HomeMy WebLinkAboutSTRUCTURAL ANALYSIS REPORTAMERICAN TOWER® C O R P O R A T I O N Structural Analysis Report Structure : 300 ft Self Supported Tower ATC Site Name : Midway Road, FL ATC Site Number : 5100 Engineering Number : 63511322 Proposed Carrier : T-Mobile Carrier Site Name : ATC Ft. Pierce West Carrier Site Number : A2P0047A Site Location : ff5690�viFonmee-ntI Fort Pierce, FL 34981-4811 27.379592,-80.382100 County : Saint-LuEie Date : ` September 3, 2015 Max Usage 83 b 1 a Result Pass SCANNED BY St'luCie County \\IIIIIII�� ishua J.-Ferguson �N"� pp� No. 771D5 ATE� FL0RO G-Z- � NAI- COA: 9053 ATC Tower Services LLC -3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office -919466-5424 Fax-www.americantower.com A AMERIGAN TOWER• CORPORATION Eng. Number 63511322 September 3, 2015 Table of Contents - . Introduction.................................................................................................................................... 1 SupportingDocuments.................................................................................................................... 1 Analysis........................................................................................................................................... 1 Conclusion....................................................................................................................................... 1 Existing and Reserved Equipment..................................................................................................... 2 Equipment•to be Removed............................................................................................................... 2 ProposedEquipment ....................................................................................................................... 2 Structure Usages ......... :............. ........ 3 Foundations .................................... .............................................. ............ ......... .......... .................... 3 Deflection, Twist, and Sway ........ .... ...... ..... ..... :....... ............. .... ........................................... 0.............. 3 StandardConditions .................................. ........................................... ................ a ......... .................. 4 Calculations......................................................................................................................... Attached ATC Tower Services LLC - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919468-0112 Office - 919-466-5414 Fax - www.americantower.com A AMERICAN TOV VER° CORPORATION Eng. Number 63511322 September 3, 2015 Page 1 Introduction The purpose of this report is to summarize results of a structural analysis performed on the 300 ft self supported tower to reflect the change in loading byT-Mobile. Supporting Documents Tower Drawings Sabre Job #SA0737-S, dated October 17,1996 Foundation Drawing Sabre Drawing#9086965, dated November 1,1996 Geotechnical Report Universal Engineering Report #6157, dated October 15,1996 Modifications ATC Project #40091032, dated March21, 2007 ATC Project #47556932, dated October 18, 2011 Analysis The tower was analyzed using American Tower Corporation's tower analysis software. This program considers an elastic three-dimensional model and second -order effects per ANSI/TIA-222. Basic Wind Speed: 123 mph (3-Second Gust, V,up) / 159 mph (3-Second Gust, VuLT) Basic Wind Speed w/ Ice: No Ice Considered Code: ANSI[nA-222-G/20121BC/5th Ed. Florida BuildingCode Structure Class: II Exposure Category: B Topographic Category: 1 Spectral Response: Ss = 0.06, S3 = 0.03 Site Class: D - Strf Soil Conclusion Based on the analysis results, the structure meets the requirements per the applicable codes listed above. The tower and foundation can support the equipment as described in this report. If you have any questions or require additional information, please contact American Tower via email at Engineering@americantower.com. Please include the American Tower site name, site number, and engineering number• in the subject line for any questions. ATC Tower Services LLC -3500 Regency Parkway, Suite 300- Cary, NC 27518 - 919468-0112 Office-919466-5414 Fax-www.americantower.conn A AMERICAN TOWER° CORPORATION Existing and Reserved Equipment Eng. Number 63511322 September 3, 2015 Page 2 Elevation' (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 295.0 295.0 2 CSS AXP19-60-2 Sector Frames (12) 15/8" Coax Verizon 4 CSS AXP18-80-2 3 CSS X7-6654 278.0 284.5 1 MSW MSW5011-2 Leg (1)1/2" Coax Way Fin Media 265.0 265.0 6 Sector Frames (12)15/8" Coax Sprint Nextel Scala AP15185rA 179.0 179.0 3 RaycapASU9338TYPOl Sector Frames (12)15/8" Coax (3)1.24" Hybrid T-Mobile 6 CeIIMax CMA-BDHH/6520/E078 3 Nokia FXFB 3 Nokia FRIG w/o S.S. 3 RFSATMAA1412D-1A20 170.0 170.0 3 CommscopeTTrr65AP-1XR Sector Frames (3)11/4" Hybriflex (1) 0.87" Fiber Sprint Nextel 3 Nokia FZHJ 3 Ericsson RRUS 31 B25 3 Ericsson RRUS-11800MHz 9 RFSACU-A20-N 3 RFSAPXV9ERR18-C 155.0 155.0 3 Kathrein 80010764 K Sector Frames (12) 15/8" Coax (2) 0.76" 8 AWG 6 (1) 3/8" Coax (1) 0.39" Cable AT&T Mobility 6 Kathrein 80010121 6 RFSATM19201213-0 1 Raycap DC6- 48-60-18-SF 6 Ericsson RRUS 11(Band 12) (55lb) 3 Kathrein 78210254 6 Kathrein 86010025 6 RFS