Loading...
HomeMy WebLinkAboutSCALE CALIBRATION CERTIFICATEo� ATLANTIC SUPPLN . 2. 12c QUALITY DRILLING SUPPLIES AND MATERIALS TESTING EQUIPMENT 3740 Prospect Ave. #4 Riviera Beach, FL 33404 SUPPLY, INC. Phone: 800-535-7384 Fax: 561-844-3099 Scale Calibration Certificate SCANNED BY St. Luce County Custorner ? %`,; Aecom - Stuart C1thA6 dt AddrdSS. a a ;• 8528 SW Kansas Ave, Stuart, FL 34997 Scale Mfr " ;, Ohaus Scale Model ;< CS200 Arnbleot%Temp:;` 77 OF Scale'Serial#0126071 . ram Calibration Date a ', 3 , , '! 2/9l16 Nezt.`Cali6ratton%DtSe t sY,..r `.;_ 8/9/16 Calibration Technician -,,, Brandon Stinson Calibration Weight Information =Wei"tit'C' 6 100g -1g Senal`Numtiere 20481 Grade S' _ , "a Wei'ht Calib-rationi:Date 4-8-15* :NIST=: 105-7 Class F x'r Certtfre-@W# 200566 All Above Weights Tested With Reference Standards Traceable to the National Institute of Standards & Technology Through NIST Test Number 822/272103-05. Troemner 200mg Weight: Serial #1000075168; Class F1, SS, Certificate #200567, Cal Date: 4-8-15 Reference Thermometer: C22/Thermistor, Temperature Range -58 OF to 302 OF, Divisions 0.1 OF Accuracy at +23°C/+73°F 0.1 % ±0.2°C/0.4°F , Serial #02110924, Cal. Date: 4-7-15 Scale Calibration Actual_Wei ht , Unit�ScaleReadm 1 r `, ,�°-Deviation" , 0.2 Gramt� " 0.2 0.0 10.0 Gram' 10.0 0.0 r = 30.0 Gram i 30.0 0.0 50.0 Gram 50.0 0.0 % 100.0 Gram y. 100.0 0.0 120.0 Gram ="-: 120.0 0.0 % 140.0 Gram a :; 140.0 0.0 % 160.0 Gram 160.0 } 0.0% 180.0 Gram t 180.0 0.0 200.0 Gram -,y : 200.07 0.0 This scale has been calibrated perASTM D-4753. ** % Deviation must be within +/- .1 % * Calibration weights are calibrated annually. IECIEDVE APR 1 3 REC'D This certificate shall not be considered or regarded as any type of guarantee or warranty of any form, in favor of the user, the user's customers, or the public at large, that this instrument will continue to retain the same percentage of accuracy as reported on this date, when the calibration, verification; and/or adjustment was performed by Atlantic Supply. Atlantic Supply has absolutely no control over the future operation, performance, damage, maintenance repairs, cleaning and overall condition of said instrument and hereby expressly disclaims any and all liability for damage or loss sustained by any and all parties arising from deterioration, obsolescence, malfunction or sub -standard performance of this instrument. Liability for maintaining this instrument in the same operating condition as d was found to be in on the date of this certificate is the sole responsibility of said instruments owner. This form may not be reproduced in any form whatsoever, except in whole, without the expressed written permission of Atlantic Supply Cal.Cert. Scale Calibration 4-14-15 R.B. Aecom 0126071 2-9-16.xis IN Qcyc SUPPLY, INC. ATLANTIC SUPPLY QUALITY DRILLING SUPPLIES AND MATERIALS TESTING EQUIPMENT 3740 Prospect Ave. #4 Riviera Beach, FL 33404 Phone: 800-535-7384 Fax: 561-844-3099 Speedy Moisture Meter Gauge Calibration Certificate gdi#i an Name1T& r x xK 3 Aecom - Stuart Coto -L Address >. 8528 SW Kansas Ave, Stuart, FL 34997 Cdlibra}ion Date's F"-. 2/9/16 IPrevi0dkC4F4Date Unknown Next;Gabbratlori Due t 819/16 SO eed ',Gau earandR&D/2 Gib 'e Sertal,Miimber�T 0126071 DfalZeioes7nAl1,P._osrtwns'y VesseGSena(Nurtitier s Yes 0126071 ScaleSena(Nurilber**" .c. 0126071 **** See separate certificate for scale calibration Gau"e`SealsTa,VesssetBod";;; Yes Alilbieot7em"'etature wi 77 OF Ca1.