SUBMITTAL PACKAGE
I KOHLER POWER SYSTEMS POWER DEPOT INC 3553 NORTHWEST 78TH AVE / MIAMI, FL 33122-1134 ` P: 305-592-7i00 F: 305-592-1071 Quote: Proposal: ` SC BY �® St. Lucie COu(t4y 0026159800 THESE PLANS AND ALL RROPOS60 WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY MELD INSPECMRS THAT MAY BE NEC(•SCsA9IY IN ONO TO COMPLY WITH ALL APPLICABLE CODES. We are pleased to offer the following submittal for your consideration. Thank you, Denise Rackauskas, Power Depot 1. Voltage was changed to 120/240V, 1 phase (see page 4) Note: voltage change increased amperage to 521, therefore a 600Amp breaker was used in lieu of 250A breaker quoted (see pages 8-18). Also, due to voltage change the alternator was changed to 4T13X (see pages 24-26). 2. Enclosure rated for 150 mph & weather proof (see page 19) 3. Sound enclosure with enclosed critical silencer (see page 7). ❑x APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED NOT APPROVED REVIM Of THIS SHOP DRAWING IS UMNED TO ODNMRMANOE WITH THE DESIGN CONCEPT OFTHE PROIECTAND FOR COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT PLANS AND SPEOFICATIONS (INCLUDING SUPPIEMENTAL AND SPECIAL PROMSIONS), AND IS NOT INTENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED OR THAT ALL ITEMS'REOUIRED ARE SHOWN. BMW SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESIGN, DIMENSIONS, ROB CONDTITONS, CONSTRUCTION MEANSANO METHODS, COORDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENTS OF THE PLANS, SPEOFICATIONS OR CONTRACT. ANY NOTATIONS ON THIS SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED TO AUTHONDE ADD INONA - W ORK OR COST. REVIEW OF DESIGN CALNIAW)NS AND DRAWINGS PREPARED BY SPECIALTY ENGINEERS IS UNITED TO DESIGN INTENT AND DOES NOT CONSTITUTE A DETAILED CHEM OF CALOLIIATIONS, NOR DOES IT RELIEVE THE SPEOALTY ENGINEERS FROM THE RESPONSIBIM OF THE DETAILING OFTHE SPEOALTYCOMPONEMORSYSTEM. BY, H. 9-21-1 z ATKI N S DATE: 9-21-15 THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WIT THE PLANS AND SPECIFICATIONS BY IMECQ INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 KOHLER POWER SYSTEMS Quote Model 125REOZJG Spec Sheets Model KCS-AMTA-0260S Spec Sheets Alternator Data Sound Data Emissions Data Dimensional Drawings Wiring Schematic Diagrams Misc Subsection Alternator Data Sheet Sound Data Sheet Emissions Data EPA Certificate Generator Accessories Controller Enclosure Subbase Tank Transfer Switch Controller Schematic Diagram Controller Wiring Diagram Interconnection Diagram Remote Serial Annunciator Remote Serial Annunciator Transfer Switch Transfer Switch Literature 4T13X Sound Data Emissions Data EPA Certificate ADV-8182 ADV-7852 ADV-7935 ADV-7825 ADV-7881 ADV-8627 ADV-8041 GM79690 GM78246 ADV-6990 GM62554 GM93714 GM93715 Battery Charger ADV-5971 Battery Charger Assembly 233967 Block Heater 326220 Block Heater GM75536 Circuit Breaker GM85432 Emergency Stop A222654 Generator Heater GM79104 Warranty Warranty TP-5373 - -- -- - - - ---Warranty- TP=5374 - - - - - _ Warranty _ _ TP-5561 -- - arran - - - P_ - Pre -Startup Checklist THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS i;. AND GENERAL COMPLIANCE WITt THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR ISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 IS09001 Certificate Prototype Test Certificate Pre -Startup Checklist G15-152 G18-56 PreStartUpCheckList ®MVRDVED ❑ mumn ❑MP IDKWM ❑N AWi ED ATKI POWER DEPOT INC 3553 NORTHWEST 78TH AVE / MIAMI, FL 33122-1134 P:305-592-7100 F:305-592-1071 GENERATOR SET Job Name: Port St Lucie r4 Offer:K300825784 Version 4.0 Page 1 Model: 125REOZJG This generator set equipped with a 4T13 altemator operating at 1201 wits is rated for 125 kW/125 kVA. Ou u1 a ra e: 521 Configuration Qty, Description 2 125REOZJG Generator Set 2 125REOZJG, 12V, 60hz 2 Nameplate Rating, Standby 130 Degree 2 Decal, UL2200 Listing (Diesel) 2 Voita e 60 Lz 1Y20/240V 1 Ph 3W.1.0PF 2. Alternator & Mtg. 4T13X 2 Unit Mtd. Radiator Cooling 2 Skid & Mtg. 44" 2 Air Intake, Standard Duty 2 Controller, DEC3000 800A, 1Ph 2 Control & Harness, 125 JD D3K 2 S Enclosure Aluminum 2 Heater, Block, 120V, 1500w 2 Accessory Inner Panel 2 Breaker 1 Right Components 2 Generator Heater, 120/240V, 20OW 2 Run Relay, 12V 2 DEC3000 21npul/50utput 2 Neutral, 600A 4S - -2---- - -Decals,-Bonding &-Phasing- - — --- --_ _2- _ -Flexible Fuel Lines _ —Tank 24hr/48hr State�(Gonfig)` 2 Tank, 595 Gallon, State 2 7.5 Gal Spill Cont FDEP w/95% shutoff> 2 Containment Extension 2 High Fuel Switch FDEP, Tnk Hgt abv 31 in 2 Fuel Basin Sw, Top Mt, FDEP, TnkHgt 31 in 2 Tank, State Beams 2 Fuel Basin Sw, Tap Mt, FDEP, TnkHgt 31 in 2 Skid Extension 2 Coolant in Genset 6 gals. KOHLEVOWER SYSTEMS THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENES. AND GENERAL COMPLIANCE WIT THE PLANS AND SPECIFICATION: BY IMECO, INC. THIS STAMP DOE. NOT CONSTITUTE APPROVAL NO] DISAPPROVAL OF SAID DRAWING, DATED ON: 10-05-2015 ❑X APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED ❑ NOT APPROVED REVIEW OF THIS SHOP DRAWING 15 LIMITED TO CONFORMANCE W THE DESIGN CONCEPT OF THE PROJECr AND FOR COMPLIANCE WITH' INFORMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICATI( (INCLUDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND IS F INTENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED THAT ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT REUI THE CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESK DIMENSIONS, JOB CONDITIONS, CONSTRUCTION MEANS AND METRO COORDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMEI OF THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NOTATIONS THIS SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED AUTHORIZE ADDITIONALWORK OR COST. REVIEW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED SPECIALTY ENGINEERS IS UMITED TO DESIGN INTENT AND DOES F CONSTITUTE A DETAILED CHECK OF CALCULATIONS, NOR DOES RELIEVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF " DETAIUNG OFTHESPECLALTY COMPONENT OR SYSTEM. — By.--- H.Sanchez- -- A - nAT - --9-21-15 -ATIO N C POWER DEPOT INC 3553 NORTHWEST 78TH AVE / MIAMI, FL 33122-1134 P:305-592-7100 F:305-592-1071 2 Remote Emergency Stop Switch 2 Lit Kit, General Maint, 125REOZJG 2 Warranty, 5 Year Comprehensive 2 Warranty, 1 Year Standby 2 RSA III, Annunciator only 2 016 B11660M LIGP E /M'cro Ll, 0°4 2 Additional Shipping Charges Accepted 2 Mtg, LCB, LG-Frame, 600A, 4S 2 Covers, 4S J-Box LG-Frame LCB 2 Decal, NFPA 704 ID & Safe Fill Hgt 2 Battery Charger,Floatw/Alarms,12V-1OA Job Name: Port St Lucie r4 Offer:K300825784 Version 4.0 Page 2 a US h" AUTOMATIC TRANSFER SWITCH 3 Pole, 4 Wire, Solid Neutral, 0260 Amps, Kohler Standard rated Standard automatic transfer switch, Model KCS-AMTA-0260S, rated 480V, 60 Hz, complete with all standard equipment and housed in a NEMA Type 1 enclosure. THESE SHOP DRAWINGS WERE ' Configuration Qty Description REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WITF THE PLANS AND SPECIFICATIONS ' 2 KCS-AMTA-0260S BY IIV ECO, INC. TIUS STAMP DOES 2 Warranty - ATS, 5 Year Comprehensive NOT CONSTITUTE APPROVAL NOR ISAPPROVAL OF SAID DRAWINGS 2 Warranty, 1 Year Standard DATED ON: 10-05-2015 2 Lit Kit, ATS Production, KCS/KCP/KCC ❑X APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED ❑ NOTAPPROVED REVIEW OF THIS SHOP DRAWING IS LIMITED TO CONFORMANCE Y THE DESIGN CONCEPT OF THE PROJECTAND FOR COMPLIANCE WITH INFORMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICATI (INCLUDING SUPPLEMENTAL AND SPECIAL PROV610NSY-AND IS INTENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRE )RDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENT: THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NOTATIONS Of S SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED T( [HORIZE ADDITIONAL WORK OR COST. 'IEW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED EY CLALTY ENGINEERS IS LIMITED TO DESIGN INTENT AND DOES No 'LSTTME A DETAILED CHECK OF CALCULATIONS, NOR DOES I ]EVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF THI 'AILING OFTHE SPECIALTY COMPONENT OR SYSTEM. H. 9-21-1z TE: -21-15 ATKI NS KOHLER.POWER SYSTEMS KOHLER POWER SYSTEMS ❑X APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED ❑ NOT APPROVED REVIEW OF THIS SHOP DRAWING IS LIMITED TO CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND FOR COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICATIONS (INCLUDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND IS NOT INTENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED OR THAT ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESIGN, DIMENSIONS, JOB CONDITIONS, CONSTRUCTION MEANS AND METHODS, COORDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENTS OF THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NOTATIONS ON THIS SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED TO AUTHORIZE ADDITIONAL WORK OR COST. REVIEW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED BY SPECIALTY ENGINEERS IS LIMITED TO DESIGN INTENT AND DOES NOT CONSTITUTE A DETAILED CHECK OF CALCULATIONS, NOR DOES IT RELIEVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF THE DETAILING OF THE SPECIALTY COMPONENT OR SYSTEM. BY: H. 9-21-1 z nT K I N S DATE: 9-21-15 THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WIT THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 Model: 125REOZJG KOHLER. Power Systems 208-600 V Diesel 09001 Tier 3 EPA -Certified for 4pg�. Stationary Emergency Standard Features NATIONALLY YEGISTEREO Applications • Kohler Go. provides one -source responsibility for the Ratings Range generating system and accessories. • The generator set and its components are 60 Hz prototype -tested, factory -built, and production -tested. Standby: kW kVA 91-128 a The 60 Hz generator set offers a UL 2200 listing. 