FDGW5504/3C-3 140.0 140.0 2 Andrew UHX6-59W Leg (4) EW52 120.0 120.0 1 Andrew UHX6-59W Leg (2) EW52 Verizon 100.0 1100.0 1 1 1 Andrew UHX6-59W Leg (2) EW52 Equipment to be Removed Elevation' (ft) City Antenna Mount Type Lines Carrier Mount RAD 179.0 179.0 6 CeIIMaxCMA-BDHH/6520/EO-8 - T-Mobile 3 CeIIMaxCMA-B/6520/EO-8 Proposed Equipment Elevation' (ft) QtV Antenna Mount Type Lines Carrier Mount RAD 179.0 1179.0 1 3 1 AndrewSBNHH-I[ Sector Frames - T-Mobile 'Mount elevation is defined as height above bottom of steel structure to the bottom of mount, RAID elevation is defined as center of antenna above ground level (AGL). ATC Tower Services LLC - 3500 Regency Parkway, Suite 100 -Cary, NC 27518-919468-0112 Office-919-466-5414 Fax- www.americantower.conn A AMERICAN TOWER° CORPORATION Structure Usages Structural Component Controlling Usage Pass/Fail Legs 66% Pass Diagonals 83% Pass Horizontals 68% Pass Anchor Bolts 419/a Pass Foundations Eng. Number 63511322 September 3, 2015 Page 3 Original Design Factored Design Reaction Component Analysis Reactions /o of Design Reactions Reactions* Uplift (Kips) 647.3 873.9 640.6 73% Axial (Kips) 724.8 978.4 780.0 80% *The design reactions are factored by 1.35 per ANSI/TIA-222-G, Sec. 15.5.1 The structure base reactions resulting from this analysis are acceptable when compared to those shown on the original structure drawings, therefore no modification or reinforcement of the foundation will be required. Deflection, Twist and Sway* Antenna Deflection Sway Elevation Antenna Carrier Twist (') (ft) (Rotation) (") (ft) 179.0 AndrewSBNHH-1D65B T-Mobile 0.137 0.004 0.083 140.0 Andrew UHX6-59W Verizon 1 0.085 0.003 0.067 120.0 Andrew UHX6-59W 0.063 0.060 100.0 Andrew UHX6-59W 1 0.044 1 0.002 1 0.049 *Deflection, Twist and Sway was evaluated considering a design wind speed of 60 mph (3-Second Gust) per ANSI/TIA-222-G ATCTower Services LLC - 3S00 Regency Parkway, Suite 200 -Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax-www.anrericantower.com AMERICAN TOWER" CONPD. AT... Standard Conditions All engineering services are performed on the basis that the information used is current and correct. This information may consist of, but is not necessary limited, to: Information supplied by the client regarding the structure itself, antenna, mounts and feed line loading on the structure and its components, or other relevant information. Information from drawings in the possession of American Tower Corporation, or generated by field inspections or measurements of the structure. It is the responsibility of the client to ensure that the information provided to ATC Tower Services LLC and used in the performance of our engineering services is correct and complete. In the absence of information to the contrary, we assume that all structures were constructed in accordance with the drawings and specifications and that their capacity has not significantly changed from the "as new" condition. Unless explicitly agreed by both the client and American Tower Corporation, all services will be performed in accordance with the current revision of ANSI/TIA-222. The design basic wind speed will be determined based on the minimum basic wind speed as prescribed in ANSI/TIA-222. Although every effort is taken to ensure that the loading considered is adequate to meet the requirements of all applicable regulatory entities, we can provide no assurance to meet any other local and state codes or requirements. If wind and ice loads or other relevant parameters are to be different from the minimum values recommended by the codes, the client shall specify the exact requirement. All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. ATC Tower Services LLC is not responsible for the conclusions, opinions and recommendations made by others based on the information we supply. ATC Tower Services LLC- 3500 Regency Parkway, Suite 100- Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com 300.00 SI-1 15 280.00 Sect 54 20.0O Sect 13 240.03 Sec1 12 220.DD Sect a 203.00 Sect 10 1&3.00 Sot 9 1 0.O0 S-t8 140.W Sert 7 1-1.0 Sect 6 100.00 Sect 5 60.00 Sct 4 60.00 Sect 3 40.00 Sect 2 20.00 Sect a Dasa Shear 02007-20156yATCIPLLC. Allrightsmsemv d. Loads: 123 mph no ice 0 mph w/ 0'0" radial ice Site Class: D Ss: 0.06 S1: 0.03 60 mph Serviceability Ice 0.00 k Job Information ' Tower: 5100 Location : Midway Road, FL Code: ANSI/TIA-222-G Shape :Triangle Base Width : 36.00 ft Client: T-MOBILE Top Width : 6.00 ft Section Leg Members Diagonal Members Horizontal Members 1-2 PX 50 ksi 16" DIAPIPE DAE 36 ksi 3.6X3.6X0.376 DAE 36 ksi 4X4XO.26 3 PX 60 ksi 14" DIA PIPE DAE 36 ksl 3.6X3.6XO.375 DAE 36 ksi 3.5X3.5XO.25 4 PX 60 ksi 12" DIAPIPE DAE 36 ksi 3.6X3.6XO.25 DAE 36 ksi 3.6X3.6XO.26 5 PX 60 ksi 12" DIAPIPE DAE 36 ksi 3.5X3.6XO.25 DAE 36 ksi 3X3XO.25 6 PX 50 ksi 10" DIAPIPE DAE 36 ksl 3X3XO.25 7 PX 50 ksi 10" DIAPIPE DAE 36 ksi 3X3XO.1875 8 PX 60 ksi 8" DIAPIPE SAE 36 ksl 4X4XO.375 9 PX 50 ksi 8" DIAPIPE SAE 36 ksi 3.6X3.SXO.375 10 PST 60 ksi 8" DIAPIPE SAE 36 ksi 3.6X3.SXO.25 11 PX 50 ksi 6" DIAPIPE SAE 36 lost 3X3XO.26 12 PX 50 ksi 6" DIAPIPE SAE 36 ksi 3X3XO.1876 13 PX 50 ksi 3-1/2" DIAPIPE SAE 36 ksi 2.6X2.5XO.1875 14 PST 60 ksi 3" DIAPIPE SAE 36 ksl 2X2XO.25 16 PST 50 ksi 2.1/2" DIAPIPE SAE 36 ksi 1.75X1.75XO.1876 SAE 36 ksi 1.76X1.75XO.1875 