynaWeld Cap 250 FR CR heat welded. (See application instructions for approved method of installation). Or (Only with a modified Base or Ply sheet) GlasKap or GlasKap CR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. Surfacing: (Optional) Install one of the following: 1. Flood coat and gravel/slag with an application rate of 60 lbs./sq. & 400 lbs./sq., respectively. Maximum Design Pressure: -305 psE (See General Limitation 99). NOA No.: 13-0529.19 MIAMI•DADE COUNTY Expiration Date: 07/19/16 Approval Date: 03/06/14 Page 10 of 44 IMN "oni, 7c.. I 40U�7T®Y , DEPARTMENT OFREGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Johns Manville Corporation 717 17th Street Denver, CO 80202 SCOPE: SCANNED BY St. Lucie County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes: If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. - ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 12-0203.04 and consists of pages 1 through 39. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI•DADE COUNTY THESE PLANS AND ALL I ARE SUBJECT TO ANY REQUIRED BY PIEL MI MAY BE AtEC W COMPLY INITHAL AP 15 THAT NOA No.: 13-0129.16 i TO Expiration Date: 07/19/16 Approval Date: 06/27/13 CODES. Page I of 39 ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: Modified Bitumen Materials: SBS Deck Type: Lightweight Concrete Maximum Design Pressure: -105 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description DynaBase 54'-10" x 36" ASTM D6163 An SBS modified bitumen coated, fiber Type I Grade S glass reinforced base sheet. DynaWeld Base 39'-3/8" x 32'-10" ASTM D6163 An SBS modified bitumen coated, Type I Grade S fiberglass reinforced base sheet for heat welded applications. DynaWeld 180 S 39-3/8" x 32'-10" ASTM D6164 An elastomeric modified bitumen coated, Base Type I Grade S nonwoven polyester mat and bi- directional glass scrim reinforced, base sheet for heat welded applications. DynaWeld Cap FR 39'-3/8" x 32'-10" ASTM D6163 A fire resistant, cool roof (CR), SBS CR roll. Type I Grade G modified bitumen membrane surfaced weight: 120 lbs. with granules for heat weld applications. DynaGlas FR CR 39-3/8" x 32'-10'; ASTM D6163"A `A fire"iesistant,` cool roof (CR), SBS roll Type I Grade G modified bitumen membrane surfaced weight: 101 lbs. with granules for application in hot asphalt. DynaGlas 39-3/8" x 32'-10" ASTM D6163 An SBS modified bitumen membrane Type I Grade G surfaced with granules for application in hot asphalt. DynaWeld Cap FR 39'-3/8" x 32'-10" ASTM D6163 A fire resistant SBS modified bitumen Type I Grade G membrane surfaced with granules for heat weld applications. DynaWeld Cap 180 39-3/8" x 32'-10" ASTM D6164 A fire resistant, polyester reinforced, SBS FR Type I Grade G modified bitumen sheet. DynaGlas 30 FR 39-3/8" x 32'-10" ASTM D6163 A fire resistant SBS modified bitumen Type I Grade G membrane surfaced with granules for —application in hot -asphalt. --- - DynaGlas FR 39-3/8" x 32'-10" ASTM D6163 A fire resistant SBS modified bitumen Type I Grade G, • membrane surfaced with granules for application in hot asphalt. DynaKap Tl 39-3/8" x 32'-10" ASTM D6162 A fiberglass/polyester reinforced SBS Type I Grade G modified bitumen membrane surfaced with granules for application in hot asphalt. DynaKap FR Tl 39-3/8" x 32'-10" ASTM D6162 A fire resistant, fiberglass/ polyester Type I Grade G reinforced SBS modified bitumen membrane surfaced with granules for application in hot asphalt. NOA No.: 13-0129.16 MIAMI•DADE COUNTY Expiration Date: 07/19/16 ""9 1 Approval Date: 06/27/13 Page 2 of 39 Test Product Product Dimensions Specification Description DynaLastic 180 39-3/8" x 32'-10" ASTM D6164 A polyester reinforced SBS modified Type I Grade G bitumen membrane surfaced with granules for application in hot asphalt. DynaLastic 180 FR 39-3/8" x 32'-10" ASTM D6164 A 180 gram polyester mat reinforced, Type I