91-160 Prime: kW 84-116 a The generator set accepts rated load in one step. kVA 84-145 • The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. • A one-year limited warranty covers all generator set systems and components. Two- and five-year extended limited warranties are also available. • Alternator features: Qido. o Theunique Fast -Response® X excitation system delivers excellent voltage response and short-circuit capability using a rare-earth, permanent magnet (PM)-excded alternator. o The brushless, rotating -field alternator has broadrange reconnectability. • Otherfeatures: IL o Kohler designed controllers for guaranteed system THESE SHOP DRAWINGS WERE integration and remote communication. See Controllers on page 3. REVIEWED FOR COMPLETENESS GENERAL COMPLIANCE WIT The low coolant level shutdown prevents HE PLANS AND SPECIFICATIONS overheating (standard on radiator models only). JTAND Y HvIECO, INC. THIS STAMP DOES Integral vibration isolation eliminates the need for OT CONSTITUTE APPROVAL NOR under -unit vibration spring isolators. ISAPPROVAL OF SAID DRAWINGS Multiple circuit breaker configurations. Generator Set RatingDATED ON: 10-05-2015 Standby Rating Prime Rating ❑X APPROVED El RESUBMIT Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps ❑ APPROVED AS NOTED ❑NOT APPROVED 120/208 3 60 1241155 430 1141143 396 REVIEW OF THIS SHOP DRAWING IS LIMITED TO CONFORMANCE 127/220 3 60 125/156 410 114/143 374 THE DESIGN CONCEPT OFTHE PROJECTAND FORCOMPLIANCE WIT 120/240 3 60 124/165 373 114/143 343 INFORMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICA (INCLUDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND I! 4R12X 120/240 1 -60 91/91— -379-- -84/84 350 INTENDED 70 BE A VERIFICATION OF TOTAL MATERIAL REQUIRI 139/240 3 60 125/156 376 1141143 343 THAT ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT RI 277/480 3 60 1251156 188 114/143 171 347/600 3 60 125/156 150 1141143 137 120/208 3 60 128/160 444 116/145 402 127/220 3 60 128/160 420 116/145 381 1201240 3 60 128/160 385 1161145 349 4R13X 120/240 1 60 107/107 446 99/99 413 139/240 3 60 128/160 385 116/145 349 220/380 3 60 124/155 235 116/145 220 277/480 3 60 1281160 192 116/145 174 347/600 3 60 127/158 153 114/142 137 4TT 120 40 Q ® 25 521 114/114 475 Fa THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NOTATIONS Of S SHOP DRAWING MADE FLY ATKINS SHALL NOT BE CONSTRUED T( IHORIZE ADDITIONAL WORK OR COST. REW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED e CIALTY ENGINEERS IS LIMITED TO DESIGN INTENT AND ODES NO 4STTME A DETAILED CHECK OF CALCULATIONS, NOR DOES T ]EVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF TH -AILING OF THE SPECIALTY COMPONENT OR SYSTEM. H.Sanchez TE: 9-21-15 ^TKI N5 21-15 G5361 (125REOZJG) 31159 Alternator SpecificationsF0LE COPY Specifications Alternator • NEMA MG1, IEEE, and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Type 4-Pole, Rotating -Feld • Sustained short-circuit current of up to 300% of the rated Exciter type Brushless, Rare -Earth current for up to 10 seconds. Permanent -Ma net 9 Leads: quantity, type 4RX 4TX Voltage regulator Insulation: Material Temperature rise Bearing: quantity, type Coupling Amortisseur windings Voltage regulation, no-load to full -load One-step load acceptance Unbalanced load capability Peak motor starting kVA: 480 V 4R12X (12 lead) 480 V 4R13X (12 lead) 240 V 4T13X (4 lead) 12, Reconnectable 4, 120/240 Solid State, Volts/Hz NEMA MG1 Class H 130PC, Standby 1, Sealed • Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field. • Self -ventilated and dripproof construction. • Windings are vacuum -impregnated with epoxy varnish for dependability and long life. • Superior voltage waveform from a two-thirds pitch stator and Flexible Disc THESE SHOP DRAWINGS W Full 100% of Rating 100% of Rated Standby Curren (35%rip for wh 448 540 440 REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WITI- THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS El APPROVED ❑ RESUBMIT ❑APPROVEDASNOM ❑NOTAPPROvw x of TH5 SHOP DRAWING 5 NFRnED TO FDNFORMAN s UMMA AND SPEaAt PROWAGN51, AND 5 1 I BE A VENIfIUM. OF TO MARRUM REQUIRED :Ms REnuWN ARE 910WN. Rfl'IEW SHALL NOT REU DfM FROM THE NSONSRIIm OF DUMB OF DEB 1HE Puns, sPE�rcwTwxs oR mxrlucr. MW NDTAnoNS DATED ON: 10-05-2015 5 sxoP DRAwwG MADE Br ATvrS vuu xm BE EONWRuw Application Data Engine Engine Specifications Manufacturer John Deere Engine model 4045HF285 Engine type 4-Cycle, Turbocharged, Charge Air -Cooled Cylinder arrangement 4lnline Displacement, L (cu. in.) 4.5(276) Bore and stroke, min (in.) 106 x 127 (4.19 x 5.00) Compression ratio 19.0:1 Piston speed, m/min. (ft./min.) 457 (1500) Main bearings: quantity, type 5, Replaceable Insert Rated rpm 1800 Electrical NEW OF DEAGR WO VRONS AND DRAWINGS NUAAEO OXW ENGNEFRS IS UMNFD TO DEDGN OIIWf AND DOES h S A DETAUD OIEOB OF WOIu7DON5. NOR DOES RVE THE WEMW ENGWEFRS FROM n1E REPON RMr OF 1 R.aex 9-21-17-15 ATKINS Engine Electrical System Battery charging alternator. 12 Volt Ground (negative/positive) Negative Volts (DC) 12 Ampere rating 65 Starter motor rated voltage (DC) 12 Battery, recommended cold cranking amps (CCA): Quantity, CCA rating each One, 800 Battery voltage (DC) 12 Fuel Max. power at rated rpm, kWm (BHP) 147 (197) Cylinder head material Cast Iron Fuel System Crankshaft material Forged Steel Fuel supply line, min. ID, min (in.) 11.0 (0.44) Valve material: Fuel return line, min. ID, min (in.) 6.0 (0.25) Intake Chromium -Silicon Steel Max. lift, fuel pump: type, m (ft.) Mechanical, 1.8 (6.0) Exhaust Stainless Steel Max. fuel flow, Lph (gph) 90.0 (23.8) Governor. type,-make/model JDECElectronic L16 Max return line restribtion,kPa (in. Hg) 20(5.9) Denso HP3 Fuel prime pump - - Manual -Frequency regulation oload to fulNoatl - Isochicnrrs -- = Fr♦equency"regu Primary 30 Microns Frequency Fixed Secondary 2 Microns @ 98% Efficiency Air cleaner type, all models Dry Water Separator Yes Exhaust Exhaust System Exhaust manifold type Dry Exhaust flow at rated kW, ma/min. (cfm) 27.0 (953) Exhaust temperature at rated kW, dry exhaust, OC (OF) 580 (1076) Maximum allowable back pressure, kPa (in. Hg) 7.5 (2.2) Exhaust outlet size at engine hookup, mm (in.) 98 (3.86) Recommended fuel Lubrication #2 Diesel Lubricating System Type Full Pressure Oil pan rapacity, L (qt.) 13.0 (13.7) Oil pan rapacity with filter, L (qt.) 13.9 (14.7) Oil filter. quantity, type 1, Cartridge Oil cooler Water -Cooled G5361 (125REOZIG) 3115g Application Dat O LCI '1 O P ntrollers Cooling Radiator System Ambient temperature, oC ff)* 50(122) Engine jacket Water capacity, L (gal.) 8.5 (2.25) Radiator system capacity, including engine, L (gal.) 19.2 (5.1) Engine jacket water flow, Lion (gpm) 180 (48) Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.) 72 (4098) Heat rejected to air charge cooler at rated kW, dry exhaust, kW (Btu/min.) 26.5 (1508) Water pump type Centrifugal Fan diameter, including blades, mm (in.) 660 (26) Fan, kWm (HP) 7.7 (10.3) Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H2O) 0.125 (0.5) • Enclosure with enclosed silencer reduces ambient temperature capability by 5°C (91F). Snow package enclosure with enclosed silencer reduces ambient temperature capability by 1OoC (1 Ban. Operation Reauirements Air Requirements Radiator -cooled cooling air, ms/min. (scfm)$ 226.5 (8000) Combustion air, ms/min. (cfrn) 9.65 (341) Heat rejected to ambient air: Engine, kW (Btu/min.) 30.4 (1730) Alternator, kW (Btu/mtn.) 13.5 (770) $ Air density = 1.20 kg/m3 (0.075 Ibm/R3) Fuel Consumption Diesel, Lph (gph) at % load Standby Rating 100% 37.4 (9.9) 75% 29.0 VA 50% 21.1 (5.6) 25% 11.4 (3.0) Diesel, Lph (gph) at % load Prime Rating 100% 34.8 (9.2) 75% 26.9 (7.1) 50% 19.5 (5.1) 25% 10.6 (2.8) ❑X APPROVED ❑ RESUBMIT DESIGN CONCEPT OF THE PROJECFAND FOR COMPLIANCE WITH 1 ORMATION GIVEN IN THE CONTRACT PLANS AND SPECIHCATIC MUDING SUPPLEMENTAL AND SPECULL PROVISIONS), AND IS b ENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED W ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT REUI i CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESK TENSIONS, JOB CONDITIONS, CONSTRUCTION MEANS AND METHO )RDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMEI THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NOTATIONS S SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED rHOR17E ADDITIONAL WORK OR COST. IIEW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED CIN.TY ENGINEERS IS LIMITED TO DESIGN INTENT AND DOES B NSTITUTE A DETAILED CHECK OF CALCULATIONS, NOR DOES ]EVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF' H.Sanchez 9-21-15 ATKI N S 21-15 Decision -Maker 3000 Controller Provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility. • Digital display and menu control provide easy local data access • Measurements are selectable in metric or English units • Remote communication thru a PC via network or serial configuration • Controller supports Modbusm protocol • Integrated hybrid voltage regulator with x0.5% regulation • Built-in altemator thermal overload protection • NFPA 110 Level 1 capability Refer to G6-100 for additional controller features and accessories. Declslon-Maker' 550 Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities. • Digital display and keypad provide easy local data access • Measurements are selectable in metric or English units • Remote communication thru a PC via network or modem configuration • Controller supports Modbus© protocol • Integrated voltage regulator with x0.25% regulation • Built-in alternator thermal overload protection • NFPA 110 Level 1 capability Refer to G6-46 for additional controller features and accessories. Oa0-*M O Decision -Maker 6000 Paralleling Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities for paralleling multiple generator sets. • Paralleling capability With first -on logic, synchronizer, kW and kVAR load sharing, and protective relays • Digital display and keypad provide easy local data access • Measurements are selectable in -metric or English units -- - • Remote communication thru a PC via network or • Built-in alternator thermal overload protection • NFPA 110 Level 1 capability Refer to G6-107 for additional controller features and accesscries. Mmlbus• is a registered bedemadc of Sdmeider Secbia (125REOZ.G) 31159 THESE SHOP DRAWINGS WE REVIEWED FOR COMPLETED 4ND GENERAL COMPLIANCE' THE PLANS AND SPECIFICATI BY IMECO, INC. THIS STAMP E NOT CONSTITUTE APPROVAL )ISAPPROVAL OF SAID DRAW] DATED ON: 10-05-2015 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Standard Features • Alternator Protection • Battery