Discrete ADDurtenance 295.00 Panel 2 G56 Ax1'19iiU-2 295.00 Panel 4 CSS AXP18-80-2 295.00 Panel 3 CSS X7.666.4 295.00 Mounting Frame Flat Light Sector Frames 278.00 Whip 1 MSW MSW5011-2 265.00 Panel 6 W' x 9" TrA 265.00 Panel 12 Scala APIS-8601090 265.00 Mounting Frame Flat Light Sector Frames 179.00 Panel 3 Mdrew SBNHH-1D65B 179.00 Panel 3 Raycap ASU9338TYP0l 179.OD Panel 6 CellMax CMArBDHH165201EO-8 179.00 Panel 3 Nokia FXFB 179.00 Panel 3 Nokia FRIG w/o S.S. 179.OD Panel 3 RFS A7MA.41412D-1A20 179.00 Mounting Frame 3 Round Sector Frames 170.D0 Mounting Frame 3 Round Sector Frames 170.00 Panel 3 Commscope TrMSAP-lXR 170.00 panel 3 Nokia FZHJ 170.00 panel 3 Ericsson RRUS 31 B25 170.00 Panel 3 Ericsson RRUS-11 800 MHz 170.00 Panel 9 RFS ACU-A20-N 170.00 Panel 3 RFS APXV9ERR18-C 155.OD panel 3 Kathrein 800 10764 K 165.00 Panel 6 Kathrein 800 10121 165.00 Panel 6 RFS ATM192012" 165.00 Panel 1 Raycap DC6d8-60-18-BF 165.00 Panel 6 Ericsson RRUS 11 (Band 12) (65 165.00 Panel 3 Kathreln 782 10264 155.00 Panel 6 Kathrein Scala 860 10026 155.00 Panel 6 RFS FDGW550413C-3 155.00 Mounting Frame 3 Flat Light Sector Frames 140.00 Dish 2 Andrew UHX6.59W 120.00 Dish 1 Andrew UHX6-59W 100.00 nl�h 1 Andrew UHX6-69W From To City Description 10.000 300.00 1 Climbing Ladder 10.000 295.00 1 Waveguide 10.000 295.00 12 1 618" Coax 10.000 278.00 1 1/2" Coax 10.000 265.00 1 Waveguide 3D3.OD S=ct 15 280.D3 Sact 14 2&3.6D Seat 13 243.DD Sa:t 12 22D.DD Sect 11 Z".00 Sect 10 180.DD Sect 9 1&D.00 Sa-t 8 14D.00 Sact 7 120.00 Sact 0 f0D.00 Sact 5 6D.03 Sect 4 0.00 Sact 3 40.03 Sact 2 2D.00 Sa-t 1 02007-2015byA7CIPLLC. AIinghtsmsemed. Tower: 6100 Location: Midway Road, FL Code: ANSIITIA-222-G Shape :Triangle Base Width : 36.00 ft Client: T-MOBILE Top Width : 6.00 ft 10.00D 265.00 12 1 518" Coax 10.00D 179.00 1 Waveguitle 10.000 179.00 12 1 518" Coax 0.000 179.00 3 1.24" Hybrid 10.000 170.00 1 Waveguitle 10.000 170.00 3 1 1I4" HybriOex 10.000 170.00 1 0.87" Fiber 10.000 166.00 12 1618" Coax 0.000 165.00 1 Waveguitle 0.000 166.00 1 3/8" Coax 0.000 155.00 2 0.76"(19.2 mm) 8 AW 0.000 165.00 1 0.39" Cable 10.000 140.00 4 EW52 10.000 120.00 2 EW62 i Site Number: 5100 Code: ANSIrrIA-222-G 02007-2015byAMIPLLC. Alldghtsresemed. Site Nam e: Midway Road, FL Engineering Number: 63511322 913120156:05:42 PM Customer: T-MOBILE Location: Code: Shape: Tower Manufacturer: Tower Type: Saint Lucie County, FL ANSIITIA-222-G Triangle Sabre Self Support Analysis Parameters Height (ft): Base Elevation (ft): Bottom Face Width (ft): Top Face Width (ft): 300 0.00 36.00 6.00 Ice & Wind Parameters Structure Class: II Design Windspeed Without Ice: 123 mph Exposure Category: B Design Windspeed With Ice: 0 mph Topographic Category: 1 Operational Windspeed: 60 mph Crest Height: 0.0 ft Design Ice Thickness: 0.00 in Seismic Parameters Analysis Method: Equivalent Modal Analysis &Equivalent Lateral Force Methods Site Class: D - Stiff Soil Period Based on Rayleigh Method (sec): 0.82 T,(sec): a p: 1.3 Cs: 0.030 Ss: 0.056 S': 0.029 Cs' Max: 0.030 F.: 1.600 Fv: 2.400 Cs, Min: 0.030 Se, : 0.060 Say: 0.046 Load Cases 1.213+ 1.6W Normal 123 mph Normal to Face with No Ice 1.213+1.6W 60 deg 123 mph 60 degree with No Ice 1.213+1.6W 90 deg 123 mph 9p degree with No Ice 0.9D+ 1.6W Normal 123 mph Normal to Face with No Ice (Reduced DL) 0.91)+ 1.6W 60 deg 123 mph 60 deg with No Ice (Reduced DL) 0.913+1.6W 90 deg 123 mph 90 deg with No Ice (Reduced DL) 1.21) + 1.0131 + 1.0W i Normal 0 mph Normal with 0.00 in Radial Ice 1.21)+1.ODi+1.0Wi 60 deg 0 mph 60 degree with 0.00 in Radial Ice 1.21)+1.01)i+1.0Wi 90 deg 0 mph 90 degree with 0.00 in Radial Ice (1.2+0.2Sds)•DL+ENormal Seismic Normal (1.2+0.2Sds)•DL+.E 60 deg. Se ism is 60 de gre e_ (1.2+0.2Sds)•DL+E90 deg Seismic 90 degree (0.9-0.2Sds)•DL+ENorma] Seismic (Reduced DL) Normal (0.9-0.2Sds)•DL+E60 deg Seismic (Reduced DL) 60 degree (0.9 - 0.2Sds) • DL + E90 deg Seismic (Reduced DL) 90 degree 1.013+1.OW Service Normal Serviceability-60 mph Wind Normal 1.013+1.OW Service 60 deg Serviceability- 60 mph Wind 60 degree 1.013+1.OW Service 90 deg Serviceability- 60 mph Wind 90 degree Page 1 V 0 M N N N N N N N N T V J J V W W W V 0 b W W S< UJ W b O W W W W W W Vl O Ol zzp�w O O O O O O O O C C C C 00 n m A W m y y y C. CA oam ":E `W dly G ''y �rX D m 0 �� S li 3 S V� x on W f OE Z O N n D N O N W W '.Ow o D2N0 o.m.�oc 'O' y ' o > p W W W WNW W> W W N A �CC s N W N W W O V s W V W A A D �4J �IJ GI V7 CG7 b. V7 W _ 0 > N W W O s WOW W W �10 W NA+NIGN000GO GD C� tONN>OOf000N W W �• A tJ fO fD C G C C C VI V V v S O m W N V A O W 99 V A A v9 tJ O G-�000000 � � S 0 0 0 0 0 0 0> 0 0 0 0 X C OD OO 0o QO V W O �I OO DD Co a O 0 0 0 0 0 0 0> 0 0 0 0 T Ci V Ol V V L1 O :-1 CO Do W O m V VOW V W O O W> (n W O ti n � O O O O O O O W O O O O Z 00000 C C NI0000 x > O O OOOOOO W OOOO eY�' O C 0 0 0 0 0 C O O G C W W W W A A A A A A A A W W W W NNN W AAAA � f) A AAi+V7 V7N CCJ 4O fnf CJ N N N N W W W W N N N N CT W> W W N J s s W f D W V v C O tOW W W WAWNW W W .r,. s s W s N f 0 W A s s W O N W O N V A N WTONI JfNO ONANW WNNWWWut J J JV V VJV V V V V V V IND tN0 tN0 in l7 C G O CC00 OOOOOOOOOOOOO C 0000 00 O O O C C CG Ol CD' �N oOhO O = nNEm •i M�O T OwTT 0A0N � CD M a s an =0 0 cKWW=a0y^(AWy m fVD N DN1mEimi dm�ya(ox *o �-0c N'mrnfWC0 mfWfWC0 mAT N—W mO_ .a >i39n5- a. a. >.S0, (1) M