-StickerA"'lied? M Yes Brandon Stinson Calibrated 8 r' a, Speedy Vessel Gauge Verification CaIF =Test Po1n4-Reailiiag --Tester� �`Tester:F ,j Gauge 20.0 Delta #1+_ 0.0 Gauge a ,headings 20.0 Delta ,1#2';J2eadirg#3„ 0.0 Tester,FDOT` n Gauger , 20.0 Delta 0.0� -r , Allowable = Delta' _ 10.. 20.0% 19.0% 19.1 -0.1 19.1 -0.1 19.1 -0.1 18.0% 18.1 -0.1 18.1 -0.1 18.1 -0.1 a 4 5 17.0% 17.1 -0.1 17.1 0.1 17.1 -0.1 ;'; - 0 6 16.0% 16.1 -0.1 1 16.1 -0.1 16.1 -0.1 15.0%1 15.1 -0.1 1 15.1 -0.1 15.1 -0.1 r03, 14.0% 14.1 1.1 14.1 -0.1 14.1 -0.1 r't05,u,i.` 13.0% 13.1 -0.1 13.1 -0.1 13.1 -0.1 ';... W ys 12.0% 12.1 -0.1 12.1 -0.1 12.1 -0.1 il$ Viz_ 11.0% 11.1 -0.1 11.1 -0.1 11.1 -0.1 10.0% 10.1 -0.1 10.1 -0.1 10.1 -0.1 9.0% 9.1 -0.1 9.1 -0.1 9.1 -0.11 �05� 8.0% 8.1 -0.1 8.1 -0.1 8.1 -0.1 a 0 5 r 7.0% 7.1 -0.1 7.1 -0.1 7.1 -0.1 D 5 6.0% ___ 6.1 -0.1 _ _6.1 -0.1 6.1 -0.1 s= 5.0%1 5.1 -0.1 5.1 -0.1 5.1 -0.1 O s„ ---4.0% 4.1 -0.1 4.1 -0.1 4.1 -0.1 3.0% 3.0 0.0 3.0 0.0 3.0 2.0% 1.9 0.1 1.9 0.1 1.9 01 1.0% 0.8 0.2 0.8 0.2 0.8 0.210' 0.0% 0.0 0.0 0.0 0.0 0.0 0.0 l .iveragel w.� 1<µ nwveragel -u.� l �A�erdge� -0.1 i FDOT requires calibration every 6 months per FM 5-507, other jobsites are calibrated every 12 months. Calibration Equipment: Calibration Gauge: Ashworth Speedy Kit, Serial #13288424, Cal. Date 4-7-15 Reference Thermometer: C22rrhermistor, Temperature Range S8 OF to 302 OF, Divisions 0.1 OF. Accuracy at +23 °C/+73 OF is 0.1 % t0.2 °Cl0.4 OF, Serial #02110924, Cal. Date: 4-7-15 Cal Cert. Speedy Moisture Gauge 4-10-15 R.B. Aecom 0126071 2-9-16 Print Date: 08/07/2015 Cert#: FL10087 Page 1/2 L.• Atlantic Supply, Inc. Gauge Calibration Report Gauge Model: 3440 Serial Number: 37202 Calib. Date: 08/07/2d75 Expires: 08/06/2016 Block Type Low Med High Density 109.5 137 170.6 SIN 12-1 12-2 12-3 Depth Density Calibration Counts BS 1087 744 478 2 3864 2559 1540 3 4005 2597 1488 4 3906 2478 1372 5 3586 2208 1187 6 3166 1855 937 7 2661 1506 737 8 2174 1177 544 9 1763 910 403 10 1362 679 293 11 1058 514 208 12 810 373 152 'Gauge Constants: @125 pcf Depth ------ A ---------- Bx1000 ---------- C ---------- Repeatability ------------- BS 2.80453 1.02988 -0.03756 0.58 2 10.42735 1.00693 0.01435 0.28 3 11.05026 0.98740 0.12361 0.26 4 11.60810 1.02527 0.13748 0.26 5 12.36692 1.12519 0.08279 0.25 6 13.49980 1.25277 0.05934 0.25 7 13.56647 1.36682 0.02555 0.26 8 13.34331 1.47449 0.01977 0.27 9 13.80528 1.62426 0.00271 0.28 10 -- 1-2.85747 1.73893 -0.00540 0.31 11 10.38878 1.74965 0.00611 0.34 12 11.65229 1.99237 -0.00991 0.37 Moisture Parameters: Block Type Low MagPoly Density 0 34.9 SIN 12-1 12-4 Moisture Cal Counts 22 403 Gauge Constants 0.03198 0.99048 Density Std. Cnt: 2139 Moisture Std. Cnt: 688 Bay Number: 2 SCANNEb BY St. Curie Cni,nr, @15 pcf Repeatability 0.31 All measurements are in pcf unless otherwise stated. B A F are in xg/m3 Service Center: Atlantic Supply, Inc. 3740 Prospect Ave Unit 4 Riviera Beach, FL 33404 Print Date: 08/07/2015 Gauge Model: 3440 Serial Number: 37202 Calib. Date: 08/07/2015 Date Aug 15 Sep 15 Oct 15 Nov 15 Dec 15 Jan 16 Feb 16 Mar 16 Apr 16 May 16 Jun 16 Jul 16 Aug 16 Sep 16 Oct 16 Nov 16 Dec 16 Jan 17 Feb 17 Mar 17 Atlantic Supply, Inc. Calibration Technician Cert#: FL10087 Atlantic Supply, Inc. Expected Std. Count Expires: 08/06/2016 From To 2118 2160 2114 2156 2109 2152 2105 2148 2101 2144 2097 2140 2093 2136 2089 2131 2085 2127 2081 2123 2077 2119 2073 2115 2069 2111 2065 2107 2061 2103 2057 2099 2053 2095 2049 2091 2045 2087 2042 2083 Date Page 2/2 Density Std. Cnt: 2139 Moisture Std. Cnt: 688 Bay Number: 2 Service center: Atlantic Supply, Inc. 3140 Prospect Ave Unit 9 Riviera Heat.. M 33404