Rack and Cables • Customer Connection (standard with Decision-Makerm 6000 controller only) • Local Emergency Stop Switch • Oil Drain Extension • Operation and Installation Literature Available Options Approvals and Listings ❑ California OSHPD Approval - ❑ CSAApprovai ❑ IBC Seismic Certification ® UL 2200 Listing Enclosed Unit ❑ Snow Enclosure (sound enclosure with enclosed critical silencer, intake hood, and electrical package) ED(S0-5Fdll'rrG�o`s'lu'fM`tiit!' ;o' dr .icaFis eax srY ❑ Weather Enclosure (with enclosed critical silencer) Open Unit ❑ Exhaust Silencer, Critical (kit: PA354809) ❑ Flexible Exhaust Connector, Stainless Steel Fuel System ® Flexible Fuel Lines ❑ Fuel Pressure Gauge ❑ Subbase Fuel Tanks Controller ❑ Common Failure Relay ❑ Communication Products and PC Software ❑ Customer Connection (Decision -Maker® 550 controller only) ❑ Decision -Maker© Paralleling System (DPS) (Decision -Maker® 6000 controller only) ❑ Dry Contact (isolated alarm) (Decision -Maker® 650 and 6000 controllers only) ❑ Input/Output Module (Decision -Maker• 3000 controller only) M) Remote Emergency Stop Switch ® Remote Serial Annunciator Panel ❑ Run Relay - Cooling System ❑ Radiator Duct Flange Electrical System Alternator Strip Heater ❑ Battery ® Battery Charger, Equalize/Float Type ❑ Battery Heater 19) line Circuit Breaker (NEMA type 1 enclosure) ❑ Line Circuit Breaker with Shunt Trip (NEMA type 1 enclosure) Paralleling System ❑ Manual Speed Adjust Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax Miscellaneous ❑ Air Cleaner, Heavy Duty ❑ Air Cleaner Restriction Indicator ❑ Certified Test Report ❑ Crankcase Emissions Canister ❑ Engine Fluids Added ❑ Rated Power Factor Testing ❑ Rodent Guards Literature General Maintenance ❑ NFPA 110 ❑ Overhaul ❑ Production Warranty ❑ 2-Year Basic Limited ❑ 5-Year Basic Limited ® 6-Year Comprehensive Limited Other Options © APPROVED ❑ RESUBMIT ❑ APPROVEDAS NOTED ❑NOTAPPROVED RORM OF Me. 1ARNNG 6 DMNED TO EcRaceM NCE VTII n1EDMGNEONOTOFT VR aMDMRMM%MNTFWlnln1E INFORMAVON GROW IN ENE mNIMET PutE AND GPEmRCAMIM NNUUMNG sDPNE avrT MO sKOAI PROWOMsL AND 5 NOG OGGFFIOED To EE A VERRICUUM OF TOJ MAI REQUIRED OR WE OON OFMSRFMO. E SHONIt REVIEW STARS OF Re1EVF nlE CONIPACFOII F0.0M TNF NFSPOFSIBRIIY OF DETNLS Oi OESIGN, 00.1ENS10N5, WOO EWER WtErnORANN MFAER MEMODs. OF ME UMM, SPEO NRO TRADES, O aft ANY Mrf REDNRFMS ON w 1NF N,ws, sPEo MN)E BY oft mN1RAR. r BE NOSIRUE ON A MIOPDRAWOIGMANE BYMANSLWl NOr RE COIbr0.11ED 10 REMGNOF DESNON CMATOEOfT. REhEJL oG NEaT1II . WEED, T AND oruT NT PD Dos BY NPOEMCONM r E A DoG E WEED, ro NFGEw WDNS AND DOE: xm ROMM GE A DETAREO OEVE OF W E RESP s, NOR DOES R REIEFVE ME SPEUNtt MGWEDt$ FROM WE REGPOtE1BNDY OF ME NETAnwc oF1NE9'FMLttOOMPONENTOR5Y5GFNt ey, ,.sand E DAATKINS TE: 421 -15 1 175 ice•!WN in Dimensions and Weights Overall Size, L x W x H, mm (in.): 2700 x 1120 x 1527 (106.3 x 44.1 x 60.1) Weight (radiator model), wet, kg Ob.): 1270 (2800) [ — W--1 I o o I L —►I NOTE This drawing is provided for reference ordy and shoWd clot t a Need for planning Installation. CdxRact y=local disc iWor for more detailed information. DISTRIBUTEDI HESE SHOP DRAWINGS WERE EVIEWED FOR COMPLETENESS ND GENERAL COMPLIANCE WIT HE PLANS AND SPECIFICATIONS Y I14ECO, INC. THIS STAMP DOES OT CONSTITUTE APPROVAL NOR SAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 C M111. 9019 9n1A X11AhvKnhlArC10 NJ nO 9 rasomo G5351 (125RE07JG) Nl5g - Industrial Generator Set Accessories KOHLER. Power Systems Line Circuit Breakers 15-2250 kW NGS WERE' a9001 THESE REVEWEDOFOR �C COMPLETENESS 4 ✓ is m— AND GENERAL COMPLIANCE WITF NATIONARY REGISTERED THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS N DATED ON: 10-05-2015 a I O Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kW Model Shown Dual Circuit Breaker Kit with Neutral Bus Bar 15-300 kW Model Shown Multiple Circuit Breaker Kits with Neutral Bus Bar 350-2250 kW Model Shown (also applies to some 300 kW models) Standard Features • The line circuit breaker interrupts the generator set output during a short circuit and protects the wiring when an overload occurs. Use the circuit breaker to manually disconnect the generator set from the load during generator set service. • Circuit breaker kits are mounted to the generator set and are provided with load -side lugs and neutral bus bar. • Kohler Co. offers a wide selection of molded -case line circuit breaker kits including single, dual, and multiple configurations for each generator set. • Four types of line circuit breakers are available: (see page 2 for definitions and pages 3 and 4 for application details) o Magnetic trip o Thermal magnetic trip O Electronic trip o Electronic with ground fault (LSIG) trip • In addition, line circuit breakers are offered with 80%D and 100% ratings. • Single line circuit breaker kits allow circuit protection of the entire electrical system load. • Dual line circuit breaker kits allow circuit protection of selected priority loads from the remaining electrical system load. • Multiple line circuit breaker kits with field connection barrier allow circuit protection for special applications (350-2250 W). • Line circuit breakers comDIV with the following codes o UL 489 Molded Case Circuit Breakers • UL 1077 Supplementary Protectors o UL 2200 Stationary Engine Generator Assemblies I9 APPROVED ❑ RESUDMR ❑ APPROVED AS NOTED ❑NU"PROVED NENM•Df Tx65xOP DMWI GMMA TD..PA .x IMwNMnox GrvFN Ix mE mx1M[T vP RxD NFCDunI IGftFMFNTPI µ0 SIE= iMxR90XSL µD 61 I.D.NIENDm RI BE 1 VEPRMNM OF TDELL MAINUL M OT P .E. xfMSPmUI. IE ExDWN. pE W 9MLL . Pm ME mtmMROP 1POM nlE 116PoNSIBIIIIY OF M. OF D61 6 DEH'JI Wm4M16 µ9 DMWDKS fABN® r ErmwRxs ¢ uwlm ro DEvcn Dlaerr AxD DGa x � A DETuIEn Oxa m GD]IYnDe¢. xm D06 mE srtauTr ExGmEExs EroM TxE WSPLW98vrt of 1 GBAe 5114h Paget ATKINS1 Line Circuit Breaker Types Magnetic Trip The magnetic trip features an electromagnet in series with the load contacts and a moveable armature to activate the trip mechanism. When a sudden and excessive current such as a short circuit occurs, the electromagnet attracts the armature resulting in an instantaneous trip (UL 1077 circuit breakers). Thermal Magnetic Trip Thermal magnetic trip contains a thermal portion with a bimetallic strip that reacts to the heat produced from the load current Excessive current causes it to bend suficienty to trip the mechanism. The trip delay is dependant on the duration and excess of the overload current Elements are factory - calibrated, A combination of both thermal and magnetic features allows a delayed trip on an overload and an instantaneous trip on a short circuit condition. Electronic Tri -51 These line circuit breakers use electronic controls and miniature current transformers to monitor electrical currents and trip when preset limits are exceeded. Electronic with Ground Fault Trip The ground fault trip feature is referred to as LSIG in this document. Models with LSIG compare current flow in phase and neutral lines, and trip when current unbalance exists. Ground fault trip units are an integral part of the circuit breaker and are not available as field -installable kits. The ground fault ❑ Alarm Switch pickup switch sets the current level at which the circuit breaker will trip after the ground fault delay. Ground fault pickup values are based on circuit breaker sensor plug only and not on the rating plug multiplier. Changing the rating plug multiplier has no effect on the ground fault pickup values. Most molded -case circuit breakers are 80% rated devices. An 80% rated circuit breaker can only be applied at 80% of its rating for continuous loads as defined by NFPA 70. Circuit conductors used with 80% rated circuit breakers are required to be rated for 100% of the circuit breaker's rating. The 80% rated circuit breakers are typically at a lower cost than the 100% rated circuit breaker but load growth is limited. 100% Rated Circuit Breaker Applications where all UL and NEC restrictions are met can use 100% rated circuit breakers where 100% rated circuits can carry 100% of the circuit breaker and conductor current rating. The 100% rated circuit breakers are typically at a higher cost than the 80% rated circuit breaker but have load growth possibilities. When applying 100% rated circuit breakers, comply with the various restrictions including UL Standard 489 and NEC Section 210. If any of the 100% rated circuit breaker restrictions are not met, the circuit breaker becomes an 80% rated circuit breaker. Line Circuit Breaker The alarm switch indicates that the circuit breaker is in a tripped position caused by an overload, short circuit, ground fault, the operation of the shunt trip, an undervoltage trip, or the push -to - trip pushbutton. The alarm resets when the circuit breaker is reset. ❑ Au)dliary Contacts These switches send a signal indicating whether the main circuit breaker contacts are in the open or closed position. ❑ Breaker Separators (350-2250 kW) Provides adequate clearance between breaker circuits. ❑ Bus Bars — - for connection to the generator set when circuit breakers are not ordered. 