C) CO)3a x yti oXy�c 2O CCC2�xc ^*yWWo� C W W n �GCW>> fq `DVNjMp p oW��C 0 0 h0w oN WfW'mGG0 O=V Z _ N 0 N N W N y > W » G N f A C C C w 0 0 A p C) O (D S V s 0 V7 > N W W s W W W W W W W W V1 W W W W W W W W W W WNW W> W W N A a m W C yW W W s N A A O W O N W W W W O s s W W W N N O s N O N s s v O O W A O W O o o O s s 0 W to O V N A W 0 s N s J A s W WNW W O J s W V W A A D T W 4J tnl 4.f AO+IJ 4iN+V7N bO+4f NN TOlaO NCI 41-+tJ TG7O �10 bID CO � r W W W O O N O A A 0 0> O W O C>> N O> »> N W W O> W O W fT W A AAtn COO G)GI NNA CinCOC.t CIA ACOCC:.I W tnAst>tO Af CCC m0D S 000 W»N>O W O V O>N V V -+NOO W OO W W>00OON W W ,�,�• OCCIJNOACO C4000CGUC ACO COGGOIO AtJ IO IOGGbOCNI :-IJ vS O G O O F 4J G O G O f p V O N O O t! 1 O A 1 4 f 0 0 0 f O N O 6+ 0 0 0 O O O+ S O O O O O O O O O O O O O O O O O O O O O O O O O O s 0 0 0 0 O O O W W D1 C1 OO W C V W V QO CJ W W W W J W W W W W W W V W O V W W W O O O O O O O O O O N O N O O O O O O W O O O O O O O W O O Vt O O O y O s> s O O O O O O O O O O O O O O O O O O O O O O O O O O> O O O O %1 m m O O O N Ct in N V W W W WNW W N 67 N V J N O) G7 CO W V V N O V W W W n < m O O O O O O O O O O O O O O O O O O O O O O O O O O O O O W O 0 0 0 •O •O •00 •000000000000 n O C O C O C C C CC CC C W 0000 �Z > W O O O O O O O O O O O O O O O O O O O O O O O O O O O O O W O 0 0 0 Vie' O O O O O O O O O O O O O O O O G C O C C C C O C C G C C w CCC C N A T T T W v v v v W W W N N W A A A fWJ lI OW1 OWf OWi OWi OWI J v V W W O N A Ej f J .aWO .0 io OO V N J V J V v V T T T W N N N N N N N fNJ J V V OWi OWi OWf W W OO N IJ .. T W > > > > > A > > QmC V W W > OIO WANW NsWN N W"MWtTJssW W WJ �V W V N A s N N W> W O N N N J O O A V W V w N M W OO W A WNW W W N V W V W N N W W W W W s W W W W O W O W O W O A W V ""Mom ++f0.f osNJtNON> W W AAK)tn W W W MOAIN N>A> QOr N W Ns V W W W -1 3 3 a W m m o a T r Tj i Site Number: 5100 Code: ANSlfrIA-222-G 02007-20I5byATCIPLLC. Afldghrsmsewed. Site Name: Midway Road, FL Engineering Number: 63511322 9/3/20156:05:42 PM Customer: T-MOBILE Tower Loadin 179.0 Raycap 3 15 3.2 1.7 18.9 18.9 0.80 0.67 0.0 0.0 38.42 270 36 179.0 RFS ATMAA1412D- 3 13 1.0 1.0 10.0 4.0 0.80 0.50 0.0 0.0 38.42 63 32 179.0 Round Sector 3 300 14A 0.0 0.0 0.0 0.75 0.75 0.0 0.0 3SA2 1270 729 170.0 Commscope 3 33 7.0 5.3 12.0 5.0 0.80 0.75 0.0 0.0 37.86 646 79 170.0 Ericsson RRUS 31 3 56 1.6 1.4 11.8 9.3 0.80 0.50 0.0 0.0 37.86 100 136 170.0 Ericsson RRUS-11 3 54 2.5 1.4 17.8 9.2 0.80 0.67 0.0 0.0 37.86 209 131 170.0 Nokia FZHJ 3 55 1.3 0.7 17.4 14.0 0.80 0.50 0.0 0.0 37.86 78 134 170.0 RFS ACU-A20-N 9 1 0.1 0.3 2.0 3.5 0.80 0.50 0.0 0.0 37.86 26 7 170.0 RFS APXV9ERR18-C 3 50 8.0 6.0 11.8 7.0 0.80 0.83 0.0 0.0 37.86 823 122 170.0 Round Sector 3 300 14.4 0.0 0.0 0.0 0.75 0.75 0.0 0.0 37.86 1251 729 155.0 Ericsson RRUS 11 6 55 2.5 1.5 17.0 7.2 0.80 0.67 0.0 0.0 36.87 406 267 155.0 Flat Light Sector 3 400 17.9 0.0 0.0 0.0 0.75 0.67 0.0 0.0 36.87 1353 972 155.0 Kathrein 782 10254 3 3 0.1 0.4 3.0 1.7 0.80 0.50 0.0 0.0 36.87 8 7 155.0 Kathrein 800 10121 6 46 5.2 4.5 10.3 5.9 0.80 0.82 0.0 0.0 36.87 1018 225 155.0 Kathrein 800 10764 K 3 41 5.9 4.6 11.8 6.0 0.80 0.79 0.0 0.0 36.87 558 99 155.0 Kathrein Scala 860 6 1 0.2 0.6 2.4 2.0 0.80 0.50 0.0 0.0 36.87 22 6 155.0 Raycap DC6-48-60- 1 20 1.1 2.0 11.0 11.0 0.80 0.50 0.0 0.0 36.87 22 16 155.0 RFS ATM1920126-0 6 11 1.0 0.8 11.5 6.0 0.80 0.60 0.0 0.0 36.87 116 53 155.0 RFS FDGW5504/3C-3 6 3 0.4 0.5 6.2 1.3 0.80 0.60 0.0 0.0 36.87 47 14 140.0 Andrew UHX6-59W 2 359 40.3 6.4 0.0 0.0 1.00 1.00 0.0 0.0 35.82 3923 582 120.0 Andrew UHX6-59W 1 359 40.3 6.4 0.0 0.0 1.00 1.00 0.0 0.0 34.27 1877 291 100.0 Andrew UHX6-59W 1 359 40.3 6.4 0.0 0.0 1.00 1.00 0.0 0.0 32.53 1782 291 Totals 129 9969 845.5 Discrete Appurtenance Properties 1.21)+1.013i+1.0wi Elevation Description Qty IceWt Ice EPA Length Width Depth K, Orient. Vert M� Q. F,(WL) P,(DL) (ft) (lb) (sf) (ft) (in) (in) Factor Ecc.(ft) (lb-ft) (psf) (lb) (lb) 295.0 CSS AXP18-80-2 4 19 4.8 5.8 6.7 4.1 0.80 0.85 0.0 0.0 0.00 0 111 295.0 GSS AXP19-60-2 2 15 4.9 5.8 6.7 4.1 0.80 0.85 0.0 0.0 0.00 0 43 295.0 CSS X7-665-4 3 27 8A 6.0 12.5 7.0 0.80 0.81 0.0 0.0 0.00 0 118 295.0 Flat Light Sector 3 400 17.9 0.0 0.0 0.0 0.75 0.75 0.0 0.0 0.00 0 1728 278.0 MSW MSW5011-2 1 25 3.1 13.0 0.0 0.0 1.00 1.00 6.5 0.0 0.00 0 36 265.0 14" x 9" TTA 6 10 1.0 1.2 9.0 6.0 0.80 0.50 0.0 0.0 0.00 0 86 ' 265.0 Flat Light Sector 3 400 17.9 0.0 0.0 0.0 0.75 0.75 0.0 0.0 0.00 0 1728 265.0 Scala AP15-8501090 12 27 10.6 8.5 10.0 4.0 0.80 0.77 0.0 0.0 0.00 0 463 179.0 Andrew SBNHH- 3 51 8.2 6.1 11.9 7.1 0.80 0.83 0.0 0.0 0.00 0 219 179.0 CellMax CMA- 6 62 9.1 5.4 15.9 5.0 0.80 0.70 0.0 0.0 0.00 0 536 179.0 Nokia FRIG w/o S.S. 3 54 2.3 1.5 15.2 6.0 0.80 0.67 0.0 0.0 0.00 0 233 179.0 Nokia FXFB 3 55 3.6 1.8 19.4 6.2. 