HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED
BY
FORM 405-10 St. Lucie Countv
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: JOSEPH & JUANITA TAYLOR
Builder Name:
Street LOT-23 ELLA AVE
Permit Office: Math County
City, State, Zip: HOSE SOUND, FL,
Permit Number.
Owner.
Jurisdiction: 631000
Design Location: FL, West Palm Beach
1. New construction or existing New (From Plans)
9. Wag Types(1328.0 sgfL)
Insulation Area
2. Single family or muNple family Single-family
a. Concrete Block - int Insuf, Exterior
R=5,0 1224.001N
b. Frame - Wood,. Exterior
R=13.0 104.00 it-
1 Number of units, d multiple family 1
c. WA
R= it,
4. Number of Bedrooms 3
d. WA
R= IF
5. Is this a worst case? No
10. Ceiling Types (1434.0 sgft.)
Insulation Area
a. Under Aft (Veined)
R=30,0 1306.00 IF
6. Conditioned Hoer area above grade (it-) 1306
b. Knee Wag (Vented)
R=19.0 128.00 ft'
Conditioned floor area below grade (N) 0
c. WA
R= IF
It. Duch
R fN
7. Wmdows(116.0 sqM) Description Area
a. Sup: Attic, Ret Attic, AH: Main
6 2612
a. U-Factor: Dbl, U-0.32 102.00 IF
SHGC: SHGC-021
b. U-Factor. GbL default 16.00 fe
12. Cooling systems
kBtutlu Efficiency
SHGC: Clear, default
a. Central Unit
28.0 SEER:16.00
c. U-Factor. WA fN
SHGC:
13. Heating systems
kelufir Efficiency
d. U-Factor: WA fp
a. Electric Strip Heat
2&0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 4.161 It
Area Weighted Average SHGC: 0263
14. Hat water systems
a. Electric
Cap: 40 gallons
S. Floor Types (1306.0 sgfL) Insulation Area
.
EF: 0.920
a. Slab -On -Grade Edge insulation R-0.0 1306.001N
b. Conservation features
b. WA R- fn
None
c. WA R- if
IS. Credits
Pstat
Glass/FloorArea: 0.090 Total Proposed Modified, Loads: 35.19
PASS
Total Standard Reference Loads: 45:03
!y �7
1 hereby certify that the plans and specifications covered by
Review of the plans and
InISSTgT
this calculation are In compliance with the Florida Energy
specifications covered by this
indicates
a e0
Code.
calculation compliance
the Code.
with Florida Energy
-PREPARED-BX� -
Before construction is completed__ _ __
this building will be inspected for
-compliance-WtttSectioaS53.908-
_FloridaSlatutes- �
1
U A
-
DATE:
-- - -- - -
-- - - -
p --_
-tfiereby ceA'dy-that'thisbm'iding, as designad; isn-com fiance= -
with the Florida Energy Code.
08 WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulati�ony� Inspection Checklist
❑ NT
Alin t1VVW �VVF4't'r i�V11+�V V1Y
Pit-kevlewid Not lu Co # .
Itevtet�d t3�t _
\ 6251201512:57 PM F_netgyGauge® USA - FiaRes2010 Section 405.4.1 mpgaM Software
Page 1 of 5
'
PROJECT
True:
Building Type:
Owner:
# of Una:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
NewtErasling:
Comment:
JOSEPH & JUANtrA TAYLO Bedrooms: 3
user Conditioned Area: 1306
Total, Sty: 1
1 Worst Case: No
Rotate Angle: 0
Malin County Crass Ventlatiom
531000 Whole Hotse Fan:
Shille4ansty
New (From Pam)
Address Type: Street Address
Lot#
BlocklSubl)lvisiom
Street LOT 23 M- A AVE
County: Martin
City, State, Tip: HOSE SOUND ,
FL,
CLIMATE
/
V Design Location
IECC Design Temp lm Demon Temp- Heating Design Daily Temp
TMY Site Zone 97.5 °6 2.5 % Winter Summer Degree Days Moisture Range
FL, West Palm Beath FL WEST PALM_BEAC 2 44 90 70
75 316 60 Medium
'BLOCKS
Number
1
Name
Biockl
Area Volume
1305 10448
N
SPACES
Number
i
Name
Main
Area Volume Ktchen Occupants Bedmorns
1306 10448 Yes 4 3
infra 10 Fuished Cooled Heated
1 Yes Yes Yes
FLOORS
#
Ficor TWe
Space Perimeter RYalue Area
Tile Wood Carpet
1 S de Edge lasulatic Mahn 166 it w 0 1308 ft'
0 D 1
ROOF
/
V If
Type
Roof Gable Roof Soma
Materials Area Area Color Absot
Stt A En Err& Deck Pitch
Tested Tested k (dog)
1
Hip Composition shingles 1513 fN 0 it, Medlum 0,85
No D.9 No 0 30.3
ATTIC
/
V #
Type.