350-2250 kW. A bus bar kit is provided on the right side of the unit when no circuit breaker is ordered. Bus bars are also available in combination with circuit breakers or other bus bars on the opposite side of the junction box. On medium voltage (3.3 W and above) units, a bus bar kit is standard. ❑ Field Connection Barrier Provides installer wiring isolation from factory connections. ❑ Ground Fault Annunciation A relay contact for customer connection indicates a ground fault condition and is part of a ground fault alarm. ❑ Lockout Devil This field -installable manually operated c accommodate three in the OFF position I ❑ Neutral Lugs Various neutral lug E cable sizes for Conn ❑ Overcurrent' The overcurrentlril tripped due to over to the deenergized ❑ Shunt Trip, 1 p APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED ❑ NOT APPROVED EVIEW OODESI�F THIN IS SHOP DRAWING IS LIMITED TO CONFORMANCE WITH HL 1ARtbOVARRi@PffdWITH THE iI Cr PLANS AND SPEl NO FOR CIFICATIONS NC DING UPPyy NTAL AND SPECIAL '�RRQYLSII NHS), AND IS NOT I I)E@'A I#It OFTiI�`5tidL REQUIRED OR IWRIACP,aISN�RE(Til I aitRChrID07AI QWIEW SHALL NOT RELIEVE rdlookemndwMd ckitfTewipeeibbmakeETAILs OF DESIGN, ENSIONS, JOB CONDmONS, CONSTRUCTION MEANS AND METHODS, OORDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENTS F THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NomnouS ON HIS SHOP DRAWING MADE BY ATRINS SHALL NOT BE CONSTRUED TO W*tIzgeafl date multiple [MLDI LLIMWONS AND DRAWINGS PREPARED BY PECIALTY ENGINEERS IS LIM D TO DESIGN INTENT AND DOES NOT F CALCULATIONS, NOR DOES IT KI SPECIALTYE NGINECERSOFROM THE RESPONSIBILITY OF THE I\'1 Ashunt tripoptfomprovidesasolenoidwithin:the-circuit breaker- =_=. case that, when momentarily energized from a remote source, activates the trip mechanism. This feature allows the circuit breaker to be tripped by customer -selected faults such as alternator overload or overspeed. The circuit breaker must be reset locally after being tripped. Tripping has priority over manual or motor operator closing. ❑ Shunt Trip Wiring Connects the shunt trip to the generator set controller. ❑ Undervoltage Trip, 12 VDC or 24 VDC The undervobage tips the circuit breaker when the control voltage drops below the preset threshold of 350/.-70% of the rated voltage. G68B 5/14h Pag02 15-300 kW Line Circuit Breaker Gen. Set kW Alt Model Ampere Range Trip Type C. B. Frame Size 15-80 4D/4E/ 4P/4PX/ 4O14QX 30-100 Magnetic, UL 1077 E (480 V max.) Magnetic, UL 1077 with 12 V shunt trip Magnetic, UL 1077 with 24 V shunt trip 15-150 Thermal magnetic HD 60-150 Electronic U Electronic LSIG 175-250 Thermal magnetic JD 250 Electronic U Electronic LSIG 300-400 Thermal magnetic LA 60-200 4RX/4S/ 4SX/ 4TX/4V 30-100 Magnetic, UL 1077 E (480 V max.) Magnetic, UL 1077 with 12 V shunt trip Magnetic, UL 1077 with 24 V shunt trip 15-150 Thermal magnetic HD 60-150 Electronic U Electronic LSIG 175-250 Theme] magnetic JD 250 Electronic U Electronic LSIG 300-400 Thermal magnetic LA 400-606 LG LSIG 700-800 Thermal magnetic MG 1000-1200 Thermal magnetic PG 800-1200 Electronic U Electronic LSIG 200-900-' - 4M6226 - --- - 15-150 Thermal magnetic HD 60-150 Electronic LI Electronic LSIG 175-250 Theme] magnetic JD 250 Electronic U Electronic LSIG 300-400 Thermal magnetic --'LA- 400.600 Electronic LI —LG- -Electronic 700-800 Thermal magnetic MG 1000-1200 Thermal magnetic PG 800-1200 Electronic U Electronic LSIG Interrupting Ratings Circuit Breaker Frame Size 240 Volt, kA 480 Volt, kA 600 Volt, kA HD 25 18 14 JD LA 42 30 22 LG 65 35 18 MG PG Gen. Set kW Alt Model Ampere Range Trip Type C. B. Frame Size 15-80 4D/4E/ 4P/4PX/ 4Q/4OX 15-150 Thermal magnetic HD 60 150 Electronic LI Electronic LSIG 175-250 Thermal magnetic JD 250 Electronic LI Electronic LSIG 400 Electronic U LG Electronic LSIG 60-200 4RX(4S/ 4SX/ 4T)(/4V 15-150 Theme] magnetic HD 60-150 Electronic U Electronic LSIG 175-250 Thermal magnetic JD 250 Electronic LI Electronic LSIG 400 Electronic LI LG Electronic LSIG 6� 1200 Electronic LI PG Electronic LSIG 200- 4M6226 15-150 Thermal magnetic HD 60-150 Electronic U Electronic LSIG 175-250 Thermal magnetic JD 250 Electronic U Electronic LSIG 400 Electronic LI LG Electronic LSIG 600-1200 Electronic LI PG Electronic LSIG Circuit Breaker Lugs Per Phase (AI/Cu) Frame Size Ampere Range Wire Range E (480 V max.) 30 100 Up to two wire terminals fitting 1032 or 1/4-20 stud HD (80%) 15-150 One #14 to 3/0 HD (100%) 15-150 One #14 to 2/0 Cu only --Jp (80°�) 175 - --One4/Oto4/0 - -- 200-250 One 3/0 to 350 kcmil D`(100%) 75=250 One WO -to 300-kcmil Cu only LA 300-400 —One #1 to 600 kcmil or Two #1 to 250 kcmil LG 400-600 Two 210 to 500 kcmil MG 700-800 Three 3/0 to 500 kcmil PG 600-800 Three 3/0 to 500 kcmil 1000-1200 Four 310 to 500 kcmil 0 nvps ❑ mue ❑rsvxovm nsxaro 0hor.vvR0Vm oEsxu, axcuunoxc •xo muxxxa ruc wcmu� a uwrtx ro omcn wrznr um xm x G6M 5/14h Page ATKI KOHLER CO., Kohler, Wisconsin 53044 USAF, L E Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com n® PXhler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 15-300 kW Line Circuit Breaker Applications Single Circuit Breaker Installations Dual Circuit Breaker Installations A generator set with a single circuit breaker installed typically A generator set with dual circuit breakers installed is used to feeds a single transfer switch and then a distribution panel. separate critical loads. Typically, one circuit breaker will feed This allows protection of the entire system Line C.B. i 0 0 0 0 0 ATS Distribution Distribution Panel I Panel y To Remaining To Priority Load(s) Building Loads Single line circuit breaker configuration where circuit breaker can trip causing all power to building loads including priority load to be disrupted. Dual Circuit Breaker Combinations Alternator Model First C. B. Frame Size Second C. B. Frame Size Comments AII, except 4D/4E HD Standard or LSIG JD — LA — Standard only LG — Standard or LSIG 4D/4E HD Standard only 4D/4E HD - HD- -Standardonly - - -4P-/4PX/4G/ -4SX/4TX(4S/- aswarwavl 4UA HD HD - - -- D =HD orJD --C —HDo�JD—"Standardonly- LG HD orJD LG LG 4RX/4S/ 4SX/4TX/4V MG — Standard only PG — Standard or LSIG HD HD Standard only f JD HD or JD LA HD, JD, LA LG HD, JD, LA, or LG MG PG a main transfer switch with noncritical loads and the other circuit breaker will feed a second transfer switch that feeds critical or priority loads. First Second Line C.B. Line C.B. O I .0 9 4 O o o o O t Distribution Panel To Remaining To Priority Load(s) Building Loads Dual line circuit breaker configuration where first circuit breaker can trip allowing second circuit breaker to continue supplying power to priority load(s). Alternator Model First C. B. Frame size Second C. B. Frame Size Comments 4UA14MB226 _ MG Standard only PG Standard or LSIG HD HD JD HD or JD LA - HD, JD, or _LA. -__ Standard only - LG -HD; --JD, LA, HD, JD, LG (1 or 2 may ba_ ard-ouLSIG).— �MG==or-LG= pt,--d/oT-HD,-JD,-LG— may be LSIG PG PG PG Standard only HESE SHOP DRAWINGS WERE 'VIEWED FOR COMPLETENESS D GENERAL COMPLIANCE WITI- E PLANS AND SPECIFICATIONS IMECO, INC. THIS STAMP DOFS Availability is subject to change without notice. Kohler Co. resew NOT CONSTITUTE APPROVAL NOR right to change the design or specifications without notice and witho DISAPPROVAL OF SAID DRAWINGS obligation or liability whatsoever. Contact your local Kohler® genera DATED ON : 10-OS-2015 distributor for availability. APPROVED ❑ RESUBMn M OF TMS SNOP ORAMNNG S UMGEO TO WNF Bd6N CDNU7T OF 1HE PRORa AND FOR OOMm iRMMON GIVEN w THE mNIRACr PIAAS ANO IGaNG wPftFMFMAL AND sPEGAL PRGVOwN HOED TO BE A VMMA ON OF TOru MAI r ALLITEMSR Ue,wAREwO RMMM CONTUCIOR MOM THE RESPONSIBIM OF OE1, PDMMN Wmi OMM TR U, OR ANY R TIEP SPEOflOITFGS OR mNFRACE ANY SHOP OMWING MADE Or AICVS SMALL NOT M AND 6 L:L Ew OF OELGN W AATIOFS AND MMNNG,IPIIEPAREO OF �RATOFO, NOR n^'pG4I�yQEEFT¢�S�•'��•nD�.ymCn[[m narn ��.NO OoaN rrA157dEaS FROM TTN, RUPOtSIB.OF, G688 5,H4h Page 8 H.sa>chaA ATKINS &2,-,5 PowerPact"m H-, J-, and L-Frame Circuit Breakers General Information Section 2—General Information Table 3: 10 05/2012 IB THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS ND GENERAL COMPLIANCE WIT HE PLANS AND SPECIFICATIONMEY ICO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR ISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 The PowerPact H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. H- and J-frame circuit breakers are available with either thermal -magnetic or MicrologicTM electronic trip units. L-frame circuit breakers are available with Micrologic electronic trip unit. H- and J-frame circuit breakers with thermal -magnetic trip units contain individual thermal (overload) and instantaneous (short circuit) sensing elements in each pole. The amperage ratings of the thermal trip elements are calibrated at 104°F (40°C) free air ambient temperature. Per the National Electric Code® (NEC®) and the Canadian Electrical Code, standard circuit breakers may only be applied continuously at up to 80% of their rating. Circuit breakers rated for 100% operation are available but require specially -designed enclosures, copper lugs, and 194°F (90°C) rated wire. Devices with the Micrologic electronic trip unit provide adjustable protection settings for greater system flexibility. in addition to electronic protection, Micrologic trip units allow users to monitor both energy and power. Through direct access to in-depth information and networking using open protocols, PowerPact circuit breakers with Micrologic trip units let operators optimize the management of their electrical installations. Far more than a circuit breaker, these circuit breakers are a measurement and communication tool ready to meet energy -efficiency needs through optimized power requirements, increased energy availability, and improved installation management. Applications PowerPact H-, J-, and L-frame circuit breakers offer high performance and a wide range of interchangeable trip units to protect most applications. Electronic trip units provide highly accurate protection with wide setting ranges and can integrate measurement, metering and communication functions. They can be combined with the front display module (FDM121) to provide functions similar to a power meter. Applications PowerPact H-, J-, and L-frame circuit breakers equipped with Micrologic 516 hip units offer type A (ammeter) or E (energy) metering functions as well as communication capability. Using Meter Micrologic trip unit sensors and intelligence, PowerPact H-, J-, and L-frame circuit breakers provide access to measurements of all the main electrical parameters on the built-in screen, on a dedicated front display module (FDM121) or through the communication network. Integration of measurement functions provides operators with operating assistance functions ing assistance including alarms hipped by user -selected measurement values, time -stamped event tables and histories, and maintenance indicators. The main measurements can be read on the built -In screen of Micrologic 5 / 6 hip units. They lisplay module _ can also be displayed on the equipment FDM121 along with pop-up windows signalling the main. alarms. - - PowerPact H-; J-; and 1-4rame circuit breakers equipped with Micrologic 5 16 hip units provide •.631!3 ( r-a= _ © 2011-2012 Schneider Electric All Rights Reserved by Schneider Electric PowerPactTm H-, J-, and L-Frame Circuit Breakers General Information General Characteristics Faceplate Label Characteristics indicated on the faceplate label: A A. Circuit breaker type 's HD 150 -K-1 B Circuil Breaker B. Circuit breaker disconnector symbol 'ise C. Performance levels r', I I C D. Standards E. US: Operating voltage per IEC D F. Icu: Ultimate breaking capacity per IEC E G. Ifs: Service breaking capacity per IEC ' F H. Uimp: Rated impulse withstand voltage per IEC I. Ui: Insulation voltage per IEC G •� J. Certification marks 19 APPROVED ❑ RESUBMIT NOTE: When the circuit breaker is equipped with an extended ❑ "PROVED NOTED ❑ NOrAPPROVm EV¢WOM¢Ym oMwma¢uwnnro�rovwxxs vmm rotary handle, the door must be opened to view the faceplate. �i H xe ocvwom�mvrmmEVNE¢axx¢vu cvxwuxavmxnn � naMumx rave, w ra mmun vans um srteiumm xmmxe sumEwwru xw sNau vaanamat xxm TO rtmomeExweuwuu nrnmroru watMWiem Cx ev � wr uLsm¢xra¢m u¢sn¢nx RE�4W YWL xoremwF 0 J � xE awmua mm n¢ vuem¢imm m onau o 4Eun. wwvma.mem vrmEs m¢mumo�Mur¢xrmremmt ooearurm, wnx mxEF Hams, a un mxa uwmEEems v n1E vwa svEavemtm¢ w mmucr. un xmxma a � _ x¢sxmoRxvnxc eE m¢mum r¢ wewe=sxutxm :xo odes and Standards EMS ¢ mx,�x� �EP.Em m rcat1T w¢ rc avvEmwr um om xm .nxem aEm Ace m rw¢eMnmq xm xme n fLEl4 n1E YEOYIY EN6INEFRE iROM 1NE R®preBwEY 61NE nummmrasmaxETMms¢onExrEwYYExa -, J-, and L-frame circuit breakers, automatic switches and electronic motor circuit protectors are Y.N Sanrhaz /OTKI N S anufactured and tested in accordance with the following standards. Am --a, -15 OTE: Apply circuit breakers according to guidelines detailed in the National Electric Code (NEC) and other local wiring codes. Table 4: Codes and Standards (Domestic) PowerPact H-, J-, and L-Frame Circuit Breakers UL 4891 H-, J-, and L-Frame Switches UL 4893 IEC 60947-2 IEC 60947-3 GSA C22.2 No. 52 GSA C22.2 No. 54 Federal Specification W-C-37581GEN Federal Specification W-C-375131GEN _ - _NEMAAB7. _ __ NEMA ABI - - --- - :- NMX J-266 NMX J-266 cE-Marldng CEMarkina Pact H-, J-, and L-Frame Circuit Protectors CE Marking No. 14 t PowerPact H- and J-frame circuit breakers are in UL File E10027. PowerPact 1--frame circuit breakers are in UL File E63335. 2 PowerPact H- and J-frame circuit breakers are in GSA File LR40970. PowerPact L-frame circuit breakers are in GSA File 69561. 3 PowerPact H- and J-frame switches are in UL File E87159. 4 PowerPact H- and J-freme switches are in GSA File LR32390. © 2011-2012 Schneider Electric , _ All Rights Reserved by Schneider Electric THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WITI- THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 0512012 13 THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND COMPLIANC PowerPactTm H-, J-, and L-Frame Circuit Breakers THE DATED ON : 10-05-2015 GENEPLANA ND SPECIFICATITF NS General Information BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR Vibration ISAPPROVAL OF SAID DRAWINGS PowerPact H-, J-, and L-frame devices resist mechanical vibration. Il un �`- Tests are carried out in compliance with standard UL489 SA and SB for the levels required by siHn 1p1 merchant -marine inspection organizations (Veritas, Lloyd's, etc.): l Rio ��i PowerPact H-, J-, and L-frame circuit breaker meet IEC 60068-2-6 for vibration: — 2.0 to 25.0 Hz and amplitude +/- 1.6 mm — 25.0 to 100 Hz acceleration +/- 4.0 g Excessive vibration may cause tripping, breaks in connections or damage to mechanical parts. Electromagnetic disturbances PowerPact H-, J-, and L-frame devices are protected against: `-�-� overvoltages caused by circuit switching • overvoltages caused by an atmospheric disturbances or by a distribution -system outage (such as from failure due to lightning) • devices emitting radio waves (radios, walkie-talkies, radar, etc.) • electrostatic discharges produced directly by users PowerPact H-, J-, and L-frame devices have successfully passed the electromagnetic -compatibility, tests (EMC) defined by the following international standards: • IEC/EN 60947-2: Low -voltage switchgear and controlgear, part 2: Circuit breakers: — Annex F: Immunity tests for circuit breakers with electronic protection — Annex B: Immunity tests for residual current protection • IEC/EN 610004-2: Electrostatic -discharge immunity tests EN 61000-43: Radiated, radio -frequency, electromagnetic -field immunity tests ® APPROVED ❑ RESUBMITIE EN 61000-4-4: Electrical fast transient/burst immunity tests ❑APPROVED AS NOTED ❑NDTAPPROVED £VIEW OF THIS SHOP DRAN1NG IS umnED TO mNFORM)NOE Z4 fEN 610004-5: Surge immunity tests HEDESGNODNCFPGOFTIEPROKE ANDFOROOMPLMXTE YFORMATON GNQI M TIE OONI CT PLANS AND S`FCRIGII EN 6100046: Immunity tests for conducted disturbances induced by radio frequency fields NDJUDING SUPPLEMENTAL AND SPECNL PRO RUONST, AND IS NOT VIENDM TO BE A VFNFITATpN OF TOTAL MAIFNAL REEUIRECA PR 11: Limits and methods of measurement of electromagnetic disturbance characteristics of HE CON RAMS REQUIRED Y E SHOWN. REAM OF NMM NET BE strial, scientific and medical (ISM) radio -frequency equipment. IN WNRMCTOR FROM TIE OOITFISUMO OF ATTARS OF DE4r3N� AMENSroNy NIBC OTHEN;UNDO!, OR ANY MEANS ANO T�IODS, ests ensure that: IF THE ATON WRN OTHER TMO 0OR ANY OIHFA NOT IF THE PLANS, NFORGl10Ni OR CONIMR. ANY NOTAilONS ON SHOP DEMON MAOEBYANS AND DRANOT BECON4RUE�eI msance are re occurs IOP�AODRNINAL UMMD TONr. F W OF DESIGN GICUTATONS M'D OMWINGS PpfiAgF7t� ing times are respected ALTY ENGINEERS E UMRFD O DENGN ABO AND DDFN N ISME A OFTMlEO OIECN OF rein,U11pH5. NOR ODES R VE THE SPEOALTY MEMBERS FROM THE REGPOHNBI OF TIE NNGOFTIEN4OMtt[OMNxFMOR5Y51EM 1Ir l P•JIi79*inn _ BY: H.SBndrez TKU95 A DATE: 9-21-15 , ` tedals used in PowerPact circuit breakers will not support the growth of fungus and mold. - - -- -_ -- — - -- - PowerP-act,circuit-breakers:have-passed_the=test.derrned7below-for-extreme-atmosphedbcondifions — 14 Dry cold and dry heat: — IEC 68-2-1-dry cold at -55 eC — IEC 68-2-2-dry heat at +850 C Damp heat (tropicalization) — IEC 68-2-30-damp heat (temperature + 55' C and relative humidity of 95%D) — IEC 68-252 level 2-salt mist 05/2012 , _ © 2011-2012 Schneider Electdc All Rights Reserved by Schnelder Electric PowerPactTM H-, J-, and L-Frame Circuit Breakers General Information Special Ratings The H-frame and J-frame circuit breakers also comply with the following special ratings: • HACR rating • SWD switch duty rating (applies only to 15 and 20 A /277 Vac or less, 2P and 3P) • HID high intensity discharge lighting rating (15-50 A) THESE SHOP DRAWINGS WERE The L-frame circuit breakers complies with the following special rating: REVIEWED FOR COMPLETENESS • HACR rating [THE ND GENERAL COMPLIANCE WITF PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES Marine Ratings § NOT CONSTITUTE APPROVAL NOR ISAPPROVAL OF SAID DRAWINGS UL Marine Listed/CSA Certified Circuit Breakers (UL489 Supplement SA) IL DATED ON: 10-05-2015 The PowerPact H- and J-frame circuit breakers with thermal -magnetic trip units meet the UL 489 Supplement SA requirements for use on vessels of any length under or over 65 ft. (19.8 m). The PowerPact H-, J-, and L-frame circuit breakers with MicrologicTO electronic trip units meet the UL 489 Supplement SA for use on vessels over 65 ft. (19.8 m) in length. Marine circuit breakers must not use aluminum or aluminum alloys for terminal connections and must be calibrated at an ambient temperature of 104" F (40" C). Standard circuit breakers should not be specified or used in the place of marine rated circuit breakers. Circuit breakers can be ordered with the Marine SA listing by adding the suffixes "LC" (copper lugs) and "YA" (marine) to the catalog number. UL Naval Listed/CSA Certified Circuit Breakers (UL 489 Supplement SB) The PowerPact H-, J-, and L-frame circuit breakers with Micrologic trip units meet the UL 489 Supplement SB requirements for use on naval vessels. These circuit breakers are subject to various vibration tests as described in UL 489 Supplement SB. Naval circuit breakers must not use aluminum or aluminum alloys for terminal connections and must be calibrated at an ambient temperature of 122" F (50" C). Standard circuit breakers should not be specified or used in the place of navel rated circuit breakers. Circuit breakers can be ordered with the Naval SB listing by adding the suffixes "LC" (copper lugs) and "YA1" (naval) to the catalog number. American Bureau of Shipping (ASS) The PowerPact H-, J-, and L-Frame circuit breakers are certified to ABS-NVR (American Bureau of - al vessels. ❑x APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED ❑ NOTAPPROVED REVIEW OF I TS SHOP ING IS LIMITED TO CONFORMANCE THE DESIGN CONCEPT OF THEYROIECTAND OR COMPLIANCE ITWTHE USEGI 0 k-Io © 2011-2012 SchAl All Rights Reserved ENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED ,T ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT REW CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESU IENSIONS, JOB CONDITIONS. CONSTRUCnON MEANS AND METHO )RDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMEI THE PLANS, SPECIFICATIONS OR CONTRA[[ ANY NOTATIONS i SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED HORREADDITIONAL WORK OR COST. IEW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED CIALTY ENGINEERS IS LIMITED TO DESIGN INTENT AND DOES F LSTTTUTE A DETAILED CHECK OF CALCULATIONS, NOR DOES IEVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF' H.Sanchez 9-21-15 ITTKI NS 21-15 05/2012 15 by Schneider Electric Y PY F`�?