0.80 0.67 0.0 0.0 0.00 0 238 179.0_Ravcap 3 15 3.2_ 1.7 18.9 18.9 0.80 0.67 0.0 0.0 0.00, 0 64 179.0 Round Sector 3 300 14A 0.0 0.0 0.0 0.75 0.75 0.0 0.0-0.00 -"'-01296 170A Commscope 1- - 33 U 3.3 12.0 5.0 0.80- 0.75 ---0-.0- :0.0---0.00- - --'0- 141 170.0 Ericsson RRUS 31 3 56 1.6 1 A 11.8 9.3 0.80 0.50 0.0 0.0 0.00 0 242 170.0 Ericsson RRUS-11 3 54 2.5 1.4 17.8 9.2 0.80 0.67 0.0 0.0 0.00 0 233 170.0 Nokia FZHJ 3 55 1.3 0.7 17.4 14.0 0.80 0.60 0.0 0.0 0.00 0 238 170.0 RFS ACU-A20-N 9 1 0.1 0.3 2.0 3.5 0.80 0.50 0.0 0.0 0.00 0 13 170.0 RFSAPXV9ERRIB-C 3 50 8.0 6.0 11.8 7.0 0.80 0.83 0.0 0.0 0.00 0 216 170.0 Round Sector 3 300 14A 0.0 0.0 0.0 0.75 0.75 0.0 0.0 0.00 0 1296 155.0 Ericsson RRUS 11 6 55 2.5 1.5 17.0 7.2 0.80 0.67 0.0 0.0 0.00 0 475 155.0 Flat Light Sector 3 400 17.9 0.0 0.0 0.0 0.75 0.67 0.0 0.0 0.00 0 1728 155.0 Kathrein 78210254 3 3 0.1 0.4 3.0 1.7 0.80 0.50 0.0 0.0 0.00 0 13 155.0 Kathrein 800 10121 6 46 5.2 4.5 10.3 5.9 0.80 0.82 0.0 0.0 0.00 0 400 155.0 Kathrein 800 10764 K 3 41 5.9 4.6 11.8 6.0 0.80 0.79 0.0 0.0 0.00 0 176 155.0 Kathrein Scala 860 6 1 0.2 0.6 2.4 2.0 0.80 0.50 0.0 0.0 0.00 0 10 Page 3 A TTONi V O NANNNNNNNNN V V V V V J V V V V V V V V fN0 tN0 fN0N d` ONAN NN O O O N N N N N N N N N O O O O O O O tO tO V7 fD fO VJ fD N N N Oo N N N N .vY' N O O O N N N oO CCCO ON 0mC O�O. ODf01 O OfT� CD O.io] OoNO0N OfC(OT O=NV1 DO ,op �O10 oOTG+ dOoCoEG o� S�0N7, tO'A1 OM 0. 1 > —,d0, �0 a^ <9acd dow 3 xL21 �tNA0D ?�007O• ?A.oO+ a7AOttr2��0oC a�N2Ntr2X0 oaaa n-OCddpn0o 0 0IL DD O io�tO WG 7N>00cf C � 70= "o-0 -0 2noom� np °22a>@pEWO rAO c_0.CY .a�W�2XttrL0o Zmj*cmmmm 0000bd ON C ' OO "Wo 0000 Z N N =O0 O 0 NpW Cl) N>OfcO V +N�+ cN+ wC�O Lo mm�G'D3�n-7I WAW S N W p � ID 1 _K (D W W W to W 0 N OOOO++ONNO V NAOIOiN iMA+W W Ni00oOJ+W V CDAA �D + A A A O OOOO+N N 4f to W A 0� tJ f0 N i {o N A O+ W N CI O A O N 0 W -� N bI t0 O L+ lO A t0 ho W W W W O N ca r + O W T O O N O A A 0 0> O W O O++ N O+++ N W O+ W O W N N x(O < N N OI O O N A. 0 fJN0 C•A fJI W OAON AA A4f CNOO W �1Oo+1 W NNA �G IJOOOOfL 3• n AAAN Gob O 000 AiiN30 W O V O+N V JiN00 W tONNi00t000NNOf � M• ...S 0000i++ GGG N Co C A fo tJ C G G G tb O A bo to O O O tO A iJ IO tO o o O o O fo LI:-1 OOON NO 0 O O O+ p+ N T N+ O V P.4 W A O$ 0 N O A G O N N N V A O O i O O 000 G10000fp V OIJOfT OtJ 4.f OGGIp tJGG-+OGGGOG.+.� � 000 W 00 0 0 0 W DD 0o Oo OD 0o Oo J Do V WNW W 00 W J QO W W a0 W OD OD J W O V O) W Ol ° O O O OD O) OD O O O O O O O O O O N O N O O O O O O N O O O O O O O N O O N O 0 0 O O O O O O tJN N C GGNIN tT tT V CDN inT V W NI GI <o V V NIOOO V Co V V NIG V Co bo W O 7y COGtT GN to O O O O O O O V7 N O V V N W O O V O N N O V V V O W J N 00N i N N 0 0 0 0 0 0 n G 00000000000000000000000000000rn0000 �Z o00000 •O 00000 000000000000 000000000000 fJ10000 x 000 C O + O O O O O O O O O O O p O 0 0 0 0 0 p O 0 0 0 0 0 0 0 0 0 W 0 0 0 0 Sew' 0 0 0 0 0 0 J wwmmwoo ao oo ao ao aom moo m�e ua uam mom moo �00000000o Np o00000 V L- fo J V %4 v J Ll J Ll V C C O O O C O LL L� N tJ N 11 in to fo IN A A N V V V V V V V V V+++++++ A A A A A A A w w W A N N N N o 0 0 0 0 0 CT OOJ Oo i W N OOimN +W +tO oo AAN W Noo OINN V AN+ .r. NtO W JJ W W W+++O W NANiN W tO tOONtO Oo W N W NJi JtOO o00000 i + W W J �� �� W NN++O)N NJ O WON mO OtOO W AOO Oo V NNOOf NOW W J N tON f O l O o o J W O J N W 10 0 0 0 0 f 0 0 N O D 0 o O f O N N N N N N O O N O N O J J J A N N t D i N 1 g 3 a 6n o 0_ a H W N Ni a u! a N N W Site Number: 5100 Site Name: Midway Road, FL Customer: T-MOBILE Linear Appurtenance Properties Code: ANSIrrIA-222-G Engineering Number: 63511322 Tower Loading ®2007-2015byATCIPLLC. Alinghtsmsemed.. 9/3/2015 6:05:42 PM Elev Elev . Out From To Width Weight Pct Spread On Bundling Cluster Of Spacing Orientation Ka •(ft) (ft) Description City (in) (lb/ft) In Block Faces Arrangement Dia (in) Zone (in) Factor Override 10.00 300.0 Climbing Ladder 1 1.00 4.00 0 Lin App Individual 0.00 N 1.00 1.00 0.00 10.00 295.0 1 5/8" Coax 12 1.98 0.82 33 1 Block 0.00 N 0.00 1.00 0.00 10.00 295.0 Waveguide 1 0.00 6.90 0 Lin App Individual 0.00 N 1.00 1.00 0.00 10.00 278.0 1/2" Coax 1 0.63 0.15 0 1 Individual 0.00 N 1.00 1.00 0.00 10.00 265.0 1 5/8" Coax 12 1.98 0.82 50 1 Block 0.00 N 0.00 1.00 0.00 10.00 265.0 Waveguide 1 2.00 6.90 0 Lin App Individual 0.00 N 1.00 1.00 0.00 0.00 179.0 1.24"Hybrid 3 1.25 1.05 67 Lin App Block 0.00 N 0.00 1.00 0.00 10.00 179.0 1 5/8" Coax 12 1.98 0.82 33 1 Block 0.00 N 0.00 1.00 0.00 10.00 179.0 Waveguide 1 2.00 6.90 0 Lin App Individual 0.00 N 1.00 1.00 0.00 10.00 170.0 0.87" Fiber 1 0.87 0.25 0 Lin App Individual 0.00 N 1.00 1.00 0.01 10.00 170.0 1 1/4" Hybr'rflex 3 1.54 1.00 0 Lin App Individual 0.00 N 1.00 1.00 0.00 10.00 170.0 Waveguide 1 2.00 6.90 0 Lin App Individual 0.00 N 1.00 1.00 0.00 0.00 155.0 0.39"Cable 1 0.39 0.06 0 Lin App Individual 0.00 N 1.00 1.00 0.01 0.00 155.0 0.76" (19.2 mm) 8 2 0.76 0.53 0 Lin App Individual 0.00 N 1.00 1.00 0.01 0.00 155.0 3/8"Coax 1 0.44 0.08 0 Lin App Individual 0.00 N 1.00 1.00 0.01 0.00 155.0 Waveguide 1 2.00 6.00 0 Lin App Individual 0.00 N 1.00 1.00 0.00 10.00 155.0 1 518" Coax 12 1.98 0.82 50 3 Block 0.00 N 0.00 1.00 0.00 10.00 140.0 EW52 4 0.00 0.59 0 Lin App Individual 0.00 N 1.00 1.00 0.00 10.00 120.0 EW52 2 2.25 0.59 0 Lin App Individual 0.00 N 1.00 1.00 0.00 10.00 100.0 EW52 2 0.00 0.59 0 Lin App Individual 0.00 N 1.00 1.00 0.00 Page 5 Site Number: 5100 Code: ANSIITIA-222.G 02007-2015byATCIPLLC. Alldghtsre ewed. Site Name: Midway Road, FL Engineering Number: 63511322 913/20156:05:42 PM Customer: T-MOBILE Force/Stress Summary Section: 1 Section 1 Bot Elev (ft): 0.00 Height (ft): 20.000 Shear Bear Pu Len Bracing % Py Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z Ia1R (ksi) (kip) Bolts Holes (kip) (kip) % Controls - LEG PX-16"DIAPIPE -719.54 1.2D + 1.6W 20.04 25 25 25 11.0 50.0 1,083.9 0 0 0.00 0.00 