Loading...
HomeMy WebLinkAboutSTRUCTURAL ANALYSIS REPORTSCANNED BY ■ VELOCITEL St. Lucie County 'i ENGINEERING INNOVATION FDH Velocitel, 6521 Meridian Drive Raleigh, NC 27616, Ph. 919.755.1012 Structural Analysis for I SBA Network Services, Inc. 300' Guyed Tower SBA Site Name: Midway Road CPO SBA Site ID: FL10049-A-0 T-Mobile Site ID: A2P0038 `. FDH Velocitel Project Number 15BWAR1400 (R1) Analvsis Results Tower Com onents 91.7% Sufficient Foundation 92.6% Sufficient Prepared By: (� t R—e_viewwed By: Mustafa Mannar, El J. Scott Hilgoe, PE Project Engineer I Senior Project Engineer FL PE License No. 78300 Velocitel, Inc. COA 28282 \`�III{{tfll///0// �Velocit 1, In Me derDlH Velocitel — \��GOTT H/(G // �� VC ENS -0—/i— Raleigh-N627616— (919)755-1012 No.78300 info(c fdhvelocitel.com o STA E OF 400: W �CORO G\�\\. All - July 28, 2015 Prepared pursuant to ANSYTIA-222-G Structural Standard for Antenna Supporting Structures and Antennas and 2014 Honda Building Cade Document No. ENG-RPT-503S Revision Date: 07/05/11 0 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 TABLE OF CONTENTS EXECUTIVE SUMMARY........ Conclusions ....................... Recommendations ............. APPURTENANCE LISTING... RESULTS ............................... GENERAL COMMENTS ........ LIMITATIONS ......................... APPENDIX ............................. Document No. ENG-RPT-503S Revision Date: 06/17/11 2 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 EXECUTIVE SUMMARY At the request of SBA Network Services, Inc., FDH Velocitel performed a structural analysis of the existing guyed tower located in Fort Pierce, FL to determine whether the tower is structurally adequate to support both the existing and proposed loads pursuant to the Structural Standard for Antenna Supporting Structures and Antennas, ANSIITIA-222-G and the 2014 Florida Building Code (FBC). Information pertaining to the existing/proposed antenna loading, current tower geometry, geotechnical data, the member sizes, and foundation dimensions was obtained from: ❑ Alcoa Wireless Services, Inc. (Project No. 1608.244) Structural Analysis of 300' Guyed Tower dated August 18, 2004 ❑ Rohn (Eng. File No. 45476WM) Foundation Schedule dated September 12, 2001 ❑ FDH Engineering, Inc. (Project No. 12-01109EG1) Geotechnical Evaluation of Subsurface Conditions dated February 6, 2012. ❑ FDH Engineering, Inc. (Project No. 12-01109E S2) Modification Drawings for a 300' Guyed Tower dated August 29, 2012 ❑ FDH Engineering, Inc. (Project No. 12-01109E S6) Modification Drawings For A 300' Guyed Tower dated March 13, 2013 ❑ FDH Engineering, Inc. (Project No.1302121700) Modification Inspection Report dated September 3, 2013 ❑ FDH Engineering, Inc. (Project No.1302121700)TIA Inspection Report dated March 20, 2014 ❑ SBA Network Services, Inc. The ultimate design wind speed per the 2014 FBC is 159 mph without ice. This is converted to a basic design wind speed per the ANSIIFIA-222-G standard and 2014 FBC Section 1609.3.1 of 123 mph. Furthermore, this structure was analyzed as a Class II structure in Exposure Category B, Topographical Factor of 1, and Spectral Response Accelerations of Ss = 0.067 and S, = 0.029. Note: Per Section 2.7.3 of the ANSIITIA-222-G standard, the seismic/earthquake loading effects can be ignored if spectral response acceleration at short periods (Ss) is less than or equal to 1.00. The tower's location mandates a design Ss of less than 1.00, thus seismic loading was not considered as part of the analysis of this structure. Conclusions With the existing and proposed antennas from T-Mobile in place per Table 1, the tower meets the requirements of the ANSIITIA-222-G standard and the 2014 FBC standards provided the Recommendations listed below are satisfied. Furthermore, provided the foundations were constructed per the original design drawings (see Rohn Eng. File No. 45476WM) and utilizing the existing soil parameters (see FDH Engineering, Inc. Project No. 12-01109EG1) the foundations should have the necessary capacity to support both the proposed and existing loading. For a more detailed description of the analysis of the tower, see the Results section of this report. data, tower layout, existing antenna loading, and proposed antenna loading) and that the tower has been and maintained per the original design drawings. Recommendations To ensure the requirements of the ANSIIFIA-222-G standard and 2014 FBC standards are met with the existing and proposed loading in place, we have the following recommendations: 1. Feed lines must be installed as shown in Figure 1. 2. The existing feed lines should be re -used with the proposed loading. 3. The passing result is contingent on the existing Nextel equipment at 175' removed as shown in Table 1. Document No. ENG-RPT-503S Revision Date: 06/17/11 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 APPURTENANCE LISTING The proposed and existing antennas with their corresponding feed lines are shown in Table 1. If the actual layout determined in the field deviates from the layout, FDH Velocitel should be contacted to perform a revised analysis. Table 1 - Appurtenance Loading Existing Loading: Antenna Mount Elevation Descdption Feed Lines' Carrier Elevation MountType 308 (2)16lt Omnis (2) 7/8= Waste Management 300 (2) 5' Standoffs 272 1 Hustler HX9-45070 (1) 7/8 Scripps 259 (3) 5' Standoffs 262 1 24"x24"x7 TMA Broadcastin (6) Cellmax CMA-BDHH/6520/EO-8 256.5 3 2' Standoffs (3) Cellmax CMA-B/6520/EO-8 256 (2) Nokia FXFB (12)1-5/8" T-Motile (3) Nokia FRIG (1) 1.584"Hybrid 254.5 (3) 15'T-Frames (3) RFS ATMAA14i2D-WO 1 Raycalp ASU9338TYPOl 240.8 1 19.5' Omni 1 7/8" Suntalk 231.5 1 5' Standoff 238 (1)10' Dipole (1) 7/8" Repeater Network 233 (1) 5' Standoff 175 9 Decibel DB848H90E-XY (9)1-5/8- Nexte12 173.5 3 ITT -Frames (3) RFS APXVERR18-C (3) Commscope TTTT65AP-1XR (3) Flexi RF Remote Unit Outdoor-FZHJ (3) Ericsson RRU 11 800 MHz (3)1-1/2" Hybrid 151 (9) Ericsson RRU 11 1900 MHz Cables Sprint 149.5 (3) 10'T-Frames (3) RFS A2 Module (1) 0.80 (6) RFS IBC1900HG-1 (9) RFS ACU-A20-N 6 Ericsson ESMR 800 140 (6) CSS X7CAP-665-42 (18)1-5/8" Verizon 140 (3) T-Frames amont RMV 12-372 98 (1)11"Camera (1) CAT 5 Scripps Broadcasting 98 Direct Mount 1. Feed lines must be installed as shown In Figure 1. 