- C ❑X APPROVED ❑ RESUBMIT owerPactTM H-, LJ-, and L-Frame Circuit Breaker: ❑APPROVED AS NOTED ❑NOT APPROVED General Informatiol EVIEW OF THIS SHOP DRAWING IS LIMITED TO CONFORMANCE WITH �OFF},THE PROJECT AND FOR COMPUANCE WITH THE HE DESIGN CONCEPRMAT 11111ONS TabltLUDIN��AIfFMTXi R`SPEOALPPROVISIONS), AND ISLANS AND nNOT Circ H-Frsme 250 A J-Frame 400 A L-Frame 600 A L-Frame CircuFROMTHERESPONSIBILITYDETAILS f% G HJ HL HR 3 JD JG JJ JL 2.3 JR 13 LD LG L. ILL JLR 13.4 LD LG W ILL JLR 13.4 Numl 016111111901IS,1011 CONDITIONS, CONSTRUCTION MEANS ND M Amp WITH OTHER TRADES, OR NY OTHER REQUI0. p 70-250 170400 200-600 75-L AUTHORIZEADDITIONAL COST. 125 5 110011251200125165 1100 1251200125 65 100 125 200REVIEW OF DESIGN giMTY ENGINEERS N 9PN5TINTE A DETAILSRELIEVE THE SPECIALTY S ND DRAWINGS PREPARE Id! IRIL ($ 5 g 0 65 y5 20 100 50 20 200 100 — 18 14 20 35 18 20 65 25 20 100 50 20 200 100 — 18 14 — 35 18 — 65 25 — 100 50 — M11005 0 200UL/C 100(kA — DETAIUNGOFTHESPEC QUMOIDIENT OR SYSTEM. —— — — —20 — — — — — — — jIEC Mchmultlbmfeas gs Is 9-21-1 220/240 Vjj 1 K I ilk 15 1100 1251150125165 100 125 150125 165 11001125 150125 65 110011251150 DATE[ Vill 5 65 100 125 18 35 65 100 125 18 35 65 100 125 18 35 65 100 125 UOim 65 100 125 18 35 65 100 125 18135165 100 125 18 35 65 100 125 (Icu) 500/525 Vac 14 18 25 50 75 14 18 25 50 75 14 18 25 50 75 14 18 25 50 754 (kA=a) 690 Vac — — — — 20 — — — — 20 — — — — 20 — — — — 20 250 Vdc2 — — — — — 20 20 20 20 — — — — — — — — — — 500 VdCZ 3 — — — — — 20 20 20 20 — — — — — — — — — — — Service breaking capacity (Ics) % Icu 100% 100% 100% 100% Insulation Voltage Vi 750 Vac 750 Vac 750 Vac 750 Vac Impulse Withstand Voltage Vim 8 kVac 8 kVac 8 Wac 8 Wac Operational Voltage Va 690 Vac 690 Vac 690 Vac 690 Vac Sensor Rating In 150 A 1250 A 1400 A 1600A Utilization Category — A JA JA JA Short-circuit protection Magneticonly • • • 10 10 1 • I Is ■ • 1 • 1 • In In In • ■ • • • Thermal -magnetic • • • In in in In • • In — — — — — — — — — — ElecOonic In In • • • • • • • • • • • • • Ovehod-cimuR protectionection with neutral protection(OB-0.SI-0SN)5 • III III I Is is I• • • • I Is III • Is III III• ■ with ground fault protection • • • Is 10 10 in In • • 10 In I • I • • with zone selective Interlocking(ZSI)a • • • • In I • I ■ ■ • • • • 10 In • • L • • Display / I, V, f, P, E. THD measurements / interrupted -current measurement ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' • ' ' Front display module (FDM121) • • • • • • • • • • • • • • • • Is • IN IN Operating assistance • • • • • • • • • • Options Counters ■ Is • • • • • • • • • Histories and alarms • Is • • • • • • • • • • • • • • • • • Metering Con • • • • • • • • • • • • • • Is • • • • • Device sta[us/oontml com • • • • • • • • • • •_ • •.- •- •_ ■_. • ■_ •— _ , Uunenstons / Weight / Connections DimeAsions3P -- - _ Height — _ _ _ _ _ 6.4(163) _ T511911 la-3fftX0) 34D) - -- - '- _ _ (Unit Mount) - Width- -- — --- - - — - 41 (1W_-_ -.- 4j_(104) --_ =iu: (mm} Depth 3,4(86) 3.4(86) 4.33 (110) 4.33 (110) Weight 3P -lb. (Kg) 4.8 (2.2) 5.3 (2.4) 132 (6.0) 13.7 (6.2) Connections / Terminations Unit Mount Is a ■ • Is Rear Connection Plug -In ■ • • • • • Drawout • • • Optional Lugs Is • ■ t H and J-fmme breakers with Micrologic" trip units available only with 3P. The HJ, HL and the J-Frame 2P breakers are 3P 2 DC not available with PowerPact H. J or L-frame circuit breakers with Micrologic hip units. 3 500 Vdc speck catalog numbers, ungrounded UPS systems only. 4 la for 600 A L-frame circuit breaker at 525 V Is 19 kA © 2011-2012 Schneider Electric All Rights Reserved FIT by Schneider El a cc.lc THESE SHOP DRAWINGS WE REVIEWED FOR COMPLETEI• AND GENERAL COMPLIANCE' THE PLANS AND SPECIFICAT. BY IMECO, INC. TUNS STAW C NOT CONSTITUTE APPROVAL DISAPPROVAL OF SAID DRAW] DATED ON: 10-05-2015 PowerPactTk^ H-, J-, and L-Frame Circuit Breakers FILEM PY CO General Information 5 OSN: Over Sized Neutral protection for neutrals carrying high currents (e.g. 3rd harmonics). B ZSI using restraint wires. PowerPact H-, J-, and L-frame Circuit Breaker Trip Units Table 7: MicrologicTm Trip Unit Features Features LI LSP Trip Unit (X = Standard Feature, O = Available Option Standard 3.213.3 1 3.2S13.3S X Ammeter Energy 5.2A15.3A I 6.2A16.3A I 52H5.3E I 6.2E16.3E X LSIG/Ground Fault Tdp2 Ground -Fault Alarm Trip X X X Current Settings Directly in Amperes True RMS Sensing X X UL Listed X X Thermal Imaging X X LED for Long -Time Pickup X X LED for Long -Time Alarm X X LED Green 'Ready" Indicator X X IJ]F "PROM ❑ RsuaMm Up to 12 Alarms Used Together ❑ APPPOME NOTED ❑ NOTAPPkDVEO Digital Ammeter Pfl'IiW Oi Trti SNOP DMWING li WITTED N ONIFORMANlf Wrll MFDF9GX WNOFrOiMEPRDIERNiDFOR rOTNWNa VI1TNT1! Zone -Selective lnteriocking3 INFORMATON GNEN W TIE QYmPACT M16 AMD $PEOFIGTDra xNwImIXG HIpgFA¢HrN' FIA fi/Fd1t mOlwOMj• AND 6 NOr Communications INTENDED T) BE A VaUFlGTON Cf TlrAl VATIML REpAPET OP MT. rams REawRmmlEsxw Pm00s NOrnravE LCD Display n,EmmR. FROm T¢ RrsP Nulr OF o ..O, M., O O wmEFbom,me �cmwls,oxamllcnoxmwnANomaxom, Front Display Module FDM121 mJfldNAMM WIIII'mus TWDEL OR A O'Nat NFONxFMEmS a n¢ nAra. sP NF mcm OR cwrcr r NOrATOm ON Advanced User Interface rNu'sNov DR.Rwws mAOE W ArrWs sxAu Nor NF awaraum m 7 "Ig"romOr'"c6O"�T Neutral Protection REVIEW OF DWON ONwu xs AND a.. P Pam BY SPEOAEtt ENGNUM w umnE ro OMMN INTENr um DOES NOT Contact Wear IndlcatloO [ YmVnl A MMUD OIEa OF WNE .T NOR Wf5 rt RDDVE rME ssErutt mwxrOa FRwn rF¢RESPomeNIYamF Incremental Fine Tuning 9 of Settings oEruWDOFTIEsvEDmttmmFoxurtwsnsox BY: H.Sandlaz Load Profile°, 5 - oATE: 321-15 ATKINS Power Measurement Power Quality Measurements 1 The LSI with 3.2S/3.3S trip units have f ced short time and long time delays. 2 Requires neutral current transformer on three-phase four -wire loads. 3 ZSI for 111,14rame devices is only IN. ZSI for L-frame devices is IN and OUT. 4 Indication available using the communication_ system only. - ' - 5 % of hours in 4 current ranges: 0-49%. 50-79%, e0-89%, and >90 % I, 16 0512012 THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENES; tND GENERAL COMPLIANCE WIT rHE PLANS AND SPECIFICATION'S 3Y Uv ECO, INC. THIS STAMP DOE: a.v vo u,tr crNrrnv VnL. DIS=APPROV�fS 6FSA-IT01UM Thermal -Magnetic or Electronic Trip Unit? DATED ON 10-05-2015 Thermal -magnetic trip units (available on H- and J-frame circuit breakers only) protect against overcurrents and short-circuits using tried and true techniques. For applications requiring installation optimization and energy efficiency, electronic trip units offering more advanced protection functions combined with measurements. Trip units using digital electronics are faster as well as more accurate. Wide setting ranges make installation upgrades easier. Designed with processing capabilities, Micrologic trip units can provide measurement information and device operating assistance. with this information, users can avoid or deal more effectively with disturbances and can play a more active role in system operation. They can manage the installation, anticipate events and plan any necessary servicing. © 2011-2012 Schneider Electric All Rights Reserved by Schneider Electric s e A MULTIPLES OF In MICROLOGICTR' ELECTRONIC TRIP UNITS onomm f•M■M���■■■MM■t♦�MY-- —En ■■nl��■■■■■■fie■■■■■■ milli Cm�mmlilCilllmmm®■omiill milllmm0�ml�milllmmmm®®®Cull �■■wMwww�Mw��■■�wwswr•M_w��■w ■o�osliiiii®o■�■o�nmo■�■:svo CiillCCia0a1lCi111C1®CiIC1oCi111 CCIi1CCimC1:Ci�CCilllCCri�®®Cilil �■■■tr0 Mwtt•■■tr M■Yw�■■■tl MEMO f 1 1 I ■ ■ 1 I m �� M■Em=NE ■tl wt•■■■M�■■� NONNIw■ ■■N■ wN■■■I■ 111111 WHO milli m.mmom illl milli '■SII � 111111E M■MY�0■■1 NUMEME ■■■■fib ■ wYw��■■n M■■■■■■■� Omni I�■wY■■■l■ milli ®■�ii:i:11 milli �ClaicBmQill = Ill milli ®��m■1■1 r•�u�w wr.Mw��■w M■M■■!•�■w NO■NI ■■■n waa■■■u ■■NN1 �B■■■�Imilli ®®�®�aa1C1�il�l', ■�m�lli� ■■0�0� ��t1■��1� goo - -ioYw4L■ta!■� �N■■1 __ ■willillil 011 gill10 �� ■� �Maiii■rrMo �iGi�YwYa��■■�wY ■■■n■�lllll■I■■■■■u® ■■nl■■ww■a■�m® q w n e w w,.wwe a .3 MULTIPLES OF In Micrologic' 3.3/3.3S/5.3A or E/6.3A or E Instantaneous Trip Curve 600A L-Frame ® The time -current curve information is to be used for application and coordination purposes only. Notes. 1. There is a thermal -imaging effect that can act to shorten the long-time delay. The thermal imaging effect comes into play if a current ;w above the long-time delay pickup value exists ®° for a time and then is cleared by the tripping of ® a downstream device or the circuit breaker .m itself. A subsequent overload will cause the ® circuit breaker to trip in a shorter time than normal. The amount of time delay reduction is 'm inverse to the amount of time that has elapsed since the previous overload. Approximately 20 minutes is required between overloads to ,>o completely reset thermal -imaging. 2. Total clearing times shown include the response times of the trip unit, the circuit m breaker opening, and the extinction of the current. ® 3. In = Maximum dial setting of In 600A L-Frame: In = 600A = Max IT setting Curves apply from -350C to +70°C (-31 OF to +1580F) ambient temperature. 16 s 8 M♦Mar.Mu :: wYo�Yn .. Schneider Electric ONI, bIMbBxdc YM1Tw rtad ❑X APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED ❑ NOT APPROVED EVIEW OF THIS SHOP DRAWING IS LIMITED TO CONFORMANCE WITH HE DESIGN CONCEPT OF THE PROJECTAND FOR COMPLIANCE WITH THE IFORMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICATIONS NCLUDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND IS NOT OENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED OR HAT ALL HEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT REUEVE HE CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESIGN, IMENSIONS, JOB CONDITIONS, CONSTRUCHON MEANS AND METHODS, DOMINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENTS P THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NOTATIONS ON HIS SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED TO UTHORIZE ADDITIONAL WORK OR COST. EVIEW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED BY PECUILTY ENGINEERS IS LIMITED TO DESIGN INTENT AND DOES NOT ONSTITUTE A DETAILED CHECK OF CALCULATIONS, NOR DOES IT ELIEVETHE SPECIALTY ENGINEERS FROMTHERESPONSIBILITY OF THE ETAIUNG OFTHE SPECIALTY COMPONENT OR SYSTEM. THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WIT THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 DeNg1L 61,d,•]&10 IyN W„ Industrial Generator Set Accessories KOHLER. Power Systems Weather/Sound Enclosure and Subbase Fuel Tank Package 09007 THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS 41RK. AND GENERAL COMPLIANCE WITF NATIONAUY REGISTERED THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 01 Ef -clo-a fre tivi# S#Pate (ZOde $ base K.UEIt Tan APPROVED ❑ RESUBMIT EW OF THIS SHOP DRAWING lS-UMTIED