66 MemberX HORIZ DAE-4X4X0.25 -26.56 1.2D + 1.6W 90 16.92 50 50 50139.8 35.7 44.85 0 0 0.00 0.00 59 MemberY DIAG DAE-3.SX3.5X0.375 -43.451.2D+1.6W 90 26.91 23 43 23138.3 36.0 58.69 0 0 0.00 0.00 74 Member Shear Bear Pu Fy Fu Phit Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) ' ova Controls LEG PX- 16"DIA PIPE 591.89 0.9D+1.6W 60 50 65 1,093.5 0 0 0.00 0.00 54 Member HORIZ DAE-4X4X0.25 27.93 1.2D+1.6W90 36 58 125.71 0 0 0.00 0.00 22 Mender DIAG DAE-3.5X3.5X0.375 40.69 1.2D+1.6W 90 36 58 161.03 0 0 0.00 0.00 25 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (kip) % Bolts Bolt Type Top Tension 589.49 0.9D+1.6W 60 0.00 0 0 Top Compression 716.78 1.2D+1.6W 0.00 0 Bot Tension 645.77 0.9D+1.6W 60 1558.92 41 12 2"A572 GR. 50 Bot Compression 782.12 1.2D+1.6W 0.00 0 Section: 2 Section 2 Bot Elev (ft): 20.00 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-16"DIAPIPE -651.87 1.2D + 1.6W 20.04 25 25 25 11.0 50.0 1,083.9 0 0 0.00 0.00 60 MerrberX HORIZ DAE-4X4X0.25 -26.64 1.2D + 1.6W 90 15.85 50 50 50131.0 35.7 50.92 0 0 0.00 0.00 52 MerrberY DIAG DAE-3.5X3.5X0.375 -46.371.2D+1.6W 90 26.21 23 43 23134.7 36.0 61.88 0 0 0.00 0.00 74 MenberY Max Tension Member Pu (kip) Load Case Fy (ksi) Fu (ksi) Phil Pn Num Num (kip) Bolts Holes Shear phiRnv (kip) Bear phiRn (kip) Use % Controls LEG PX - 16" DIA PIPE 538,35 0.9D + 1.6W 60 50 65 1,093.5 0 0 0.00 0.00 49 Member HORIZ DAE-4X4X0.25 27.55 1.2D+1.6W 90 36 58 125.71 0 0 0.00 0.00 21 Member DIAG DAE- 3.5X3.5X0.375 42.26 1.2D+ 1.6W 90 36 58 161.03 0 0 0.00 0.00 26 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (kip) % Bolts Bolt Type Top Tension 535.98 0.9D+1.6W 60 0.00 0 0 Top Compression 649.19 1.213+1.6W 0.00 0 Bot Te nsion 589.49 0.9D+1.6W 60 0.00 0 Bot Com press ion 716.78 1.2D+1.6W 0.00 0 Page 6 Site Number: 5100 Code: ANSIrrIA-222-G 82007-2015byATCIPLLC. Alirlghtsmserved. Site Name: Midw ay Road, FL Engineering Number: 63511322 9/3120156:05:42 PM Customer: T-MOBILE Force/Stress Summary Section: 3 Section 3 Bot Elev (ft): 40.00 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Com pression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX - 14" DIA PIPE -582.06 1.2D + 1.6W 20.04 25 25 25 12.6 50.0 943.03 . 0 0 0.00 0.00 61 Member X HORIZ DAE- 3.5X3.5X0.25 -25.70 1.2D + 1.6W 90 14.78 50 50 50 139.5 36.0 39.24 0 0 0.00 0.00 65 Member Y DIAG DAE-3.5X3.5X0.375 -46.03 1.2D + 1.6W 90 25.53 23 43 23131.2 36.0 65.05 0 0 0.00 0.00 70 Member Shear Bear Pu Fy Fu Phit Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-14"DIA PIPE 483.70 0.9D+1.6W 60 50 65 954.00 0 0 0.00 0.00 50 Member HORIZ DAE-3.5X3.5X0.25 26.03 1.2D+1.6W 90 36 58 109.51 0 0 0.00 0.00 23 Member DIAG DAE-3.5X3.5X0.375 42.62 1.2D+1.6W 90 36 58 161.03 0 0 0.00 0.00 26 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (Kip) % Bolts Bolt Type Top Tension 481.43 0.9D+1.6W 60 0.00 0 0 Top Compression 579.55 1.2D+1.6W 0.00 0 Bot Tension 535.98 0.9D+1.6W 60 0.00 0 Bot Com pression 649.19 1.2D+1.6W 0.00 0 Section: 4 Section 4 Bot Elev (ft): 60.00 Height (ft): 20.000 Shear Bear Pu Len Bracing% Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Main ber (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-12"DIAPIPE -512.68 1.2D + 1.6W 20.04 25 25 25 13.9 50.0 851.91 0 0 0.00 0.00 60 MemberX HORIZ DAE- 3.5X3.5X0.25 -24.13 0.9D + 1.6W 90 13.71 50 50 50 129.4 36.0 45.37 0 0 0.00 0.00 '53 Member Y DIAG DAE- 3.5X3.5X0.25 -45.01 1.2D + 1.6W 90 24.88 22 44 12 97.4 36.0 66.44 0 0 0.00 0.00 67 Member Y Shear Bear Pu Fy Fu Phit Pn Num Num phiRnv phiRn Use ,Controls Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) /o LEG PX- 12" DIA PIPE 427.86 0.9D+1.6W 60 50 65 864.00 0 0 0.00 0.00 49 Member HORIZ DAE-3.5X3.5X0.25 24.42 1.2D+1.6W 90 36 58 109.51 0 0 0.00 0.00 22 Member DIAG DAE-3.5X3.5X0.25 42.19 1.2D+1.6W 90 36 58 109.51 0 0 0.00 0.00 38 Member - --Pu - -phiRnt-Use-Num --- - Max Snl'ce Forces - --- ki oad£as Ki -- - -TopTe ision -' - - - - --425.73=0.9D+1:6W60 - 0.00` - - -0 -_- - 0- _ Top Compression 510.33 1.2D+1.6W 0.00 0 Bot Tension 481.43 0.9D+1.6W 60 0.00 0 Bot Compression 579.55 1.2D+1.6W 0.00 0 Page 7 Site Number: 5100 Code: ANSUTIA-222.G 02007-2015byATC1PLLC. A1/rightsmsewed. Site Name: Midw ay Road, FL Engineering Number: 63511322 9/3120156:05:42 PM Customer: T-MOBILE Force/Stress Summary Section: 5 Section 5 Bot Elev (ft): 80.00 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX - 12" DIA PIPE -442.12 1.2D + 1.6W 20.04 25 25 25 13.9 50.0 851.91 0 0 0.00 0.00 51 Member X HORIZ DAE- 3X3X0.25 -23.10 1.2D + 1.6W 90 12.64 50 50 50 139.3 36.0 33.53 0 0 0.00 0.00 68 Member Y DIAG DAE- 3.5X3.SX0.25 -45.03 1.2D+ 1.6W 90 24.25 22 44 12 95.0 36.0 68.10 0 0 0.00 0.00 66 Member Y, Shear Bear Pu Fy Fu Phil Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) ova Controls LEG PX- 12" DIA PIPE 363.99 1.2D+1.6W 60 50 65 864.00 0 0 0.00 0.00 42 Member HORIZ DAE-3X3X0.25 22.79 1.2D+1.6W 90 36 58 93.31 0 0 0.00 0.00 24 Mernber DIAG DAE- 3.5X3.5X0.25 42.40 1.2D+ 1.6W 90 36 58 109.51 0 0 0.00 0.00 38 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (Kip) /o Bolts Bolt Type Top Tension 367.80 0.9D+1.6W 60 0.00 0 0 Top Compression 439.91 1.2D+1.6W 0.00 0 Bot Tension 425.73 0.9D+1.6W 60 0.00 0 Bot Com pre ssion 510.33 1.2D+1.6W 0.00 0 Section: 6 Section 6 Bot Elev (ft): 100.