HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCESCANNED BY Planning & Development Services Department St. Lucie Countv MAN Building & Code Regulations Division — 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: Lr btr�j T'r.• le,pe %��OK11 S,o/1 .hC 'wrerf B/.�lc�iN cl Project Address: 9 63 S�&ae kr4, POif -5 . /Qc, FL 39! 93:?­ J Permit#: )SO2- 0/y6 Occupancy Type: SAi Construction Type: INSTRUCTIONS. FOR USE: • This certification must. be completed, signed, and sealed by the. design professional of record. • Submit (2) copies for residential, (3)copies for commercial with all permit applicationsinvolving the following: o New Residences (single or multi -family) o Residential Additiono Any accessory structure requiring a building permit�tCOPY o. Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida LIcA, - i Code Fifth Edition with 20 Lq .Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed —Open 3. Risk Category: 4,el II _III _ IV Exposure Category: _B 4,� C D 4. 'Design Wind Velocity /'/ 4 mph _ASD �FD End Zone Width: ft 5. 'Mean Roof Height l 9. a ft Roof Pitch: W.14 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): N7� Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: ..PSF nVIA 7CO3�l00a�= fo) Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: _PSF 4VeI04d�30(11) 8: Were Shear Walls Considered For Structure? _Yes Not Applicable Explain Why Not: h. 9. Is A Continuous Load Path. Provided? _Yes ✓Not Applicable Explain Why Not: - ----- --- - - - -- -- - -=— -� - - - --- G 0/ iAbltl 806-�- 10. Design Soil Bearing Pressure: 000 . PSF Soil Test Reports Submitted. /�0 s 1 .�, y- , I rN QhSCACC er -YCJIll1V fRVECJJIV1YNL l.CR11fI1:M 11 V1Y.JINICIVICIY I..: Gi�r;.IP./� (.certify that, to the best _of_my knowledge and. belief, the attached plans & specifications have been designed to l'pFv/r comply with the applicable structural portions of the buildingcodescurrently adopted and enforced. by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: AHMAD?Em SEnAGHAT (lE7- A .1 / A Print Name Cent # & Co. Cert Auth. * Siggpture, Date; Fd'_S 7 1 STATE OF011 : a' �'///;/�'ONAL E�G���\ Florlb - g549inz!!1 j anr� De.S�a� Inc. Company Name & Address ass colui J Al SSS 15 �ulfow , F/o/'J0 339131