HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online
Page 1 of 2
f-
* y 4 F f•_ L4
pePJTCA3rW4A ,07dN,
rnW"a'_i
BUS home j tog in 'User Registration I Not Topics j Submit Surcharge 1 stars a Facts I Publications • FBCStaff 1 BCIS Site Map I (inks Search
i#11 `. Product Approval '
Ya USER: PUEIic User ��/�
P,M "Ithnn,mrnl Mann> PMtl M nr Gnn'rartnn S-11h > appara, <.> application u ST. LI1 TE COUNTY RTju ,ivt7 nmsiov
eftWE VED FOR CONW1IVCE
FL # FL17443 REVIE"VED BY u �l
Application Type New DATE
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Emall
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Approved
WILL BE NUDE.
JOB
A TAYLOR ROOFING
THESE PLANS AND ALL PROPOSED WORK
302 Melton Drive
FT PIERCE, FL 34982
,.
'. ARE SUBJECT TO ANY CORRECTIONS.:.
(772)466-4040
BY INSPECTORSTHAT.
Bvalidation@yahoo.com
-REQUIRED -FIELD
MAY BE NECESSARY IN ORDER TO;.f
Bvaiidatlan@yahoo.com
WITH ALL'APPLIGI,A®LE C®DES'-
_COMPLY
Category Roofing,
Subcategory - Metai Roofing
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OFTHE
CONTRACTOR OF RECORD
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License PE-49704
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Certificate of independence
Keystone Certifications, Inc.
04/11/2021
Hermes F. Norero, P.E.
FL17443 RO COI ocke Bowden P E odf
Referenced Standard and Year (of Standard) standard year
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D 0*1 L E Py
https9/floddabuilding.org/pr/pr app_ tl.aspx?param-wGEVXQwtDgtCUGgvjQiz6AP/2brQi3pbzvra%2tin/o2flbg7g2KOBRzEzIHXSCw%3dP/o3d July28,2015
Florida Building Code Online Page 2 of 2
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
03/02/2015
03/02/2015
03/05/2015
04/15/2015
FL if I Model, Number or Name I Description
117443.1 ( 5 V Crimp 126GA 1/2" rib height over 15/32" plywood
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design laressure: +N/A/-129.25
Other:-129.25 @6" P.C. -59.25 @16" o.c. margin of safety
2 1 with 24' max. coverage Install per manufacturers detail.
Not for use in HVHZ.
Installation Instructions
FL17443 RO II 5 V Crimp Fastening Deta I odf
Verified By: PRI Construction Materials Technologies, LLC
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RO AE FL 174413. A Tavlor Rooting_5 V Crimp
Report-ss.odf
Created by Independent Third Party: Yes
IIeCW neat
rondo 1k ;;'lobo t nnh finance cared TalUhacmo FIL 3139Q Phone- n5nde7-1814
The State of Florida Is an AA/EEO employer, rnnvripht 70117-7m a. date of Flnr da :; P lvary n"romn"t ;; e,.neamdro eeatrment Aehmd eram,nent
under Florida law, emall addresses are public records. If YOU do not want your e-mail address released In response W a public,records request, do not send electronic
mail to this entity: Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to Section
455.275(i), Florida Statutes,. effective October1,. 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
.One_ The emall5 provided may be used for official communnetion with the licensee. However email addresses are public record. If you d0 not wish to supply a personal
address,'. please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455,-F.S..
please dick lo'm
Product Approval Accepts:
®ER M
Credit5Ar
https:!/goddabuilding.org/pr/pt_ app. dU.aspx7param=wGEVXQwiDgtCUGgviQiz6A%2brQi3pbzvra%2b%2flbg7g2KOBRzEzIHXSCw°/a3d%3d July 28, 2015
Locke Bowden, P.E.
9450-Alysbury Place
Montgomery, AL 36117 FL # 17443
JA Taylor Roofing Inc
302 Melton Drive
Fort Pierce, FL 34982
Product:
5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel, 24" net coverage,
26GA rein. over m_in.1552" thick•CDX plywood decks.