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX- 10" DIA PIPE -429.52 1.2D+1.6W 6.68 100 100 100 22.1 50.0 699.13 0 0 0.00 0.00 61 Member HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG DAE-3X3X0.25 -21.23 1.2D + 1.6W 90 25.80 47 47 23159.5 36.0 25.57 0 0 0.00 0.00 83 MemberY Shear Bear Pu Fy Fu Phit Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX- 10" DIA PIPE 356.92 1.2D+1.6W 60 50 65 724.50 0 0 0.00 0.00 49 Member HORIZ 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG DAE-3X3X0.25 20.83 1.2D+1.6W 90 36 58 93.31 0 0 0.00 0.00 22 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (KIP) % Bolts Bolt Type Top To nsion 314.98 0.9D+1.6W 60 0.00 0 0 Top Compression 374.35 1.2D+1.6W 0.00 0 Bot Tension 367.80 0AD+1.6W 60 0.00 0 Bot Com press ion 439.91 1.2D+1.6W 0.00 0 Page 8 Site Number: 5100 Code: ANSIITIA-222-G 02007-2015byATC1PLLC. Alinghlsmserved. Site Name: Midway Road, FL Engineering Number: 63511322 9/3/20156:05:42 PM Customer: T-MOBILE Force/Stress Summary Section: 7 Section 7 Bot Elev (ft): 120.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % F'y Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX - 10" DIA PIPE -364.90 1.2D + 1.6W 6.68 100 100 100 22.1 50.0 699.13 0 0 0.00 0.00 52 Member X HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG DAE-3X3X0.1875 -19.091.2D+ 1.6W 90 23.74 47 47 23146.7 36.0 22.90 0 0 0.00 0.00 83 Member Shear Bear Pu Fy Fu Phit Pn Num Num phlRnv phlRn Use Max Tension Member (kip) Load Case. (ksi) (ksi) (kip) Bolts Holes (kip) Controls (kip) LEG PX- 10" DIA PIPE 308.67 0.9D+1.6W 60 50 65 724.50 0 0 0.00 0.00 42 Member HOW 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG DAE-3X3X0.1875 18.94 1.213+1.6W 90 36 58 70.63 0 0 0.00 0.00 26 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (kip) /o Bolts Bolt Type Top Tension 262.95 0.9D+1.6W 60 0.00 0 0 Top Compression 311.96 1.20+1.6W 0.00 0 Bot Tension 314.98 0.9D+1.6W 60 0.00 0 Bot Compression 374.35 1.2D+1.6W 0.00 0 Section: 8 Section 8 Bot FJev (ft): 140.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % F'y Phic Pn Num Num phiRnvphiRn Use Max Com pression Mem bar (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX- 8" DIA PIPE -302.47 1.2D+1.6W 6.68 100 100 100 27.8 50.0 544.29 0 0 0.00 0.00 55 Member X HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG SAE-4X4X0.375 -16.87 1.2D + 1.6W 90 21.69 50 50 50165.2 36.0 23.68 0 0 0.00 0.00 71 MemberZ Shear Bear Pu Fy Fu Phit Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX - 8" DIA PIPE 256.46 0.9D+ 1.6W 60 50 65 576.00 0 0 0.00 0.00 44 Member HORIZ 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG SAE-4X4X0.375 16.79 1.2D+1.6W 90 36 58 92.66 0 0 0.00 0.00 18 Member -Pu--- phiRnt----Use-Num Max Splice Forces= (kip)=Load-Case _pup) gp]ts-=pogjype -Top Tens ion - 21610 0.9p+-1.6W60- 0:00 0 = 0Top Compression 253.74 1.2D+1.6W 0.00 0 Bot Tension 262.95 0.9D+1.6W 60 0.00 0 Bot Com pression 311.96 1.2D+1.6W 0.00 0 Page 9 Site Number: 5100 Code: ANSIrrIA-222.G 02007-2015byATCIPLLC. AOdghtsmserved. Site Name: Midway Road, FL Engineering Number: 63511322 913/20156:05:42 FM Customer: T-MOBILE Force/Stress Summary Section: 9 Section 9 Bot Bev (ft): 160.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % Py Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-8"DIAPIPE -245.511.213+1.6W 6.68 100 100 100 27.8 50.0 544.29 0 0 0.00 0.00 45 MemberX HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG SAE-3.5X3.5X0.375 -13.261.213+1.6W 90 19.66 50 50 50171.8 36.0 18.99 0 0 0.00 0.00 69 Member Shear Bear Pu Fy Fu Phit Pn Num Num PhlRnv phlRn Use M ax To nsion M am bar (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX- 8" DIA PIPE 207.70 1.213+1.6W 60 50 65 576.00 0 0 0.00 0.00 36 Member HORIZ 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG SAE -3SX3.5X0.375 13.15 1.21)+1.6W 90 36 58 80.35 0 0 0.00 0.00 16 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (KIP) /o Bolts Bolt Type Top Tension 175.65 0.91)+1.6W 60 0.00 0 0 Top Compression 203.74 1.213+1.6W 0.00 0 Sot Tension 216.10 0.913+1.6W 60 0.00 0 Sot Compression 253.74 1.213+1.6W 0.00 0 Section: 10 Section 10 Bot Elev (ft): 180.0 Height (ft): 20.000 Shear Bear Pu Len Bracing% Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PST - 8" DIA PIPE -196.43 11.213 + 1.6W 6.68 100 100 100 27.3 50.0 358.01 0 0 0.00 0.00 54 Member X HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG SAE- 3.5X3.5X0.25 -9.17 1.2D + 1.6W 90 17.66 50 50 50 152.7 34.8 16.37 0 0 0.00 0.00 56 Member Z Shear Bear Pu Fy Fu Phil Pn Num Num phlRnv phlRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) off" Controls LEG PST - 8" DIA PIPE 170.11 1.213+ 1.6W 60 50 65 378.00 0 0 0.00 0.00 45 Member HORIZ 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG SAE-3.5X3.5X0.25 9.03 1.213+1.6W 90 36 58 54.76 0 0 0.00 0.00 16 Member Pu phiRnt Use Num M ax Splice Forces (kip) Load Case (KIP) % Bolts Bolt Type Top Tens ion 143.34 0.913+1.6W 60 0.00 0 0 Top Compression 163.61 1.21)+1.6W 0.00 0 Bot Tension 175.65 0.913+1.6W 60 0.00 0 Bot Com press ion 203.74 1.21)+1.6W 0.00 0 Page 10 Site Number: 5100 Code: ANSIITIA-222-G 02007-2015byATCIPLLC. Alldghtsmsewed. Site Name: Midway Road, FL Engineering Number: 63511322 9/3/2015 6:05:42 PM Customer: T-MOBILE Force/Stress Summary Section: 11 Section 11 Bot Bev (ft): 200.