2. Nextel's existing equipment at 175' to be removed and not included in analysis. Proposed Carrier Final Loading: (3) Andrew DBXNH-6565B-A2M 256 (2) Nokia FXFB (3) Nokia FRIG (3) RFS ATMAA14l2D-WO (12)1-5/8" (1)1.584" T-Mobile 256.5 (3)15'T-Frames Hybrid Document No. ENG-RPT-503S Revision Date: 06/17/11 4 RESULTS Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 July 28 2015 The following yield strength of steel for individual members was used for analysis: Table 2 - Material Strength Member Type Yield Strength Table 3 displays the summary of the ratio (as a percentage) of force in the member to their capacities. Values greater than 100% indicate locations where the maximum farce in the member exceeds its capacity. Note: Capacities up to 105% are considered acceptable. Table 4 displays the maximum foundation reactions. If the assumptions outlined in this report differ from actual field conditions, FDH Velocitel should be contacted to perform a revised analysis. Furthermore, as no information pertaining to the allowable twist and sway requirements for the existing or proposed appurtenances was provided, deflection and rotation were not taken into consideration when performing this analysis. See the Appendix for detailed modeling information. Table 3 - Summary of Working Percentage of Structural Components Elevation ComponentSection No. a Type Fail T1 300 - 280 Leg ROHN 2.5 EH 26.6 Pass Diagonal P1.5x.058 57.7 Pass Top Girt P1.5x.058 Pass 43'3b Bottom Girt P1.5x.058 Pass 1492b Guy A 282.523 718 68.1 Pass Guy B 282.523 718 67.9 Pass Guy C 282.523 7/8 68.3 Pass Top Guy Pull- 2L2x2xl/4 11.0 Pass Off 282.523 T2 280 - 260 Leg ROHN 2.5 EH 71.9 Pass Diagonal P1.5x.120 50.3b Pass 70.5 _ Top Girt P1.5x.120 16.3 Pass 29.8b — - — Bottom_Gia P.1.5x.120_ - _ _ - - =222 b = _ Pass- = = -- -- _ T3 260-240 Leg ROHN 2.5 EH - 61.8 Pass Diagonal P1.5x.058 54.8 Pass Top Girt P1.5x.058 Pass 6.6 b Bottom Gin P1.5x.058 i Pass 9.4) T4 240 - 220 Leg ROHN 2.5 EH 54.1 Pass Diagonal P1.5x.058 67.6 Pass 72.1 b Top Girt P1.5x.058 1428b Pass Bottom Girt P1.5058 11.1 Pass 20.1 b Document No. ENG-RPT-503S Revision Date: 06/17/11 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 Section No. Elevation it Component Type Fail Guy A 22.523 7/8 80.5 Pass Guy B 222.523 7/8 80.4 Pass Guy C 22.523 7/8 80.4 Pass Top Guy Pull- 2L2x2x1/4 16.2 Pass Off 222.523 T5 220 - 200 Leg ROHN 2.5 EH 54.3 Pass Diagonal P1.5x.058 91.7 Pass Horizontal L2x2x1/4 4.8 Pass Top Girt P1.5x.058 17'2 Pass 30.4 b Bottom Girt P1.5x.058 .5b Pass 11 T6 200 -180 Leg ROHN 2.5 EH 58.8 Pass Diagonal P1.5x.058 59.4 Pass Horizontal L2x2xlA 5.2 Pass Top Girt P1.5x.058 Pass 94'2b Bottom Girt P1.5x.058 11'3 Pass 20.5 b T7 180 -160 Leg ROHN 2.5 EH 84.0 Pass Diagonal P1.5x.058 53.1 Pass Top Girt P1.5x.058 Pass 156 b Bottom Girt P1.5x.058 Pass 1249b T8 160 -140 Leg Rohn 3 EHH 67.6 Pass Diagonal P1.5x.120 63.3 Pass 74.8 b Top Girt P1.5020 Pass 73.9 Bottom Girt P1.&A20 12'7 Pass 25.7 b Guy A 142.523 3/4 64.9 Pass Guy B 142.523 314 64.9 Pass Guy C 142.523 314 64.9 Pass Torque Arm C1503.9 51.4 Pass To 142.523 T9 140 -120 Leg ROHN 3 EH 90.8 Pass Diagonal P1.5x.058 66.3 Pass Tap Girt P1.5x.058 13'4 Pass 24.3 b Bottom Girt P1.5x.058 8.5 Pass T10 120 -100 Leg ROHN 3 EH 68.6 Pass _ Diagonal- _ PlZx.05a� 58.9- -Pass -- - --- - - -- - - -- - �- Horizontal-� - �L-Wx1/4-- =8.2 _ --Pass = Top Girt P1.5x.058 56b Pass 17 Bottom Girt P1.5x.058 Pass 1 05b T11 100-80 Leg ROHN 3EH 78.2 Pass Diagonal P1.5020 52'1 Pass 61.5 b Horizontal L2x2x1/4 9.4 Pass Top Girt P1.5x.120 Pass 10.O9b Bottom Girt P1.5020 106 Pass 21.1 b Gu A 80AW 518 77.0 Pass Document No. ENG-RPT-503S Revision Date:06/17/11 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 Section Elevation Component No. ft Type Size % Capacity Gu B 80.1146 518 77.1 I Pass Guy C 80.1146 5/8 77.1 Pass Top Guy Pull- 2L2x2xl/4 12.2 Pass Off 80.1 US T12 80 - 60 Leg Rohn 3 EHH 65.5 Pass Diagonal P1.5x.120 63'7b Pass 75.2 Top Girt P1.5020 15.8 Pass 32.0 b Bottom Girt Pi.5x.120 Pass 1464b . T13 60 -40 Leg ROHN 3 EH 88.0 Pass Diagonal P1.5x.058 69.4 Pass Top Girt P1.5x.058 11'0 Pass 19.9 b Bottom Girt P1.5x.058 Pass 844b T14 40 - 20 Leg ROHN 3 EH 88.2 Pass Diagonal P1.5x.058 50.6 Pass Top Girt P1.5x.058 5 6 Pass 6b Bottom Girt P1.5x.058 Pass 169.1 b T15 20-5 Leg ROHN 3EH 81.9 Pass Diagonal P1.5020 34.9 Pass 41.3 b Top Girt P1.5x.120 .1 Pass 12 b Bottom Girt P1.5x.120 24.6 Pass 49.7 b T16 5-0 Leg HN3EH 64.1 Pass Horizontal L3x3x1/4 26.9 Pass Table 4 - Maximum Base Reactions Document No. ENG-RPT-503S Revision Date: 06/17/11 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 GENERAL COMMENTS This engineering analysis is based upon the theoretical capacity of the structure. It is not a condition assessment of the tower and its foundation. It is the responsibility of SBA Network Services, Inc. to verify that the tower modeled and analyzed is the correct structure (with accurate antenna loading information) modeled. If there are substantial modifications to be made or the assumptions made in this analysis are not accurate, FDH Velocitel should be notified immediately to perform a revised analysis. LIMITATIONS All opinions and conclusions are considered accurate to a reasonable degree of engineering certainty based upon the evidence available at the time of this report. All opinions and conclusions are subject to revision based upon receipt of new or additional/updated information. All services are provided exercising a level of care and diligence equivalent to the standard and care of our profession. No other warranty or guarantee, expressed or implied, is offered. Our services are confidential in nature and we will not release this report to any other party without the client's consent. The use of this engineering work is limited to the express purpose for which it was commissioned and it may not be reused, copied, or distributed for any other purpose without the written consent of FDH Velocitel Document No. ENG-RPT-503S Revision Date: 06/17/11 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 July 28, 2015 APPENDIX Document No. ENG-RPT-503S Revision Date: 06117/11 Structural Analysis Report SBA Network Services, Inc. SBA Site ID: FL10049-A-03 A -LEG (320') (3)1-11Y EXISTING HYBRID CABLES 0 (1) 0.867- EXISTING FEED LINE '-�O FOR SPRINT TO 149.5' (5) 718- EXISTING FEED LINES O (1)CAT 5CABLE TO 98', 231.5, 233', 259' AND 300' (9) 1-5/8-EXISTINGFEED LINES FOR NEXTEL TO 173.6 (O BE REMOVED) / (18)1-5f8' EXISTING FEED LINES FOR VERIZON TO 140' Q= EXISTING ®= TO BE REMOVED 0= PROPOSED Figure 1— Feed Line Layout 1-518' EXISTING FEED LINES .584' EXISTING HYBRID CABLE T-MOBILE TO 256' Document No. ENG-RPT-503S Revision Date: 06117h 1 10 a 'a a `n d d z z w z 0 0 6 M1 G d z � w N N d F a � � 6 � z a e w a s a S a rc s w F 4 ul __— z z 0 0 Q Q Q Q 0 U ALL REACTIONS ARE FACTORED FDH Velocitel ' t6521 Meridian Drive Raleigh, North Carolina 27616 Phone: 919.755.1012 FAX: 919.755.1031 ab Midway Road, FL10049-A-03 PfOfB-: 15BWAR1400 R7 ciiam: SBA Network Services, Inc DrawnbyM.Manna APPde Catle' TIA-222-G Dale:07/27/15 sm" NTS P.M: 11" No.E-1