Compliance.: Florida Building Code (FBC) 2014; Section 1504.3.2, Section 1507.2.8, Section 1507.4.3
UL580 "Tests. for Uplift Resistance"'
Description: Architectural:metal roof panel, 26 gauge metal panels; over min. 15/32"CDX plywood
and shall comply with Florida Building Code 2014, Section 1507.4.3
Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2
Deck -Slope 2 f 2 or greater and shall be:compliant with Florida Building Code 2014, Section 1507.4.2.
Design Pressure: 129.25 psf @ 6"o.c. and-69.25psf @16" o.c.; Fasten along the crown of the rib in the
center of panel and along the lap. Design.pressure includes safety factor =2.0. First fastener to be within 3"
of panel edges. Mn. 8d x'2" annular ring shank nails spaced 6" o.c. reroofing, with less than 19/32" plywood
9min. 15/32" ), this attachment into be used, in addition to existing attachment. Deck attachment to be by
other design professional.
Underlayment::approved product in compliance with FBC 2014, Section 1507.2.8
Thru-fastened over, mn.15/32" plywood
Fasteners: #9-15 HWH corrosion resistant fasteners with sealing washers, metal to wood connections with
fastener length to penetrate 5/16" through substrate per Florida Building Code 2014, Section 1507.4.4
Conditions of Use: Not for use in HVHZ. Install per manufacturer's instructions and must be designed
In compliance with Florida Building,Code,2014. Manufacturer is compliant with Rule 61G20-3; wherein
manufacturer complies under' -A quality assurance program audited by approved
Quality Assurance Entity; Keystone Certifications valid thru 4/11/2021
b. Reference-TestReport0224-0561-06HurricaneTest Laboratory „(itltlrty
C. Test equivalency. standard, -.the UL 580-94,test standard is equiKctll'hC10 fflQ �h5,80-06
d. Quality- Assurance Procedures and Documentation
p� 4�GENSe °•cy�'�'
No.49704 °
2
0
•
e",_.
1'Ca�Nz
FL
This report does not guarantee or wartanty any product validated or installed. Manufactun:r's warranty applies.
V Crimp
Fastener- #M 5 corrosion resistant w/sealing washers
24"coverage
Fastener: #9 x 16 corrosion resistant with sealing washers
in Compliance With 2014 Florida Building Code, Section 1507.4.4
Perimeter fastening: 6"o.c.
Main. Field fastening12"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel
` q rt�
�n,aWa�WP�PIMPM� . _ � .. I4Y ,� •� ' [;• II '
r
��8us�ness &yProfessiodahRegulation fTM�t� r.
i�F j; ti.t; *�, 1 ,' < ♦: t � • .r ., ' Darn tlove:' �eour oera PaPnoinslorn' [dr1ACT.beM
Busines�(`1
ProductAppr6val
a
Professi 1 al
USER: Public User
Regulation
•
P,er .rt Aec,, ,l Mr,,, > rntl ,, fir Are,, 1
fin Srarrh > Ann r+lfrh 1 ic, > APPIIcatiers petuil
FL *
FL17443
Application Type
New
Code Version
2014
Application Status
<Z::Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
3 A TAYLOR ROOFING
302 Melton Drive
FT PIERCE, FL 34982
(772) 466.4040
flvalldation@yahoo.com
Kyle Taylor
Ovalidation@yahoo.com
SCBNNED
StLucie Count,
t /
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
I Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/11/2021
- — - --_ °- -- —^ slidated-By--- — — -- —---Hermes_F.-Norero.-P.E.
'—Validation.Checklist --Hardcopylieceived- -
Certificate of Independence FL17443 RO COI Certificate of Ind end Locke Bowden P E odf
Referenced Standard and Year (of Standard) Standard Year
ULS80 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
httpsJ/floridabuilding.orglpr/pr_app_d8.aspx7param=wGEVXQwtDgtCUGgviQiz6A%2brQi3pbzvmP/o2b°/,2flbg7g2KOBRzEzIHXSCw%3d%3d July 28, 2015
Florida Building Code Online Page 2 of 2
Date Submitted 03/02/2015
Date Validated 03/02/2015
Date Pending FBC Approval 03/05/2015
Date Approved 04/15/2015
FL #
Model, Number or Name
Description
17443.1
5 V Crimp
26GA 1/2" rib height over 15/32" plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17443 RO it 5 V Crimp Fastening Detail Ddf
Approved for use outside HVHZ: Yes
Verified By: PRI Construction Materials Technologies, LLC
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-129.25
Evaluation Reports
Other:-129.25 @ 6" o.c. -69.25 @16" o.c. margin of safety
FL17443 RR AE FL 17443 7. A. Taylor Roofing 5 V Crimp
2:1 with 24" max. coverage Install per manufacturers detail.