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z IQIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-6"DIAPIPE -157.52 1.2D + 1.6W 6.68 100 100 100 36.5 50.0 342.89 0 0 0.00 0.00 45 MemberX HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 O.OD 0.00 0 D1AG SAE-3X3XO.25 -7.85 1.2D + 1.6W 90 15.70 50 50 50159.1 36.0 12.85 0 0 0.00 0.00 61 MemberZ Max Tension Mem bar LEG PX- 6" DIA PIPE HORIZ DIAG SAE-3X3XO.25 M ax Splice Forces Pu (kip) Load Case 137.47 1.2D+1.6W 60 0.00 7.77 1.2D+1.6W 90 Pu (kip) Load Case Shear Fy Fu Phit Pn Num Num phiRnv (ksi) (ksi) (kip) Bolts Holes (kip) 50 65 378.00 0 0 0.00 0 0 0.00 0 0 0.00 36 58 46.66 0 0 0.00 phiRnt Use Num (kip) % Bolts Bolt Type Bear phiRn Use (kip) % Controls 0.00 36 Member 0.00 0 0.00 16 Member Top Tension 110.42 0.9D+1.6W60 0.00 0 0 Top Compression 125.29 1.2D+1.6W 0.00 0 Bot Tension 143.34 0.9D+1.6W 60 0.00 0 Bot Com press ion 163.61 1.2D+1.6W 0.00 0 Section: 12 Section 12 . Bot Bev (ft): 220.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic On Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z td/R (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-5"DIAPIPE -119.041.213+1.6W 6.68 100 100 100 43.6 50.0 239.33 0 0 0.00 0.00 49 Member HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG SAE-3X3XO.1875 -7.02 1.2D + 1.6W 90 13.79 50 50 50138.8 36.0 12.78 0 0 0.00 0.00 54 Member - Shear Bear Pu Fy Fu Phil Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG- PX - 5" DIA PIPE 104.59 1.2D+ 1.6W 60 50 65 274.95 0 0 0.00 0.00 38 Member HORIZ 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG SAE-3X3X0.1875 6.93 1.2D+1.6W 90 36 58 35.32 0 0 0.00 0.00 19 Member -- Eu phiRhtUse-Num Splice Forces tkiol-Bolts -_ _Max _- - Bolt Tyne - - - - - - - - - --_Top-Tension --_ _76.58-0.9D+_1.6W=60-,-0.00-.---0-0-- -_----------------------_ Top Compression 86.94 1.2D+1.6W 0.00 0 Bot Tension 110.42 0.9D+1.6W60 0.00 0 Bot Compression 125.29 1.2D+1.6W 0.00 0 Page 11 Site Number: 5100 Code: ANSIrrIA-222-G 02007-2015hyATCIPLLC. Alinghtsmsemed Site Name: Midway Road, FL Engineering Number: 63511322 9/3/20156:05:42 PM Customer: T-MOBILE Force/Stress Summary Section: 13 Section 13 Bot Elev (ft): 240.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z Ia1R (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-3-1/2"DIA PIPE -82.321.213+1.6W 5.01 100 100 100 45.9 50.0 141.97 0 0 0.00 0.00 57 Member HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG SAE-2.SX2.5X9.1875 -5.731.213+1.6W 90 11.19 50 50 50135.7 36.0 11.06 0 0 0.00 0.00 51 Merrber Z, Shear Bear Pu Fy Fu Phit Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PX-3-1/2"DIA PIPE 72.91 0.91)+1.6W 60 50 65 165.60 0 0 0.00 0.00 44 Member HORIZ 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG SAE-2.5X2.5X0.1875 5.67 1.2D+1.6W 90 36 58 29.22 0 0 0.00 0.00 19 Member Pu phiRnt Use Num M ax Splice Forces (kip) Load Case (kip) /o Bolts Bolt Type Top Tension 41.14 0.9D+1.6W 60 0.00 0 0 Top Compression 47.81 1.2D+1.6W 0.00 0 Bot Tension 76.58 0.913+1.6W 60 0.00 0 Bot Com press ion 86.94 1.21)+1.6W 0.00 0 Section: 14 Section 14 - mod Bot Elev (ft): 260.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z KLIR (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PST - 3" DIA PIPE .42.48 1.2D+ 1;6W 5.01 100 100 100 51.8 50.0 82.46 0 0 0.00 0.00 51 Member X HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0 DIAG SAE-2X2X0.25 -5.291.213+1.6W 90 9.329 50 50 50143.2 36.0 10.36 1 1 12.43 17.40 51 MemberZ Shear Bear Pu Fy Fu Phit Pn Num Num phiftnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PST - 3" DIA PIPE 36.40 0.9D+ 1,6W 60 so 65 100.35 0 0 0.00 0.00 36 Member HOW 0.00 0 0 0.00 0 0 0.00 0.00 0 DIAG SAE- 2X2X0.25 5.24 1.213 + 1.6W 90 36 58 24.55 1 1 12.43 10." 50 Bolt Bear Pu phiRnt Use Num Max Splice Forces (kip) Load Case (kip) % Bolts Bolt Type Top Tension 16.89 0.9D+1.6W 60 0.00 0 Top Compression 19.77 1.2D+1.6W 0.00 0 Bot Tension 41.14 0.91)+1.6W 60 0.00 0 Bot Compression 47.81 1.21)+1.6W 0.00 0 Page 12 0 Site Number: 5100 Code: ANSIITIA-222-G 02007-2015hyATC1PLLC. Alinghtsmserved. Site Name: Midway Road, FL Engineering Number: 63511322 9/3/20156:05:42 PM Customer: T-MOBILE Force/Stress Summa Section: 15 Section 15 Bot E(ev (ft): 280.0 Height (ft): 20.000 Shear Bear Pu Len Bracing % Fy Phic Pn Num Num phiRnvphiRn Use Max Compression Member (kip) Load Case (ft) X Y Z Ia/R (ksi) (kip) Bolts Holes (kip) (kip) % Controls LEG PST - 2.1/2" DIA PIP .16.07 1.21)+ 1.6W 5.00 100 100 100 63.4 50.0 57.18 0 0 0.00 0.00 28 Member X HORIZ SAFE -1.75X1.75X0.18 -0.411.2D+1.6W 6.000 100100 100209.9 36.0 3.18 0 0 0.00 0.00 12 WmberZ DIAG SAE- 1.75X1.75X0.18 -2.86 1.20 + 1.6W 7.810 50 50 50 136.6 36.0 7.52 0 0 0.00 0.00 38 Member Z Shear Bear Pu Fy Fu Phil Pn Num Num phiRnv phiRn Use Max Tension Member (kip) Load Case (ksi) (ksi) (kip) Bolts Holes (kip) (kip) off" Controls LEG PST - 2-1/2" DIA PIP 13.82 0.913+ 1.6W 60 50 65 76.68 0 0 0.00 0.00 18 Member HORIZ SAE- 1.75X7.75X0.18 0.38 1.2D+1.6W 60 36 58 20.12 0 0 0.00 0.00 1 Member DIAG SAE-1.75X1.75X0.18 2.83 1.213+1.6W 90 36 58 20.12 0 0 0.00 0.00 14 Member Pu phiRnt Use Num Max Splice Forces (kip) Load Case (Kip) % Bolts Bolt Type Top Tension 0.00 0.00 0 0 Top Compression 0.25 (1.2+0.2Sds)• 0.00 0 Bot Tens ion 16.89 0.91)+1.6W 60 0.00 0 Bot Compression 19.77 1.21)+1.6W 0.00 0 Page 13