Grade S granular -surfaced, modified bitumen cap sheet for use in fire -rated systems. DynaLastic 180S 37" x 36'-9" ASTM D6164 A 180 gram polyester mat reinforced, Type I modified bitumen cap sheet for use in fire -rated systems. DynaPly Tl 39-3/8" x 32'-10" ASTM D6162 A polyester reinforced SBS modified Type II, Grade S bitumen ply sheet for use in conventional and modified bitumen built-up roof systems. DynaLastic 250 39-3/8" x 32'-10" ASTM D6164 A 250 gram polyester mat reinforced, Type II Grade G granular -surfaced, modified bitumen cap sheet. DynaLastic 250 FR 39-3/8" x 32'-10" ASTM D6164 A 250 gram polyester mat reinforced, Type II Grade G granular -surfaced, modified bitumen cap sheet for use in fire -rated systems. DynaMax FR 39-3/8" x 32'-10" ASTM D6162 A fire, resistant, fiberglass/ polyester Type III Grade G reinforced SBS modified bitumen membrane surfaced'with granules for application in hot asphalt. DynaClad 39-3/8" x 33'-6" ASTM D6298 A foil faced, glass reinforced, SBS modified membrane for application in hot asphalt. DynaBase XT 39-3/8" x 49'-2" ASTM D6163 A heavyweight glass reinforced SBS Type I Grade S Base/Ply sheet. DynaGlas FR XT 39-3/8" x 32'-10" ASTM D6163 A heavyweight glass reinforced granular Type I Grade S surfaced SBS Cap sheet. G1asKap 36" x 36' ASTM D3909 A mineral surfaced, asphalt coated, fiberglass cap sheet. G1asKap CR 36" x 36' ASTM D3909 A white mineral surfaced, white acrylic coated, fiberglass cap sheet. Ven_ tsulation Felt 36" x_ 36' ASTM D4897 Heavy duty fiber glass base sheet Type II impregnated and coated on both sides with -asphalt with -or -without- fine mineral— ---- --- stabilizer. Surfaced on the bottom side with coarse mineral granules embedded in asphaltic coating. GlasBase Plus 36" x 108' ASTM D4601 Type II asphalt impregnated and coated glass fiber base sheet for use in conventional and modified bitumen built- up roofing. GlasPly IV 36" x 180' ASTM D2178 Type IV asphalt impregnated glass felt Type IV for use in conventional and modified bitumen built-up roofing. NOA No.: 13-0129.16 Expiration Date: 07/19/16 Approval Date: 06/27/13 Page 3 of 39 jam.. V Test Product Product Dimensions Specification Description GlasPly Premier 36" x 180' ASTM D2178 Type VI asphalt impregnated glass felt Type VI for use in conventional and modified bitumen built-up roofing. PermaPly No. 28 36" x 106' ASTM D4601 Type fl asphalt impregnated and coated Type II glass fiber base sheet for use in conventional and modified bitumen built- up roofing. FesCant Plus Cant various ASTM C728 Factory pre -fabricated cant strips and Strips, and Taper taper edge, manufactured from expanded Edge perlite insulation. MBR Flashing N/A Proprietary A two component elastomeric, cold Cement Base and application adhesive, consisting of a Activator modified proprietary compound with an asphalt base. MBR Bonding N/A Proprietary A two component urethane cold Adhesive application adhesive. Bestile Industrial various ASTM D4586, A trowel grade, cutback bitumen flashing Roof Cement Type I grade cement mixture including inorganic fibers and mineral stabilizers. Flex -I -Drain various BOCA 76-61 Two piece flexible drain system SBCCI 89204 composed of a Noryl deck flange, a UBC 3236 flexible neoprene bellows and no hub connection. Available in various sizes and styles for most retro-fit applications. PC/PET RetroDrain various N/A Engineered resin copolymer fabricated drain for retrofit applications. USII RetroDrain various N/A One piece, aluminum fabricated drain for retrofit applications. Superpome various N/A Cast aluminum, heavy-duty drain for RetroDrain retrofit applications. FP-10 Vents 10" deck flange, base N/A One-way roof vent, designed for use in diameter of 4" and a various roof systems, for the release of height of 6" pressure created by gases or moisture --- vapor- trapped within the -roofing -system.