Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE:ni - c'--- Planning& Development Services Department �+1"C® • Building & Code Regulations Division RECEIVED G 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 SEP / B' 265 Certification for Design Load Compliance Pursuit Boats - Mill Shop Canopy Addition ��H Y NED Project Name: P PY )� Project Address: 3901 St. Lucie Blvd. Fort Pierce, FL 34946 �1 LucieCounty Permit #:,5�1-59 04% Occupancy Type: F-1 Construction Type: III-B INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: O New Residences (single or multi -family) P o Residential Addition in y o Any accessory structure requiring a building permit F Lmla-'7 o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed X Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: B X C _D ' 4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft 5. Mean Roof Height 25 ft Roof Pitch: 112 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +27/-49 Zone 2: +27/-74 Zone 3: +27/-105 Zone 4: +49/-52 Zone 5: +49/-61 Garage: N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony: WA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: PARTIALL OPEN PRE-ENGINEERED METAL BLDG WITH DIAGONAL ROOF BRACING AND WIND COLUMNS 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil BearingPressure• 2000 _ _PSF—_Soil Test--Reports�Submitted?=NO =Yes — -- — -- —-�OESIGBfPROFESSIONALCERTIFIC_ATIONSTATEME_NT: - I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Michael A. Lue, P.E. FL 47520 Print Name Cert # & Co. Cert Auth. Date, and Seal M L Engineering, Inc. 2030 37th Ave, Vero Beach, FI 32960 Company Name & Address Revised 07/25/2014