Loading...
HomeMy WebLinkAboutROOF PLAN-rA o Si/t N 17 A. 10 .56 v6tvo L� N r" T reasure Harvey E. Koehnen C oast Professional Engineer #32831 B uilding Architect #AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. Contractor J. A.Y;.t(LOR Owner lNpRtO &AP -se SG{�o eL Job Address 3860 100140 RA• METAL ROOFING 5'V JA r tYLo 6L, Z� AA NEW ROOF_ RE -ROOF_ 4 REPAIR_ AREA 2S541 METAL ROOF PLAN 7205 Elyse Circle SDABVNED P S L Florida 34952-8212 PHONE(772) 466-5509 a St CurfO ^nll FAX(772)489-303S nfi E-MAIL:hkoehnen@tcbeweb.com Date 10/65/L5 ASCE 7-10 & FBC 2014 5th Edition ENCLOSED BLDG X SEMI ENCLOSED BLDG OPEN PART 2 LOW RISE C&C SIMPLIFIED ZONE IP@ @ h=30 = X = PSFx0.6= —2?•Q, ZONE 2P@ @ h=30 = X = PSFx0.6=-321� a= 3�3, ZONE 3P@ @ h=30 = X = PSFx0.6=-3?'4- a=' Y_53 MAX DESIGN PRESSURE PER NOA DECKTYPE PLHVJ a0 THICKNESS 15 2A F"At �SPACING BASE SHEET AD fr NO. OF PLIES 1_ FA TEENEWPE PLY SHEET NO. OF PLIES FASTENERTYPE SPACING - TOP PLY ^ NO. OF PLIES - FASTENER TYPE - SPACING - INSULATION BASE LAYER TYPE - SIZE - TYPE OF FASTENERS: SPACING FIELD PERIMETER _ CORNERS — INSULATION TOP LAYER TYPE — , SIZE — TYPE OF FASTENERS/OR•B9Po9HJG MATERIAL J5/t WO (400 SP.sr tNA W. =S, DRIP EDGE SIZE Owlt DRIP MATERIALZ&&A, Q,1. FLASHING MATERIAL I&dk A, I tl+ T reasure Harvey E. Koehnen C oast Professional Engineer #32831 B uilding Architect #AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. These Tables Are For Hoof Coverings Roof coverings Installed on Buildings with a Mean Roof Helght of 30' or Less Located In Exposures B, C or D TableR301.2[2]_QFR ptyu c. a.5-rQscE7-Id COMPONENTS AND CLAODING WORST CASE DESIGN PRESSURE [PSF]. 180 Exp B 160 Exp C 160 Exp, C 160 Exp D 160 Exp D (One story . (Two story*) (One story*) (Two story' Roof> 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9 7degrees = 11/2112 pitch Zone 2 -46.4 -56.2 -65.0 -68.3 -77.1 Zone 3 -69.8 -84.5 -97.7 -102.7 -116.9 Roof > 7 to 27 degrees 'Zone 1 -25.3 - 30.7 - 35.5 -37.2 - 42 27 degrees = 6/12 pitch Zone 2 -44.1 - 63.4 - 81.8 -64.9 - 73,3 Zone 3 -65.1 -78.8 - 91.2 - 95.7 - 108=1 Roo, > 27 to 45 degrees Zone 1 - 27.8 -33.7 -40,0 -40.1 -462 �5 degrees = 12112 pitch Zone 2 - 32.4 -39.3 -45.4 -47.7 -53.8 one 3 - 32.4 -39.3 -45.4 - 47.7 -53.8 Exp B 150 Exp C 150 Exp C 150 Exp D 150 Exp D .150 (one story*) ( two story*) (one storyl ( two storyl Roof> 0 to 7 degrees Zone 1 -24.3 -29.5 -34.1 -35.8 -40.4 7degrees = 1112112 pitch Zone 2 -40.8 -49A -57.2 -60.0 -67.8 Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0 Roof > 7 to 27 degrees Zone 1 -22.2 - 26.9 - 31.1 -32.7 - 36.9 27 degrees = 6112 pitch Zone 2 -38.7 - 46.9 -54.2 -56.9 - 84.3 Zone 3 . -57.3 - 69.4 - 80.3 -84.3 - 95.2 -t3oof> 27�to_-45 degrees-Zone=1 -24:3 ' :29.5 -34:1 -35� -,40c4 - - - 45 degrees = 12/12,pitch Zone 2 -,28.4 -34.4 -39.8 -41.8 -47.2 Zone 3 - 28.4 -34.4 -39.8 -41.8 -47.2 One story* = one story building with a maximum mean roof height of 15 feet Two story* = two story building with a maximum mean roof height of 30 feet If allowed by the Miami Dade N.O.A or Florida Product Approval, any system.that does not meet the minimum components and cladding pressures for the area that the building is located per this form may require a Florida licensed engineer to revise the fastener spacing T C B E, Inc. 7205 Elyse Circle PHONE (772) 466-5509 Port Saint Lucie FAX (772) 489-3035 Florida 34952-8212 E-MAIL hkoehnen@tcbE