Report-ss.pdf
Not for use In HVHZ,
Created by Independent Third Party: Yes
pnrN Nc,f
CcrM&IIs::l n40 North Memms4rnet Tallah—ppR ilia'Pbnne- PCn.4117-1P]4
The State of Florida Is an AA/EIO employer. Cnovdnht 7nm-on11 state of nnrina_ :: Pri„ cv 9ram,nent :: Arrp.ahnnv ctammpnt :: imf and snA mpy
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.'Pursuant to Section
455.275(1), norlda Statutes, effective October 1, 201Z licensees [teemed under Chapter 455, F.S. must provide the Department with an email address If May have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. if You do not wish to supply a personal
address, please provide the Department with an email address which can be made available ro the public To determine If you are a licensee under Chapter 455, F.S.,
please click hate-.
Product Approval Accepts:
® ®=l E
stturitv"l l.",
httpsJ/floddabuilding.org/prfpr ppp_riff.aspx?param=wGEVXQwtDgtCUGgvjQiz6A%2brQi3pbzvra%2b%2flbg7g2KOBRzEzIHXSCwa/p3da/o3d July 28, 2015
Locke Bowden, P.E.
9450 Alysbury Place
Montgomery, AL 36117 FL # 17443
JA Taylor Roofmg Inc
302 Melton Drive
Fort Pierce, FL 34982
Product:
5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel, 24" net coverage,
26CA min. over min.15/32" thick CDX plywood decks.
Compliance: Florida Building Code (FBC) 2014; Section 1504.3.2, Section 1507.2.8, Section 1507.4.3
UL580 "Tests for Uplift Resistance"
Description: Architectural metal roof panel, 26 gauge metal panels; over min. 15/32"CDX plywood
and shall comply with Florida Building Code 2014, Section 1507.4.3
Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2
Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2.
Design Pressure:-129.25 psf @ 6"o.c. and-69.25psf @16" o.c.; Fasten along the crown of the rib in the
center of panel and along the lap. Design pressure includes safety factor =2.0. First fastener to be within 3"
of panel edges. Min. 8d x 2" annular ring shank nails spaced 6" o.c. reroofing, with less than 19/32" plywood
9min. 15/32"), this attachment is to be used in addition to existing attachment. Deck attachment to be by
other design professional.
Underlayment: approved product in compliance with FBC 2014, Section 1507.2.8
Thru-fastened over min. 15/32" plywood
Fasteners: #9-15 HWH corrosion resistant fasteners with sealing washers, metal to wood connections with
fastener length to penetrate 5/16" through substrate per Florida Building Code 2014, Section 1507.4.4
Conditions of Use: Not for use in HVHZ. Install per manufacturer's instructions and must be designed
In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61G20-3; wherein
manufacturer complies under a quality assurance program audited by approved
Quality Assurance Entity; Keystone Certifications valid thru 4/11/2021
--E-vidence-Subuflued:
b. Reference -Test Report 0224-0501-06 Hurricane Test Labo
C. Test equivalency standard — the UL 580-94 test standard is
d. Quality Assurance Procedures and Documentation
awLY �pisnnHrp
:quilnVoBOj 5,80-06
No.49704 s
' �• STAT���
2
FLft' ��II9,7lIl��e``r
This report does not guarantee or warranty any product validated or installed. Manufacturer's warranty applies.
a V Crimp
Fastener- #9-15 corrosion resistant w/sealing washers
24"coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2014 Florida Building Code, Section 1507.4.4
Perimeter fastening: 6" o.c.
Main Field fastening 12"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel