Field and Laboratory Report Transmittal Sheet
Client: Richard K. Davis Construction Corporation
P.O. Box 186
Fort Pierce, FL 34954
Project: Pursuit Boat Canopy
Permit # 1507-0443
3901 St. Lucie Blvd/ Airport Road
Ft. Pierce, FL
As requested, a representative of Universal Engineering Sciences, Inc. (UES) was at the
referenced project to provide construction materials testing services.
The results of the observations and/or tests are summarized on the attached sheets. The
reports are dated as follows: 45269 ARD7, 45269 DT1. We trust this information is sufficient for
your immediate needs. If you have any questions, please do not hesitate to contact the
undersigned.
Reviewed By
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 549
--- - - -
NOV 1 9 RECO _
(chard E. Hoaglin;
STATE OF FLORIUA
Licensed Professional Engineer No. 48796
I CC Email: bmclamarkdavis.com
1CC Fax: City of Port St. Lucie Building Department 1-772-344-4226
820 Brevard Avenue, Rockledge, Florida 32955 (321) 638-0808 Fax (321) 638-0978
www.UniversalEngineering.com
UN1VErL;SAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Construction Materials Testing • Threshold Inspection
Building Inspection • Plan Review • Building Code Administration
820 Brevard Avenue
321.638.0808
Client:
Project:
Rockledge, FL • 32955
Fax: 321.638.0978
Date of Activity:
Technician:
Activity Record
1. 'roject No: 0310.1500325.0000
UES Report No: 45269 ARD1 102815
On -Site Time (hrs):
1.00
Lab Time (hrs):
0.00
Travel Time (hrs):
1.00
Total Time (hrs):
2.00
Richard K. Davis Construction Corporation
P.O. Box 186
Fort Pierce, FL 34954
Pursuit Boat Canopy
Permit # 1507-0443 3901 St. Lucie Blvd/ Airport Road, Ft. Pierce, St. Lucie County, FL
Wednesday, October 28, 2015
Cliff Cherrnay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project
site for the purpose of earthwork testing for the Footings for canopy columns.
While on site, the technician observed the general condition of the areas to be tested and performed 8
density test(s) for Footings for canopy columns. All test(s) were performed in accordance with the ASTM
D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of
the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
This test(s) was performed without deviation from ASTM procedure.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
1'
`JNIVEASAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Construction Materials Testing • Threshold Inspection
Building Inspection • Plan Review • Building Code Administration
820 Brevard Avenue • Rockledge, FL • 32955
321.638.0808 Fax:321.638.0978
Project No: 0310.1500325.0000
LIES Report No: 45269 DTI 102815
In -Place Density Test Reoort
Client: Richard K. Davis Construction Corporation
P.O. Box 186
Fort Pierce, FL 34954
Project: Pursuit Boat Canopy
Permit # 1507-0443 3901 St. Lucie Blvd/ Airport Road, Ft. Pierce, St. Lucie County, FL
Area Tested: Footings for canopy columns
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 10/28/2015
Lab: ASTM D-1557
Technician: Cliff Cherrnay
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and
do not address the condition of the underlying soils below the tested depths.
Test
#
Location of Test
Range
(FT)
Depth
(IN)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
Compaction
Comments
(3)
1
South end east footing
0-1
12.00
18562
106.2
7.1
96
A
2
South end west footing
0-1
12.00
18562
111.0
10.0
100
A
3
2nd row from south end west footing
0-1
12.00
18662
107.6
11.1
97
A
4
2nd row from south end east footing
0-1
12.00
18562
106.5
10.0
96
A
5
3rd row from south end east footing
0-1
12.00
18562
108.1
10.2
97
A
6
3rd row from south end west footing
0-1
12.00
18562
107.4
9.8
97
A
7
Footings on north end west footing
0-1
12.00
18562
108.9
8.2
98
A
8
Footings on north end east footing
0-1
12.00
18562
111.0
8.0
100
A
(I)- Ref. Datum: 0 = Bottom of Footing
�Prodtor—
--MaximumT= _j
=optimum
#
Dry
Moisture.
Density
Content
18562
111.0
11.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
___ _.A. Compaction meets
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
UNIVERSAL
LOCATIONS:
• Atlanta
• Daytona Beach
ENGINEERING SCIENCES
rranun Myers
Pierce
Consultants In:Geotechnical Engineering • Environmental Sciences
Gainesville
• Jacksonvill
Geophysical Services •Construction MaterialsTesting •Threshold Inspection
Kissimnvillc
KissimmeED e
Building Inspection • Plan Review • Building Code Administration
Leesburg
• Miami
Ocala
• Orlando (Headquarters)
Project No.:
0310.1500325.0000
• Palm Coast
Panama City
SCANNED
Pensacola
Date Typed:
October 29, 2015 ��
Rockledge
samsoma
St. Lucie
Tampa
Counts,
• West Palm Beach
Field and Laboratory Report Transmittal Sheet
Client: Richard K. Davis Construction Corporation
P.O. Box 186
Fort Pierce, FL 34954
Project: Pursuit Boat Canopy
Permit # 1507-0443
3901 St. Lucie Blvd/ Airport Road
Ft. Pierce, FL
As requested, a representative of Universal Engineering Sciences, Inc. (LIES) was at the
referenced project to provide construction materials testing services.
The results of the observations and/or tests are summarized on the attached sheets. The
reports are dated as follows: 45269 ARD1, 45269 DT1. We trust this information is sufficient for
your immediate needs. If you have any questions, please do not hesitate to contact the
undersigned.
Reviewed By
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 549
Richard E. Hoaglin,
PE- -- --- - -- - - - -- -- _—
--- - " 20
5.10.29-10i1124 - ---- - --
r�-04'00'
Richard E. Hoaglin, P.E.
STATE OF FLORIDA
Licensed Professional Engineer No. 48796
ICC Email: bmclamna.rkdavis.com
ICC Fax: City of Port St. Lucie Building Department 1-772-344-4226
920 Brevard Avenue, Rockledge, Florida 32955 (321) 638-0808 Fax (321) 638-0978
www. UniversalEngi n eering. com
UNIV-RSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Construction Materials Testing • Threshold Inspection
Building Inspection • Plan Review • Building Code Administration
820 Brevard Avenue • Rockledge, FL • 32955
321.638.0808 Fax:321.638.0978
eS Project No: 0310.1500325.0000
LIES Report No: 45269 ARD1 102815
On -Site Time (hrs):
1.00
Lab Time (hrs):
0.00
Travel Time (hrs):
1.00
Total Time (hrs):
2.00
Activity Record
Client: Richard K. Davis Construction Corporation
P.O. Box 186
Fort Pierce, FL 34954
Project: Pursuit Boat Canopy
Permit # 1507-0443 3901 St. Lucie Blvd/ Airport Road, Ft. Pierce, St. Lucie County, FL
Date of Activity: Wednesday, October 28, 2015
Technician: Cliff Cherrnay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project
site for the purpose of earthwork testing for the Footings for canopy columns.
While on site, the technician observed the general condition of the areas to be tested and performed 8
density test(s) for Footings for canopy columns. All test(s) were performed in accordance with the ASTM
D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of
the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
This test(s) was performed without deviation from ASTM procedure.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
VNIVr.RSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Construction Materials Testing • Threshold Inspection
Building Inspection • Plan Review • Building Code Administration
820 Brevard Avenue • Rockledge, FL • 32955
321.638.0808 Fax:321.638.0978
HES Project No: 0310.1500325.0000
WES Report No: 45269 DT1 102815
In -Place Density Test Resort
Client: Richard K. Davis Construction Corporation
P.O. Box 186
Fort Pierce, FL 34954
Project: Pursuit Boat Canopy
Permit # 1507-0443 3901 St. Lucie Blvd/ Airport Road, Ft. Pierce, St. Lucie County, FL
Area Tested: Footings for canopy columns
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 10/28/2015
Lab: ASTM D-1557
Technician: Cliff Cherrnay
Requirements: 95% of Proctor maximum dry density. These tests apply'to the fill and/or surficial soil conditions only and
do not address the condition of the underlying soils below the tested depths.
Test
#
Location of Test
Range
FT
t )
Depth
(IN)
Proctor
y
t 1
Field Dry
Density
(PCF)
Field
Moisture
07,
^/,
Compaction
P
Comments
3
( )
1
South end east footing
0-1
12.00
18562
106.2
7.1
96
A
2
South end west footing
0-1
12.00
18562
111.0
10.0
100
A
3
2nd row from south end west footing
0-1
12.00
18562
107.6
11.1
97
A
4
2nd row from south end east footing
0-1
12.00
18562
106.5
10.0
96
A
5
3rd row from south end east footing
0-1
12.00
18562
108.1
10.2
97
A
6
3rd row from south end west footing
0-1
12.00
18562
107.4
9.8
97
A
7
Footings on north end west footing
0-1
12.00
18562
108.9
8.2
98
A
8
Footings on north end east footing
0-1
12.00
18562
111.0
8.0
100
A
(1) Ref. Datum: 0 = Bottom of Footing
Proctor
#
- Maximum
--
Optimum
-
Dry
Density
—
- Moisture
Content
18562
111.0
11.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
-- - —B: Compaction does not meet—m'In: requirements -
C Moisture does not-rft squire is -- - -
_
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.