-- Expand-O-Guard various N/A Elastomeric expansion joint cover for vertical expansion and seismic joints. Manufactured from non -reinforced, form - supported elastomeric bellows with a bifurcated waterproof attachment to metal flanges. Expand-O-Flash various N/A Expansion joint covers manufactured from non -reinforced, form -supported elastomeric bellows with a bifurcated waterproof attachment to metal flanges. NOA No.: 13-0129.16 MIAMI•DADE COUNTY Expiration Date: 07/19/16 rRy • . 1 Approval Date: 06/27/13 Page 4 of 39 Test Product Product Dimensions Specification Description Presto-Lok Fascia various TAS 114 A multi -piece fascia and flashing system and Flashing System for built-up and modified bitumen roofing systems manufactured from aluminum or steel. DynaTred & various N/A Preformed, skid -resistant boards. DynaTred Plus Roof Walkway APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) ENRGY 3 Polyisocyanurate Insulation. Johns Manville Fesco Foam, DuraFoam Polyisocyanurate Insulation with perlite Johns Manville facer Retro-Fit Board, DuraBoard High -density perlite roof insulation. Johns Manville Fesco Board Rigid perlite roof insulation board. Johns Manville APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) I. Twin Loc-Nail Base sheet fastener with 2.7" dia. Plate ES Products, Inc. integrated Plate. 2. AccuTrac Plate Galvalume AZ50 steel plate 3" square OMG, Inc. 3. Lightweight Concrete Galvanized double spreading 1.2" or 1.7" Johns Manville (LWC) CR Base Fastener leg fastener for securing base leg length; sheets to lightweight 2.7" dia. Plate insulating concrete. 4. U1traFast Fastener Insulation fastener for wood, various Johns Manville steel and concrete. 5. CR Base Sheet Fastener Galvanized double spreading 1.2" or 1.7" OMG,Inc. L7 Ieg-fastener -for- securing -base— leg -length; — — -- sheets to lightweight 2.7" dia. Plate insulating concrete. 6. Ultralok Base sheet fastener with 2.7" dia. Plate Johns Manville integral plate NOA No.: 13-0129.16 Expiration Date: 07/19/16 Approval Date: 06/27/13 Page 5 of 39 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Underwriters Laboratories, Inc. R10167 UL 790 05/27/13 Factory Mutual Research Corp. 3001482 FM 4470 08/11/98 3001629 FM 4470 09/10/98 OZ8A9.AM FM 4470 09/10/98 3D4A4.AM FM 4470 09/28/98 3009499 FM 4470 04/04/01 107A4.AM FM 4470 11/09/98 3007148 FM 4450 04/19/00 3006346 FM 4450 09/15/00 3001457 FM 4470 03/04/02 3012974 FM 4450 06/03/02 3014090 FM 4470 09/05/02 3011248 FM 4470 11/01/02 3026130 FM 4470 04/26/09 Exterior Research & Design, LLC #4361-2.04.97-1 TAS 114 04/28/97 #4361-2.04. -1 TAS 114 04/00/97 #10390A-10.97-1 TAS 114 10/00/97 #10390A-12.97-1 TAS 114 12/00/97 #4251.08.96-1 TAS 114 01/20/99 00257.03.05-1 ASTM D6162/D6163 03/17/05 ASTM D6164/D6298 TrinitylERD 02843.02.07 TAS 114 02/07/07 J7670.06.08 ASTM D3909 06/16/08 J6990.12.07-R1 ASTM D6162/D6164 03/24/10 J17040.11.09 ASTM D6164 11/16/09 J13700.05.10-1-R1 ASTM D5147/136163 01/25/11 J13700.05.10-2 ASTM D5147ID6164 05/11/10 10391.01.03 TAS 114 01/29/03 Independent Roof Testing & IRT99001 TAS 114 01/20/99 Consultants of South Florida IRT99002 TAS 114 01/20/99 IRT99003 TAS 114 01/20/99 IRT99005 TAS 114 01/20/99 —IRT99013-- TAS"1-14— 01/20/99 Atlantic & Caribbean Roof ACRC 03012 TAS 114 12/04/03 Consulting, LLC ACRC 03015 09/30/03 ACRC 07-014 04/18/07 IRT-ARCON Inc. 02-011 TAS 114 02/06/02 NOA No.: 13-0129.16 Expiration Date: 07/19/16 Approval Date: 06/27/13 Page 6 of 39 EVIDENCE SUBMITTED: (CONT.) Test Agency/Identifier Name PRI Construction Materials JMC-066-02-01 Technologies, LLC JMC-065-02-01 JMC-070-02-01 JMC-071-02-01 JMC-072-02-01 JMC-074-02-01 JMC-075-02-04 JMC-078-02-01 JMC-081-02-01.02 JMC-091-02-01 JMC-093-02-01 JMC-105-02-01 Report Date ASTM D6163 06/04/12 ASTM D6163 05/29/12 ASTM D2178 Type IV 04/17/12 ASTM D2178 Type VI 04/17/12 ASTM D4601 Type II 06/14/12 ASTM D4897 Type II 04/17/12 ASTM D5147/D6164 Type II 08/03/12 ASTM D5147/D6298 07/17/12 TAS 117 B & C 06/11/12 ASTM D4601 Type I 06/04/12 ASTM D4601 Type II 08/02/12 ASTM D5147/D6162 05/22/13 Type III, Grade G NOA No.: 13-0129.16 Expiration Date: 07/19/16 Approval Date: 06/27/13 Page 7 of 39 APPROVED ASSEMBLIES Membrane Type: SBS Deck Type 4I: Lightweight Concrete, Insulated Deck Description: Concrecel Cellular Lightweight Concrete System Type A(1): Anchor sheet mechanically fastened; one or more layers of insulation adhered with approved asphalt. Deck: 18-22 ga steel deck shall be secured 6" o.c. to structural supports spaced a maximum of 5 ft. on centers with 5/8" puddle welds. Followed by Concrecel Bonding agent applied to the deck at rate 1200 sq. ft./gal using a compressed air sprayer. Rigid insulation panels shall be placed in a minimum'/4" slurry -coat of insulating concrete and allowed to cure overnight. The following day the rigid insulation shall be covered with a minimum 2'/4" topcoat cast of Concrecel. After an additional cure time of 24 hours Concrecel Curing Compound was roller applied at a rate of 300 sq. ft./gal. All General and System limitations apply. Anchor Sheet:neTpLkCrlasPlz3Pr'_etp er PermaPly 28 or Ventsulation fastened to the deck as described below: Fastening: Fasten base sheet to deck with 7M LWC CR Base Fasteners or OMG CR Base Sheet Fasteners 1.7 at the 3" side lap 7" o.c. and 7" o.c. in two staggered rows in the center of the sheet Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftr ENRGY 3 Minimum 1" thick N/A N/A Fesco Foam, DuraFoam Minimum 1.5" thick N/A N/A Fesco Board Minimum %" thick N/A N/A 1�I nim `W12?�,' t M, Iwo N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe Any listed insulation as Base Layer, above except ENRGY 3 Tapered Fesco Board Minimum %11 thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. NOA No.: 13-0129.16 Expiration Date: 07/19/16 Approval Date: 06/27/13 Page 8 of 39 eet: ane - r more plies of GlasBase Plus, PermaPly No. 28, G1asPly Premier, G1asPly IV, ^ yna as c T8 S DynaBase, DynaBase XT or DynaPly Tl adhered to the base s icc wi approved mopping of asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply DynaWeld Base heat welded. [Membrane One l.�,of DynaGlas FR CF, DynaKap TI, DynaKap FR Tl, DynaMax FR, DynaGlas, DynaGlas FR, DynaGlas 30 FR, DynaGlas FR XT, DynaLastic 180, DynaLastic 180 FF, DynaLastic 180 S, DynaLastic 250, DynaLastic 250FR or DynaPly Tl adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply DynaWeld Cap FR CR or DynaWeld Cap FR heat welded. Or (Only with a modified Base or Ply sheet) as °ap or G1asKap CR Adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. Surfacing: (Optional) Install one of the following: 1. Flood coat and gravel/slag with an application rate of 60 lbs./sq. & 400 lbs./sq., respectively. Maximum Design Pressure: -82.5 psf.(See General Limitation #7) NOA No.: 13-0129.16 Expiration Date: 07/19/16 Approval Date: 06/27/13 Page 9 of 39 LIGHTWEIGHT INSULATING CONCRETE SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117; calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. 2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage attached with 5/8" puddle welds with weld washers at every flute with maximum deck spans of 5 ft. o.c. 3. For systems where specific lightweight insulating concrete is not referenced, the minimum design mix shall be a minimum of 300 psi. GENERAL LEMTATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 IV., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. Insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered-Architect,or_Registered: Roof .Consultant (When this limitation is_ specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13-0129.16 Expiration Date: 07/19/16 Approval Date: 06/27/13 Page 39 of 39