Ventlation Vent-Raflo-(1-in). Area -
RBS IRCL'.
1 Futi_atiiG
Vetted 3DD 13M ff
N N
#
Cep T e
Space R-Vahie Area
Framing Free in= Type
_ 1
2
Under Attk (Vented)
Knee Wag (Vented)
Main 30 1306 to
Main 19 128 fe
0.11 Wood
DA1 Wood
\ 6M5*01512:57 PM EnergyGaugeO USA - FlaRes2010 Section 405.41 Compliant Software Page 2 of 5
Lv
2
z z
w
z
-Sd.
uj
r,
C-4
a c o6
9
Z
z
w
w w w w
z z 0 z z
IZU Um,
46
41
d 0
000
V
mn nn MIS mM
y
zzz
Z
mw m
>
ZO
ca
O
WW
ONt�+ rh �1D 1®Gt�p
00
'+
O
f]
w
99 rti YL� �rsS
mw
0
'� r
C�om-a+-+
�N3y
yy s�ppyy pppppp}}
p
0
a
wWW
o
n
g
W
'oLU
S
03
IlJjR
«
Q
f1
O
}
uj
ci
I
Egg
p
q
d
W
N
tim P-fwn MQQ}}��ppIS 920��pp
ry
`�
ggf
sw so
z
aleg
qik
{Lnpp�IL
N
Ada `da `da UL
0 u
9
F "�
tb
�
uj
INa. �
o@@
2
m WWW
m
o
i
E
J a
IIIII
pop��
m
.$I
w
.i
a
G�
W
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: LOT 23 ELLA AVE PERMIT #:
ROBE SOUND, FL,
MANDATORY REQUIREMENTS SUMMARY • See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfmtsq.fL Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
_
Duds
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shad
be considered duds or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R 2
+accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systemsshall not exceed the minimum ASHRAE 62 level,
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of=1
—& spas
_ _ - _ — _
-HP-shall-have the capabiiity_of operefing at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
----
-- -
=other_means,provenlo.reduce heat=lossexcept if-70e% of heat -from - -
= -- ---
_ - — —
- ite-recovered:energy Off/imer_sMtch=required-Gasheatersmunm m-
thermal efficiency=78°% (82% after4116113). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Cellingsllmee walls
406.2.1
I R-19 space permitting.
F
6125201512:57 PM Energyaauga USA - Flaftes2010 Section 405.4.1 Compliant Software Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY
! 1 CARD
t. New construction or existing
2. Single tam0y or family
3. Number of arils, if mine family
4. Number of Bedrooms
5, is tlhts;a Worst case?
6. Conditioned floor area (it)
7, Window, Desenirbon
a. U-Factor. Cbt, U=032
SHGC: SHGC=021
b. U-Factor: Gbl, default
SHGC: Clear, default
c. U-Factor. WA
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang OePft
Area Weighted Average SHGC:
New (From Plans)
single-farnly
1
3
No
1306
Area
102" tN
i6.00 fP
it,
ftf
8. Floor Types
insulation
a. rade Edge hodation
R--el)
b. WA
R=
c. WA
R=
4A61 it
0263
Area
1308.00 ft°
ftf
if
9.. Walt Types
a. Concrete Stock- mt mul, Exterior
b. Frame -Wood, Exterior
c. WA
d. WA
10.- .. Types
a. Under Attic (Vented)
b. Knee Wait (Vented)
c. NIA
11. Cads
a. Sup: Attie, Ref: Attic, AH: Main
12, Goofing systems
a_ Centrad Unit
14. Hotwafer systems
a. Electric
_ f r• f :• • f_ •Efficie Code
11
for Build
based on installed Code compliant features.
inealation
R=5.0
R-13.0
R-
R.
Insulation
R-30.0
R-19.0
R-
AT"
122440 if
104.00 iF
!tf
Area
1306.00 ftf
128.00 ftf
If
R IF
6 2612
WhAr Efficiency
28.0 SEM16.00
Note: This is not a Building Energy Rating. if your index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.tom for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
"Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
EnogyGabgai USA- FiaRes2010 section 405AA Compliant Softvrare