TO CONFORMANCE 1A DESIGN CONCEPT OF THE PROJECTAND FOR COMPLIANCE WITH IRMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICATII LUDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND IS I TJDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED T ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT REU LO<WUCIQELFRONSHERELONSIBUaY-MMETAILS OF DESI ❑ ULrR WITH OTHER TRADES, OR ANY OTHER REQUIREMEI ❑ G,S SPECIFICATIONS OR CONTRACT. ANY NOTATIONS WING MADE BY ATKINS SHALL NOT BE CONSTRUED ❑ IB0ftatLQWRK OR COST. ❑ CaSlr,App7wMTIONS AND DRAWINGS PREPARED ❑ CUIK%y D TO DESIGN INTENT AND ��tDOES P PINEi_�TAI 1 ECK OI�AI`C �O F��IL'TYDOFF'' By. H.Sanchez DATE: 9-27-15-21-15 ^T K 111LSL Page 1 to the following: 50/60REOZJD 800/150180 200REOZJF 125' 18 REC? J 40/50/230-275REOZJE 30OREOZJ Weather Enclosure Standard Features • rate '-mourKed'fencer '.ex)tsieexhau cQrTnGctor • Lrft base or tank -mounted, steel construction with hinged doors. • Fade-, scratch-, and corrosion -resistant Kohler® Power Armor- cream beige automotive -grade textured finish. • Enclosure has four large access doors which allow for easy maintenance. • Lockable, flush -mounted door latches. • Vertical air inlet and outlet discharge to redirect air and reduce noise. • Gemmed o with and 2 1 1< h 150 m h wind load ratln . Sound Enclosure Standard Features • (lFclude-sTatlydfitl3e weatherT—Wo—sure featy-Fe§ itbTft-) af—ddiLa�of acDustw�lirasuSatiQ" nTinate�ata • Lift base or tank -mounted, steel or aluminum construction with hinged doors. Aluminum enclosures are recommended for high humidity and/or high salt/ coastal regions. • Acoustic insulation that meets UL 94 HF1 flammability classification and repels moisture absorption. • Sound attenuated enclosure that uses up to 51 mm (2 in.) of acoustic insulation. Subbase Fuel Tank Features 4 The fuel tank has a Power Armor Plus- textured epoxy -based rubberized coating. The above -ground rectangular secondary containment_ generator set skid (subbase). • Both the inner and outer tanks have emergency relief vents. • Flexible fuel lines are provided with subbase fuel tank selection. • The second containment generator set base tank meets ULt4 tank requirements. The inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel if the inner tank leaks or ruptures. • State tanks With v in ca acities are an available option. Drfda Dap . I Protectio FDEP F'e No Efd-q4 ov Weather and Sound Fade-, scratch-, and Hinged doors Lockable, flush- Enclosed exhaust silencer Vertical air corrosion- resistant for ease of mounted door latches for improved safety and discharge through Power Amer^ finish servicing prevent tampering noise reduction an air outlet grille \ I I I I ADV�742& Atiemator Rodent guards and Fixed air Oii drain Acoustic insulation access skid end caps flow Inlet and radiator meeting UL 94 HF1 panel prevent animal entry grille drains flammability classifimtion Note: 20-40REOZ IC models shown, other models are similar. Refer to the respective ADV drawings for details. Enclosure Features • Available in steel (14 gauge) formed panel, solid construction. Preassembled package offering corrosion resistant, dent resilient structure mounting directly to lift base or fuel tank. • Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design. • Cooling/combustion air intake with a horizontal air inlet. • Power Armor- automotive -grade finish resulting in advanced Sized for maximum cooling airflow. corrosion and abrasion protection as well as enhanced edge coverage and color retention. • Service access. Multi -personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, • Internal exhaust silencer offering maximum component life oil fill, and battery. and operator safety. • Cooling air discharge. Weather protective design featuring a NOTE: Installing an additional length of exhaust tail pipe may vertical air discharge outlet grille. Redirects cooling air up increase backpressure levels. Please referto the generator set and above enclosure to reduce ambient noise. spec sheet for the maximum backpressure value. ❑ APPROVEDAS NOTED ❑NOT APPROVED Additional Sound Enclosure Features REMM OF THRS SHOP CE%NfrH THE DESIGN WNffDrOME PR01ECrMD FOR COMP ME IxroRIMIYJx Grvw Ix THE mmMCr PW6 AND SPEoMMU)m I=0=G SUPPIEMENrAI AND KMUt PWV61ox31. AND 6 NOT • Available in steel (14 gauge) or aluminum 3.2 Trim (0.125 in.) • Cooling air discharge. The ` W ""�RIAE R 4u R[D of formed panel, solid construction. acoustic insulation with ur .f.1.._� RENaV SHALL NOT Rnaon a IF,rN OR FROM THE FZPOEBU=of OETMU of DEMON, OI MEANS MDMENIOOP, • Attenuated design. Acoustic insulation UL 94 HFi THESE SHOP DRAWINGS WERE ORORNA NMWNORMm. M30, OR OF ME llxw WIIII OIIIER IROR CoN RAC.. NEN WAIRONS ON OF ME PIANS, SrtUFYAT101E OR WMPAR. ANY NOrATD1E ON listed for flame to 51 in.) REVIEWED FOR COMPLETENESS resistance offering up mm (2 Am=DMMGG MRN`ATaNSSHALLNWBEwNs"umm ADIIID.QQ£AmI11DxMWOREDRmsT. mechanically restrained acoustic insulation. ND GENERAL COMPLIANCE WIT REVEW OF DwGN WWUn= AND DRMMNGS MEMBER 9, HE PLANS AND SPECIFICATIONS [BY SPMXW MUNHAS 6 NMIED TO DESIGN INIENS AND DOES NOT COMmmE A DEEMED CRM OF G RAWNS. NOR BOB n IMECO, INC. THIS STAMP DOES RE+m'EDnauNTHEsera w E"GUMERS FROM THEWPOMBRITY OF TmNOT CONSTITUTE APPROVAL NOR BT: H.samheE/ OF SAID DRAWINGS \ 1 ^IISAPPROVAL DATE 9-21-t5 DATED ON: 10-05-2015 Subbase Fuel Tank Electrical Removable Emergency Normal Law Additional fitting Power Anror Plus" coating stub -up area engine supply Inner tank vent fuel level for optional for advanced corrosion and open to bottom diptube relief vent switch accessory abrasion protection THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WIT THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON : 10-05-2015 Fuel fill with Fuel leak Removable fuel lockable cap and Fuel level Emergency outer Basin detection switch return diptube 203 tom (8 in.) riser gauge tank relief vent drain 9f4�I�J E O11"111,iI. Note: 20-40REOZJC models shown, other models are similar. AEAA743(F Refer to the respective ADV drawings for details. v v v o v v o v �� o o v v o v •� i i I I I i 0 � � r 4 oIo vv v �� vv ova v a J v a v v v v Standard Subbase Fuel Tank Features • Extended operation. Usable tank capacity offers full load standby operation of up to 72 hours. • Power Armor Plus"' tortured epoxy -based rubberized coating that creates an ultra -thick barrier between the tank and harsh environmental conditions like humidity, saltwater, and extreme temperatures, and provides advanced corrosion and abrasion protection. • UL listed.- Secondary containment generator set base tank meeting UL 142 requirements. • Emergency pressure relief vents. Vents ensure adequate venting of the inner and outer tank under extreme pressure and/or emergency conditions. • Normal vent with cap. Vent is raised above lockable fuel fill. • Low fuel level switch. Annunciates a 50% low fuel level condition at generator set control. • Leak detection switch.-Annunciateaacontained 'primary tank fuel leak condition at generator set control. -A-NFPA=compliant =Designed to comply-withthe•installation-r-Elec[dcalstutr-up-- standards of 141-PA30 and 111-PA37. • Integral external I'ff lugs. Enables crane with spreader -bar l fling of the complete package (empty tank, mounted generator set, and enclosure) to ensure safety. G&59 5/14ea Page 3 © APPROVED ❑RESUBMIT ❑ APPROVED AS NOTED ❑NOT APPROVED REVIEW OF THIS SHOP DRAWING O OMrIED TO CONFORMANCE WRN THE DESIGN WNQPTOFTHE PROIELTAND FOR COMPLIANCE WITH THE INFORMATION GNEN IN THE OJNIILACr PLANS AND SPECIFICATIONS (INCWDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND U NOT INTENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED OR THHT ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONABIl1TY OF DETAILS OF DESIGN, DIMENSIONS, lOB CONDITIONS, WNSTRUCnON MEANS AND METHODS, COORDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENTS OF THE PLANS, SPEOFlCATIONS OR WNTRACT. ANY NOTATIONS ON THIS SHOP DRAWING MADE BY ATgNS SMALL NOT BE O]FLSTXUm TO AUIHORDEADDITIONAL WOplt OR MST. REYIEW OF DESIGN CALQ1lAT10N5 AND DRAWINGS PREPARED BY SPECIALTY ENGINEERS IS UMRFD TO DESIGN INTENT AND D06 NOT CONSRME A DETAILED CHEIX OF CALCULATIONS, NOR DOES R RELIEVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF THE DETAILING OFTHESPEOALTYODMPONFMOR SYSTEM. BY. H.Sanchez DATE nTKI N 5 �21-i5 State Code Subbase Fuel Te Electrical Fuel leak Additional fitting LOW Power Armor Plus—coafing Emergency Additional fitting Basin stub -up area detection for optional fuel level for advanced corrosion and Inner tank for optional drain open to bottom switch accessory swtttll abrasion protection relief vent accessory I O° Removable Removable engine supply fuel return dipobe diptube Note: 20-40REOZJC models N➢nrel Topfluid Fuel fig with Fuel level vent containment lockable cap and gauge drain 51 nun (2 In.) riser I Ilg APPROVED LJ RESU IT ❑ APPROVED AS NOTED ❑ NOT PROVED REWEw OF THa SHOP DRAG a UMITED TO ONNFORMUEa W" THE DESIGN WNORITOFTHE PROIECTAND MR DO APUANa WITH WE MFORNNTION GNEN W THE WNEMCT PLUG I NO WEOF =M (INCLUDING SUPPLEMENTAL AND VEOAL PROVE OEM, AND IS NOT INTENDED TO BE A VERIR AWN OF TOTAL MAT.AML REQUIRED OR THATALE REQUIRED ARESNPNRL REMOF SHADNOF M THEWNTRACIOR RFSPORSIBI STARS DUNS% FIR MMTHE W O M DIMRDMA NWMI MDEfIGN. NS ANDMEMOD; E5 ORTIONM OOMER OF U FR NOIAMONENIN WEPT SPED CAMS OR C NTANY OF THE P OR ESMME NOTATIONS ON DRA ING MADE U MU SHOP oMWMG MADE BY ATMNS SNAIL ME BE WNSTRUfD TO DF DUAGN RLWO WWSf. MWEW OF DFLGtI CAINIATNINS MD DMW REARM X PREPARED BY MMJuTY ENGINEERS L5 LIMITED TO DESIGN 1 M AND GOES NOT WNSQnIEE A DEEMED ono OF CXCUTAT1 N5, NOR DOES n REUEVE THE SPR=W ENGINERS FROM THE R 1' N UBI ME OF THE DCTMUNGOFTHESVEOAITYWMPONENTOR M ii.$aRM e2 DA 9-2T-15 AT I N s Emergency outer O ADV-75949 other models are similar. Refer to the respective ADV drawings for details. State Code Subbase Fuel Tank Features • State tank designed to comply with the installation standards • Includes all of the Standard Subbase Fuel Tank Features. of the Florida Dept of Environmental Protection (FDEP) File No. EQ-634. THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS State Code Subbase Fuel Tank Options AND GENERAL COMPLIANCE WITI- THE PLANS AND SPECIFICATIONS Bottom Clearance Fuel Supply Options BY IMECO, INC. THIS STAMP DOES ® I -beams, provides 106 mm (4.2 in.) of ground clearance ❑ Fire safety valve (installed on fuel NOT CONSTITUTE APPROVAL NOR ❑ Ball valve [installed on fuel supply DISAPPROVAL OF SAID DRAWINGS Fuel In Basin Options DATED ON: 10-05-2015 Fuel in basin switch, Florida Dept of Environmental High FuellLeveLSwitch_ Protection (FDEP) File No. EQ-682 approved ❑ High fuel level switch ❑ Fill pipe extension to within 152 mm (6 in.) of bottom of fuel tank. ❑ 18.9 L (5 gallon) spill containment with 95% shutoff ❑ 18.9 L (5 gallon) spill containment ❑ 18.9 L (5 gallon) spill containment fill to within 152 mm (6 in.) of bottom of fuel tank ❑ 28.4 L (7.5 gallon) spill containment, Florida Dept. of Environmental Protection (FDEP) File No. EQ-W approved ® 28.4 L (7.5 gallon) spill containment with 95% shutoff, Florida Dept of Environmental Protection (FDEP) File No. EQ-345/ EQ-257 approved Normal Vent Options ❑ 3.7 m (12 ft.) above grade (without spill containment) ❑ 3.7 m (12 ft.) above grade (with spill containment) Tank Marking Options ❑ Decal, Combustible Liquids - Keep Fire Away (qty. 2) ❑ Decal, NFPA 704 identifcaton (qty. 2) ❑ Decal, tank number and safe fuel fill height (qty. 2) ® Decal, tank number and safe fuel fill height, NFPA 704 identification G6.99 5/14aa Page 4 =OX, Now E Supply Fuel pply Hours Enclosure and Subbase Fuel Tank Sound Pressure at 60 Hz with Full Load at 7 m (23 R), Max Dimensions, mm (In.) Max Weight, kg cab.)" Fuel Tank at 60 Hz with Fuel Tank Weather/ Capacity, Full Load, %Wiith Steel With Aluminum Height, Sound L(gal.) Nominal/Actual Length Width HeIgM Enclosure Enclosure man can.) dB(A) OOREOZJF without IBC Seismic Certification No Tank 0 2821 (111.1) 1156 (45.5) 1575 (62) 1483 (3289) 1351 (2979) 152 (6) 83169 791 (209) 24/30 19W (76) 1766 (3894)' 1635 (3604)' 508 (20) 1317 (348) 48/50 2235 (88) 1882 (4150)' 1751 (3860)' 813 (32) 80RE0ZJF with IBC Seismic Certification No Tank 0 2821 (111.1) 1156 (45.5) 1 1525 (60) 1483 (3269) 1351 (2979) 102 (4) 83/69 757 (200) 24/28 1880 (74) 1851 (4080)' 1719 (3790)* 457 (18) 1313 (347) 48160 2185 (86) 2108 (4647)* 1976 (4357)" 762 (30) 80REOZJF with State Code Fuel Tankt 814 (215) 1 24/31 3400 (133.9) 1156 (45.5) 1855 (73) 1996 (4400)* 1864 (4110)' 432 (17) 83/69 1571 (415) 48/60 2185 (86) 2236 (4929)' 2104 (4639)' 762 (30) 100REOZJF without IBC Seismic Certification No Tank 0 2821 (111.1) 1156 (45.5) 1 1575 (62) 1592 (3510) 1461 (3220) 152 (6) 82/69 791 (209) 24/25 1930 (76) 1875 (4134)' 1744 (3844)' 508 (20) 1696 (448) 48/54 1 3400 (133.9) 2235 (88) 2070 (4564)' 1939 (4274)' 813 (32) 100RE0ZJF with IBC Seismic Certification No Tank 1 2821 (1111) 1166 (45.5) 1 1525 (60) 1592 (3510) 1461 (3220) 102 (4) 82/69 757 (200) 24/24 1880 (74) 1 1960 (4320)* 1828 (4030)* 457 (18) 1699 (449) 48/54 13400 (133.9) 12185 (86) 1 2345 (5170)* 2214 (4880)* 762 (30) 1 OOREOZJF with State Code Fuel Tankt 814(215) 24/26 3400 (133.9) 1156 (45.5) 1855 VS) 2105 (4641)' 1974 (4351)' 432 (17) 82/69 1571 (415) 48/50 2185 (86) 2345 (5170)' 2214 (4880)' 762(30) 12BREOZIG No Tank 0 3532 (139.0) 1153 (45.4) 1753 (69) 1651 (3632) 1515 (3333) 0 (0) 87173 1128 (298) 24/30 2236 (88) 2400 (5280)' 2264 (4981)* 483 (19) 2207 (583) 48158 2667 (105) 2751 (6052)' 2615 (5753)* 914 (36) 1196 (316) 1 24/31 4414 173:$ 1753 Q 2236 (88) 2382 (5240)* 2446 (4941)" 483 (19) 87/73 2252 S95 48/60 2591 10 2654 (5839)* 2600 5# 838 (33) 15OREOZJF No Tank 0 3532 (139.0) 1153 (45.4) 1753 (69) 1860 (4101) 1724 (3800) 0 (0) 86/75 1128 (298) 24/25 2238 (88) 2609 (5752)* 2473 (5452)* 483 (19) 2207 (568) _ _ _ _ 48/49 _2687 (105) - 2960_(6526)* _ 2824_ (6226)*_ 914. (36) -... 15OREOZJF with State Code Fuel Tankt 2455 (5412)* 489�9j --1196-(316) 24/27 4414=(173:8)_ -1753-(45[4)=- -2236-(88) 259--(5772)* 2591 (102) 2890 (6361)* -2727 (6012)* 83g (33) -66j75� Note: Data in table is for reference only, refer to the respective ADV drawings for details. Note: Refer to TIB-114 for generator set sound data * Max weight includes the generator set (wet) using the largestaltemator option, enclosure with acoustic t State code fuel tank specifications (height and weight) include I-beam option. THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WIT THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 r6% 5/14ea Pagel IN APPROVED LI RBURMn ❑ APPROVED AS NOTED ❑NOTAPPROVE) IE W OF 1Ntl 91W DMWWG 611M TO CANE AR a NEpmGXmN¢FIOi1NE p101ECTpNO FtlICWAft4NQ W11 NMD.G G`/FN IN TIE mMI1gR RMS MT E D4 ! wauoVle wVflEMwru sHO a = MARR s4 EWIR NImOEO ro 9E A VFAIfIGTOX OF TRRL MglEplµ REIXIIRI NAr ALL OEMs p WUD ME sHONN. RENEW SX NO! R IpNg WIIX ORRpTMamM.Wr OMFA MGNRWD ME RANs. SVFlIEIG E BV m mpIMST. N? NOTAiIQIs swR pRAWRNG R4➢E car g1T16 sxgLL xar az eeearpRa roR�APnnwNAEwmRmmsr. w R Rmw wmumra nxo GMwur4 RpEVARm LLLIY ENGY6 UMllm ro CEpGH v11pT qNO OOFS I R R W OIEOE a MEOIIATOq NM WT1E mEGgtW ORE NE mGWEms raaM THE RE4tlmpIN1Y R ATKINS KOHLER POWER SYSTEMS ❑X APPROVED ❑ RESUBMIT ❑ APPROVED AS NOTED ❑ NOTAPPROVED REVIEW OF THIS SHOP DRAWING IS LIMITED TO CONFORMANCE WITH THE DESIGN CONCEPF OF THE PROJECTAND FOR COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICATIONS [INCLUDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND LS NOT INTENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED OR THAT ALL ITEMS REQUIRED ARE SHOWN. REVIEW SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESIGN, DIMENSIONS, JOB CONDITIONS, CONSTRUCTION MEANS AND METHODS, COORDINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENTS OF THE PLANS, SPECIFICATIONS OR CONTRACT. ANY NOTATIONS ON THIS SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED TO AUTHORIZE ADDITIONAL WORK OR COST. REVIEW OF DESIGN CALCULATIONS AND DRAWINGS PREPARED BY SPECIALTY ENGINEERS IS LIMBED TO DESIGN INTENT AND DOES NOT CONSTITUTE A DETAILED CHECK OF CALCULATIONS, NOR DOES IT RELIEVE THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF THE DETAILING OF THESPECIALTY COMPONENT OR SYSTEM. BY: H. 9-2AT K I N S DATE: 9-21-15 1-15 THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WITF THE PLANS AND SPECIFICATIONS BY IMECO, INC. TIES STAMP DOES NOT CONSTITUTE APPROVAL NOR DISAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 KOHLOt . POWER SYSTEMS TIB-102 TECHNICAL INFORMATION BULLETIN Alternator Data Sheet Alternator PQ d: 1800 RPM el: LF", COPY Frequency: 60 Hz Leads: 4 kW' kVA Class B Class F Class H 80°C 90°C 95°C 105°C 130"C 125'C 150°C Voltage Power L-N/L-L Phase Factor Continuous Lloyds ASS Continuous Standby Continuous Standby 1201240 1 1.0 117.5 125.0 128.0 133.5 144.0 142.5 152.5 117.5 125.0 min ni 111%9%144.0 142.5 152.5 1201240 1 0.8 66.0 71.5 74.5 78.5 87.0 85.5 93.5 82.5 89.0 93.0 98.0 108.5 106.5 116.5 All data tested in accordance with IEEE Standard 115. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Submittal Data: 1201240 Volts, 1.0 PF, 1800 RPM, 60 H7,1 Phase, 130°C Rise Ohms Typical Cold Resistances Typical Field Current Phase Resistance 0.005 Full Load Rotor Resistance 6.502 No Load Harmonic Distortion RMS Total Harmonic Distortion Max. Single Harmonic Deviation Factor (No Load, L-L) ❑X APPROVED ❑ RESUBMIT Telephone Influence Factor ❑ APPROVED AS NOTED ❑ NOT APPROVED mutation Class EVIEW OF THIS SHOP DRAWING IS LIMITED TO CONFORMANCE WITH per NEMA MGt 1.66 HE DESIGN CONCEPT OF THE PROJECFAND FOR COMPLUW CE WITH THE (FORMATION GIVEN IN THE CONTRACT PLANS AND SPECIFICATIONS NCLUDING SUPPLEMENTAL AND SPECIAL PROVISIONS), AND IS NOT (TENDED TO BE A VERIFICATION OF TOTAL MATERIAL REQUIRED OR RAT ALL ITEMS REQUIRED ARE SHOWN. RENEW SHALL NOT BELIEVE HE CONTRACTOR FROM THE RESPONSIBILITY OF DETAILS OF DESIGN, IMENSIONS, JOB CONDITIONS, CONSTRUCTION MEANS AND METHODS, DOMINATION WITH OTHER TRADES, OR ANY OTHER REQUIREMENTS F THE PLANS, SPECIFICATIONS OR CONTRACT. -ANY -NOTATIONS -ON - - HIS SHOP DRAWING MADE BY ATKINS SHALL NOT BE CONSTRUED I LITE A DETAILED CHECK OF CALCULATIONS, NOR DOES r THE SPECIALTY ENGINEERS FROM THE RESPONSIBILITY OF THI IG OFTHE SPECIALTY COMPONENT OR SYSTEM. 9.21-15 nTKI NS 9-21-15 Symbol Value IfFL 14.5 amps Ifm 8.3 amps 2.73% 3rd <5% <50 H THESE SHOP DRAWINGS WERE REVIEWED FOR COMPLETENESS AND GENERAL COMPLIANCE WIT THE PLANS AND SPECIFICATIONS BY IMECO, INC. THIS STAMP DOES _ NOT CONSTITUTE_ APPROVAL NOR -_ DISAPPROVAti OFSAID DRAWINGS DATED ON : 10-05-2015 TIB-102 4T13X 60 Hz 5111n 100 98 96 94 92 c m 90 w 88 86 84 82 80 0 4T13X, 60 Hz,1201240 Volts, Wye TYPICAL ALTERNATOR EFFICIENCY" I HESE SHOP DRAWINGS WEREEVIEWED FOR COMPLETENESSD GENERAL COMPLIANCE WITE PLANS AND SPECIFICATIONS IMECO, INC. THIS STAMP DOESOT CONSTITUTE APPROVAL NORSAPPROVAL OF SAID DRAWINGS DATED ON: 10-05-2015 1.0 PF 25 50 75 100 125 150 OJJtput(kYV) C AS& py FILmEw 4T13X, 60 Hz,1201240 Volts TYPICAL MOTOR STARTING CHARACTERISTICS* 4U ' AP ROV ❑RESUBMIT 35 OVED NOTED ❑ NOT APPROVED EW 0 THIS SHO DRAWIN LS LIMITED TO CONFORMANCE WrrH THE DESIG CONCEPT OF THE PR JECFAND FOR COMPLIANCE WITH THE 30 NTRACr PLANS AND SPECIFICATIONS ENTAL AN (INCLUDIN SUPPLE SPECIAL PROVISIONS), AND LS NOT INTENDED TO BE A RIFICATIO OF TOTAL MATERIAL REQUIRED OR m. 25 THAT ALL EMS RE )RED ARE HOWN. REVIEW SHALL NOT RELIEVE PONSIBILJTY OF DETAILS OF DESIGN, THE CON! CTOR FR M THE R m rA 20 DIMENSIO COORDR S, JOB CO ON WITH DITIONS,C OTHER NSTAUCTION MEANS AND METHODS, DES, OR ANY OTHER REQUIREMENTS R CONTRACT. ANY NOTATIONS ON OF THE P NS, SPEC] )CATIONS j THIS SHOI DRAWING MADE BY j TKINS SHALL NOT BE CONSTRUED TO - - --- -- - - ' 15 -' ---- - -' - ----- ---' - AUTHOR12 ADDTNO LWORKO tCOST. -- ----- NS AND DRAWINGS PREPARED BY - - — - - - - --- ;;;CI LTY. CO_ EN - - ENGINEE A DET - LED CHE_ - _ 1G[L]NTENr_AN0_DOES. -OF-CALCULATIONS, NOR_ DOES -AT IS -FROTHERESPONSIBILITYOFTHE M - - -'- - - _ - --- - - - - — - DETAIUNGOFTHESP IALTY COA PONENTORSYSTEM. 5 BY: H.Sanc ez K I N S DATE: 9-21 15 /w` / \T n 0 50 100 150 200 250 300 350 400 450 500 550 Locked Rotor KVA All data tested in accordance with IEEE Standard 115. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. 2 4T13X 60 Hz 5/11n TIB-102